Polymer deformation gage measures thickness change in tensile tests

Lightweight deformation gage attached to a polymer specimen determines the thickness changes undergone by the specimen during the testing of its tensile and elongation properties. Mechanical noise from outside sources is dampened when the assembly is hung on a light rubber band.

Broyles, H. F.

Mechanical Tensile Testing of Hiperco 50A at Cryogenic Temperature

Hiperco 50A is a highly desired material for use in cryogenic applications, specifically for adiabatic demagnetization refrigerators (ADRs) due to its magnetic field shielding capabilities. Although the alloy has good strength, there is a concern with the material's brittle behavior which is believed to worsen at low temperature based on previous tests. The testing described here investigates the mechanical properties of Hiperco 50A at cryogenic temperature through mechanical tensile testing to failure and evaluation of the failed coupons. The methods and techniques used to determine the elongation, yield strength, ultimate tensile strength, and break strength of the material as well as the results will be presented here.

material properties

Manual for LDEF tensile tests

One of the experiments aboard the NASA Long Duration Exposure Facility (LDEF) consists of a tray of approximately one hundred tensile specimens of several candidate space structure composite materials. During the LDEF flight the materials will be subjected to the space environment and to possible contamination during launch and recovery. Tensile tests of representative samples were made before the LDEF flight to obtain baseline data. Similar tests will be made on control specimens stored on earth for the length of the LDEF flight and on recovered flight specimens. This manual codifies the details of testing, data acquisition, and handling used in obtaining the baseline data so that the same procedures and equipment will be used on the subsequent tests.

Witte, W. G., Jr.

Interaction of heat production, strain rate and stress power in a plastically deforming body under tensile test

At high strain rates the heat produced by plastic deformation can give rise to a rate dependent response even if the material has rate independent constitutive equations. This effect has to be evaluated when interpreting a material test, or else it could erroneously be ascribed to viscosity. A general thermodynamic theory of tensile testing of elastic-plastic materials is given in this paper; it is valid for large strain at finite strain rates. It enables discovery of the parameters governing the thermodynamic strain rate effect, provides a method for proper interpretation of the results of the tests of dynamic plasticity, and suggests a way of planning experiments in order to detect the real contribution of viscosity.

Paglietti, A.

Modifications of system for elevated temperature tensile testing and stress-strain measurement of metal matrix composites

Composites consisting of tungsten alloy wires in superalloy matrices are being studied because they offer the potential for increased strength compared to current materials used at temperatures up to at least 1093 C (2000F). Previous research at the NASA Lewis Research Center and at other laboratories in the U.S., Europe, and Japan has demonstrated laboratory feasibility for fiber reinforced superalloys (FRS). The data for the mechanical and physical properties used to evaluate candidate materials is limited and a need exists for a more detailed and complete data base. The focus of this work is to develop a test procedure to provide a more complete FRS data base to quantitatively evaluate the composite's potential for component applications. This paper will describe and discuss the equipment and procedures under development to obtain elevated temperature tensile stress-strain, strength and modulus data for the first generation of tungsten fiber reinforced superalloy composite (TFRS) materials. Tensile stress-strain tests are conducted using a constant crosshead speed tensile testing machine and a modified load-strain measuring apparatus. Elevated temperature tensile tests are performed using a resistance wound commercial furnace capable of heating test specimens up to 1093 C (2000 F). Tensile stress-strain data are obtained for hollow tubular stainless steel specimens serving as a prototype for future composite specimens.

Diaz, J. O.

A microdynamic version of the tensile test machine

Very large space structures require structural reactions to control forces associated with nanometer-level displacements; JPL has accordingly built a tensile test machine capable of mN-level force measurements and nm-level displacement measurements, with a view to the study of structural linear joining technology at the lower limit of its resolution. The tester is composed of a moving table that is supported by six flexured legs and a test specimen cantilevered off the table to ground. Three vertical legs contain piezoactuators allowing changes in length up to 200 microns while generating axial load and bending moments. Displacements between ground and table are measured by means of three laser-interferometric channels.

Glaser, R. J.

Optical strain measuring techniques for high temperature tensile testing

A number of optical techniques used for the analysis of in-plane displacements or strains are reviewed. The application would be for the high temperature, approximately 1430 C (2600 F), tensile testing of ceramic composites in an oxidizing atmosphere. General descriptions of the various techniques and specifics such as gauge lengths and sensitivities are noted. Also, possible problems with the use of each method in the given application are discussed.

