Search NASA⌕ Search

SEARCH · Search NASA

Results for “TUNGSTATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Origin of tungsten and geochemical controls on its occurrence and mobilization in shallow sediments from Fallon, Nevada, USA

In this study, tungsten (W) occurrence and speciation was investigated in sediments collected from Fallon, Nevada where previous studies have linked elevated W levels in human body fluids to an unusual cluster of childhood leukemia cases. The speciation of sedimentary W was determined by μ-XRF mapping and μ-XANES. The W content of the analyzed surface sediments ranged between 81 and 25,908 mg/kg, which is significantly higher than the W content in deeper sediments which ranged from 37 to 373 mg/kg at 30 cm depth. The μ-XANES findings reveal that approximately 20–50% of the total W in the shallow sediment occurs in the metallic form (W 0 ); the rest occurs in the oxide form (W VI O 3 ). Because W 0 does not occur naturally, its elevated concentrations in surface sediments point toward a possible local anthropogenic origin. The oxidation of metallic W 0 with meteoric waters likely leads to the formation of W VI O 3 . The chief water-soluble W species was identified as WO 4 2– by chromatographic separation and speciation modeling. These results led us to postulate that W 0 particles from a currently unknown but local source(s) is (are) deposited onto the soils and/or surface sediments. The W 0 in interaction with meteoric water is oxidized to W VI O 3 , and as these sediment-water interactions progress, WO 4 2– is formed in the water at pH ~7. Under pH < 7, and sufficient W concentrations, tungstate tends to polymerize, and polymerized species are less likely to adsorb onto sediments. Polymerized species have lower affinity than monomers, which leads to enhanced mobility of W.

58 GEOSCIENCES↗

Radiation hardness characterization of LKH-5 scintillating glass

Radiation hardness is an important property to examine in scintillators to help determine their expected lifetime in application cases where significant radiation dose is expected. Industrial imaging systems using 9 MV linear accelerators for x-ray radiography are one such application where significant radiation doses are expected to the scintillators used. Cadmium tungstate scintillators (CWO) and Thallium doped Cesium Iodide scintillators (CsI(Tl)) are used in some high energy cargo x-ray radiography systems. However, CWO has a high manufacturing cost for adequately uniform crystals and CsI(Tl) does not have sufficient radiation hardness. LKH-5 glass is being investigated as a potential low cost replacement for CWO and CsI(Tl). In this experiment 36 samples of a terbium doped silicate glass called LKH-5 were irradiated at doses up to 5 MRad using a 9 MV linear accelerator, and the change in their transmission properties was observed. Additionally, the glass was discovered to be a radiation hard glass due to the relatively small change in the transmission of the glass: less than 3% per cm at its emission peak of 550 nm and 5 MRad. This is similar to CWO which has a reported reduction in transmitted light of 2% per cm at 5 MRad and the emission peak of 475 nm and better than CsI(Tl) which is reported to have a reduction in transmitted light of 5% per cm at the emission peak of 550 nm and 4.2 MRad dose. Furthermore, an annealing procedure is described that returned the transmission of the glass to pre-irradiation values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance of $\text{BDX-MINI}$ veto systems

Here this paper describes the veto system of the BDX-MINI detector installed at Jefferson Lab (US). The BDX-MINI experiment is the first electron beam-dump experiment specifically designed to search for Light Dark Matter (LDM) particles in the MeV-GeV mass range. The core of the BDX-MINI detector is a lead-tungstate electromagnetic calorimeter, for a total volume of 4 dm 3 . The calorimeter is surrounded by a multi-layer veto aimed at rejecting cosmic background: the innermost layer of the veto is made by a passive tungsten shielding for low energy radiation, while plastic scintillators make the middle and outer layers for charged cosmic particles rejection. Being located about 20 m downstream, the dirt between the beam dump and the detector provides sufficient shielding from the beam-related background. In 2019–2020, BDX-MINI was exposed for about six months to weakly interacting particles (neutrinos and, if existing, DM) produced by a 2.176 GeV electron beam incident on the beam dump of experimental Hall-A at Jefferson Lab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling athermal phonons in novel materials using the G4CMP simulation toolkit

