Search NASA⌕ Search

SEARCH · Search NASA

Results for “Temperature Mapping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Millimeter-wave observations of Euclid Deep Field South using the South Pole Telescope: A data release of temperature maps and catalogs

Context. The South Pole Telescope third-generation camera (SPT-3G) has observed over 10,000 square degrees of sky at 95, 150, and 220 GHz (3.3, 2.0, 1.4 mm, respectively) and will significantly overlap the ongoing 14,000 square-degree Euclid Wide Survey. The Euclid collaboration recently released Euclid Deep Field South (EDF-S) observations of 23 square degrees at wide field depths in the first quick data release (Q1). Aims. With the goal of releasing complementary millimeter-wave data and encouraging legacy science, we performed dedicated observations of a 57-square-degree field overlapping the EDF-S. Methods. The observing time totaled 20 days, and we reached noise depths of 4.3, 3.8, and 13.2 $μ$K-arcmin at 95, 150, and 220 GHz, respectively. Results. In this work we present the temperature maps and two catalogs constructed from these data. The emissive source catalog contains 601 objects (334 inside EDF-S) with 54% synchrotron-dominated sources and 46% thermal dust emission-dominated sources. The 5$σ$ detection thresholds are 1.7, 2.0, and 6.5 mJy in the three bands. The cluster catalog contains 217 cluster candidates (121 inside EDF-S) with median mass $M_{500c}=2.12 \times 10^{14} M_{\odot}/h_{70}$ and median redshift $z$ = 0.70, corresponding to an order-of-magnitude improvement in cluster density over previous tSZ-selected catalogs in this region (3.81 clusters per square degree). Conclusions. The overlap between SPT and Euclid data will enable a range of multiwavelength studies of the aforementioned source populations. This work serves as the first step toward joint projects between SPT and Euclid and provides a rich dataset containing information on galaxies, clusters, and their environments.

Archipley, M. [Chicago U., Astron. Astrophys. Ctr.↗

An analysis of the Venus thermal infrared temperature maps

A detailed analysis of the published Venus IR maps has been performed and a number of new results have been obtained. The global contour map of the average temperature variations in the vicinity of 6120 km reveals the existence of saddle points along the equator at dawn, at noon, and just before sunset. The hot spots observed at 4:30-4:40 A.M. at 65 deg to 68 deg S latitude appear to be in the vicinity of the coldest region from which the 8- to 14-micron emissions originate. At large earth zenith angles the limb darkening curves show a hump which is attributed primarily to a single patchy haze layer in the vicinity of 6123 km and with a thickness of the order of 3 km. An average IR source region temperature of 250 K is obtained at the equator. At the poles the same altitude region is 8 K cooler.

Ainsworth, J. E.↗

Observation of quenching-induced magnetic flux trapping using a magnetic field and temperature mapping system

Highly efficient superconducting radio-frequency cavities exhibit low heat loss and are used as components in accelerators and superconducting devices due to their high Q-values. The precise location of magnetic flux trapping in cavities is necessary to identify its effects on the performance of superconducting cavities. In this study, we report a new combined mapping system to measure the temperature and magnetic field on the equator. The proposed system comprehensively maps local magnetic field changes as magnetic flux trapping due to quenching. Our experimental results show that magnetic flux trapping due to quenching increases the local surface resistance of superconducting cavities at 2 K. Thus, the proposed system elucidates the relationship between local flux trapping due to quenching and surface resistance in superconducting cavities and highlights the effect of quenching on the surface resistance. This system can aid in the development of superconducting cavities with higher Q values.

43 PARTICLE ACCELERATORS↗

Infrared temperature mapping in elastohydrodynamic lubrication

An improved technique for the measurement of temperature distributions in an EHD conjunction is presented. The technique reported here employs the infrared radiation emitted by the EHD conjunction and appears more rigorous, more reliable, and less cumbersome than that reported previously by the authors. Detailed mapping of fluid temperature (averaged through the thickness) and the ball surface temperature can be obtained. These temperature distributions have been reported for a naphthenic mineral oil for peak Hertz pressures of 1.05 and 1.51 GN/sq m (148 and 219 kpsi), at sliding speeds ranging from 0.35 to 12.7 m/s (13.4 to 500 ips) and a bath temperature of 40 C.

Ausherman, V. K.↗

Infrared temperature maps of EHD lubrication

Technique uses an infrared detector with two specially selected infrared filters, in separately mapping the contact-surface temperature and average oil-film temperature in an elastohydrodynamic conjunction. Apparatus includes conventional four-ball bearing tester and temperature controlled lubricant system.

