Search NASA⌕ Search

SEARCH · Search NASA

Results for “TURBINES - BLADES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Wind plant wake losses: Disconnect between turbine actuation and control of plant wakes with engineering wake models

Wake losses from neighboring plants may become a major factor in wind plant design and control as additional plants are constructed in areas with high wind resource availability. Because plant wakes span a large range of physical scales, from turbine rotor diameter to tens of kilometers, it is unclear whether conventional wake models or turbine control strategies are effective at the plant scale. Wake steering and axial induction control are evaluated in the current work as means of reducing the impact of neighboring wind plants on power and levelized cost of electricity. FLOw Redirection and Induction in Steady State (FLORIS) simulations were performed with the Gauss–Curl Hybrid and TurbOPark wake models as well as two operation and maintenance models to investigate control setpoint sensitivity to wake representation and economic factors. Both wake models estimate losses across a range of atmospheric conditions, although the wake loss magnitude is dependent on the wake model. Annual energy production and levelized cost of electricity are driven by wind direction frequency, with frequently aligned plants experiencing the greatest losses. However, both wake steering and axial induction are unable to mitigate the impact of upstream plants. Wake steering is constrained by plant geometry, since wake displacement is much less than the plant wake width, while axial induction requires curtailing the majority of turbines in upstream plants. Individual turbine strategies are limited by their effective scale and model representation. New wake models that include plant-scale physics are needed to facilitate the design of effective plant wake control strategies.

Scott, Ryan (ORCID:0000000328107574)↗

Cold-air performance of the compressor-drive turbine of the Department of Energy baseline automobile gas-turbine engine

The aerodynamic performance of the compressor-drive turbine of the DOE baseline gas-turbine engine was determined over a range of pressure ratios and speeds. In addition, static pressures were measured in the diffusing transition duct located immediately downstream of the turbine. Results are presented in terms of mass flow, torque, specific work, and efficiency for the turbine and in terms of pressure recovery and effectiveness for the transition duct.

Roelke, R. J.↗

Turbine Vane External Heat Transfer. Volume 2. Numerical Solutions of the Navier-stokes Equations for Two- and Three-dimensional Turbine Cascades with Heat Transfer

The application of the time-dependent ensemble-averaged Navier-Stokes equations to transonic turbine cascade flow fields was examined. In particular, efforts focused on an assessment of the procedure in conjunction with a suitable turbulence model to calculate steady turbine flow fields using an O-type coordinate system. Three cascade configurations were considered. Comparisons were made between the predicted and measured surface pressures and heat transfer distributions wherever available. In general, the pressure predictions were in good agreement with the data. Heat transfer calculations also showed good agreement when an empirical transition model was used. However, further work in the development of laminar-turbulent transitional models is indicated. The calculations showed most of the known features associated with turbine cascade flow fields. These results indicate the ability of the Navier-Stokes analysis to predict, in reasonable amounts of computation time, the surface pressure distribution, heat transfer rates, and viscous flow development for turbine cascades operating at realistic conditions.

Yang, R. J.↗

Considerations for testing full-scale wind turbine nacelles with hardware-in-the-loop

In this paper, pole placement control techniques are utilized to compensate for variations in the torsional dynamics resulting from the different boundary conditions experienced by a wind turbine nacelle when mounted on a test bench. Simulation case studies are used to understand the baseline torsional characteristics of the nacelle coupled to the test bench versus that coupled to the rotor. It was found that the frequency shifts by up to 200% and 400% for the first and second torsional modes, respectively. The feasibility of utilizing pole placement technique to match the torsional characteristics of the turbine on the test bench is investigated using PI and PID controllers. Here, the performance of the tuned controller is then verified under two test scenarios: Low Voltage Ride Through (LVRT), and a highly dynamic turbulent wind input. It is demonstrated that tuning the test bench speed controller can effectively shift the poles of the closed-loop system to match the desired first and second modes of the full turbine and replicate transient field events on the test bench.

