Search NASASearch

SEARCH · Search NASA

Results for “Thermal Design and Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,565 records · Page 3

A Modular Conjugate Heat Transfer Optimization Framework for Thermal Management of Electric Aircraft

Conjugate heat transfer (CHT) analysis and optimization is a powerful method for improving thermal management, as it simultaneously resolves the temperature distribution in both fluid and solid domains. This paper presents a modular, discrete adjoint-based CHT optimization capability integrated within the OpenMDAO/MPhys framework. A unique feature of the proposed framework is its flexibility to extend to multidisciplinary optimization, including aero-structural-thermal applications. The fluid domain is modeled using a finite-volume Computational Fluid Dynamics (CFD) solver, and the solid domain with a conduction heat transfer solver. A mixed Neumann-Dirichlet boundary condition is developed to enable full submersion of the solid geometry within the fluid domain, while ensuring consistent temperature and heat flux coupling at the CHT interface. Gradient-based optimization is performed; the gradients are efficiently computed using the discrete adjoint solvers implemented in DAFoam. To demonstrate the method, this paper considers two cases related to electric aircraft thermal management: a U-bend heat exchanger and an actively cooled battery pack. The U-bend case aims to minimize pressure loss while maximizing heat flux by changing the pipe geometry. The optimized design reduces pressure loss by 52.7% and increases total heat flux by 2.3%. In the battery pack case, a 3-by-3 cell configuration is cooled by ambient airflow, with constant heat generation prescribed in the cells. The battery casing shape serves as the design variable, and the objective function is a weighted sum of pressure loss and pack weight, subject to a maximum temperature constraint. The optimized design achieves a 44.6% reduction in pressure loss and a 1.5% reduction in weight, while satisfying the thermal constraint. To ensure the reliability of the optimized designs, this study validates coarse-mesh, steady-state predictions against fine-mesh unsteady simulations, demonstrating consistency within acceptable errors. This work demonstrates the potential of the developed framework to enable rapid, high-fidelity design of thermal management systems for electric aircraft.

heat transfer

On the Stability Analysis of Astrophysical Cooling Functions

To model the temperature evolution of optically thin astrophysical environments at MHD scales, radiative and collisional cooling rates are typically either pretabulated or fit into a functional form and then input into MHD codes as a radiative loss function. Thermal balance requires estimates of the analogous heating rates, which are harder to calculate, and due to uncertainties in the underlying dissipative heating processes these rates are often simply parameterized. The resulting net cooling function defines an equilibrium curve that varies with density and temperature. Such cooling functions can make the gas prone to thermal instability (TI), which will cause departures from equilibrium. There has been no systematic study of thermally unstable parameter space for nonequilibrium states. Motivated by our recent finding that there is a related linear instability, catastrophic cooling instability, that can dominate over TI, here we carry out such a study. We show that Balbus instability criteria for TI can be used to define a critical cooling rate, Λc, that permits a nonequilibrium analysis of cooling functions through the mapping of TI zones. We furthermore illustrate how thermal conduction modifies the shape of TI zones. Upon applying a Λc-based stability analysis to coronal loop simulations, we find that loops undergoing periodic episodes of coronal rain formation are linearly unstable to catastrophic cooling instability, while TI is stabilized by thermal conduction.

Amanda Stricklan

Fuel injector design for high temperature aircraft engine

The objective of the Innovative High Temperature Aircraft Engine Fuel Nozzle Program was to design and evaluate a nozzle capable of operating at a combustor inlet air temperature of 1600 F (1144 K) and a fuel temperature of 350 F (450 K). The nozzle was designed to meet the same performance requirements and fit within the size envelope of a current production dual orifice fuel nozzle. The design approach was to use improved thermal protection and fuel passage geometry in combination with fuel passage surface treatment to minimize coking at these extreme fuel and air temperatures. Heat transfer models of several fuel injector concepts were used to optimize the thermal protection, while sample tube coking tests were run to evaluate the effect of surface finish, coatings and tube material on the coking rate. Based on heat transfer analysis, additional air gaps, reduced fuel passage flow area and use of ceramic tip components reduced local fuel wetted wall temperatures by more than 200 F (100 K) when compared to a current production fuel nozzle. Sample tube coking test results showed the importance of surface finish on the fuel coking rate. Therefore, a one micro-inch (0.025 micron) roughness was specified for all fuel passage surfaces. A novel flow divider valve in the tip was also employed to reduce weight, allow room for additional thermal protection, and provide back pressure to reduce the risk of fuel vaporization. The fuel nozzle was fabricated and evaluated in a series of high temperature coking tests. Initial results of these tests indicate that thermal protection and surface treatments were partially successful in preventing nozzle fouling, but additional refinement of the internal flowpath is needed to prevent buildup of coke particles that partially blocked the spin slots which meter the nozzle fuel flow.