Understanding phonon and charge propagation in superconducting devices plays an important role in both performing low-threshold dark matter searches and limiting correlated errors in superconducting qubits. The Geant4 Condensed Matter Physics (G4CMP) package, originally developed for the Cryogenic Dark Matter Search (CDMS) experiment, models charge and phonon transport within silicon and germanium detectors and has been validated by experimental measurements of phonon caustics, mean charge-carrier drift velocities, and heat pulse propagation times. Here, in this work, we present a concise framework for expanding the capabilities for phonon transport to a number of other novel substrate materials of interest to the dark matter and quantum computing communities, including sapphire (Al 2 O 3 ), gallium arsenide (GaAs), lithium fluoride (LiF), calcium tungstate (CaWO 4 ), and calcium fluoride (CaF 2 ). We demonstrate the use of this framework in generating phonon transport properties of these materials and compare these properties with experimentally-determined values where available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation hard gallium oxide scintillators for high count rate radiation detection

Despite decades of materials research, the availability of appropriate crystalline radiation-hard scintillators with ultrafast decay times (~10ns) and high light yields (>2000 ph/MeV) are still limited. In this study, we demonstrate the potential of gallium oxide (β-Ga 2 O 3 ) based scintillators for high count rate applications. The low-cost rugged β-Ga 2 O 3 scintillators were grown using the optical float zone (FZ) technique. Several dopants and growth atmospheres were used to demonstrate the balance between ultrafast primary decay time and the light yield of the scintillators. Light yields as high as 6446 ± 716 ph/MeV were obtained with 18.3 ns decay time for 662 keV gamma rays. Decay times as fast as 12ns were obtained with a 3212 ± 357 ph/MeV light yield. An excellent 662 keV gamma energy resolution of 7% was obtained using the β-Ga 2 O 3 :Ce crystals. Even with these excellent scintillation properties, the gamma radiation hardness of β-Ga 2 O 3 crystals was better than the leading radiation-hard lead tungstate (PbWO 4 ) crystals. Twenty-six scintillators fabricated from the grown β-Ga 2 O 3 crystals were tested for radiation hardness with a 60 Co gamma irradiation rate of 14 krad/h with a total radiation dose of 2 Mrad. The scintillation properties of these crystals remained unaffected. To date, no other scintillator has demonstrated such high radiation resistance. Furthermore, these FZ-grown low-cost, non-hygroscopic, and high-density β-Ga 2 O 3 scintillators can replace the existing scintillators in many applications ranging from nuclear and high energy physics experiments to nuclear security.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Antioxidant-induced transformations of a metal-acid hydrocracking catalyst in the deconstruction of polyethylene waste

Plastics are ideal for numerous applications, as driven by the development of complex formulations containing various additives to improve performance and processability. Unfortunately, chemical valorization strategies (e.g., catalytic deconstruction) often can be challenged by the presence of small-molecule additives, and quantification of the impact of these molecular constituents on upcycling processes remains elusive. Here, this dearth of information restricts catalyst design efforts to combine the robustness and performance necessary to improve plastics circularity. In this communication, we describe a systematic study of common plastics additives—phenolic antioxidants, and we quantify the relationship between additive content and deconstruction yields of high-density polyethylene (HDPE) over a platinum on tungstated zirconium (Pt/WO 3 /ZrO 2 ) hydrocracking catalyst. In the simplest case of a base (antioxidant- and slip agent-containing) HDPE resin versus a pure (additive-stripped) HDPE polymer, a two-fold decrease in the yield of gas and liquid products is noted for base HDPE resin. Furthermore, both antioxidant chemistry and concentration strongly impact conversion and individual product selectivities. Using infrared spectroscopy, we determine that antioxidants change the effective ratio of metal to acid sites (i.e., metal-acid balance) through reactions of phenols and/or other functional groups (e.g., acids, esters) with catalyst active sites. Overall, this work demonstrates the impact of one common set of additives on plastics deconstruction, and the analysis herein provides a blueprint for quantitatively assessing the effects of additives on plastics deconstruction processes and for evaluating the development of more robust catalytic strategies or more tolerable additive formulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Heavy Photon Search (HPS) Software Environment

