Search NASA⌕ Search

SEARCH · Search NASA

Results for “TRANSMISSION EFFICIENCY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Ionisation cross sections of rare-gas atoms by electron impact

A pulsed electron beam and ion extraction method is used to measure normalized values of partial ionization cross sections for rare gases from threshold to 1000 eV. Cross sections obtained for singly ionized species are used to calibrate the mass transmission efficiency of the ion extraction/analyzer/detection system by the relative flow technique, and this mass transmission curve is then used to determine the absolute cross sections of the multiply ionized species. Total ion cross sections are found by summation of the individual partial cross sections with proper weighting for charge.

Krishnakumar, E.↗

Far-field pattern of a coherently combined beam from large-scale laser diode arrays

The far-field pattern of a large-scale amplifier array (LSAA) consisting of a large number (2000) of diode laser amplifiers is numerically simulated, and the power collection efficiencies are determined. Random distributions of phase mismatches, misorientations, and element failures in the LSAA system are considered. Phase mismatches and misorientations of the element amplifiers are found to be the most critical parameters of those affecting the power-collection efficiency. Errors of 0.2 wavelength and 25 percent for phase and diffraction angle, respectively, cause a 10 percent reduction in power-collection efficiency. The results are used to evaluate the concept of space-laser power transmission. It is found that an overall transmission efficiency of 80 percent could be realized with a 5-m-diam. receiver at a distance of 10,000 km when an LSAA transmitter 6 m in diam. is aimed with state-of-the-art pointing accuracy.

Kwon, Jin H.↗

Reduced-Bandwidth Coding for Mobile Communication

Fade-resistant mobile systems use power and spectrum efficiently. Transmission system employs tone-calibrated technique (TCT). Residual carrier used in technique to reduce fading-induced effects and coherently demodulate received signal. TCT potentially efficient in use of power and of frequency spectrum. Coding technique, intended for residual-carrier transmission system, alleviates fading and spectrum crowding that hamper mobile communications.

Davarian, F.↗

Computing Efficiency Of Transfer Of Microwave Power

BEAM computer program enables user to calculate microwave power-transfer efficiency between two circular apertures at arbitrary range. Power-transfer efficiency obtained numerically. Two apertures have generally different sizes and arbitrary taper illuminations. BEAM also analyzes effect of distance and taper illumination on transmission efficiency for two apertures of equal size. Written in FORTRAN.

Pinero, L. R.↗

Antireflective Multi‐Dielectric Metasurfaces Operating in the Visible

Abstract As increasingly more demanding photonics applications are brought on‐chip, more complex design solutions are employed to deliver enhanced performance: e.g., meta‐molecules, inverse‐designed freeform structures, and multilayer metasurfaces. Instead, this study introduces anti‐reflective metasurfaces fabricated in a single nanolithography step that follows deposition of multiple dielectrics onto a substrate. Anti‐reflective metasurfaces offer fundamentally better transmission efficiencies compared to conventional equivalents. Conventional and anti‐reflective metalenses, both fabricated in the Ta 2 O 5 /SiO 2 material platform for 461 nm operation, show an improvement in focusing efficiencies from ≈ 55% to ≈ 90% at low numerical apertures and from ≈ 35% to ≈ 65% at high numerical apertures. Simulations of ideal and imperfect metalenses indicate that anti‐reflective metasurfaces not only improve transmission at the design library level, but also reduce spurious diffraction and protect against higher‐order scattering.

Optics↗

Rate 3/4 convolutional coding of 16-PSK - Code design and performance study

Convolutional coding coupled with 16-PSK modulation is investigated for bandwidth efficient transmission. Rate 3/4, small memory codes are found which are optimized in the free-distance sense on the Gaussian channel. These codes provide up to 4.8 dB of coding gain with 32 states over uncoded 8-PSK, a scheme having the same spectral efficiency as the codes described. The performance is compared with earlier findings of Ungerboeck and some recent results on R = 2/3 coded 8-PSK. In addition, results of a channel transmission study to assess the performance of the four-state code on the band-limited nonlinear channel are presented, and it is found that performance of the coded scheme degrades comparably with uncoded 8-PSK, i.e., coding gain is roughly preserved.

