Search NASA⌕ Search

SEARCH · Search NASA

Results for “TRACE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Coupling TRACE with nodal neutronics code Ants using the Exterior Communications Interface and VTT's multi-physics driver Cerberus

In this paper a recently developed coupling between system code TRACE and nodal neutronics code Ants is presented. The TRAC/RELAP Advanced Computational Engine (TRACE) is a reactor system code developed by U.S. Nuclear Regulatory Commission (NRC). The code has been designed to analyse loss-of-coolant accidents (LOCAs), operational transients and other accident scenarios in light water reactors. Ants is the reduced order nodal neutronics code of the Kraken framework. The diffusion solution method in Ants is based on the Analytic Function Expansion Nodal method (AFEN) and Flux Expansion Nodal Method (FENM). Rectangular, hexagonal and triangular geometries are supported. Both steady state and burnup problems including micro-depletion can be simulated. The coupling is implemented using VTT's multi-physics driver Cerberus and the Exterior Communications Interface (ECI) which is supplied with TRACE and enables the coupling of TRACE without source code modifications. The main focus in the paper is on describing the TRACE-Ants coupling in detail in order to share to other code developers what we have learned from the ECI based coupling process. The coupled code system is briefly tested by simulating a simple transient in a SMR core initiated by control rod movement. The results of the test calculation look reasonable and more complicated test cases will be modelled in the near future.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effect of fluctuating redox conditions on trace metal release from wetland soils from South Carolina and stream sediments from Tennessee

Natural aquatic systems undergo fluctuating redox conditions due to microbial activity, varying water saturation levels, and nutrients dynamics. With fluctuating oxic and anoxic conditions, trace metals can be mobilized or sequestered in response to changes in iron and sulfur speciation and the concentrations and lability of organic carbon. We conducted a systematic laboratory-based microcosm study to examine the effect of redox fluctuations on trace metal mobility in samples collected from two different natural aquatic systems: riparian wetlands and a stream. We incubated water-saturated soils under three cycles of anoxic-oxic conditions (τanoxic:τoxic = 3) spanning 24 days and monitored the change in dissolved and bioavailable metal (copper (Cu), nickel (Ni), zinc (Zn), cobalt (Co), iron (Fe), and manganese (Mn)) concentrations. The dataset includes the results of the variation in metal concentrations due to redox fluctuations in wetland soils and stream sediments. Additionally, the variation in the bioavailable concentration of metals obtained using passive samplers based on diffuse gradient in thin-films technique is included in the dataset. We have also reported the change in the pH values and dissolved oxygen concentrations in the microcosms during the entire study of 24 days. The dataset also contains the dissolved organic carbon and sulfate concentrations, and the data on fractions of metals bound to reducible and oxidizable phases. For materials from both the wetlands and the stream, anoxic conditions favored Co and Zn release, which corresponded with the reductive dissolution of iron oxides. In contrast, dissolved Cu concentrations increased under oxic conditions for both sites and correlated positively with the release of sulfate. In wetland soils, dissolution of Fe (hydr)oxides increased Ni solubility; however, in stream sediments, Ni release occurred when sulfides or organic matter were oxidized. For stream sediments, each subsequent redox cycle increased the bioavailability of trace metals. Upon redox fluctuations in wetland soils, the bioavailability of Zn and Cu increased, whereas bioavailable Ni and Co decreased. This study illustrates that different trace metals display distinct bioavailability patterns during oxic-anoxic fluctuations in natural environments. The biogeochemical cycling of carbon and nitrogen in systems with redox fluctuations may be influenced by these patterns in trace metal availability in addition to the availability of electron donors and acceptors.

54 ENVIRONMENTAL SCIENCES↗

Exploring the Impact of N Solubility and Trace Elements on the Creep Properties of P92 Steel

Trace elements can have major consequences on the properties of creep resistant martensitic steels. To better understand the changes in microstructure and mechanical performance associated with the variation of trace elements and enable design of steels operating at more demanding conditions, we formulated three versions of P92 within the specified allowable N, B, C and Si ranges. Different service conditions were explored, and >80% decrease in creep life was observed at 625°C 155MPa for the highest B and N containing alloy. Multiscale characterization (OM, SEM, TEM) revealed key changes due to the trace element variation. The high trace content alloy formed deleterious BN precipitates with morphology that would promote crack nucleation, but also formed higher fractions of beneficial MX precipitates. The alloy with the lowest trace content showed the best creep performance – a result of the refined precipitate populations and the absence of large-scale inclusions and BN precipitates.

