Search NASA⌕ Search

SEARCH · Search NASA

Results for “Testing Standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Transient Stability Preventive Control via Tuning the Parameters of Virtual Synchronous Generators

This paper presents an optimal preventive control (OPC) method to improve the power system transient stability via tuning the transient parameter of virtual synchronous generators. The novelty of this work is that we formulate the preventive control as an optimization problem so that inverter parameters can be adjusted at the pre-contingency stage. A reinforcement learning (RL)-driven method is proposed to solve the OPC problem with the fault energy-based reward function. An ANDES-based RL environment is also developed. Versatile functions included in the proposed environment have been presented in this paper. The proposed OPC formulation, the RLdriven method, and the fault energy-based reward function are verified on several standard test systems.

Inverter-based resources, virtual synchronous gene↗

ORNL Package Testing Program Overview

Radioactive materials are widespread in our everyday activities which are used in many different types of industries: Consumer products, Medicine, Industry, Energy, and Defense. In the United States there is about 3 million shipments of radioactive materials per year. With radioactive material being very widespread the number of new applications to ship these quantities increases daily. As such, ensuring the safe and secure transport of these materials is paramount, necessitating stringent packaging, transportation, and certification requirements. Shipments of radioactive materials have been made from Oak Ridge National Laboratory (ORNL) for the past 65 years. Since the 1940s ORNL has been at the forefront of the early development of regulations pertaining to the transport of radioactive shipments and associated regulatory testing. The early involvement resulted in ORNL being one of the leaders in the development of regulations and testing standards pertaining to the testing and design of packages. Today all package testing activities are conducted under the Package Testing Program (PTP) at ORNL at the Package Evaluation Facility (PEF). The PTP develops and evaluates testing solutions – ensuring that they are safe, efficient, and meet regulatory requirements ORNL PTP has extensive experience in the regulatory testing of radioactive material packages, supporting certification of Type A, Type, B, Type AF, and special form packages. The PEF serves as a one-stop-shop for design, testing, and certification of a wide variety of packages needed for shipment of radioactive materials. The facility provides the space, expertise, and equipment necessary to conduct rigorous performance testing under both normal and accident conditions or transport environments including free drop, dynamic crush, puncture, penetration, compression, vibration, water spray, water immersion, and thermal test. The PTP remains a key contributor to the safety and compliance of radioactive material transportation. This presentation will provide an overview of the program’s history, capabilities, and its ongoing role in advancing regulatory standards and transportation safety.

Martinez, Oscar [ORNL] (ORCID:0000000181814046)↗

Medium-Voltage Testbed for Comparing Advanced Power Line Sensors vs. Measurement Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medi-um-voltage sensor is compared with a reference PT and CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the US De-partment of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with integrator for current monitoring. The advanced outdoor power line sensor testbed has a real-time simulator that was used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, service restoration), while the analog signals were recorded by the same high resolution power meter. The behavior of analog signals, harmonic components, total harmonic distortion, and crest factors were assessed for this power line sensor compared with the reference PT/CT, because of the absence for testing standards for advanced outdoor power line sensors.

Piesciorovsky, Emilio↗

Laboratory Evaluation of the Thermal Breakout Method for Maximum Horizontal Stress Measurement

Measuring in situ stress is essential for many problems in geomechanics, and the maximum horizontal stress is the most difficult to constrain. We are developing an extension of the breakout method to measure maximum horizontal stress in regions where natural breakouts do not occur. In the novel thermal breakout method, additional compression which leads to breakout development is induced by heating the borehole wall. In the present study, we validated the method experimentally in a true-triaxial apparatus on samples with predrilled boreholes. Two rocks were selected for laboratory testing: high-porosity Berea sandstone and low-porosity Niagaran dolomite. Prior to main true-triaxial tests, we carried out standard testing to characterize the strength, elasticity and thermal properties. The true-triaxial experiments consisted of: (1) room-temperature tests where samples were first loaded mechanically until the breakout formed, and (2) elevated-temperature tests where samples were loaded mechanically within the elastic range with additional compression induced thermally. Breakout initiation was monitored by acoustic emission sensors mounted on the pistons that applied horizontal stresses. Furthermore, the magnitude of induced thermal stress was calculated from temperature measurements around the borehole wall. In both rock types, we created thermally induced breakouts and examined analytical expressions to constrain maximum horizontal stress based on strength, elastic and thermal properties of the rocks.

