Search NASA⌕ Search

SEARCH · Search NASA

Results for “TRACKING SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Supervisory Control and Data Acquisition for Electrochemical Separation Experimentation

The Python-based program is a laboratory automation tool designed to control and monitor electrochemical systems. The tool was developed for capacitive deionization (CDI) experiments, but it can be used for any system that requires controlled voltage or current segments and multi-parameter monitoring. The program integrates hardware components to run user-defined experimental parameters, providing operational control of a programmable power supply, peristaltic pump, and data acquisition devices. Currently, the program is structured with a workflow that includes an initialization (or pre-run) phase, a main loop, and a post-experiment stabilization (or post-run) phase. The initialization phase prepares and stabilizes the cell, ensuring that the electrodes and solution reach a baseline state before the experiment begins. The main loop consists of multiple voltage segments that repeat, controlling the experiment while recording key parameters such as time, voltage, current, pH, and conductivity. Finally, the post-experiment stabilization phase allows the system to stabilize after the experiment, returning the cell and solution to equilibrium conditions before ending the sequence. The program is designed with four variations, each tailored to different experimental needs. All variations include both the initialization and post-experiment stabilization stages, which run for a set amount of time, voltage, current, and flow rate before and after the main experiment block. The main loop runs for a set number of cycles, as defined by the user input, and each cycle is composed of 2 or 4 segments. The 4 program variations are described as follows: Program 1: The main program includes 2 segments. Each segment is defined to have a set duration, flow rate, voltage, and current. This program measures conductivity, flow rate, voltage, and current. Program 2: The main program expands Program 1 to include 4 segments. Each segment has a specified duration, flow rate, voltage, and current. Like Program 1, it measures conductivity, flow rate, voltage, and current. Program 3: The main program consists of 2 segments, each defined by time, flow rate, voltage, and current. In addition to conductivity, flow rate, voltage, and current, Program 3 collects pH and temperature data through a 4-channel data acquisition device. Program 4: This program independently controls two channels of a multi-channel power supply simultaneously. While conductivity can only be measured for one cell at a time, the dual-channel control makes it possible to operate two cells simultaneously under different voltage/current conditions. The main program includes 2 segments.For each program, all measurements are automatically logged and integrated into a single Excel output file. Data are displayed in numerical format and plotted, both in real time, to track system performance. A key feature of the program is its ability to synchronize all outputs so that every measurement shares a single timestamp, ensuring accurate alignment of voltage, current, pH, conductivity, and pH data.By combining hardware control, real-time monitoring, and unified data collection, this program significantly reduces manual workload and minimizes errors, making it a reliable platform for researchers, engineers, and laboratory technicians conducting CDI experiments, among other electrochemical tests.

Valentino, Lauren [Argonne National Laboratory (AN↗

Results for pixel and strip centimeter-scale AC-LGAD sensors with a 120 GeV proton beam

Here, we present the results of an extensive evaluation of strip and pixel AC-LGAD sensors tested with a 120 GeV proton beam, focusing on the influence of design parameters on the sensor temporal and spatial resolutions. Results show that reducing the thickness of pixel sensors significantly enhances their time resolution, with 20-μm-thick sensors achieving around 20 ps. Uniform performance is attainable with optimized n + sheet resistance, making these sensors ideal for future timing detectors. Conversely, 20-μm-thick strip sensors exhibit higher jitter than similar pixel sensors, negatively impacting time resolution, despite reduced Landau fluctuations with respect to the 50-μm-thick versions. Additionally, it is observed that a low resistivity in strip sensors limits signal size and time resolution, whereas higher resistivity improves performance. This study highlights the importance of tuning the n+ sheet resistance and suggests that further improvements should target specific applications like the Electron–Ion Collider or other future collider experiments. In addition, the detailed performance of four AC-LGADs sensor designs is reported as examples of possible candidates for specific detector applications. These advancements position AC-LGADs as promising candidates for future 4D tracking systems, pending the development of specialized readout electronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Filling the gap: hunting for vector bosons at the MUonE experiment with displaced decay signature