17 WIND ENERGY↗

Critical design load case fatigue and ultimate failure simulation for a 10-m H-type vertical-axis wind turbine

While previous studies investigating critical VAWT design load cases have focused on large and relatively flexible Darrieus designs, the bulk of current commercial products seeking certification fall in the relatively small, stiff, and H-type configuration, such as the XFlow Energy Corporation turbine that this study compares against. Understanding the critical design load case impacts for both fatigue and ultimate failure for this size and type of VAWT are imperative for certification. The abil

Brownstein, Ian↗

Bulb-style Kaplan Turbine - Run-of-the-river (ror) Hydro Governor And Turbine Model

This software package includes hydro governor and turbine models developed in Simulink (Mathworks Inc.) and RSCAD (RTDS Technologies) for low-head bulb-style Kaplan turbine hydropower plants. The model developed in Simulink has been designed and tuned to match the governor-turbine response for a real-world hydropower unit owned by Idaho Falls Power (IFP). The Simulink and RSCAD models enable real-time testing in a hardware-in-the-loop (HIL) implementation using OPAL-RT and RTDS digital real-time simulators, respectively. An automatic initialization for dynamic simulation has also been integrated to each model in both Simulink and RSCAD. The RSCAD initialization involves a novel python-based interfacing for automatic modification of the initial conditions in the model. The parameters of these models can be tuned to match other hydropower plants in this class.

Alam, SMShafiul↗

Computational Design to Advance AM Fabrication of High Gamma Prime Alloys for Hot Gas Path Components in Gas Turbine Engines: A Pathway to Enhanced Gas Turbine Efficiency and Energy Saving (Final CRADA Report)

Raising turbine inlet temperature is a key lever for improving industrial gas-turbine efficiency and power output, but it increases thermo-mechanical demands on hot-gas-path components. Additive manufacturing (AM), particularly laser powder bed fusion (L-PBF), enables complex internal cooling features in critical components such as turbine tip shoes that are difficult to produce by conventional casting. However, qualification of new high-temperature AM alloys and aggressive geometries is often limited by trial-and-error iteration of build parameters and post-build heat treatments, with cracking during stress relieving or hot isostatic pressing (HIP) being a recurring failure mode.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cold-air investigation of a 3 1/2-stage fan-drive turbine with a stage loading factor of 4 designed for an integral lift engine. 1: Turbine design and performance of first stage

The design of the 3 1/2-stage turbine is described, and the cold-air performance of the first stage, modified for axial inlet conditions, is presented. The performance of the modified single-stage turbine and of two comtemporary high-stage-loading-factor turbines is compared with that estimated with a reference prediction method.

Whitney, W. J.↗

An overview of aerospace gas turbine technology of relevance to the development of the automotive gas turbine engine

Technology areas related to gas turbine propulsion systems with potential for application to the automotive gas turbine engine are discussed. Areas included are: system steady-state and transient performance prediction techniques, compressor and turbine design and performance prediction programs and effects of geometry, combustor technology and advanced concepts, and ceramic coatings and materials technology.

Evans, D. G.↗

An overview of aerospace gas turbine technology of relevance to the development of the automotive gas turbine engine

The NASA-Lewis Research Center (LeRC) has conducted, and has sponsored with industry and universities, extensive research into many of the technology areas related to gas turbine propulsion systems. This aerospace-related technology has been developed at both the component and systems level, and may have significant potential for application to the automotive gas turbine engine. This paper summarizes this technology and lists the associated references. The technology areas are system steady-state and transient performance prediction techniques, compressor and turbine design and performance prediction programs and effects of geometry, combustor technology and advanced concepts, and ceramic coatings and materials technology.

Evans, D. G.↗

Cold-air performance of free power turbine designed for 112-kilowatt automotive gas-turbine engine 3: Effect of stator vane end clearances on performance

An experimental investigation of a free power turbine designed for a 112-kW, automotive, gas turbine engine was made to determine the penalty in performance due to the stator vane end clearances. Tests were made over a range of mean section stator vane angles from 26 deg to 50 deg (as measured from the plane of rotation) with the vane end clearances filled. These results were compared with test results of the same turbine with vane end clearances open. At design equivalent values of rotative speed and pressure ratio and at a vane angle of 35 deg, the mass flow with the vane and clearances filled was about 8 percent lower than mass flow with vane end clearances open. The decrease in mass flow was mitigated by increasing the vane angle. With the vane end clearances filled, there was about a 66 percent reduction in mass flow when the vane angle was decreased from 40 deg to 26 deg. For the same decrease in vane angle the stator throat area decreased by about 50 percent. This result indicates that the rotor losses were increasing with decreasing vane angle.

Kofskey, M. G.↗

Algorithm for calculating turbine cooling flow and the resulting decrease in turbine efficiency

An algorithm is presented for calculating both the quantity of compressor bleed flow required to cool the turbine and the decrease in turbine efficiency caused by the injection of cooling air into the gas stream. The algorithm, which is intended for an axial flow, air routine in a properly written thermodynamic cycle code. Ten different cooling configurations are available for each row of cooled airfoils in the turbine. Results from the algorithm are substantiated by comparison with flows predicted by major engine manufacturers for given bulk metal temperatures and given cooling configurations. A list of definitions for the terms in the subroutine is presented.