Gyekenyesi, John Z.

Emerging hierarchical dislocation structures: Insights from scanning electron microscopy-electron backscatter diffraction in situ tensile testing and multifractal analysis

Understanding the evolution of dislocation structures during plastic deformation is critical for predicting the mechanical performance of metallic materials. In this work, we applied in situ scanning electron microscopy/electron backscatter diffraction tensile testing combined with multifractal (MF) analysis to assess deformation-induced dislocation structure evolution in solution-annealed 304 L stainless steel, both in its as-received and neutron-irradiated states (5.4 displacements per atom). The analysis of kernel average misorientation patterns revealed the formation of hierarchical dislocation arrangements that exhibit clear MF scaling behavior. Despite pronounced visual differences between nonirradiated and irradiated specimens—most notably, the appearance of dislocation channels after irradiation—the singularity spectra suggest that both conditions give rise to similar underlying hierarchical structures. MF analysis provides a quantitative measure of the spatial complexity and self-organization of dislocation patterns, highlighting the accelerated emergence and evolution of the dislocation structures in irradiated polycrystalline materials, as well as the limitation of their spatial extent. The findings indicate that irradiation not only modifies microstructure but also alters correlation-driven dislocation organization. More generally, they demonstrate that MF analysis is a powerful tool for probing mesoscale deformation mechanisms.

Dislocation structures

Assessing Flow Formability of Aerospace Aluminum Alloys via DIC Tensile Testing

Over the past decade, NASA Langley Research Center (LaRC) has championed integrally stiffened cylinder (ISC) technology for single-piece, cryogenic tank barrels on launch vehicles. The current investigation aims to extend the hybrid spin/shear/flow forming process to aircraft fuselage structures, a damage tolerance critical application. The WF Maschinenbau VUD-600® vertical spin/flow forming facility recently established at LaRC represents a reasonable sub-scale facsimile of the ISC deformation process for research and development (R&D) purposes. The objective of this study is to explore whether tensile testing with digital image correlation (DIC) is an effective way to rank the formability of candidate aerospace Al alloys and expedite empirical forming trials. Specific tensile data, such as reduction of area, strain hardening exponent, and modulus of resilience, are used as formability metrics for a variety of alloy/temper/product form combinations. Results from high-strength aluminum alloys AA 2139, AA 2050, AA 2043 and AA 2219 are compared with the medium-strength, highly formable AA 6061 benchmark. Rolled, forged and cast preform materials in both the -O temper (fully annealed) and -T4 temper (solution-treated, quenched, and naturally aged) conditions are evaluated. AA 2139 plate in the -T4 temper emerges as the top-ranked material, based on the criteria selected. Starting with preforms in the -T4 temper will result in flow-formed material exhibiting mechanical properties closer to aircraft fuselage requirements. The optimum balance between strength and damage tolerance may also be achieved via post-forming procedures that avoid quenching and stretching.

Aluminum alloys

Tensile test of pressureless-sintered silicon nitride at elevated temperature

Uniaxial tensile strength tests of pressureless sintered silicon nitride were carried out in air at temperatures ranging from room temperature up to 1600 C. Silicon nitrides containing Y2O3, Al2O3, Al2O3-MgO, or MgO-CeO2 additives were tested. The results show that the composition of the additive used influences the strength characteristics of the silicon nitride. The tensile strength rapidly decreased at temperatures above 1000 C for the materials containing MgO as the additive and above 1000 C for the material with Y2O3. When the temperature increased to as high as 1300 C, the strength decreased to about 10 percent of the room temperature strength in each case. Observations of the fracture origin and of the crack propagation on the fracture surfaces are discussed.

Matsusue, K.

High-Temperature Mechanical Tensile Testing of Unidirectional Sic/Sic Composites Using A Versatile Lamp Furnace

Silicon carbide (SiC) based ceramic matrix composites (CMCs) are of interest for high-temperature structural applications, including use in turbine engine components. To understand damage mechanisms and predict durability of these systems, in-depth knowledge of their behavior at ambient and high temperatures is necessary. A method for high temperature testing of SiC/SiC minicomposite specimens up to 1500oC in both tensile fast fracture and creep conditions to investigate their thermomechanical behavior will be presented. This method utilizes a novel radiation heat furnace, equipped with infrared lamps with ellipsoidal reflectors, to heat the specimen at the furnace center in user-defined atmospheres. The housing structure of the lamps allows for observation of the specimen during testing using optical methods and for conducting other experimental studies. The goal is to employ nondestructive health monitoring techniques in-situ, including acoustic emission (AE), electrical resistance (ER), and digital image correlation (DIC) to evaluate damage initiation and evolution in the minicomposite specimens during tensile testing. Results from mechanical testing and nondestructive techniques will be presented. Electron microscopy and X-ray micro-computed tomography were used to further characterize specimen damage after testing.