The upcoming MUonE experiment aims to precisely measure the running of the fine structure constant via elastic muon-electron scattering, to shed light on the current tension in the muon’s anomalous magnetic moment. In addition to its primary function as a precision experiment, MUonE also offers a unique testing ground to probe long-lived vector bosons. Such vector bosons can be produced via μe → μeV or μN → μNV scattering and decay into an electron/positron pair a few centimeters away from the interaction point. With its high-resolution tracking system and unique geometric design, MUonE is well-suited to reconstruct displaced vertices close to the target, allowing it to probe parameter space previously unattainable at colliders and longer-baseline beam dump experiments. We present a comprehensive study of the discovery potential of BSM vector boson mediators at the MUonE experiment. We show that MUonE can fill the long-standing gap in the parameter space of vector boson mediators with masses up to around 100 MeV.

Models for Dark Matter↗

The ladder and readout cables of intermediate silicon strip detector for sPHENIX

A new silicon-strip-type detector was developed for precise charged-particle tracking in the central rapidity region of heavy ion collisions. A new detector and collaboration at the Relativistic Heavy Ion Collider at Brookhaven National Laboratory is sPHENIX, which is a major upgrade of the PHENIX detector. The intermediate tracker (INTT) is part of the advanced tracking system of the sPHENIX detector complex together with a CMOS monolithic-active-pixel-sensor based silicon-pixel vertex detector, a time-projection chamber, and a micromegas-based detector. The INTT detector is barrel shaped and comprises 56 silicon ladders. Two different types of strip sensors of 78 micron pitch and 320 micron thick are mounted on each half of a silicon ladder. Each strip sensor is segmented into 8 × 2 and 5 × 2 blocks with lengths of 16 and 20 mm. Strips are read out with a silicon strip-readout (FPHX) chip. In order to transmit massive data from the FPHX to the down stream readout electronics card (ROC), a series of long and high speed readout cables were developed. This document focuses on the silicon ladder, the readout cables, and the ROC of the INTT. The radiation hardness is studied for some parts of the INTT devices in the last part of this document, since the INTT employed some materials from the technology frontier of the industry whose radiation hardness is not necessarily well known.

43 PARTICLE ACCELERATORS↗

Performance Evaluation of an Offshore Wave Measurement Buoy in Monochromatic Waves

The accurate measurement of waves underpins marine energy resource characterization, device design, and project development. Datawell wave buoys are widely deployed and have long served as a trusted standard for wave measurements. We quantify the measurement performance, including wave elevation and energy flux estimation, of a Datawell DWR-MkIII buoy using prescribed monochromatic heave motions on a large-amplitude six-degree-of-freedom motion platform at the National Laboratory of the Rockies, assuming the buoy behaves as an ideal wave follower. Commanded motions were validated with an optical motion tracking system while buoy elevation and raw acceleration were recorded. Wave elevations were propagated to wave energy flux estimation using four methods, including one frequency-domain method and three time-domain methods. The Bayesian optimization was applied for design of experiments, and records from three test sites were also applied and evaluated in the present study. Results show two error regions within the nominal period range of 1.6 s to 30 s. For wave periods between 5 s and 25 s, the buoy provides accurate wave height measurements. For short periods less than 5 s, the 1.28 Hz sampling frequency induces sub-Nyquist artifacts that bias elevation and can drive maximum energy flux estimation errors above 100%. For long periods exceeding 25 s, the buoy reported elevation is underpredicted with error depending on period but relatively independent of wave height, with maximum wave height and wave energy flux errors reaching 64% and 87%, respectively. Furthermore, analysis of three field-derived cases shows that frequency-domain estimates at 1.28 Hz agree within 2% of the corresponding 100 Hz estimates, while larger method-dependent differences are observed for the Hilbert method.

