Search NASA⌕ Search

SEARCH · Search NASA

Results for “TRANSPIRATION COOLING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Design of Transpiration Cooled Thermal Protection Systems

This study explored three approaches for the utilization of transpiration cooling in thermal protection systems. One model uses an impermeable wall with boiling water heat transfer at the backface (Model I). A second model uses a permeable wall with a boiling water backface and additional heat transfer to the water vapor as it flows in channels toward the exposed surface (Model II). The third model also uses a permeable wall, but maintains a boiling condition at the exposed surface of the material (Model III). The governing equations for the models were developed in non-dimensional form and a comprehensive parametric investigation of the effects of the independent variables on the important dependent variables was performed. In addition, detailed analyses were performed for selected materials to evaluate the practical limitations of the results of the parametric study.

Callens, E. Eugene, Jr.↗

Flow through a wire-form transpiration-cooled vane

Results of recent research to develop techniques for analyzing coolant flow in transpiration-cooled vanes are summarized. Flow characteristics of the wire-form porous material are correlated; the effects on the flow characteristics of oxidation, coolant temperature, gas crossflow, and airfoil curvature are evaluated. An analytical method is presented for predicting coolant flows and pressures in a strut-supported vane.

Kaufman, A. S.↗

Exploratory Engine Test of Transpiration-cooled Turbine-rotor Blade with Wire-cloth Shell

Engine tests were made on a transpiration-cooled blade that was fabricated from an internal load-carrying member with an external surface of wire cloth. After operation in the engine, some damage was noted at the tip region of the trailing edge of the blades. On other sections of the blade, the wire cloth did not appear greatly overheated, and it appeared that satisfactory chordwise temperature distribution was provided by orifices in the blade base.

ENGINES, COOLING↗

A simplified analytical solution for thermal response of a one-dimensional, steady state transpiration cooling system in radiative and convective environment

A simplified analytical method for calculation of thermal response within a transpiration-cooled porous heat shield material in an intense radiative-convective heating environment is presented. The essential assumptions of the radiative and convective transfer processes in the heat shield matrix are the two-temperature approximation and the specified radiative-convective heatings of the front surface. Sample calculations for porous silica with CO2 injection are presented for some typical parameters of mass injection rate, porosity, and material thickness. The effect of these parameters on the cooling system is discussed.

Kubota, H.↗

Transpiration Cooling Of Hypersonic Blunt Body

Results on analytical approximation and numerical simulation compared. Report presents theoretical study of degree to which transpiration blocks heating of blunt, axisymmetric body by use of injected air. Transpiration cooling proposed to reduce operating temperatures on nose cones of proposed hypersonic aerospace vehicles. Analyses important in design of thermal protection for such vehicles.

Henline, William D.↗

Measurement and Empirical Correlation of Transpiration-Cooling Parameters on a 25 degree Cone in a Turbulent Boundary Layer in Both Free Flight and a Hot-Gas Jet

Transpiration-cooling parameters are presented for a turbulent boundary layer on a cone configuration with a total angle of 250 which was tested in both free flight and in an ethylene-heated high-temperature jet at a Mach number of 2.0. The flight-tested cone was flown to a maximum Mach number of 4.08 and the jet tests were conducted at stagnation temperatures ranging from 937 R to 1,850 R. In general, the experimental heat transfer was in good agreement with the theoretical values. Inclusion of the ratio of local stream temperature to wall temperature in the nondimensional flow rate parameter enabled good correlation of both sets of transpiration data. The measured pressure at the forward station coincided with the theoretical pressure over a sharp cone; however, the measured pressure increased with distance from the nose tip.

Walton, Thomas E., Jr.↗

Calculations of Laminar Heat Transfer Around Cylinders of Arbitrary Cross Section and Transpiration-Cooled Walls with Application to Turbine Blade Cooling

An approximate method for development of flow and thermal boundary layers in laminar regime on cylinders with arbitrary cross section and transpiration-cooled walls is obtained by use of Karman's integrated momentum equation and an analogous heat-flow equation. Incompressible flow with constant property values throughout boundary layer is assumed. Shape parameters for approximated velocity and temperature profiles and functions necessary for solution of boundary-layer equations are presented as charts, reducing calculations to a minimum. The method is applied to determine local heat-transfer coefficients and surface temperature-cooled turbine blades for a given flow rate. Coolant flow distributions necessary for maintaining uniform blade temperatures are also determined.