Wilson, S. G.↗

Electromagnetic reflection and transmission at interfaces involving graded dielectrics with applications to planetary radar astronomy

Reflection and transmission of electromagnetic waves at an interface between two homogeneous materials is modified when a transition zone of linearly increasing permittivity is inserted between the half spaces. Mathematical expressions for reflection and transmission coefficients are derived for waves at arbitrary incidence angles and polarized either in or perpendicular to the plane of incidence. Discontinuities in permittivity at the transition-zone boundaries are allowed. There is efficient transmission between the two half-spaces for transition-zone thicknesses of a wavelength or greater. For sharper changes, the matching layer has diminishing effect and the wave-interface interaction is characterized by the difference in properties between the two half-spaces. Examples applicable to lunar radar astronomy and airborne terrestrial remote sensing are used to illustrate the relationship between wavelength and thickness of the transition layer.

Simpson, R. A.↗

Wavelet Compression of Satellite-Transmitted Digital Mammograms

Breast cancer is one of the major causes of cancer death in women in the United States. The most effective way to treat breast cancer is to detect it at an early stage by screening patients periodically. Conventional film-screening mammography uses X-ray films which are effective in detecting early abnormalities of the breast. Direct digital mammography has the potential to improve the image quality and to take advantages of convenient storage, efficient transmission, and powerful computer-aided diagnosis, etc. One effective alternative to direct digital imaging is secondary digitization of X-ray films. This technique may not provide as high an image quality as the direct digital approach, but definitely have other advantages inherent to digital images. One of them is the usage of satellite-transmission technique for transferring digital mammograms between a remote image-acquisition site and a central image-reading site. This technique can benefit a large population of women who reside in remote areas where major screening and diagnosing facilities are not available. The NASA-Lewis Research Center (LeRC), in collaboration with the Cleveland Clinic Foundation (CCF), has begun a pilot study to investigate the application of the Advanced Communications Technology Satellite (ACTS) network to telemammography. The bandwidth of the T1 transmission is limited (1.544 Mbps) while the size of a mammographic image is huge. It takes a long time to transmit a single mammogram. For example, a mammogram of 4k by 4k pixels with 16 bits per pixel needs more than 4 minutes to transmit. Four images for a typical screening exam would take more than 16 minutes. This is too long a time period for a convenient screening. Consequently, compression is necessary for making satellite-transmission of mammographic images practically possible. The Wavelet Research Group of the Department of Electrical Engineering at The Ohio State University (OSU) participated in the LeRC-CCF collaboration by providing advanced compression technology using wavelet transform. OSU developed a time-efficient software package with various wavelets to compress a serious of mammographic images. This documents reports the result of the compression activities.

Zheng, Yuan F.↗

Rate 3/4 16-PSK phase codes

An investigation is carried out of convolutional-coding coupled with 16-PSK modulation for bandwidth efficient transmission. Small memory codes (rate three-fourths) are found that are optimum in the free-distance sense on the Gaussian channel. These codes furnish up to 4.8 dB of coding gain with 32 states over uncoded 8-PSK, a scheme having the same spectral efficiency as the codes described. The performance is compared with the earlier findings of Ungerboeck (1976, 1982) and certain recent results on R = 2/3 coded 8-PSK. It is shown that with 4 decoder states the coding gain is 3.5 dB and with 32 states it is 4.8 dB. What is more, the codes compare favorably with coded 16-QASK when envelope variations and peak energy constraints are considered.

Wilson, S. G.↗

Space-borne power conversion into a microwave beam and its impact on the environment of the upper atmosphere

The possible effect of microwave beams transmitted from Solar Power Satellites on the ionosphere has been studied theoretically. Particular attention is given to microwave-beam-heating of the F and D layers and theoretical predictions of such ionospheric modifications are used to determine resulting effects on the transmission efficiency of communication and navigation systems. It is recommended that a three-pronged technology and demonstration program be established to study microwave effects. The program would include theoretical studies, ground-based heating experiments, and an orbital experimental program for phase control of the microwave power transmission system.

Maynard, O. E.↗

Sol-Gel Glass Holographic Light-Shaping Diffusers

Holographic glass light-shaping diffusers (GLSDs) are optical components for use in special-purpose illumination systems (see figure). When properly positioned with respect to lamps and areas to be illuminated, holographic GLSDs efficiently channel light from the lamps onto specified areas with specified distributions of illumination for example, uniform or nearly uniform irradiance can be concentrated with intensity confined to a peak a few degrees wide about normal incidence, over a circular or elliptical area. Holographic light diffusers were developed during the 1990s. The development of the present holographic GLSDs extends the prior development to incorporate sol-gel optical glass. To fabricate a holographic GLSD, one records a hologram on a sol-gel silica film formulated specially for this purpose. The hologram is a quasi-random, micro-sculpted pattern of smoothly varying changes in the index of refraction of the glass. The structures in this pattern act as an array of numerous miniature lenses that refract light passing through the GLSD, such that the transmitted light beam exhibits a precisely tailored energy distribution. In comparison with other light diffusers, holographic GLSDs function with remarkably high efficiency: they typically transmit 90 percent or more of the incident lamp light onto the designated areas. In addition, they can withstand temperatures in excess of 1,000 C. These characteristics make holographic GLSDs attractive for use in diverse lighting applications that involve high temperatures and/or requirements for high transmission efficiency for ultraviolet, visible, and near-infrared light. Examples include projectors, automobile headlights, aircraft landing lights, high-power laser illuminators, and industrial and scientific illuminators.