Antonov, Stoichko↗

Trace Chemical Detection Using Intercalated MXenes as a Signal Enhancing Substrate in Optical Probes

MXenes are 2D materials composed of layered transition metal nitrides or carbides. These materials are synthesized by HF exfoliation from MAX phases (Ti{sub 3}AlC{sub 2}). The 2D nanomaterial was synthesized by the removal of the 'A' element, resulting in a Mxene product (Ti{sub 3}C{sub 2}). MXenes have the general formula M{sub n+1}X{sub n}T{sub x}, where M is an early transition metal, X is Carbon and/or Nitrogen, and T accounts for surface terminated functional groups such as Fluoride, hydroxyl, and oxygen. These materials have very unique properties, similar to graphene, that allows them to be applied in a variety of trace detection techniques including surface-enhanced Raman spectroscopy (SERS). MXenes have also been demonstrated to selectively uptake uranyl ion, UO{sub 2}{sup 2+}. If this property can be combined with SERS or fluorescence detection, it may be possible to use MXenes as the basis for an alternative method to kinetic phosphorescence analysis (KPA) for trace uranyl measurements. Objectives: To confirm that MXene Nano materials are suitable substrates for SERS and sensor development by enhancing Raman signaling. To determine if certain MXene preparation methods yield materials that are more suitable for trace sensing methods. To determine uranyl uptake properties of these MXene materials and test them for analytical signals. Sample Preparation: Preparation of Ti{sub 3}C{sub 2}MXene (at FSU). MXenes were prepared by etching Al from Ti{sub 3}AlC{sub 2} (MAX phase)material. Two etching techniques yield different MXene products: LiF/HCl: Milder reaction, larger MXene flakes. HF: Harsher reaction, smaller flakes, larger layer separation. Products washed to remove etchant, vacuum filtered, and dried. Dried MXene flakes are air-stable. Film preparation for sensor testing (at SRNL): Suspend powder in diH{sub 2}O, purge with Ar, sonicate for 30 min. Centrifuge and collect supernate with suspended particles. Observed LiF-etched Mxene yielded a higher density of particles and darker collected solution. Drop-cast (4 ml) supernate onto slides and dried with Ar. For Rhodamine B (RhB) testing, drop-cast 4 ml drops onto Mxene spots and dried with Ar. Scanning Electron Microscopy conditions: 10 kV Beam energy, high vacuum; Working distance of 8 mm; beam penetration depth appx. 4 microns, beam spot size appx. 2 nanometers. Results: Detection of aluminum correlates with bright spots on image. Presence of aluminum shows that LiF/HCl etching was less thorough than HF etching. Trace Cl detection in LiF images suggests incomplete rinsing. HF has smaller feature size, more layer structure, and increased homogeneity, consistent with expectations. Macroscopic Raman spectroscopy measurements: 532 nm excitation, ∼50 mW with a ∼100 micron spot size (InPhotonics RPB probe). Kaiser Optical Holospec f/1.8 spectrometer with cooled (-60 deg.C) Andor iDus OE420 CCD. LiF 1x supernate showed good signal for trace measurements of Rhodamine B. HF and 1/4x LiF supernates showed little Mxene or Rhodamine B signal. Low deposition densities led to excess background signal from glass slides. For LiF film, response is linear with Rhodamine B concentration over range tested. Will retest with Raman microscope (∼1 micron spot size) to characterize SERS of more dilute LiF and HF etched Mxenes. Conclusions: The LiF etched material was more suitable for macroscopic SERS measurements because it was more concentrated, resulting in a thicker film than the HF etched Mxene and diluted LiF sample. However, the other materials may give greater SERS enhancements, which we hope to determine from measurements with the Raman microscope. From characterization with SEM we concluded that the HF etched Mxene is more uniform/homogenous and has smaller particle size than the LiF etched Mxene. There is still aluminum present in both samples indicating that etching wasn't complete, but the removal of the aluminum was more efficient in the HF method. Path Forward: Observe SERS with Raman microscopy, to obtain better signals for the more diluted samples and be able to compare enhancement effects for the different MXenes. Characterize uranyl sorption into MXene films and test Raman and fluorescence signals. Revisit the etching conditions to improve removal of aluminum. FSU and SRNL will continue to collaborate to create and characterize different Mxene materials and test their usefulness for sensor applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Selective Electrochemical Reduction of CO 2 to Metal Oxalates in Nonaqueous Solutions Using Trace Metal Pb on Carbon Supports Enhanced by a Tailored Microenvironment