16 TIDAL AND WAVE POWER↗

Spatial variability in Arctic–boreal fire regimes influenced by environmental and human factors

Abstract Wildfire activity in Arctic and boreal regions is rapidly increasing, with severe consequences for climate and human health. Regional long-term variations in fire frequency and intensity characterize fire regimes. The spatial variability in Arctic–boreal fire regimes and their environmental and anthropogenic drivers, however, remain poorly understood. Here we present a fire tracking system to map the sub-daily evolution of all circumpolar Arctic–boreal fires between 2012 and 2023 using 375 m Visible Infrared Imaging Radiometer Suite active fire detections and the resulting dataset of the ignition time, location, size, duration, spread and intensity of individual fires. We use this dataset to classify the Arctic–boreal biomes into seven distinct ‘pyroregions’ with unique climatic and geographic environments. We find that these pyroregions exhibit varying responses to environmental drivers, with boreal North America, eastern Siberia and northern tundra regions showing the highest sensitivity to climate and lightning density. In addition, anthropogenic factors play an important role in influencing fire number and size, interacting with other factors. Understanding the spatial variability of fire regimes and its interconnected drivers in the Arctic–boreal domain is important for improving future predictions of fire activity and identifying areas at risk for extreme events.

Geology↗

Precise magnetic field mapping of the EMPHATIC Phase 1 magnet with COMSOL

A compact Halbach array magnet is used to measure the momentum of the secondary particles in EMPHATIC(Experiment to Measure the Production ofHadrons At a Test beam InChicagoland). Hall probe data was taken for the central cylindrical bore of the magnet and a field map was constructed. COMSOL Multiphysics® Software is used for modeling the magnet and constructing the corresponding magnetic field map. Here, we present a fitting approach where the hall probe data is used to determine a 1mm-spacing map of the entire volume of the magnet using COMSOL. The new map will allow for linear interpolation within the volume, and expand the map to outside the measurement volume, thus increasing the acceptance and precision of EMPHATIC's tracking system.

47 OTHER INSTRUMENTATION↗

Towards high-efficiency particle detection using superconducting microwire arrays

Here, we present a detailed study of an 8-channel 1×1 mm 2 WSi superconducting microwire single photon detector (SMSPD) array exposed to 120 GeV hadron beam and 120 GeV muon beam at the CERN Super Proton Synchrotron H6 beamline. Following up on our first detailed characterization of the efficiency and response of an SMSPD fabricated on a 3 nm WSi film, we report measurements of enhanced particle detection efficiency using a sensor fabricated from a thicker 4.7 nm-thick WSi film. We also report the first SMSPD detection efficiency measurement made for muons. Measurements are enabled by a silicon tracking telescope providing 10 μm in-situ spatial resolution. The results show a fill factor-normalized detection efficiency of 75% and a time resolution of about 130 ps across pixels. These findings represent a significant advancement toward developing high-efficiency SMSPD charged particle tracking systems with simultaneous precision timing, with potential applications in future accelerator-based experiments such as the FCC-ee and Muon Collider.

Cryogenic detectors↗

Direct Reactions and Spectroscopy with Hydrogen Targets at the RIBF

The implementation of MINOS, a liquid-hydrogen target and vertex-tracking system, at the Radioactive Isotope Beam Factory (RIBF) of the RIKEN Nishina Center has led to numerous nuclear physics discoveries. In experiments involving rare-isotope beams at intermediate energies, MINOS was integrated with the DALI2 + γ-ray spectrometer and other auxiliary devices. These were positioned in front of both the ZeroDegree Spectrometer and the SAMURAI magnetic spectrometers for the identification of ejectiles following quasi-free scattering direct reactions. Notable outcomes include the first spectroscopy of unstable doubly magic nucleus, investigations into multi-neutron decays, and the study of shell evolution along isotopic chains. These studies have significantly advanced our understanding of nuclear structure, as well as the mechanism of direct reactions with fast beams. Simultaneously, these direct reactions enabled raising new physics questions and paved the way for next-generation experimental setups to address them. Through the combination of particle- and γ-spectroscopy with a broad range of nuclear reactions, new frontiers will be established in our understanding of nuclear structure and reaction mechanisms. Here, we review the past ten years of studies on direct reactions and spectroscopy of exotic nuclei with liquid-hydrogen targets at the RIBF and define a vision for the future.