The Heavy Photon Search (HPS) is an experiment at the Thomas Jefferson National Accelerator Facility (JLab) designed to search for a hidden sector photon (A’) in fixed-target electro-production. It uses a silicon microstrip tracking and vertexing detector placed inside a dipole magnet to measure charged particle trajectories and a fast lead-tungstate crystal calorimeter located just downstream of the magnet to provide a trigger and to identify electromagnetic showers. The HPS experiment uses both invariant mass and secondary vertex signatures to search for the A’. The experimental collaboration is small and quite heterogeneous: it is composed of members of the nuclear physics as well as particle physics communities, from universities and national labs from around the US and Europe. Enabling such a disparate group to concentrate on the physics aspects of the experiment required that the software be easy to install and use, and having such limited manpower meant that existing solutions had to be exploited. HPS has successfully completed two engineering runs and completed its first physics run in the summer of 2019. We begin with an overview of the physics goals of the experiment followed by a short description of the detector design. We then describe the software tools used to design the detector layout and simulate the expected detector performance. Event reconstruction involving track, cluster and vertex finding and fitting for both simulated and real data was, to first order, adopted from existing software originally developed for Linear Collider studies. Bringing it all together into a cohesive whole involved the use of multiple software solutions with common interfaces.

Graf, Norman↗

Tungsten enzymes play a role in detoxifying food and antimicrobial aldehydes in the human gut microbiome

Significance The diverse microorganisms contained within the human gut are known to have significant effects on human health. Herein, we show that genes encoding members of the tungsten oxidoreductase (WOR) family of enzymes and a tungstate-specific transporter are prevalent in the human gut microbiome and metagenome. We demonstrate that two model gut microbes assimilate tungsten into multiple WOR enzymes and that some of these enzymes catalyze the conversion of gut aldehydes to the corresponding acid, likely as a detoxification strategy to remove these reactive compounds.

59 BASIC BIOLOGICAL SCIENCES↗

Reconstruction of signal amplitudes in the CMS electromagnetic calorimeter in the presence of overlapping proton-proton interactions

A template fitting technique for reconstructing the amplitude of signals produced by the lead tungstate crystals of the CMS electromagnetic calorimeter is described. This novel approach is designed to suppress the contribution to the signal of the increased number of out-of-time interactions per beam crossing following the reduction of the accelerator bunch spacing from 50 to 25 ns at the start of Run 2 of the LHC. Execution of the algorithm is sufficiently fast for it to be employed in the CMS high-level trigger. It is also used in the offline event reconstruction. Results obtained from simulations and from Run 2 collision data (2015–2018) demonstrate a substantial improvement in the energy resolution of the calorimeter over a range of energies extending from a few GeV to several tens of GeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The RAPTR furnace: a rapid heating and cooling sample furnace for in situ X-ray scattering studies of temperature-induced reactions

In situX-ray scattering provides valuable insights into the mechanisms and kinetics of reactions and structural transformations. For reactions and structural transformations primarily driven by temperature, and not coupled to chemical/electrochemical triggers, our ability to initiate and quench processes thermally is a practical limit for probing fast reactive phenomena. Meaningful quantitative analysis requires the dynamic phenomena to be triggered on fast time scales relative to the reaction/transformation kinetics. This article describes a new sample furnace, the Rapid-Actuating Pneumatic Thermal Reactor or RAPTR, for time-resolvedin situX-ray scattering studies initiated by temperature. The RAPTR quickly heats and cools samples by translating them into and out of a pre-heated hot zone. Using diffraction thermometry, it is shown that the samples can be heated/cooled in 10 s or less, with temperatures up to ∼1000°C being accessible. The application of the RAPTR furnace is demonstrated by exploring a fast solid-state reaction: the synthesis of scheelite-type lead tungstate, PbWO 4 , from PbO and WO 3 for which Pb 3 WO 6 is identified as a previously unrecognized reaction intermediate.