Sanborn, D. M.↗

Temperature Mapping of Nitrogen-doped Niobium Superconducting Radiofrequency Cavities

It was recently shown that diffusing nitrogen on the inner surface of superconducting radiofrequency (SRF) cavities at high temperature can improve the quality factor of the niobium cavity. However, a reduction of the quench field is also typically found. To better understand the location of rf losses and quench, we used a thermometry system to map the temperature of the outer surface of ingot Nb cavities after nitrogen doping and electropolishing. Surface temperature of the cavities was recorded while increasing the rf power and also during the quenching. The results of thermal mapping showed no precursor heating on the cavities and quenching to be ignited near the equator where the surface magnetic field is maximum. Hot-spots at the equator area during multipacting were also detected by thermal mapping.

43 PARTICLE ACCELERATORS↗

Gas-Phase Temperature Mapping of Evaporating Microdroplets

Evaporation is a ubiquitous and complex phenomenon of importance to many natural and industrial systems. Evaporation occurs when molecules near the free interface overcome intermolecular attractions with the bulk liquid. As molecules escape the liquid phase, heat is removed, causing evaporative cooling. The influence of evaporative cooling on inducing a temperature difference with the surrounding atmosphere as well as within the liquid is poorly understood. Here, we develop a technique to overcome past difficulties encountered during the study of heterogeneous droplet evaporation by coupling a piezo-driven droplet generation mechanism to a controlled micro-thermocouple to probe microdroplet evaporation. The technique allowed us to probe the gas-phase temperature distribution using a micro-thermocouple (50 μm) in the vicinity of the liquid–vapor interface with high spatial (±10 μm) and temporal (±100 ms) resolution. We experimentally map the temperature gradient formed surrounding sessile water droplets having varying curvature dictated by the apparent advancing contact angle (100° ≲ θ ≲ 165°). The experiments were carried out at temperatures below and above ambient for a range of fixed droplet radii (130 μm ≲ R ≲ 330 μm). Our results provide a primary validation of the centuries-old theoretical framework underpinning heterogeneous droplet evaporation mediated by the working fluid, substrate, and gas thermophysical properties, droplet apparent contact angle, and droplet size. We show that microscale droplets residing on low-thermal-conductivity substrates such as glass absorb up to 8× more heat from the surrounding gas compared to droplets residing on high-thermal-conductivity substrates such as copper. Finally, our work not only develops an experimental understanding of the heat transfer mechanisms governing droplet evaporation but also presents a powerful platform for the study and characterization of liquid–vapor transport at curved interfaces wetting and nonwetting advanced functional surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of AlN/AlGaN/GaN metal-insulator-semiconductor structure by using capacitance-frequency-temperature mapping

AlN/AlGaN/GaN metal-insulator-semiconductor (MIS) structure is analyzed by using capacitance-frequency-temperature (C-f-T) mapping. Applying sputtering-deposited AlN, we attained AlN/AlGaN/GaN MIS heterostructure field-effect transistors with much suppressed gate leakage currents, but exhibiting frequency dispersion in C-V characteristics owing to high-density AlN/AlGaN interface states. In order to investigate the interface states deteriorating the device performance, we measured temperature-dependent frequency dispersion in the C-V characteristics. As a result, we obtained C-f-T mapping, whose analysis gives the activation energies of electron trapping, namely the interface state energy levels, for a wide range of the gate biases. This analysis method is auxiliary to the conventional conductance method, serving as a valuable tool for characterization of wide-bandgap devices with deep interface states. From the analysis, we can directly evaluate the gate-control efficiency of the devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nanoscale temperature mapping in operating microelectronic devices

We report that modern microelectronic devices have nanoscale features that dissipate power nonuniformly, but fundamental physical limits frustrate efforts to detect the resulting temperature gradients. Contact thermometers disturb the temperature of a small system, while radiation thermometers struggle to beat the diffraction limit. Exploiting the same physics as Fahrenheit’s glass-bulb thermometer, we mapped the thermal expansion of Joule-heated, 80-nanometer-thick aluminum wires by precisely measuring changes in density. With a scanning transmission electron microscope (STEM) and electron energy loss spectroscopy (EELS), we quantified the local density via the energy of aluminum’s bulk plasmon. Rescaling density to temperature yields maps with a statistical precision of 3 kelvin/hertz ₋1/2 , an accuracy of 10%, and nanometer-scale resolution. Lastly, many common metals and semiconductors have sufficiently sharp plasmon resonances to serve as their own thermometers.

47 OTHER INSTRUMENTATION↗

An imaging system for quantitive surface temperature mapping using two-color thermographic phosphors

A technique for obtaining detailed quantitative temperature distributions on test models in hypersonic wind tunnels is presented. This technique is based on the ratio of blue to green (450, 520 nm) emission from an UV (365 nm) excited phosphor coating. Separately filtered images are recorded from a three-tube color camera, utilizing off-the-shelf front-end video optics to discriminate wavelengths. Two demonstration studies in a 31-inch Mach 10 tunnel are discussed. One study presents the windward surface temperature-time history for a transatmospheric vehicle, and the other illustrates nosetip heating on a spherically blunted slender cone.