Bertulani, Carlos A [East Texas A & M Univ., Comme↗

In situ quantum verification of polarization-stabilized optical channels

The active stabilization of polarization channels is a task of growing importance as quantum networks move to deployed demonstrations over existing fiber infrastructure. However, the uniquely strict requirements for high-fidelity qubit transmission complicate the extent to which classical solutions may apply to future quantum networks, particularly in terms of recognizing noise sources present in low-flux, nonunitary channels. Here we introduce an in situ benchmarking approach that augments a classical polarization tracking system, limited to unitary correction, with simultaneously transmitted quantum light for ancilla-assisted process tomography of the full quantum map. Implemented in a quantum local-area network, our method uses the reconstructed map both to validate the classical compensation and to expose noise sources it fails to capture. A sliding measurement window that continuously updates the estimated quantum process further increases sensitivity to rapid channel fluctuations. Our results should unlock new opportunities for in situ channel characterization in quantum-classical coexistence networks.

Stevens, Matthew L [Arizona State University]↗

Status and prospects for inertial fusion energy via lasers

Fusion energy is the ultimate clean and limitless energy source, but its development requires overcoming many scientific and technological challenges. For the first time in the 60-year long history of fusion research, ignition and target gain above unity (G>1) were demonstrated in the laboratory at the National Ignition Facility at the Lawrence Livermore National Laboratory in 2022. Turning laser fusion into an energy source requires that the results from single shot experiments be replicated at much higher repetition rates of many shots per second to produce high average power at relatively low cost. Furthermore, this requires the development of new laser technologies, mass production of suitable targets, accurate injection and tracking systems and new materials for the reactor chamber components and final optics. Ultra broadband and deep UV light are laser advances that can dramatically improve the laser energy coupling to the target thereby reducing the laser energy and power requirements.

Fusion energy↗

DOE EV Data Collection - Maintenance Data

Maintenance data includes information on maintenance performed on the electric vehicles, including preventive maintenance, service calls, and availability of the vehicles. The parameters collected, and their definitions, will vary due to the differences in maintenance tracking systems that exist between fleets. Parameter definitions are detailed in the data dictionary, and specific vehicle information is available in the vehicle attributes table. Vehicle ID can be used as a key between maintenance data and vehicle attribute tables. Data is being uploaded quarterly through 2023 and subject to change until the conclusion of the project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance of Pixel and Strip AC-LGAD Sensors with Different Design Parameter on a 120 GeV Proton Beam

We present the results of an extensive evaluation of strip and pixel AC-LGAD sensors tested with a 120 GeV proton beam, focusing on the influence of design parameters on the sensor temporal and spatial resolutions. Results show that reducing the thickness of pixel sensors significantly enhances their time resolution, with 20- μm-thick sensors achieving around 20 ps. Uniform performance is attainable with optimized sheet resistance, making these sensors ideal for future timing detectors. Conversely, 20-μm-thick strip sensors exhibit higher jitter than similar pixel sensors, negatively impacting time resolution, despite reduced Landau fluctuations with respect to the 50-μm-thick versions. Additionally, it is observed that a low resistivity in strip sensors limits signal size and time resolution, whereas higher resistivity improves performance. This study highlights the importance of tuning the n+ sheet resistance and suggests that further improvements should target specific applications like the Electron-Ion Collider or other future collider experiments. In addition, the detailed performance of four AC-LGADs sensor designs is reported as examples of possible candidates for specific detector applications. These advancements position AC-LGADs as promising candidates for future 4D tracking systems, pending the development of specialized readout electronics.