Chemistry↗

The Jefferson Lab Eta Factory (JEF) experiment

The Jefferson Lab Eta Factory (JEF) experiment is an upcoming experiment designed to run in Hall D at Jefferson Lab using an upgraded GlueX spectrometer to study various decays of the ? meson. The GlueX spectrometer consists of a ?2 Tesla solenoid magnet housing a liquid hydrogen target and drift chambers used for tracking charged particles and an array of lead glass blocks (the Forward Calorimeter (FCAL)) downstream of the magnet for detecting neutral particles. The decays of the ? meson can be used to measure the light quark mass ratio via the ???+???0 channel and allow access to higher-order terms in Chiral Perturbation Theory via the ???0?? channel. The decays can also be used to constrain new charge-conjugation violating/parity conserving (CVPC) reactions and to search for signatures of dark matter. In particular, the ???0?? channel can be used to search for lepto-phobic dark vector (B) bosons in the reaction ??B? (B??0?) or dark scalar (S) bosons in the reaction ???0S (S???). Studying the rare radiative decay channel ???0?? requires replacing the 4×4×45 cm3 lead glass blocks in the inner region of the FCAL with 2×2×20 cm3 lead tungstate crystals, which will provide twice better position and energy resolution. This talk will describe the JEF physics program and the upgrade to the FCAL.

Taylor, Simon↗

The JLab Eta Factory (JEF) experiment

The new experiment, JLab Eta Factory (JEF), in the experimental Hall D at Jefferson Lab will extend the physics potential of the GlueX detector beyond the main spectroscopy program and perform precision measurements of various ?(?)decays with emphasis on rare neutral modes. The physics program of the experiment spans from precision tests of low-energy QCD to search of gauge bosons in the mass range below 1 GeV coupling the SM sector to the dark sector. Photoproduction of highly boosted ?(?)mesons using a tagged photon beam, good detection of recoil proton and multi-photon final states will allow to suppress background and collect high-statistics data sample of ?mesons. All these provide many advantages over other ?(?)experiments. The JEF experiment requires to upgrade the inner part of the forward lead glass calorimeter of the GlueX detector with high-granularity, high-resolution lead tungstate PbWO4 scintillating crystals. The calorimeter insert is currently under construction at Jeffeson Lab. The detector will be ready to take data in 2024. An overview of the JEF project will be presented.

Somov, Alexander↗

JLab eta Factory Experiment in Hall D

The new experiment, JLab Eta Factory (JEF), in the experimental Hall-D at Jefferson Lab will extend the physics potential of the GlueX beyond the main spectroscopy program and study rare decays of eta mesons. Among various physics topics, the experiment will focus on decays of eta mesons to the eta -> pi0 gamma gamma final state. This decay mode provides an important information for higher-order calculations in chiral perturbation theory. The final state is ideal for the search of the leptophobic dark B-boson in the reactions eta -> B gamma, B -> pi0 gamma; and the scaler dark matter mediator S in the channel eta -> pi0 S, S -> gamma gamma. The experiment requires to upgrade the inner part of the forward lead glass calorimeter of the GlueX detector with high-granularity, high-resolution lead tungstate PbWO4 scintillating crystals. The detector will be ready to take data in 2023. I will give an overview of the JEF project.

Somov, Alexander↗

Tungsten Electrodeposition

Tungsten is a refractory metal with a very high melting point (3422 °C), hardness (7.5 on Mohs hardness scale), and chemical resistance, making it useful in applications with extreme conditions. Electrodeposition is an attractive technique for coating metals because of its scalability and applicability to objects of intricate shape, though tungsten electrodeposition remains difficult. Some multi-step methods first coat either a sacrificial metal such as zinc or a layer of tungsten oxide which is then converted to metallic tungsten with WCl6 immersion (i.e. a redox replacement reaction) or heating in a reducing atmosphere, respectively. Single step deposition would save time and money, making it more viable on an industrial scale. Most reports detailing direct tungsten electrodeposition use molten salts which are energy intensive, hazardous, and difficult to maintain. Few reports have demonstrated single-step, low temperature electrodeposition deposition of tungsten in atmosphere. An article from 1931 reports successful metal tungsten electrodeposition from a highly basic sodium tungstate solution, though the authors reported very low current efficiency (<1%) and required heating to 80+ °C to obtain metallic films. This report outlines our attempts to electroplate tungsten from various solutions on different electrode materials, none of which succeeded. Our intent is to guide future researchers at Los Alamos National Laboratory that would attempt tungsten electrodeposition.