58 GEOSCIENCES↗

SDU7 Interior Liner Testing & Evaluation

The Saltstone Disposal Unit 7 (SDU7) project requested the Savannah River National Laboratory (SRNL), Materials Science & Engineering (MS&E) organization to evaluate an alternative bromobutyl liner and adhesives for potential use in SDU7 based on applicable ASTM testing standards. SRNL performed similar testing for the liner system used in SDU6. Bonded and non-bonded samples of the alternative liner (Blair Rubber Marflex™ RCHB60HT) were subjected to specific ASTM tests after immersion in two Saltstone leachate simulants, designated S1 and S2, for 1000 hours at 60 °C. Immersion exposures were performed at the Savannah River Ecology Laboratory (SREL). Post-immersion testing involved mechanical property and hardness testing of base material, lap-shear testing of bonded samples and rubber-to-concrete paver interrogation. The liner exhibited an approximate 40% drop in tensile strength and 25% drop in elongation at failure from baseline values after immersion, though final values are comparable to previous SDU6 liner values and are within liner manufacturer property ranges. Overall lap-shear strength behavior of the four adhesives showed a similar pattern, with short-term reduction and subsequent increase in peak load values. However, ranking of adhesives varied with the metric used for comparison. Two of the four adhesives tested (Normac 900 and REMA SC 4000) showed overall better behavior, collectively considering immersion performance, lap-shear data and bonded paver interrogation. Lap-shear samples bonded with the REMA adhesive showed the best combination of final retained bond strength, 6-week average bond strength and bond failure mode. Only one paver (REMA SC4000) was noted to have no defects after immersion. This document details the testing performed and provides conclusions and recommendations. The testing suggests that SDU liner performance is highly dependent upon seam integrity, which collectively depends on a combination of adhesive properties, installation workmanship and inspection/quality control.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Highly Integrated Wide Bandgap Power Module for Next Generation Plug-In Vehicles (Final Report)

Wide bandgap devices are key enablers for high power density traction inverters. A highly integrated wide bandgap (WBG) power module enables higher temperature operation, higher inverter efficiency and overall smaller die area with the same power delivery. However, it requires careful design of the power module to take advantage of all the superior material properties that silicon carbide (SiC) provides over conventional silicon (Si) Insulated Gate Bipolar Transistor (IGBT) based design. This project developed an efficient and densely packed SiC power module for an automotive traction inverter application. Extensive study was performed to select the best performing SiC die considering a wide range of temperature variation, suitability to integrate into target packaging, robust body diode performance and overall high electrical efficiency. Multiple design ideas were explored to achieve lower stray inductance for both power loop and signal loop, uniform current distribution, compact form factor, and very high thermal performance. The final power module package includes all six inverter switches in the same module (six-pack) with die sintered at both bottom and top surfaces utilizing high performance substrate to achieve high electrical and thermal performance. Two power module variants were developed using 900 V and 1200 V devices for operating at two different high voltage levels (> 600 V HV battery). Both power modules were comprehensively characterized, and high efficiency operation of the inverter was confirmed through analysis. Finally, a complete functional inverter was built with the 1200V power modules using other essential components (HV capacitors, gate driver board, controller board, current sensor, connectors etc.) and tested using GM’s standard test procedure. There are several challenges associated with adopting WBG devices for high voltage operation. In order to assess and mitigate those challenges, GM and subrecipients of this project have conducted multiple detailed studies. This includes phase current reconstruction using integrated Rogowski coil, device junction temperature estimation using on-state gate resistance, modeling and testing the effect of high voltage and fast switching on motor insulation and bearings, partial discharge inception voltage measurement under different environmental conditions. Findings of all these studies are summarized in this report.