Gauntner, J. W.↗

Energy efficient engine: Turbine intermediate case and low-pressure turbine component test hardware detailed design report

A four stage, low pressure turbine component has been designed to power the fan and low pressure compressor system in the Energy Efficient Engine. Designs for a turbine intermediate case and an exit guide vane assembly also have been established. The components incorporate numerous technology features to enhance efficiency, durability, and performance retention. These designs reflect a positive step towards improving engine fuel efficiency on a component level. The aerodynamic and thermal/mechanical designs of the intermediate case and low pressure turbine components are presented and described. An overview of the predicted performance of the various component designs is given.

Leach, K.↗

Investigation of Turbines Suitable for Use in a Turbojet Engine with High Compressor Pressure Ratio and Low Compressor-tip Speed VI: Experimental Performance of Two-stage Turbine

The brake internal efficiency of the highly loaded two-stage turbine was 0.79 equivalent design work and speed. The maximum brake internal efficiency was 0.84. A radial survey revealed these major defects: (1) the first-rotor throat area was too large, and a large area of underturned flow existed near the tip;(2) considerable underturning existed at the second-stator outlet; and (3) tangential components of velocity at the turbine outlet amounted to 2.5 points in turbine efficiency.

Davison, Elmer H↗

Fundamentals of the Control of Gas-Turbine Power Plants for Aircraft: Standardization of the Computations Relating to the Control of Gas-Turbine Power Plants for Aircraft by the Employment of the Laws of Similarity - Part 1

It will be shown that by the use of the concept of similarity a simple representation of the characteristic curves of a compressor operating in combination with a turbine may be obtained with correct allowance for the effect of temperature. Furthermore, it bec~mes possible to simplify considerably the rather tedious investigations of the behavior of gas-turbine power plants under different operating conditions. Characteristic values will be derived for the most important elements of operating behavior of the power plant, which will be independent of the absolute valu:s of pressure and temperature. At the same time, the investigations provide the basis for scale-model tests on compressors and turbines.

Luehl, H.↗

Turbine component and methods of making and cooling a turbine component

A turbine component includes a root and an airfoil extending from the root to a tip opposite the root. The airfoil forms a leading edge and a trailing edge portion extending to a trailing edge. Radial cooling channels in the trailing edge portion of the airfoil permit radial flow of a cooling fluid through the trailing edge portion. Each radial cooling channel has a first end at a lower surface at a root edge of the trailing edge portion or at an upper surface at a tip edge of the trailing edge portion and a second end opposite the first end at the lower surface or the upper surface. A method of making a turbine component and a method of cooling a turbine component are also disclosed.

Dutta, Sandip↗

Thermo-economic analysis of a solid oxide fuel cell-gas turbine hybrid with commercial off-the-shelf gas turbine

The thermodynamic and economic performance of a natural gas-fueled solid oxide fuel cell (SOFC)-gas turbine (GT) hybrid system with a commercial off-the-shelf GT is investigated. Until today, commercial GTs are primarily engineered for the direct use of energy dense fuels, such as natural gas, and the integration of commercial GTs into a SOFC-GT hybrid remains challenging. In this work technically feasible and economically viable GT operating modes are identified to gauge the technology’s competitiveness on the free market. Steady state, full load operating conditions were established for various GT operating modes: I) constant spool speed operation, II) variable spool speed operation and III) partially closed compressor inlet guide vanes. For each GT operating mode, the performance was investigated over a range of SOFC fuel utilization factors, while considering physical constraints inside the SOFC, such as local temperature gradients in flow direction as well as overall cell temperature differences. The results of the thermodynamic evaluation served as inputs for the economic analysis of the SOFC-GT hybrid power plant. The results show that the integration of an off-the-shelf GT not only results in a significant derating of the GT, but also substantially impacts the SOFC operation, the main power producer in this SOFC-GT hybrid. To maximize the SOFC power output it is desirable operate the GT in a region of high air mass flow rates and low pressure ratios, which increases the number of stacks that can be accommodated and reduces the SOFC cooling requirement. The lowest costs of electricity are obtained at constant spool speed operation, while the highest efficiencies are reached at variable spool speed operation. Critical for the integration of off-the-shelf GTs, which historically have been designed for natural gas, is the surge margin. The largest surge margins are obtained by closing the compressor inlet guide vanes. Furthermore, higher SOFC fuel utilization factors are shown to increase the surge margin as the turbine firing temperature is decreased.

25 ENERGY STORAGE↗