Yu, Kevin↗

Performance of pumped counterflow virtual impactors to study aerosol interactions with laboratory generated warm clouds

Pumped Counterflow Virtual Impactors (PCVI) are designed to separate aerosols based on aerodynamic diameter, which is particularly useful for isolating cloud droplets and ice crystals from smaller particles. However, the PCVI transmission efficiency (TE) values reported in the literature show considerable variability, and little information is available on the TEs for cloud liquid droplets. Here, we determined the optimal flow conditions for PCVI sampling for different activation ratios from the MTU Pi-cloud chamber, highlighting the conditions that maximize droplet residual sampling while minimizing interstitial transmission. Even for a lower limit cloud activation ratio = 1:10, an add flow of 1.5 LPM achieves a residual fraction greater than 0.80, with a droplet TE of ∼15% for typical Pi-Chamber droplets with diameters between 3.5 to 10 µm. This framework can be adapted for field cloud measurements based on the cloud conditions of interest. TE for cloud droplets under flow conditions at which ∼99% of the unactivated submicron particles were removed was substantially lower between 8 and 16% than for supermicron dry particles (∼30 to 40% for 3 µm polystyrene latex spheres). In addition, we conducted a comparison of the performances of three similar PCVI units to assess repeatability for dry aerosols and cloud droplets. All three PCVIs performed similarly in rejecting submicron particles smaller than the desired cutoff diameter. One of the units showed lower TEs due to a misalignment of the internal orifice. We discuss a procedure that improved alignment and performance.

54 ENVIRONMENTAL SCIENCES↗

Drug Resistance in Filarial Parasites Does Not Affect Mosquito Vectorial Capacity

Parasite drug resistance presents a major obstacle to controlling and eliminating vector-borne diseases affecting humans and animals. While vector-borne disease dynamics are affected by factors related to parasite, vertebrate host and vector, research on drug resistance in filarial parasites has primarily focused on the parasite and vertebrate host, rather than the mosquito. However, we expect that the physiological costs associated with drug resistance would reduce the fitness of drug-resistant vs. drug-susceptible parasites in the mosquito wherein parasites are not exposed to drugs. Here we test this hypothesis using four isolates of the dog heartworm (Dirofilaria immitis)—two drug susceptible and two drug resistant—and two vectors—the yellow fever mosquito (Aedes aegypti) and the Asian tiger mosquito (Ae. albopictus)—as our model system. Our data indicated that while vector species had a significant effect on vectorial capacity, there was no significant difference in the vectorial capacity of mosquitoes infected with drug-resistant vs. drug-susceptible parasites. Consequently, contrary to expectations, our data indicate that drug resistance in D. immitis does not appear to reduce the transmission efficiency of these parasites, and thus the spread of drug-resistant parasites in the vertebrate population is unlikely to be mitigated by reduced fitness in the mosquito vector.

59 BASIC BIOLOGICAL SCIENCES↗

Increased Efficiency LED

In a semiconductor light emitting diode (LED) a large proportion of the light produced will be internally reflected when it strikes the end face of the LED at a semiconductor-air interface. This is due to the high index of refraction of most LED semiconductor materials. This problem may be partially overcome by modification of the shape of the LED by a reverse taper of the sides of the LED. Light is redirected by the taper to strike the interface at an angle closer to normal. This allows light to exit the LED that would be totally internally reflected in an untapered LED. The novelty of the present invention lies in the tapering of the sides of the LED for increased through transmission of light. Prior art devices have made use surface modifications such as roughening, addition of guiding layers, use of index matching materials and hemispherical shaping of the emitting end of the LED. Current technology LEDs have a transmission efficiency of only a few percent. An increase in this efficiency would be of great value to any technology that makes use of LEDs for light generation. The present invention is related to LAR 1 5050-SB, Collection of Light from Optical Fibers of NA greater than 1.