33 ADVANCED PROPULSION SYSTEMS↗

Radiation Hardened Foam Cold Test Plan – Phase-I: Foam Adhesion, Contamination Fixation, Moisture Stresses, Pipe Cutting, and Thermal Profile Testing

This document outlines the Phase-I test objectives and implementation plan for a down-selective foam fixative technology intended to facilitate activities in support of the Savannah River Site (SRS) F/H labs deactivation and decommissioning (D&D) efforts. It is a collaborative effort between Savannah River National Laboratory (SRNL), Florida International University (FIU), and the SRS F/H labs team intended to test and evaluate the potential of an intumescent, fire-retardant foam in mitigating the release of contamination during dismantling operations on radioactively contaminated piping in legacy facilities. The cold test plan addresses specific requirements highlighted by site and safety personnel and will be executed in FIU’s Outdoor Test and Evaluation Facility using a mock-up that replicates the operational conditions at the proposed hot test location at F/H labs. Results from the cold test plan will inform the hot test at F/H labs, which will use the foam fixative to confine and/or isolate residual contamination within a 3-dimensional void space of Hastelloy C-22 piping designated for removal from the site and transported to a proper disposal facility. Phase-I testing will address eight test objectives: (1) evaluation of the adhesion and bonding properties of foam fixative in piping, (2) evaluation of the adhesion of the foam fixative in piping under varying moisture conditions, (3) determination of the heat profile of the foam fixative during curing, (4) determination of the relationship between pipe diameter and foam fixative quantity, (5) determination of the internal pipe pressure after foam deployment and curing, (6) development of a leak test standard operating procedure to test for the effectiveness of the foam plug, (7) initiation of a literature review to determine if using a hot tap is a viable method to deliver foam into piping, and (8) initiation of a 10-foot mock up test that will be used in Phase-II cold testing. The cold test will be conducted at FIU and all testing activities will comply with SRNL Conduct of R&D Protocols (SRNL-IM-2020-00019).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of Laboratory Test Methods for Low-Cost Indoor Air Quality Sensors

This report describes the development of two standard test methods: one for evaluating PM2.5 sensors; and the other for evaluating CO 2 Sensors. The standards were developed to provide a pathway for the use of reliable, low-cost indoor air quality sensors as occupant feedback, ventilation control, and overall indoor air quality improvement. This paper describes the development process and technical issues involved.

30 DIRECT ENERGY CONVERSION↗

Developing Equivalent Surface Heat Transfer Input Parameters for Updated Standard 140/BESTEST Thermal Fabric Test Cases

ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs, is widely cited for evaluating software for use with performance-path energy efficiency analysis in conjunction with well-known energy-efficiency standards, including: ASHRAE Standard 90.1, the International Energy Conservation Code, and other international standards. This paper summarizes recent work to develop improved equivalent surface heat transfer input parameters for the building thermal fabric comparative test cases that comprise a portion of Standard 140. The software-to-software comparative test method allows comparison of simulation results from a wide variety of building energy simulation programs to each other. In this type of test method, it is of great importance to specify inputs that are as well-equivalenced as possible to accommodate a wide variety of input schemes for the tested programs, and thereby reduce the potential for disagreements among them in the tests. Results include new alternative constant surface coefficients that are appropriate to the test cases and demonstrate their ability to approximate the more detailed surface heat transfer models from which they are derived.

BESTEST↗

Determination of Constraint-Independent Crack Tip Opening Angle for Stable Crack Growth in High-Strength Ductile Steels

The crack tip opening angle (CTOA) is one of fracture toughness parameters that has been used for decades in describing large stable crack growth in thin-walled aerospace structures under the low-constraint conditions. Recently, the pipeline industry has developed a growing interest in using the CTOA parameter to serve as the minimum required fracture toughness to arrest dynamic crack propagation in modern gas transmission pipelines made of high-strength ductile steel. To meet this industrial need, the CTOA test standard ASTM E3039 was therefore developed for measuring the constant critical CTOA. ASTM E3039 recommends a drop weight tearing test (DWTT) specimen with a shallow crack for standard CTOA testing, but its CTOA may depend on the low constraint condition of the DWTT specimen at the crack tip. Verifying the constraint independence of the DWTT-measured CTOA thus becomes indispensable for applying CTOA toughness to the running fracture control in the pipeline design. For this purpose, the present paper evaluates critical CTOA values in a set of fracture toughness tests on single-edge notched bend (SENB) specimens with shallow and deep cracks, based on four CTOA estimation models. Among these, the Ln(P)-LLD linear fit model is similar to that recommended by ASTM E3039 for CTOA calculation. Fracture test data for X80 pipeline steel and HY80 structural steel were considered in the CTOA evaluation. The results showed that the four CTOA models were able to determine a constraint independent CTOA value for stable crack growth in the SENB specimens. As a result, a single, reliable, constant CTOA value could be determined regardless of the specimen geometry or the crack-tip constraint conditions. Therefore, the CTOA measured using ASTM E3039 is constraint-independent and transferable to use in cases of actual cracks propagating in gas transmission pipelines.

