Search NASA⌕ Search

SEARCH · Search NASA

Results for “TPC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A Method to Extract the Charge Distribution Arriving at the TPC Wire Planes in MicroBooNE

In this technote, we describe the concept and general strategy of LArTPC drifted-charge extraction, which converts the raw digitized TPC waveform to the number of ionized electrons passing through the wire plane at a given time. The proper recovery of the number of ionized electrons from all wire planes is important to the success of the subsequent reconstruction algorithms. A number of building blocks for the processing algorithm are described and characterized. An example of implementation of the algorithm was realized inside the Wire-Cell reconstruction package. The performance was qualitatively illustrated on MicroBooNE data with event display pictures, which shows significant improvements. Some metrics to evaluate the performance of the TPC signal extraction procedure are described. Next steps towards the quantification of the effect of the proposed concept and optimization of the procedure are outlined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fission TPC FY2020 Report (Mid Q2 FY2021): Preliminary 235 U(n,f)/ 6 Li(n,t)α Cross Section Ratio Analysis & Update on the 239 Pu(n,f) Data Collection

Fission TPC L2 Milestone Description: The fission TPC experimental campaign is in its final stages of collecting high precision (n,f) cross section data aimed at improving our understanding of the 239 Pu fission process. During FY 2019 235 U(n,f)/ 6 Li(n,t) ratio data collection began at WNR/LANSCE. This data is the first step in demonstrating the efficacy of 6 Li(n,t) as a diagnostic standard for a 239 Pu(n,f) ratio measurement. In FY 2020 and FY2021, the NIFFTE Collaboration will analyze 235 U(n,f)/ 6 Li(n,t) data already collected to establish this technique in preparation for 239 Pu(n,f)/ 6 Li(n,t) ratio data. Additionally, the ability to vapor deposit 239 Pu was developed in 2019, greatly improving target quality. As access to experimental facilities allows, 239 Pu/ 235 U and 239 Pu/ 6 Li data will be collected to provide new inputs for evaluation of the 239 Pu(n,f) cross section.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Smart TPC

This introduces Smart TPC to reduce data volume in any TPC detector by implementing an AI/ML model on ASICs or FPGAs.

Seo, Sunny [Fermilab]↗

Monitoring the readout temperature in the ICARUS TPC (2023 Italian Students Program Final Report)

Being a Liquid Argon Time Projection Chamber (LAr-TPC) detector, ICARUS exploits a series of three parallel wire planes to measure and collect the ionization charge coming from an event inside the active volume. The wires are read out by A2795 custom boards, arranged in crates located on top of the two liquid Argon vessels. Each board is provided with two temperature sensors that allow temperature monitoring while the experiment is running: this is key in order to ensure data reliability and maintain hardware in safe conditions. Moreover, temperature-related problems may force unplanned shutdowns that result in losing valuable time for the experiment to run. In this work we are discussing the characterization of the ICARUS TPC board temperatures and the system we implemented in order to monitor them effectively. Among the tools used, Grafana results in a valid application for both displaying temperature data and sending alerts to the shifters whenever a pathological situation occurs.

42 ENGINEERING↗

Exclusive muon neutrino charged current pion-less topologies. ArgoNeuT results and future prospects in LAr TPC detectors

Results from the analysis of charged current pion-less (CC 0-pion) muon neutrino events in argon collected by the ArgoNeuT experiment on the NuMI beam at Fermilab are presented and compared with predictions from Monte Carlo simulations. A novel analysis method, based on the reconstruction of exclusive topologies, fully exploiting the Liquid argon Time Projection Chamber (LAr TPC) technique capabilities, is used to analyze the events, characterized by the presence at the vertex of a leading muon track eventually accompanied by one or more highly ionizing tracks, and study nuclear effects in neutrino interactions on argon nuclei. Multiple protons accompanying the leading muon are visible in the ArgoNeuT events, and measured with a proton reconstruction threshold of 21 MeV kinetic energy. As a result, measurements of (anti-)neutrino CC 0-pion inclusive and exclusive cross sections on argon nuclei are reported. Prospects for future, larger mass LAr TPC detectors are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of the cryogenic systems for the Near and Far LAr-TPC detectors of the Short-Baseline Neutrino program (SBN) at Fermilab

The Short-Baseline Neutrino (SBN) physics program at Fermilab and Neutrino Platform (NP) at CERN are part of the international Neutrino Program leading to the development of Long-Baseline Neutrino Facility/Deep Underground Neutrino Experiment (LBNF/DUNE) science project. The SBN program consisting of three Liquid Argon Time Projection Chamber (LAr-TPC) detectors positioned along the Booster Neutrino Beam (BNB) at Fermilab includes an existing detector known as MicroBooNE (170-ton LAr-TPC) plus two new experiments known as SBN’s Near Detector (SBND, ~260 tons) and SBN’s Far Detector (SBN-FD, ~760 tons). All three detectors have distinctly different design of their cryostats thus defining specific requirements for the cryogenic systems. Fermilab has already built two new facilities to house SBND and SBN-FD detectors. The cryogenic systems for these detectors are in various stages of design and construction with CERN and Fermilab being responsible for delivery of specific sub-systems. This contribution presents specific design requirements and typical implementation solutions for each sub-system of the SBND and SBN-FD cryogenic systems.