Egalon, Claudio Oliviera↗

Microwave Sterilization and Depyrogenation System

A fully functional, microgravity-compatible microwave sterilization and depyrogenation system (MSDS) prototype was developed that is capable of producing medical-grade water (MGW) without expendable supplies, using NASA potable water that currently is available aboard the International Space Station (ISS) and will be available for Lunar and planetary missions in the future. The microwave- based, continuous MSDS efficiently couples microwaves to a single-phase, pressurized, flowing water stream that is rapidly heated above 150 C. Under these conditions, water is rapidly sterilized. Endotoxins, significant biological toxins that originate from the cell walls of gram-negative bacteria and which represent another defining MGW requirement, are also deactivated (i.e., depyrogenated) albeit more slowly, with such deactivation representing a more difficult challenge than sterilization. Several innovations culminated in the successful MSDS prototype design. The most significant is the antenna-directed microwave heating of a water stream flowing through a microwave sterilization chamber (MSC). Novel antenna designs were developed to increase microwave transmission efficiency. These improvements resulted in greater than 95-percent absorption of incident microwaves. In addition, incorporation of recuperative heat exchangers (RHxs) in the design reduced the microwave power required to heat a water stream flowing at 15 mL/min to 170 C to only 50 W. Further improvements in energy efficiency involved the employment of a second antenna to redirect reflected microwaves back into the MSC, eliminating the need for a water load and simplifying MSDS design. A quick connect (QC) is another innovation that can be sterilized and depyrogenated at temperature, and then cooled using a unique flow design, allowing collection of MGW at atmospheric pressure and 80 C. The final innovation was the use of in-line mixers incorporated in the flow path to disrupt laminar flow and increase contact time at a given flow rate. These technologies can be employed in small-scale systems for efficient production of MGW in the laboratory or in a range of larger systems that meet various industrial requirements. The microwave antennas can also be adapted to selectively sterilize vulnerable connections to ultra-pure water production facilities or biologically vulnerable systems where microorganisms may intrude.

Akse, James R.↗

DGFRS-2—A gas-filled recoil separator for the Dubna Super Heavy Element Factory

The main goal of development of the new Dubna Gas-Filled Recoil Separator (DGFRS-2) is to sufficiently improve the efficiency of studies on heavy and superheavy nuclei at the Super Heavy Element Factory of the Flerov Laboratory of Nuclear Reactions (FLNR) at the Joint Institute for Nuclear Research. The use of beams with the intensity up to 6×10 13 s -1 (10 pμA) delivered by the DC280 cyclotron requires an effective setup providing high suppression of background reaction products. Additionally, the described gas-filled separator is optimized for synthesis and study of heavy isotopes produced in complete fusion reactions of massive nuclei. Basic characteristics of DGFRS-2, as well as the results of the first test experiments, are presented. In comparison to the DGFRS-1, the transmission efficiency was doubled, and the background was reduced by a factor 200.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solar Power Satellite (SPS) pilot beam and communication link subsystem investigation study, phase 1

A preliminary engineering model of ionospheric interactions with the pilot beam was established and used to demonstrate that the dual frequency baseline pilot beam system might not be viable in the presence of an unstable transmission path. Alternate approaches to remove this difficulty are described. Although ionospheric fluctuations will not significantly degrade beam pointing or raise the sidelobe levels, they will reduce transmission efficiency by upwards of 25%. Mitigating strategies to substantially reduce this effect are proposed. Based on the Klystron noise spectrum, the pilot beam transmitter power was determined as a function of frequency offset from the power beam carrier frequency. The RFI from the pilot beam, on the ground and at geosynchronous orbit is shown. Noise levels on the earth's surface due to the SPS are presented as a function of frequency and the number of SPS systems. Analysis of the communication subsystem indicates that a standard telemetry line of 1.544 MB/s would satisfy both voice and data link requirements. Additional links would be required for TV and radio transmissions.

Source record↗

Information-Theoretic Assessment of Sample Imaging Systems

By rigorously extending modern communication theory to the assessment of sampled imaging systems, we develop the formulations that are required to optimize the performance of these systems within the critical constraints of image gathering, data transmission, and image display. The goal of this optimization is to produce images with the best possible visual quality for the wide range of statistical properties of the radiance field of natural scenes that one normally encounters. Extensive computational results are presented to assess the performance of sampled imaging systems in terms of information rate, theoretical minimum data rate, and fidelity. Comparisons of this assessment with perceptual and measurable performance demonstrate that (1) the information rate that a sampled imaging system conveys from the captured radiance field to the observer is closely correlated with the fidelity, sharpness and clarity with which the observed images can be restored and (2) the associated theoretical minimum data rate is closely correlated with the lowest data rate with which the acquired signal can be encoded for efficient transmission.

Huck, Friedrich O.↗