TURBINE COOLING↗

Transpiration cooling in the locality of a transverse fuel jet for supersonic combustors

The objective of the current work was to determine the feasibility of transpiration cooling for the relief of the local heating rates in the region of a sonic, perpendicular, fuel jet of gaseous hydrogen. Experiments were conducted to determine the interaction between the cooling required and flameholding limits of a transverse jet in a high-enthalpy, Mach 3 flow in both open-jet and direct-connect test mode. Pulsed shadowgraphs were used to illustrate the flow field. Infrared thermal images indicated the surface temperatures, and the OH(-) emission of the flame was used to visualize the limits of combustion. Wall, static presures indicated the location of the combustion within the duct and were used to calculate the combustion efficiency. The results from both series of tests at facility total temperatures of 1700 K and 2000 K are presented.

Northam, G. Burton↗

Wire Cloth as Porous Material for Transpiration-cooled Walls

The permeability characteristics and tensile strength of a porous material developed from stainless-steel corduroy wire cloth for use in transpiration-cooled walls where the primary stresses are in one direction were investigated. The results of this investigation are presented and compared with similar results obtained with porous sintered metal compacts. A much wider range of permeabilities is obtainable with the wire cloth than with the porous metal compacts considered and the ultimate tensile strength in the direction of the primary stresses for porous materials produced from three mesh sizes of wire cloth are from two to three times the ultimate tensile strengths of the porous metal compacts.

MATERIALS - TYPES↗

Evaluation of Transpiration-Cooled Turbine Blades with Shells of "Poroloy" Wire Cloth

An experimental investigation was made to evaluate the durability and permeability of a group of transpiration-cooled, strut-supported turbine blades. The porous shells were formed from a woven-wire material. The blades were fabricated by a contractor for the Bureau of Aeronautics. The results of permeability tests indicated that the shell material exhibited large random variations in local permeability, which result in excessive coolant flows and very nonuniform cooling. For this reason no heat-transfer evaluations were made because any results would have been inconclusive. Four blades were investigated for structural soundness in a turbo-jet engine operating at a turbine-inlet temperature of approximately 1670 deg F and a turbine tip speed of approximately 1305 feet per second. The maximum temperature of the porous-shell material was approximately 1050 deg F. Inspection of the first two blades after 10 minutes of engine operation revealed that the tips of both of the blades had failed. For the second pair of blades, an improved tip cap was provided by the use of built-up weld extending from strut tip to shell. One of these blades was then operated for 33 hours without failure, and was found to be in good condition at the end of this time. The second blade of this second pair failed within the first 10 minutes of operation because of a poor bond between shell and strut lands.

Richards, Hadley T.↗

Thermal/structural analysis of a transpiration cooled nozzle

The 8-foot High Temperature Tunnel (HTT) at LaRC is a combustion driven, high enthalpy blow down wind tunnel. In Mar. 1991, during check out of the transpiration cooled nozzle, pieces of platelets were found in the tunnel test section. It was determined that incorrect tolerancing between the platelets and the housing was the primary cause of the platelet failure. An analysis was performed to determine the tolerance layout between the platelets and the housing to meet the structural and performance criteria under a range of thermal, pressure, and bolt preload conditions. Three recommendations resulted as a product of this analysis.

Gregory, Peyton B.↗

Exploratory Investigation of Transpiration Cooling of a 40 Degree Double Wedge Using Nitrogen and Helium as Coolants at Stagnation Temperatures from 1,295 Degrees Fahrenheit to 2,910 Degrees Fahrenheit

An investigation of transpiration cooling has been conducted in the preflight jet of the Langley Pilotless Aircraft Research Station at Wallops Island, Va. The model consisted of a double wedge of 40 deg included angle having a porous stainless-steel specimen inserted flush with the top surface of the wedge. The tests were conducted at a free-stream Mach number of 2.0 for stagnation temperatures ranging from 1,295 F to 2,910 F. Nitrogen and helium were used as coolants and tests were conducted for values ranging from approximately 0.03 to 0.30 percent of the local weight flow rate. The data for both the nitrogen and helium coolants indicated greater cooling effectiveness than that predicted by theory and were in good agreement with the results for an 8 deg cone tested at a stagnation temperature of 600 F. The results indicate that the helium coolant, for the same amount of heat-transfer reduction, requires only about one-fourth to one-fifth the coolant flow weight as the nitrogen coolant.

Rashis, Bernard↗