36 MATERIALS SCIENCE↗

Staying cool: The development of India's pioneering energy efficiency policy for chillers

Abstract Chillers are the key energy‐consuming piece of equipment in most large space cooling systems. They can account for more than 40% of total energy consumption in any typical commercial building and in specific industrial building installations depending on the product and process. With climate change driving rapidly rising demand for commercial and industrial cooling, especially in emerging economies, energy efficiency policies for chillers are crucial to moderate future electricity demand and thereby minimize greenhouse gas emissions. However, most developing and emerging economies lack energy efficiency policies for this significant and growing cooling equipment sector. India recently announced new energy efficiency policies for chillers, projected to avoid 28 TWh of electricity consumption and 23 million tons of CO 2 emissions cumulatively through 2030. This article presents a case study of the unique challenges and solutions required to design a new energy efficiency policy for chillers in India. First, the energy consumed in chiller systems is sensitive to building occupancy, load changes, seasonal variations, operation and maintenance, and climatic conditions. In order to address these sensitivities, the chiller testing standard in India factors local weather and temperature conditions into energy performance ratings to account for these sensitivities. Further, every large chiller is a customized product, therefore developing a viable policy and implementation process required collaboration with international and national experts in standardization, manufacturers, building consultants, and testing laboratories. This article is categorized under: Energy Efficiency > Economics and Policy Solar Energy: Thermal ‐‐> Climate and Environment

Mukherjee, P. K.↗

Evaluation of an LED Simulator for Single- and Multi-Junction PV Cell Performance Testing

We present the evaluation of a solar simulator comprising a Light Emitting Diode (LED) array as its light source. While multiple applications can be envisioned for such a light source, here we focus on its use for performance testing of solar cells at Standard Test Conditions. With this in mind, we present characterization of the spatial uniformity of the irradiance and its temporal stability as well as the spectral range and spectral class. For a multisource simulator, the spectral uniformity across the test plane should also be evaluated and we discuss a method for performing this evaluation that is well suited to a solar cell performance testing application. One major advantage of this simulator is the ability to easily adjust the spectral output as needed in multijunction PV cell measurements and we also discuss this application here.

LED↗

A Comparative Study on Representativeness and Stochastic Efficacy of Miniature Tensile Specimen Testing

Here, in this article, a miniature dog bone tensile coupon design was tested against the existing ASTM standard specimen design. Specimens were prepared from commercially sourced austenitic stainless steel 304 alloy, and a defect-ridden additively manufactured 304L alloy was studied. By utilizing a tensile specimen design that is 1/230th volume of the smallest ASTM E8-04(2016), Standard Test Methods for Tension Testing of Metallic Materials, dog bone specimen, coupled to a digital image correlation (DIC) setup, case studies were performed to compare tensile property measurements and strain field evolution. Whereas yield strength measurements were observed to be similar, post-yield, the ultimate strength measurements and ductility measurements from the miniature specimens were observed to be higher than the ASTM specimen design. Although the strength measurements were comparable, the strain evolution was found to differ in the miniature specimens. Studies to assess effects of varying thickness and defect population were also pursued on the miniature tensile specimen. From the DIC strain field estimations, the peak local strain values at ultimate tensile strength were observed to be increasing with reducing specimen thickness. Testing of defect ridden stainless steel revealed the sensitivity to failure through strain localization and the influence of defect size was captured in the strength measurements.

36 MATERIALS SCIENCE↗

Optimizing Bifacial PV Systems (Q3 FY2020 Project Report)

This project has four main technical objectives. Develop and improve bifacial performance models by adding the capability to evaluate electrical behavior and performance of bifacial modules and arrays under realistic field conditions including irradiance variability caused by racking, module frame, and position in the array. Instrument and monitor performance of fielded bifacial systems to validate performance models and to measure, analyze and publish on bifacial energy gain. These should include both research and commercial bifacial systems and cover a variety of deployment applications. Evaluate optimal bifacial system designs using simulations leveraging high performance computing, and also using full sized and miniaturized experimental field deployments. Establish and contribute to international test standards for bifacial system performance, testing, and safety, and work with the community to establish installation and siting best practices.