In this work, the electroreduction of carbon dioxide (CO 2 ) to oxalate is enabled by incorporating trace metallic lead (Pb) on carbon‐based supports (CBS) with polymer overlayers. These composite materials serve as an efficient electrocatalytic system for the facile conversion and storage of CO 2 , a pernicious atmospheric pollutant. Results from controlled potential electrolysis experiments indicate that 1) trace metallic Pb on the ppb scale is active toward the reductive coupling of CO 2 to oxalate at comparable Faradaic efficiencies to bulk metallic Pb and 2) polymer encapsulation of this trace metallic Pb leads to promotion of CO 2 reduction (CO 2 R) selectively to metal oxalates over other products such as CO. Importantly, metal oxalates are important alternative cementitious materials and precursors for other materials’ synthesis applications. The solid products undergo rigorous spectroscopic characterization, including 13 CO 2 labeling experiments, to ensure the metal oxalates are in fact produced from CO 2 R. These findings serve as a model for leveraging microenvironment effects to enhance activity and selectivity for CO 2 R using trace‐metal catalysts for carbon utilization and storage technologies.

alternative cementitious materials↗

Quasi-optical beam tracing module development for millimeter-wave high-wavenumber collective scattering on the NSTX-U and EAST tokamaks

A Python3-based beam tracing code utilizing Quasi-Optics has been developed to track both incident and receiving beams in high-k collective millimeter wave scattering systems within magnetic fusion plasmas. In contrast to existing ray tracing codes that solely consider refraction, this beam tracing code incorporates diffraction phenomena, providing a more comprehensive calculation. Here, this enhanced capability allows for a more accurate calculation of the scattering volume and spatial resolution in high-k collective scattering systems, crucial for evaluating system performance and facilitating data analysis. Unlike Geometrical Optics, Quasi-Optics employs the complex eikonal method, representing a Gaussian beam as a collection of coupled rays to accurately preserve diffraction characteristics. The developed code is intended for application in NSTX-Upgrade and EAST high-k beam tracing analyses, targeting frequencies of 693 GHz and 270 GHz, respectively. The high-k system's primary objective is the observation of electron-scale instabilities. Employing a symplectic integrator, the code ensures numerical accuracy, assessed through the conservation of the Hamiltonian. With its precision and efficiency, the code facilitates rapid inter-shot analyses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of trace level As or Ni on pyrite formation kinetics at low temperature

Pyrite formation at low temperature during early diagenesis in (sub-)surface sediments is an essential step of Fe and S biogeochemical cycles and the presence of this ubiquitous mineral of surface environments is often used as an indicator of paleo-redox conditions. Pathways of pyrite formation are usually discussed in environmental settings by involving a variety of nanosized Fe-S mineralogical precursors as a function of the local geochemical conditions. However, the influence of trace element impurities such as Ni and As in the solution at the time of pyrite formation has been poorly studied, whereas specific chemical signatures of trace elements are commonly observed in sedimentary pyrites. Here, a better understanding of the impact of Ni and As incorporation at trace levels on pyrite formation is essential to help refining the use of these elements as paleo-redox indicators and to evaluate the role of pyrite as a sink regulating the biogeochemical cycle of potentially toxic trace elements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dirac traces and the Tutte polynomial

Perturbative calculations involving fermion loops in quantum field theories require tracing over Dirac matrices. A simple way to regulate the divergences that generically appear in these calculations is dimensional regularisation, which has the consequence of replacing 4-dimensional Dirac matrices with d-dimensional counterparts for arbitrary complex values of d. In this work, a connection between traces of d-dimensional Dirac matrices and computations of the Tutte polynomial of associated graphs is proven. The time complexity of computing Dirac traces is analysed by this connection, and improvements to algorithms for computing Dirac traces are proposed.