43 PARTICLE ACCELERATORS↗

High-Pressure Gaseous Argon TPC for the DUNE Near Detector

The DUNE Near Detector design consists of multiple components, each designed to produce complementary constraints on flux and neutrino interaction systematic uncertainties for the oscillation analyses. One of these subdetectors is a magnetized high-pressure gaseous-argon TPC (HPgTPC), which will provide fine-grained tracking in a low-density detector, using the same target nucleus as the DUNE far detector. With its low momentum threshold for particle detection, the HPgTPC will be able to constrain one of the most crucial - and least-well understood - uncertainties for the oscillation analysis: nuclear effects in neutrino-argon interactions. These proceedings describe the current design, physics goals, and projected performance of the HPgTPC, as well as the ongoing R&D work at Fermilab, in which a test-stand TPC is being built and will be operated at up to 10 atm pressure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstruction for Liquid Argon TPC Neutrino Detectors Using Parallel Architectures.

Neutrinos are particles that interact rarely, so identifying them re-quires large detectors which produce lots of data. Processing this data with thecomputing power available is becoming more dicult as the detectors increasein size to reach their physics goals. In liquid argon time projection chambers(TPCs) the charged particles from neutrino interactions produce ionization elec-trons which drift in an electric field towards a series of collection wires, and thesignal on the wires is used to reconstruct the interaction. The MicroBooNEdetector currently collecting data at Fermilab has 8000 wires, and planned fu-ture experiments like DUNE will have 100 times more, which means that thetime required to reconstruct an event will scale accordingly. Modernization ofliquid argon TPC reconstruction code, including vectorization, parallelizationand code portability to GPUs, will help to mitigate these challenges. The liquidargon TPC hit finding algorithm within theLArSoftframework used acrossmultiple experiments has been vectorized and parallelized. This increases thespeed of the algorithm on the order of ten times within a standalone version onIntel architectures. This new version has been incorporated back intoLArSoftso that it can be generally used. These methods will also be applied to otherlow-level reconstruction algorithms of the wire signals such as the deconvolu-tion. The applications and performance of this modernized liquid argon TPCwire reconstruction will be presented.

Berkman, Sophie↗

Performance of a MICROMEGAS-based TPC in a high-energy neutron beam

The MICROMEGAS (MICRO-MEsh GAseous Structure) charge amplification structure has found wide use in many detection applications, especially as a gain stage for the charge readout of Time Projection Chambers (TPCs). We report on the behavior of a MICROMEGAS TPC when operated in a high-energy (up to 800 MeV) neutron beam. It is found that neutron-induced reactions can cause discharges in some drift gas mixtures that are stable in the absence of the neutron beam. The discharges result from recoil ions close to the MICROMEGAS that deposit high specific ionization density and have a limited diffusion time. And for a binary drift gas, increasing the percentage of the molecular component (quench gas) relative to the noble component and operating at lower pressures generally improves stability.

43 PARTICLE ACCELERATORS↗

MWPC prototyping and performance test for the STAR inner TPC upgrade

A new prototype of STAR inner Time Projection Chamber (iTPC) MWPC sector has been fabricated and tested in an X-ray test system. The wire chamber built at Shandong University has a wire tension precision better than 6% and wire pitch precision better than 10 μm. The gas gain uniformity and energy resolution are measured to be better than 1% (RMS) and 20% (FWHM), respectively, using an 55 Fe X-ray source. The iTPC upgrade project is to replace all 24 STAR TPC inner sectors as a crucial detector upgrade for the RHIC beam energy scan phase II program. Furthermore, the test results show that the constructed iTPC prototype meets all project requirements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of TPC Single Sextant U-238/U-235 Engineering In-Beam Data

The Time Projection Chamber is a collaborative effort to implement an innovative approach and deliver unprecedented fission measurements to DOE programs. This 4π- detector system will provide unrivaled 3-D data about the fission process. This TPC has been shipped and installed at LANSCE and is collecting further engineering data for the full system scale up next year.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Readout of TPC Tracking Chambers with GEMs and Pixel Chip

Two layers of GEMs and the ATLAS Pixel Chip, FEI3, have been combined and tested as a prototype for Time Projection Chamber (TPC) readout at the International Linear Collider (ILC). The double-layer GEM system amplifies charge with gain sufficient to detect all track ionization. The suitability of three gas mixtures for this application was investigated, and gain measurements are presented. A large sample of cosmic ray tracks was reconstructed in 3D by using the simultaneous timing and 2D spatial information from the pixel chip. The chip provides pixel charge measurement as well as timing. These results demonstrate that a double GEM and pixel combination, with a suitably modified pixel ASIC, could meet the stringent readout requirements of the ILC.