Buck, Gregory M.↗

Temperature Maps of Clusters of Galaxies

We have progressed on our analysis of the temperature structure of clusters of galaxies. This report addresses the following areas: (1) merging clusters; (2) mass distributions; (3) temperature structures of clusters.

Forman, William R.↗

Gate-control efficiency and interface state density evaluated from capacitance-frequency-temperature mapping for GaN-based metal-insulator-semiconductor devices

We present an analysis method for GaN-based metal-insulator-semiconductor (MIS) devices by using capacitance-frequency-temperature (C-f-T) mapping to evaluate the gate-control efficiency and the interface state density, both exhibiting correlations with the linear-region intrinsic transconductance. The effectiveness of the method was exemplified by application to AlN/AlGaN/GaN MIS devices to elucidate the properties of AlN-AlGaN interfaces depending on their formation processes. Using the C-f-T mapping, we extract the gate-bias-dependent activation energy with its derivative giving the gate-control efficiency, from which we evaluate the AlN-AlGaN interface state density through the Lehovec equivalent circuit in the DC limit. It is shown that the gate-control efficiency and the interface state density have correlations with the linear-region intrinsic transconductance, all depending on the interface formation processes. In addition, we give characterization of the AlN-AlGaN interfaces by using X-ray photoelectron spectroscopy, in relation with the results of the analysis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cooling Dynamics Through Transition Temperature of Niobium SRF Cavities Captured by Temperature Mapping

Cool-down dynamics of superconducting accelerating cavities became particularly important for obtaining very high quality factors in SRF cavities. Previous studies proved that when cavity is cooled fast, the quality factor is higher than when cavity is cooled slowly. This has been discovered to derive from the fact that a fast cool-down allows better magnetic field expulsion during the superconducting transition. In this paper we describe the first experiment where the temperature all around the cavity was mapped during the cavity cool-down through transition temperature, proving the existence of two different transition dynamics: a sharp superconducting-normal conducting transition during fast cool-down which favors flux expulsion and nucleation phase transition during slow cool-down, which leads to full flux trapping.

43 PARTICLE ACCELERATORS↗

Lensing-induced morphology changes in CMB temperature maps in modified gravity theories

Lensing of the Cosmic Microwave Background (CMB) changes the morphology of pattern of temperature fluctuations, so topological descriptors such as Minkowski Functionals can probe the gravity model responsible for the lensing. We show how the recently introduced two-to-two and three-to-one kurt-spectra (and their associated correlation functions), which depend on the power spectrum of the lensing potential, can be used to probe modified gravity theories such as f ( R ) theories of gravity and quintessence models. We also investigate models based on effective field theory, which include the constant-Ω model, and low-energy Hořava theories. Estimates of the cumulative signal-to-noise for detection of lensing-induced morphology changes, reaches O(10{sup 3}) for the future planned CMB polarization mission COrE{sup +}. Assuming foreground removal is possible to ℓ{sub max}=3000, we show that many modified gravity theories can be rejected with a high level of significance, making this technique comparable in power to galaxy weak lensing or redshift surveys. These topological estimators are also useful in distinguishing lensing from other scattering secondaries at the level of the four-point function or trispectrum. Examples include the kinetic Sunyaev-Zel'dovich (kSZ) effect which shares, with lensing, a lack of spectral distortion. We also discuss the complication of foreground contamination from unsubtracted point sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Expansion Behavior and Temperature Mapping of Thermites in Burn Tubes as a Function of Fill Length [Thermal Imaging of Thermite Flame Propagation]

The reaction of loosely-packed aluminum/copper oxide (Al/CuO) thermites in a 12 cm long acrylic burn tube was investigated as a function of the fill length from 2 to 10 cm. The velocity of the luminous front was measured both in the filled and unfilled region, and approached 1000 m s-1 in the unfilled region, independent of the fill length. This value is approximately a factor of two higher than the fastest velocity measured in the filled region, 606 m s-1, for the 10 cm filled tube. The velocity increase in the unfilled region ist likely due to the increased open porosity, which can support faster flow velocities for a given pressure gradient relative to that in the porous material. A high-speed color imaging pyrometer was used to thermally map the evolution of the flame in both regions. Near the luminous front in the filled section, the temperature was observed to rapidly increase in a 1–2 cm zone to a maximum value near 3200 K, and an average value near 3000 K was sustained in the wake well after the front passes and exits the tube. In partially-filled tubes, even for the lowest fill length of 2 cm, the intermediate and/or product species could be seen to expand forward and completely fill the tube with a sustained temperature of ca. 3000 K. This temperature did not decay during the expansion, suggesting that the material continues to react as it expands. The results raise several questions about what a burn tube experiment is really measuring; such as what fraction of the material has burned when the luminous front passes and what role open cracks or microstructures play in promoting transport. Lastly, these questions are critically important towards developing a predictive capability for confined, loosely packed deflagrations.

36 MATERIALS SCIENCE↗