Aeronautics

Baseline tensile tests of composite materials for LDEF (Long Duration Exposure Facility) exposure

Tensile specimens of five graphite fiber reinforced composite materials were tested at room temperature to provide baseline data for similar specimens exposed to the space environment in low-Earth orbit on the NASA Long Duration Exposure Facility. All specimens were 4-ply (+ or - 45 deg)s layups; at least five replicate specimens were tested for each parameter evaluated. Three epoxy-matrix materials and two polysulfone-matrix materials, several fiber volume fractions, and two sizes of specimen were evaluated. Stress-strain and Poisson's ratio-stress curves, ultimate stress, strain at failure, secant modulus at 0.004 strain, inplane shear stress-strain curves, and unidirectional shear modulus at .004 shear strain are presented.

Witte, William G.

An Evaluation of Some Current Practices for Short-Time Elevated-Temperature Tensile Tests of Metals

The effect of different testing practices on the short-time elevated-temperature tensile properties was determined for 2024-T3 aluminum-alloy, HM21A-T8 and HK31A-H24 magnesium-alloy, and 12 MoV stainless-steel sheet. Tests were made under single strain-rate and single head-speed conditions. A dual strain-rate test was also included. An evaluation of the effects of these practices is given for the tensile and yield strengths, the elongation in 2 inches, and the uniform elongation. The need for a uniform testing practice is demonstrated. Recommended practices suggested by different organizations are included.

Manning, Charles R., Jr.

Furnace for Tensile Testing of Flexible Ceramics

Ceramic cloth and thread tested quickly at temperatures up to 1,250 degree C. Tensile strengths of ceramic cloths and threads measured conveniently in new furnace at specified temperatures up to 1,250 degree C, using ordinary mechanical tester. Samples heated along part of their lengths in furnace slots. Interchangeable furnace chambers and matching heating elements sized to match size of tested ceramic material.

Smith, M.

The effect of dogbone sample size in the tensile testing of TATB-based plastic‑bonded explosive materials

Mechanical properties are of interest for many plastic‑bonded explosive (PBX) materials with tensile properties being of particular interest. Direct tensile measurements using dogbone-shaped samples are considered the gold standard, but they are fairly large, making testing more costly and less desirable from a safety perspective. We investigated whether the measured tensile strength depends on the dogbone specimen size, which to our knowledge, has not been reported in the literature for PBX materials. Understanding this should inform the feasibility of employing smaller samples and how sample size should be considered when comparing PBX dogbone values in the literature. The TATB-based PBX dogbone sample size was varied by (a) scaling all dimensions proportionally and (b) varying only the length of the samples. It was observed that the measured tensile peak stress (strength) was a function of the sample size, and was more dependent on the diameter (cross-sectional area) than the length of the samples. Since peak stress is calculated as peak force normalized to the diameter of the sample, one might not expect an explicit diameter dependence for the peak stress. Therefore, these results suggest there may be an additional strengthening effect as the sample diameter is increased.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Tensile Tests of NACA and Conventional Machine-countersunk Flush Rivets

An investigation was conducted to determine and compare the tensile strength of NACA and conventional machine-countersunk flush rivets of several rivet-head angles and varying countersunk depth. The results of the investigation are presented in the form of curves that show the variation of the tensile strength of the rivet with the ratio of the sheet thickness to the rivet diameter. For the same rivet-head angle and for a given angle of c/d, the NACA rivets developed higher tensile strength than the conventional rivets.

RIVETS, COUNTERSUNK - NACA

Tensile Tests of Round-head, Flat-head, and Brazier-head Rivets

An investigation was conducted to determine the tensile strength of round-head (AN43C), flat-head(AN442), and brazier-head (AN4556) aluminum-alloy rivets because of the scarcity of information on the tensile strength of rivets. The results of the investigation are presented as curves that show the variation of the ratio of the tensile strength of the rivet to the tensile strength of the rivet crank with the ratio of the sheet thickness to the rivet diameter for the different types of rivet.

Schuette, Evan H