Lara, Carlos Pérez↗

Studies of Quark Transport and Hadronization in Nuclei

In this project, we conducted the first measurement of di‑hadron azimuthal correlations in deep inelastic scattering (DIS) off nuclei using the CLAS detector at Jefferson Lab. Using 5 GeV electron‑beam data collected on deuterium, carbon, iron, and lead targets, we extracted di‑pion correlation functions over a broad kinematic range. The results show a monotonic broadening of the correlation peak with increasing nuclear mass, along with pronounced dependencies on the pions’ kinematics. Separately, we implemented an algorithm based on the Kalman filter that achieved the first complete alignment of the CLAS12 central tracking system. In parallel, we developed simulations, algorithms, and performance studies that informed the conceptual designs of the forward hadronic calorimeter Insert and the Zero Degree Calorimeter, both of which are now included in the ePIC detector baseline for the forthcoming Electron Ion Collider.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reassessment of Dose Contributions from the Paducah Cask Special Waste Form Buried in the E-Area Low-Level Waste Facility

During a recent revision to the groundwater and inadvertent human intruder screening analysis report (Aleman and Hamm, 2023), weaknesses within the screening logic were observed resulting in the addition of U-235 being brought back into the list of radionuclides requiring inventory limits within the Paducah Cask special waste form (SWF). In addition, while reviewing the earlier vadose zone transport analysis efforts, an inconsistency was observed in the initial U-235P inventory that was supplied to the Consolidated Waste Tracking System (CWTS) back in 2009.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Neutrally-buoyant balloons experiment – EMRTC 2025

This memo announces the successful execution of the neutrally-buoyant balloon experiment (EMRTC 2025), conducted at New Mexico Institute of Mining and Technology’s Energetic Materials Research and Testing Center (EMRTC) in Socorro, NM between April 3 and May 9, 2025. The experiment aimed to build on EMRTC 2022 balloon experiment through testing the effects of lateral and vertical displacement of release locations in a different terrain than EMRTC 2022. EMRTC 2025 employed dual GPS trackers on each balloon to provide both detailed near-source motion tracking in addition to the low-frequency long-distance trackers used in EMRTC 2022. A total of 156 neutrally-buoyant balloons were released over the week of May 5-9, which was approximately 2.5 times the number released in the EMRTC 2022 campaign. The dual tracking system will allow characterizing complex three-dimensional wind structures close to terrain features and diurnal wind patterns to validate wind and plume dispersion models for treaty verification.

99 GENERAL AND MISCELLANEOUS↗

Towards High-Efficiency Particle Detection Using Superconducting Microwire Arrays

We present a detailed study of an 8-channel $1\times1$~mm$^{2}$ WSi superconducting microwire single photon detector (SMSPD) array exposed to 120~GeV hadron beam and 120~GeV muon beam at the CERN Super Proton Synchrotron H6 beamline. Following up on our first detailed characterization of the efficiency and response of an SMSPD fabricated on a 3~nm WSi film, we report measurements of enhanced particle detection efficiency using a sensor fabricated from a thicker 4.7~nm-thick WSi film. We also report the first SMSPD detection efficiency measurement made for muons. Measurements are enabled by a silicon tracking telescope providing 10~$\mu$m in situ spatial resolution. The results show a detection efficiency of 75\% and a time resolution of about 130~ps across pixels. These findings represent a significant advancement toward developing high-efficiency SMSPD charged particle tracking systems with simultaneous precision timing, with potential applications in future accelerator-based experiments such as the FCC-ee and Muon Collider.

Wang, Christina [Fermilab]↗

Bayesian Optimization of The Relativistic Heavy Ion Collider Luminosity via s * Control

A state-of-the-art jet detector named sPHENIX was proposed, commissioned, and operated at the Rel ativistic Heavy Ion Collider (RHIC) from 2023 to 2025. This detector featured precision tracking and calorime try that enable high-statistics studies of the Quark Gluon Plasma through jet modification, upsilon suppres sion, and open heavy flavor production. The innermost component of the three sPHENIX tracking systems is the Monolithic-Active-Pixel-Sensor-based Vertex Detec tor (MVTX) (Fig. 1), which has an acceptance within | s | < 0.1m of the interaction point (IP).

43 PARTICLE ACCELERATORS↗