36 MATERIALS SCIENCE↗

Simulating Superconducting Devices in Novel Materials Using the G4CMP Simulation Toolkit

Understanding the kinematics of phonons and charge propagation in superconducting devices is crucial for conducting low-threshold dark matter searches and minimizing correlated errors in superconducting qubits. For nearly a decade, the Geant4 Condensed Matter Physics (G4CMP) package, originally developed for the Cryogenic Dark Matter Search (CDMS) experiment, has been limited to simulating charge and phonon transport in silicon and germanium materials. In this work, we have expanded the capabilities of G4CMP to include novel substrate materials such as sapphire (Al2O3), Gallium Arsenide (GaAs), Lithium Fluoride (LiF), Calcium Tungstate (CaWO4), and Calcium Fluoride (CaF2). We demonstrate the use of this toolkit in generating phonon transport properties for these materials and compare the results with experimentally determined values where available. Additionally, we explore the performance of superconducting devices utilizing these materials.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Jefferson Lab Eta Factory Experiment and Applications of PbWO4 Calorimeters in Future Experimental Facilities

The goal of the new JLab Eta Factory (JEF) experiment, conducted with the GlueX detector in Hall D at Jefferson Lab, is to perform measurements of various ¿(') decays with a primary focus on rare neutral modes. The experiment’s physics program ranges from precision tests of low-energy QCD to searches for gauge bosons with masses below 1 GeV that could couple the Standard Model (SM) sector to the dark sector. The experiment will collect a high-statistics data sample of ¿(') mesons produced via a beam of tagged photons. The GlueX detector features a large, nearly uniform acceptance for both neutral and charged particles, enabling efficient identification of complex multi-particle final states. To meet the requirements of the JEF experiment, the inner section of the forward lead-glass calorimeter in the GlueX detector has been upgraded with lead tungstate (PbWO4) scintillating crystals. PbWO4 offers exceptional characteristics, such as a small radiation length and Molire radius, and large light yield, that make it ideal for constructing high- granularity, high-resolution, radiation-hard detectors. These properties enable excellent spatial separation and energy resolution of reconstructed electromagnetic showers, establishing PbWO4 as the material of choice for many high-precision experiments. The JEF experiment began data collection in April 2025 and will operate concurrently with the GlueX experiment, whose primary objective is the search for gluonic excitations in the meson spectrum. I will give an overview of the JEF experiment, the GlueX detector, and the feasibility of further upgrades to support future ¿ physics studies. Special attention will be given to the newly constructed PbWO4 scintillating calorimeter and recent advancements in calorimeter instrumentation.

Somov, Alexander↗

Status of the Jefferson Lab Eta Factory (JEF) experiment

The Jefferson Lab Eta Factory (JEF) experiment is an experiment running in Hall D at Jefferson Lab that focuses on studying the decays of the ¿ meson. These decays provide a rich laboratory for searching for new charge conjugation violating / parity conserving (CVPC) processes, looking for hints of Beyond Standard Model physics, and probing higher order terms in Chiral Perturbation Theory. The flagship channel is the rare decay ¿ ¿ p0¿¿, the measurement of which required an upgrade to the existing equipment in Hall D. The experiment uses the GlueX detector, a fixed-target large acceptance spectrometer based on a solenoid magnet containing drift chambers for tracking charged particles and a lead-scintillator barrel calorimeter in the central region and an array of 4 × 4 × 45 cm3 lead glass blocks in the forward region for detecting neutral particles. During the last two years the inner 80×80 cm2 region of the forward calorimeter has been replaced by an array of 2 × 2 × 20 cm3 lead tungstate crystals, which provide factors of two improvement in energy and position resolution. The first round of data taking with this configuration took place this year. A first look at the data will be presented.

Taylor, Simon [Thomas Jefferson National Accelerat↗

A new active base of photomultiplier R4125 designed for the PbWO4 calorimeter

This paper presents the design, performance, and results of the radiation tests of an active base for Hamamatsu R4125 photomultiplier tube. The active base was designed at Jefferson Lab and comprises of a high voltage divider and an on-board amplifier. The photomultiplier with the active base is used to detect light from lead tungstate scintillating crystals of the forward electromagnetic calorimeter of the GlueX detector. The active base amplifier allows to operate the tube at lower high voltage and thus to limit the photomultiplier anode current to a few micro ampereres at the maximum counter rate of 1 MHz counter, while retaining the dynamic range of output signals. The performance of calorimeter modules instrumented with the active base was studied using detector prototypes positioned into the beam of photons. The key performance parameters such as the linearity, high-rate capability, and the energy resolution verified that the active base design meets the detector specifications

Somov, Alexander [Thomas Jefferson National Accele↗