43 PARTICLE ACCELERATORS↗

First proof of topological signature in the high pressure xenon gas TPC with electroluminescence amplification for the NEXT experiment

The NEXT experiment aims to observe the neutrinoless double beta decay of xenon in a high-pressure 136 Xe gas TPC using electroluminescence (EL) to amplify the signal from ionization. One of the main advantages of this technology is the possibility to reconstruct the topology of events with energies close to Q ββ . This paper presents the first demonstration that the topology provides extra handles to reject background events using data obtained with the NEXT-DEMO prototype. Single electrons resulting from the interactions of 22 Na 1275 keV gammas and electron-positron pairs produced by conversions of gammas from the 228 Th decay chain were used to represent the background and the signal in a double beta decay. Furthermore, these data were used to develop algorithms for the reconstruction of tracks and the identification of the energy deposited at the end-points, providing an extra background rejection factor of 24.3 ± 1.4 (stat.)%, while maintaining an efficiency of 66.7 ± 1% for signal events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electroluminescence pulse shape and electron diffusion in liquid argon measured in a dual-phase TPC

Here, we report the measurement of the longitudinal diffusion constant in liquid argon with the DarkSide-50 dual-phase time projection chamber. The measurement is performed at drift electric fields of 100 V/cm, 150 V/cm, and 200 V/cm using high statistics $^{39}$Ar decays from atmospheric argon. We derive an expression to describe the pulse shape of the electroluminescence signal (S2) in dual-phase TPCs. The derived S2 pulse shape is fit to events from the uppermost portion of the TPC in order to characterize the radial dependence of the signal. The results are provided as inputs to the measurement of the longitudinal diffusion constant DL, which we find to be (4.12 $\pm$ 0.04) cm$^2$/s for a selection of 140keV electron recoil events in 200V/cm drift field and 2.8kV/cm extraction field. To study the systematics of our measurement we examine datasets of varying event energy, field strength, and detector volume yielding a weighted average value for the diffusion constant of (4.09 $\pm$ 0.09) cm$^2$ /s. The measured longitudinal diffusion constant is observed to have an energy dependence, and within the studied energy range the result is systematically lower than other results in the literature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cold electronics readout system for protoDUNE-SP LAr-TPC

The Single Phase (SP) TPC readout electronics are referred to as the Cold Electronics (CE) because they will operate in LAr, to minimize channel capacitance and noise by keeping the length of the connection between the anode wires and its corresponding electronics input to an absolute minimum. In this study, the CE system and preliminary results from the CE testing at warm and cold conditions after their installation on the protoDUNE-SP detector are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Yale Lar TPC

In this paper we give a concise description of a liquid argon time projection chamber (Lar TPC) developed at Yale, and present results from its first calibration run with cosmic rays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ArgoNeuT: a liquid Argon TPC for the study of v interactions in the intermediate energy range

The next generation of long baseline neutrino oscillation experiments, aiming at precision measurements of the MNSP matrix element, will be focused on the 'few GeV' energy range. For these experiments one of the main sources of uncertainty is the poor knowledge of the v-nucleus interaction cross-section, dominated in this energy range by the QE channel contribution. The LAr-TPC technology is ideal to perform a wide variety of v-physics studies in the intermediate energy range, thanks to the capability of single particle identification and detailed reconstruction of exclusive topologies. The present paper reports a feasibility study for the measurement of the QE CC cross-section for the v{sub {mu}}-nucleus interaction in liquid Argon, using the ArgoNeuT detector on the NuMI Beam and the MINOS Near Detector as muon catcher. The estimated relative statistical error between 1 and 4 GeV is at the level of 4-5%, below the beam systematics. The present status of the ArgoNeuT experiment is also reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Micromegas TPC for Low Energy Heavy Ions Measurement for Nuclear Fission and Astrophysics Applications

Time Projection Chambers are widely used since many years for tracking and identification of charged particles in high energy physics. We present a new R and D project to investigate the feasibility of a Micromegas TPC for low energy heavy ions detection. Two physics cases are relevant for this project. The first is the study of the nuclear fission of actinides by measuring the fission fragments properties (mass, nuclear charge, kinetic energy) that will be performed at different installations and in particular at the NFS facility to be built in the framework of the SPIRAL2 project in GANIL. The second physics case is the study of heavy ion reactions, like ({alpha},{gamma}), ({alpha},p), ({alpha},n) and all the inverse reactions in the energy range between 1.5 and 3 AMeV using both stable and radioactive beams. These reactions have a key role in p process in nuclear astrophysics to explain the synthesis of heavy proton-rich nuclei. Within the project, a large effort is devoted to Monte-Carlo simulations and a detailed benchmark of different simulation codes on the energy loss and range in gas of heavy ions at low energy has been performed. A new approach for simulating the ion charge state evolution in GEANT4 is also presented. Finally, preliminary results of an experimental test campaign on prototype are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