Renormalization and Regularization↗

Trace elements and their isotopes in streams and rivers

The occurrence and speciation of trace elements in streams and rivers are controlled by interconnected hydrogeological, biogeochemical, and anthropogenic factors that include rock weathering, climate, vegetation, and land use within the watershed. This chapter provides a broad overview of trace element abundance, speciation, and mobility in streams and rivers, including an assessment of how trace elements are partitioned into dissolved, colloidal, and particulate phases. We also discuss how trace elements are mobilized into stream networks and transformed during transport. Select isotopic systems are reviewed to provide examples of how isotopic analyses can be used to understand geochemical and anthropogenic processes.

Herndon, Elizabeth [ORNL] (ORCID:0000000291945493)↗

Analysis of dislocation configurations in SiC crystals through X-ray topography aided by ray tracing simulations

Silicon carbide as a wide bandgap semiconductor is of great research interest for its widespread deployment in a range of electronic and optoelectronic devices, particularly in power electronics. However, defects in silicon carbide crystals are still major concerns that is hampering the development of high-performance devices. X-ray topography, particularly using the synchrotron beam has been instrumental in characterizing and analyzing defect configurations in silicon carbide crystals to optimize crystal growth as well as understand the effect of defects on device performance. Here, in recent years, the use of ray-tracing simulation technique based on the orientation contrast mechanism to simulate contrast of defects observed on actual X-ray topographs has proven to be an effective approach to investigate the nature of crystallographic defects in various semiconductors. This review discusses the principle of ray-tracing simulation and its application and modifications to incorporate the effects of surface relaxation and photoelectric absorption to better simulate different dislocations observed in 4H–SiC as well as 6H–SiC crystals of various orientations. The adaptation to weak beam topography and plane wave topography is also discussed. The application of ray-tracing simulation in dislocation characterization of silicon carbide of different polytypes is systematically reviewed including different types of dislocations observed in both off-axis wafers and axial-sliced samples through synchrotron X-ray topography under various beam conditions, recording geometries and reflections. The result of ray-tracing simulation is further utilized in other studies including the investigation of effective penetration depth of all types of dislocations lying on the basal plane on grazing-incidence X-ray topography.

Engineering↗

Rapid and automated separation of uranium ore concentrates for trace element analysis by inductively coupled plasma – optical emission spectroscopy/triple quadrupole mass spectrometry

The present study documents an automated approach to performing elemental analysis on a large group uranium ore concentrate (UOC) samples. In this work, 17 UOC samples, 2 quality control samples, and 26 process blanks were purified sequentially through a single 500 μL Uranium and TEtra Valent Actinides (UTEVA®) column. For each sample, the trace elemental impurities were separated from its dissolved uranium matrix on the UTEVA column and collected for analysis by inductively coupled plasma – optical emission spectroscopy / triple quadrupole mass spectrometry (ICP-OES/TQMS). The UTEVA column was subsequently regenerated prior to separation of the following sample. The column was efficiently regenerated, for each UOC, even after processing ~50 mg of uranium, cumulatively. The validity of the method was established by determining the trace impurities of two quality control uranium reference samples (CRM 124–1 and CUP-2). The current trace element measurements from the 17 UOC samples were compared to previously reported values from an interlaboratory comparison exercise, when available. The methodology employed here produces trace elemental analysis with excellent correlation to the previously reported data for many of the elements / samples, particularly when viewed through the context of existing geochemical comparisons tools (e.g. chondrite normalized variation plots).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid quantitative analysis of trace elements in plutonium alloys using a handheld laser-induced breakdown spectroscopy (LIBS) device coupled with chemometrics and machine learning