14 SOLAR ENERGY↗

2021 Q1 Project Report: Optimized Bifacial PV Systems (Q1 FY2021 Project Report)

This project has four main technical objectives: 1) Develop and improve bifacial performance models by adding the capability to evaluate electrical behavior and performance of bifacial modules and arrays under realistic field conditions including irradiance variability caused by racking, module frame, and position in the array. 2) Instrument and monitor performance of fielded bifacial systems to validate performance models and to measure, analyze and publish on bifacial energy gain. These should include both research and commercial bifacial systems and cover a variety of deployment applications. 3) Evaluate optimal bifacial system designs using simulations leveraging high-performance computing, and also using full sized and miniaturized experimental field deployments. 4) Establish and contribute to international test standards for bifacial system performance, testing, and safety, and work with the community to establish installation and siting best practices.

42 ENGINEERING↗

Non-contact Current-Voltage (I-V) Tracer for Photovoltaics

This report presents a non-contact approach to simultaneously obtain current-voltage (I-V) curves of photovoltaic (PV) substrings and modules in a string without the need of disconnecting the individual modules from the string. There are two types of I-V curve tracers currently available in the marketplace, capacitor-based and electronic load-based. The primary requirement of these conventional I-V tracers is the disconnection of individual modules in the string so the individual modules contacted through the connectors of the individual modules. These contact-tracers have three major limitations in the utility scale power plants: First limitation – Weather and Accuracy: The mass-produced commercial contact-tracers cannot obtain the I-V curves of both string and its modules (as high as 30 modules), almost simultaneously (within about 5 minutes) at, practically, a single irradiance level, a single module temperature, a single spectrum and a single AOI (angle of incidence). This inability of the contact-tracers forces the testing personnel to wait for an extended or multiple sunny (>800 W/m 2 ) duration(s) of a cloudy day. This is a serious limitation as waiting for the sunny conditions or days is a huge practical challenge in almost all locations, except desert locations. Also, since the I-V curves are obtained at different prevailing weather conditions, it becomes critical to translate all the measured I-V curves of 30 modules in the string to a single test condition, for example STC (standard test conditions), so the underperforming modules can be identified. The accuracy of translation equations is heavily influenced by the irradiance level and temperature, spectral and AOI ranges; Second limitation - Safety: The second limitation is related to the high voltage electrical safety of the test personnel during disconnecting and reconnecting of individual modules or cable connectors from the string under daylight conditions and damaging of the original module connectors (especially the field aged connectors) during the disconnecting and reconnecting process; Third limitation – Labor: The third limitation is related to the enormous amount of time and hardship for the test personnel under prevailing (often harsh) protracted field conditions. This project was executed by Arizona State University in collaboration with its industry partner, PV Measurements Inc. (PVM). To mitigate all the three challenges of the state-of-the-art equipment indicated above, we utilized a non-contact I-V (NCIV) tracer approach. In this approach, we utilized an electrostatic voltmeter (ESV) and voltage sensor/probe combination to obtain I-V curves. The ESV units are extensively used in the high voltage industry but not in the PV industry. To obtain the simultaneous I-V curves of the substrings and modules within a string, we utilized multiple commercial ESV-Probe sets. In this approach, we utilized a non-contact voltage sensor (called, Probe) placed on the glass surface of the module (above the last cell of the module). This probe senses the module voltage (with respect to ground) through measured capacitance which is dictated by the surface charges (which in turn is dictated by the module voltage) and transmits the sensed voltage to the voltmeter (called, ESV or NCV, non-contact voltmeter). The current is sensed by a non-contact hall sensor. In a 30-module string, the 30th probe obtains the entire string I-V along with the string I-V obtained by the electronic load. so that the I-V curves of the substrings and modules can be obtained by NCIV without the need of disconnecting the individual modules in the string. The string I-V curves obtained by the electronic load and NCIV can be compared for the accuracy determination. One can use 30 ESV units and 30 Probes to obtain 30 I-V curves of a 30-module string or use just 5 ESV units and 30 Probes in conjunction with 5 six-channel switchboxes (called, 6:1 switchboxes). To reduce the equipment cost, we utilized the 6:1 switchbox approach so the number of ESV units is reduced from 30 to 5. The approaches, achievements and challenges of this project are detailed in this report.

14 SOLAR ENERGY↗