Search NASA⌕ Search

SEARCH · Search NASA

Results for “TIMING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Transformation from proper time on earth to coordinate time in solar system barycentric space-time frame of reference

An expression was derived for the time transformation t - tau, where t is coordinate time in the solar system barycentric space-time frame of reference and tau is proper time obtained from a fixed atomic clock on earth. This transformation is suitable for use in the computation of high-precision earth-based range and Doppler observables of a spacecraft or celestial body located anywhere in the solar system; it can also be used in obtaining computed values of very long baseline interferometry data types. The formulation for computing range and Doppler observables, which is an explicit function of the transformation t - tau, is described briefly.

Moyer, T. D.↗

DCS - A high flux beamline for time resolved dynamic compression science – Design highlights

The Dynamic Compression Sector (DCS) beamline, a national user facility for time resolved dynamic compression science supported by the National Nuclear Security Administration (NNSA) of the Department of Energy (DOE), has recently completed construction and is being commissioned at Sector 35 of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The beamline consists of a First Optics Enclosure (FOE) and four experimental enclosures. A Kirkpatrick–Baez focusing mirror system with 2.2 mrad incident angles in the FOE delivers pink beam to the experimental stations. A refocusing Kirkpatrick–Baez mirror system is situated in each of the two most downstream enclosures. Experiments can be conducted in either white, monochromatic, pink or monochromatic-reflected beam mode in any of the experimental stations by changing the position of two interlocked components in the FOE. The beamline Radiation Safety System (RSS) components have been designed to handle the continuous beam provided by two in-line revolver undulators with periods of 27 and 30 mm, at closed gap, 150 mA beam current, and passing through a power limiting aperture of 1.5 x 1.0 mm{sup 2}. A novel pink beam end station stop [1] is used to stop the continuous and focused pink beam which can achieve a peak heat flux of 105 kW/mm{sup 2}. A new millisecond shutter design [2] is used to deliver a quick pulse of beam to the sample, synchronized with the dynamic event, the microsecond shutter, and the storage ring clock.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On time scales and time synchronization using LORAN-C as a time reference signal

The long term performance of the eight LORAN-C chains is presented in terms of the Coordinated Universal Time (UTC) of the U.S. Naval Observatory (USNO); and the use of the LORAN-C navigation system for maintaining the user's clock to a UTC scale is described. The atomic time scale and the UTC of several national laboratories and observatories relative to the international atomic time are reported. Typical performance of several NASA tracking station clocks, relative to the USNO master clock, is also presented.

Chi, A. R.↗

Estimating time and time-lag in time-of-flight velocimetry

Estimating time and time-lag in time-of-flight velocimeters is investigated. Statistics of a filtered Poisson point process is given. A Maximum Likelihood Estimator is compared with suboptimum estimators in terms of robustness. For a dominating background combined spatial and temporal processing can improve the robustness compared with purely temporal processing. Schemes for the spatial filters are given.

Lading, L.↗

Time resolved electron microscopy for in situ experiments

Transmission electron microscopy has functioned for decades as a platform for in situ observation of materials and processes with high spatial resolution. Yet, the dynamics often remain elusive, as they unfold too fast to discern at these small spatial scales under traditional imaging conditions. Simply shortening the exposure time in hopes of capturing the action has limitations, as the number of electrons will eventually be reduced to the point where noise overtakes the signal in the image. Pulsed electron sources with high instantaneous current have successfully shortened exposure times (thus increasing the temporal resolution) by about six orders of magnitude over conventional sources while providing the necessary signal-to-noise ratio for dynamic imaging. We describe here the development of this new class of microscope and the principles of its operation, with examples of its application to problems in materials science.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

First observation of radiative B⁰ → ΦK⁰γ decays and measurements of their time-dependent CP violation

We report the first observation of the radiative decay B⁰→ ΦK⁰γ using a data sample of 772 × 10⁶ BB¯ pairs collected at the (4S) resonance with the Belle detector at the KEKB asymmetric-energy e⁺e⁻ collider. We observe a signal of 37 ± 8 events with a significance of 5.4 standard deviations including systematic uncertainties. The measured branching fraction is B(B⁰→ ΦK⁰γ) = (2.74±0.60±0.32)×10⁻⁶, where the uncertainties are statistical and systematic, respectively. We also report the first measurements of time-dependent CP-violation parameters: S ΦK⁰ S γ = +0.74 ⁺0.72 –1.05 (stat) +0.10 –0.24 (syst) and A ΦK⁰ S γ = +0.35 ± 0.58(stat) +0.23 –0.10 (syst). Furthermore, we measure B(B⁺ → ΦK⁺γ) = (2.48 ± 0.30 ± 0.24) × 10⁻⁶, ACP = –0.03 ± 0.11 ± 0.08 and find that the signal is concentrated in the M ΦK mass region near threshold.

Sahoo, Himansu B.↗

New Limit on Time-Reversal Violation in Beta Decay

We report the results of an improved determination of the triple correlation DP{center_dot}(p{sub e}xp{sub v}) that can be used to limit possible time-reversal invariance in the beta decay of polarized neutrons and constrain extensions to the standard model. Our result is D=[-0.96{+-}1.89(stat){+-}1.01(sys)]x10{sup -4}. The corresponding phase between g{sub A} and g{sub V} is {phi}{sub AV}=180.013 deg. {+-}0.028 deg. (68% confidence level). This result represents the most sensitive measurement of D in nuclear {beta} decay.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time of Flight Electrochemistry: Diffusion Coefficient Measurements Using Interdigitated Array (IDA) Electrodes

A simple and straightforward method for measuring diffusion coefficients using interdigitated array (IDA) electrodes is reported. The method does not require that the exact electrode area be known but depends only the size of the gap between the IDA electrode pairs. Electroactive molecules produced at the generator electrode of the IDA by a voltage step or scan can diffuse to the collector electrode and the time delay before the current for the reverse electrochemical reaction is detected at the collector is used to calculate the diffusion coefficient. The measurement of the diffusion rate of Ru(NH3)6+2 in aqueous solution has been used as an example measuring diffusion coefficients using this method. Additionally, a digital simulation of the electrochemical response of the IDA electrodes was used to simulate the entire current/voltage/time behavior of the system and verify the experimentally measured diffusion coefficients. This work was supported as part of the Center for Molecular Electrocatalysis, an Energy Frontier Research Center funded by the Department of Energy, Office of Science, Office of Basic Energy Sciences.

Liu, Fei↗

Spread Spectrum Time Domain Reflectometry and Steepest Descent Inversion to Measure Complex Impedance

In this paper, we present a method for estimating complex impedances using reflectometry and a modified steepest descent inversion algorithm. We simulate spread spectrum time domain reflectometry (SSTDR), which can measure complex impedances on energized systems for an experimental setup with resistive and capacitive loads. A parametric function, which includes both a misfit function and stabilizer function, is created. The misfit function is a least squares estimate of how close the model data matches observed data. The stabilizer function prevents the steepest descent algorithm from becoming unstable and diverging. Steepest descent iteratively identifies the model parameters that minimize the parametric function. We validate the algorithm by correctly identifying the model parameters (capacitance and resistance) associated with simulated SSTDR data, with added 3 dB white Gaussian noise. With the stabilizer function, the steepest descent algorithm estimates of the model parameters are bounded within a specified range. Furthermore, the errors for capacitance (220pF to 820pF) and resistance (50 Ω to 270 Ω) are < 10%, corresponding to a complex impedance magnitude |R +1/jωC| of 53 Ω to 510 Ω.

14 SOLAR ENERGY↗