Here, we present the first reported quantification of trace elements in plutonium via a portable laser-induced breakdown spectroscopy (LIBS) device and demonstrate the use of chemometric analysis to enhance the handheld device's sensitivity and precision. Quantification of trace elements such as iron and nickel in plutonium metal via LIBS is a challenging problem due to the complex nature of the plutonium optical emission spectra. While rapid analysis of plutonium alloys has been demonstrated using portable LIBS devices, such as the SciAps Z300, their detection limits for trace elements are severely constrained by their achievable pulse power and length, light collection optics, and detectors. In this paper, analytical methods are evaluated as a means to circumvent the detection constraints. Three chemometric methods often used in analytical spectroscopy are evaluated; principal component regression, partial least-squares regression, and artificial neural networks. These models are evaluated based on goodness-of-fit metrics, root mean-squared error, and their achievable limits of detection (LoDs). Partial least squares proved superior for determining content of iron and nickel in plutonium metal, yielding LoDs of 15 and 20 ppm, respectively. These results of identifying the undesirable trace elements in plutonium components are critical for applications such as fabricating radioisotope thermoelectric generators or nuclear fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantification of trace iodine using laser-induced breakdown spectroscopy for real-time monitoring of nuclear off-gas streams

This study evaluated the potential of laser-induced breakdown spectroscopy (LIBS) for real-time monitoring of trace gas-phase iodine, which is an element of high significance in nuclear applications due to its long radioactive half-life (as iodine-129), volatility, and biological impact. In anticipation of iodine evolving into off-gas systems in molten salt reactor and nuclear fuel recycling applications, this research aimed to assess LIBS performance in flowing argon and helium matrices; optimize measurement parameters using a multichannel spectrometer; and perform calibrations to assess predictive capabilities and limits of detection (LODs). Experimental results successfully measured gas-phase iodine in flowing argon and helium; however, trace iodine was not detected in air. Optimal delay times were determined to be 10 µs for argon and 1 µs for helium, which are consistent with the expected shorter plasma lifetime in helium relative to argon. An emission line survey was provided with the 206.16, 804.37, 902.24, and 905.83 nm peaks, which were identified as the strongest emission peaks. Calibration models were successfully built in both helium and argon, achieving LODs down to 3 ppm in helium and 5 ppm in argon. The iodine emission at 905.83 nm emerged as the most robust for calibration and was subsequently applied to a time series dataset in argon. The predictive trace confirmed the feasibility of employing LIBS for continuous, online quantification of trace iodine in flowing gas systems.

Andrews, Hunter B. [Oak Ridge National Laboratory ↗

Trace Anomaly as Signature of Conformality in Neutron Stars

We discuss an interpretation that a peak in the sound velocity in neutron star matter, as suggested by the observational data, signifies strongly coupled conformal matter. Here, the normalized trace anomaly is a dimensionless measure of conformality leading to the derivative and the nonderivative contributions to the sound velocity. We find that the peak in the sound velocity is attributed to the derivative contribution from the trace anomaly that steeply approaches the conformal limit. Smooth continuity to the behavior of high-density QCD implies that the matter part of the trace anomaly may be positive definite. We discuss a possible implication of the positivity condition of the trace anomaly on the M–R relation of the neutron stars.

79 ASTRONOMY AND ASTROPHYSICS↗

MemGaze: Rapid and Effective Load-Level Memory Trace Analysis

A major challenge of memory analysis tools is combining high-resolution analysis and low overhead measurement. Currently, hardware/software-based analysis of load-level sequences incurs time slowdowns of O(100×). We present MemGaze, a tool for low-overhead, high-resolution memory analysis. MemGaze uses Intel’s Processor Tracing (PT) instruction ptwrite to collect sampled and compressed memory address traces for load-level, sequence-aware analysis of data reuse. We describe multi-resolution analysis for locations vs. operations, accesses vs. spatio-temporal reuse, and reuse (distance, rate, volume) vs. access patterns. Both trace size and resolution are controllable. We use MemGaze to elucidate the memory effects of different data structures and algorithms. For sampled traces that are ˜1% of a full one, analysis metrics have 1-25% MAPE for histograms of varying dynamic sequence lengths. With current suboptimal kernel support (PT runs continuously), MemGaze’s time overhead is typically 10–95%; 7× at worst. However, when PT runs only during samples, overhead is 10–35% on memory intensive regions and correlates with executed ptwrites.

Kilic, Ozgur O.↗

Trace Metal Content and Speciation, Water and Soil Chemistry, and Methane Production for a Wetland in Missouri (September 2015) and in Florida (January 2016)

Data is associated with a manuscript in preparation for submission to explore whether low trace metal availability inhibits methane production in freshwater wetland soils. Reported data are from two field sites, one in Missouri and the second in Florida (see location data). At each site, surface water compositions and properties and soil compositions are reported. Trace metal availability is assessed via sequential chemical extractions, Ni K-edge X-ray absorption near edge structure (XANES) spectroscopy, and X-ray microfluorescence imaging. Soil mineralogy is determined via powder X-ray diffraction. Multi-energy X-ray microfluorescence imaging as well as bulk and microscale S K-edge XANES spectra assess sulfur speciation in the soils. This package also reports data from trace metal amendment experiments, specifically methane (CH4) production versus time in soil incubations, the dissolved trace metal concentrations in these incubations, and the Ni K-edge XANES and extended X-ray absorption fine structure (EXAFS) spectra of soils to which increasing concentrations of Ni were added. A final version of this package will be published upon acceptance of the associated manuscript.

54 ENVIRONMENTAL SCIENCES↗

Coupling of CTF and TRACE for Modeling of Transients

This report documents the improvements that have been made to the capabilities for coupling CTF to systems codes-specifically, the US Nuclear Regulatory Commission (NRC) TRACE code. An initial systems coupling capability had been set up previously using a nonoverlapping domain approach with the codes exchanging data at the core boundaries. The present work adds a new approach using overlapping domains, in which the system code models the core as well. A new input format has been added to allow the user to specify the physical quantities to be exchanged and their location in the system model, which gives the flexibility of applying one-way or two-way coupling between the codes using the desired data exchanges. In addition to applying thermal-hydraulics (T/H) boundary condition (BC) values obtained from TRACE, a capability was added to allow CTF to apply flow resistance feedback to TRACE to match the CTF core pressure drop. Support was added for executing parallel CTF models within the CTF-systems coupling. The system coupling capability was successfully applied to a parallel MSLB transient, demonstrating that both the one-way and two-way coupling behaved as expected and provided substantial improvements to numerical stability and routine compared to the previous nonoverlapping domain coupling. An initial capability was also developed for performing restart calculations in CTF which will be used in the future for restarting CTF-TRACE simulations at specific points in the transient simulation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An Integrated Framework for Memory-Centric Analysis: From Trace Collection to Co-Design

The memory wall phenomenon—where advances in processor performance significantly outpace those in memory subsystems—poses a fundamental challenge for contemporary computing systems. In memory-bound applications, memory subsystem behavior dominates performance, yet existing analysis approaches present significant limitations: detailed microarchitectural simulators require days to weeks to simulate modest workloads; hardware performance counters provide only aggregate statistics that obscure temporal and spatial access patterns; and scaled simulation approaches face challenges in capturing certain behaviors that emerge at larger scales. These limitations reflect a processor-centric design philosophy increasingly misaligned with memory-bound workloads where detailed understanding of memory access patterns, cache hierarchy interactions, and contention is critical for effective optimization. This paper presents an integrated framework for memory-centric analysis that enables effective hardware-software co-design. We describe practical trace collection techniques, including hardware-assisted processor tracing with minimal overhead and portable software-based instrumentation with statistical sampling. We present multi-perspective analysis methods that examine memory behavior from temporal, sequential, spatial, and relational viewpoints, revealing distinct optimization opportunities invisible in aggregate metrics. We detail an architectural modeling framework that uses sampled traces with temporal interpolation and confidence-based filtering to evaluate cache and memory configurations. Evaluation on representative benchmarks demonstrates that this framework achieves practical accuracy (L2 cache errors of 2.64\%, confidence-filtered L3 errors of 9.92\%, bandwidth errors of 7.33\%) while providing substantial speedup (26.8×) over cycle-accurate simulation, enabling rapid design space exploration. We demonstrate how this integrated framework enables systematic identification of both hardware optimizations (memory controller tuning, bank partitioning, NUMA configuration) and software optimizations (data layout restructuring, prefetching strategies, memory-aware scheduling). Through this comprehensive treatment of the memory-centric analysis pipeline—from trace collection through architectural modeling to co-design application—we provide researchers and practitioners with practical techniques for addressing memory bottlenecks in contemporary computing systems.

Gajaria, Dhruv Mayur↗