R. W. Stickles

Multidisciplinary Design Optimization and Analysis of an Open Rotor Stage: Part 1

Successful design of open rotor propulsors requires effective analysis across multiple disciplines, including aerodynamics, acoustics, and structures. A viable design must not only be efficient but must also produce an acceptable level of noise and meet all static and dynamic structural requirements. For design and optimization, this is especially challenging because running high fidelity analyses is resource-intensive, and optimizing a design may require many thousands of cases to be analyzed. For this reason, the NASA team has applied design methodology that utilizes low-cost aerodynamic methods, machine learning models, and high-fidelity analyses when necessary. This includes standard two-dimensional methods such as throughflow analysis and quasi-3D blade-to-blade CFD, as well as some newly developed methods. Optimization using 3D CFD is necessary to maximize performance, and this is considered as well. All optimizations are carried out subject to structural constraints evaluated using finite element analysis. Doing this accurately requires a robust trunnion design, capable of pitching the blade between cruise and takeoff conditions while maintaining acceptable factor of safety. Hot to cold analysis must also be applied in order to correctly determine the as-manufactured shape. For acoustics, the unsteady pressures on the blade surfaces must be predicted, and this can be done either through full-annulus unsteady CFD or through a nonlinear harmonic method (NLH). NLH can run much faster, allowing some acoustic considerations to be made earlier in the design process. The design process is ongoing, and this presentation will review the current status and planned next steps. This part of the talk will focus on aerodynamic performance and be followed by a talk on structures and acoustics.

Design

NiCd battery failure analysis

The failure of a nickel cadmium battery undergoing tests is discussed. Reasons for the complete destruction of the battery while undergoing preparation for thermal vacuum testing are given.

Sense, K. A.

Improvement in the Thermal-to-Structural Model Mapping Process for Integrated Modeling for the Roman Space Telescope

Integrated Modeling has been a key component of verifying optical requirements for the Nancy Grace Roman Space Telescope (RST) that are either impossible or impractical to verify exclusively through ground testing. Two major areas for integrated Modeling are Jitter and Thermal Distortion that require the exchanges of model performance predictions across disciplines. In both cases, distortions are impressed on optical models to evaluate the impact on boresight alignment and wave front error. In the case of Jitter, the disturbances are driven by reactions to motions most often from actuators; however, in the case of thermal distortion, the motions are driven by thermal expansion or contraction as a result of changing temperatures. This then requires a link further upstream to the thermal model, which is used to predict the thermal performance and temperature gradients and stability. The process for mapping temperatures from a thermal model to a corresponding structural model has been performed numerous times through the RST project lifecycle, with improvements in the accuracy, verification, and effort sought throughout. This paper describes some of the recent improvements to the process, including: capture of the visualization parameters, automatic generation of the mapped images for both the thermal and structural model groupings, and reduction in the effort to assemble the full set of mapped temperatures. These upgrades have greatly reduced the manual effort associated with thermal mapping and allowed for faster turn-around of Integrated Modeling predictions.

Thermal Mapping

Impacts of Reduced Pressure Atmospheres on Environmental Control and Life Support Systems (ECLSS) Architectures

The study found that while nine subsystems are viable without modification at 10.2 psia, only three remain acceptable at 8.2 psia. Material flammability presents the most critical hurdle in the 8.2 psia/34-40% O 2 environment, where 70% of the assessed subsystems will require material replacements, many of which have yet to be developed. Ultimately, adapting ISS heritage hardware to these exploration conditions will introduce varied mass, power (e.g., increased fan speeds), and significant schedule impacts driven by the need for extensive testing, redesign, and recertification. The report concludes with specific recommendations for targeted analysis and testing to quantify these impacts and guide necessary design modifications.

Environmental Control and Life Support Systems

Form Factors, Grey Bodies and Radiation Conductances (Radks)

With today's analysis tools, large, complex thermal radiation problems are easily solved; But, as with any analytical tool, lack of an understanding of the fundamental equations and technique limitations may leave you with the wrong answer; Whether you are a new engineer or a seasoned veteran, an understanding of the techniques employed by these powerful analysis tools is crucial.

Fluids

RTE: A Computer Code for Rocket Thermal Evaluation

The numerical model for a rocket thermal analysis code (RTE) is discussed. RTE is a comprehensive thermal analysis code for thermal analysis of regeneratively cooled rocket engines. The input to the code consists of the composition of fuel/oxidant mixture and flow rates, chamber pressure, coolant temperature and pressure. dimensions of the engine, materials and the number of nodes in different parts of the engine. The code allows for temperature variation in axial, radial and circumferential directions. By implementing an iterative scheme, it provides nodal temperature distribution, rates of heat transfer, hot gas and coolant thermal and transport properties. The fuel/oxidant mixture ratio can be varied along the thrust chamber. This feature allows the user to incorporate a non-equilibrium model or an energy release model for the hot-gas-side. The user has the option of bypassing the hot-gas-side calculations and directly inputting the gas-side fluxes. This feature is used to link RTE to a boundary layer module for the hot-gas-side heat flux calculations.

Mohammad H N Naraghi

A Simplified Model of VIPER Thermal Management System. Part I: Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) uses a combination of loop heat pipes (LHPs) and heaters as the primary hardware to modulate the temperature of the electronic boxes and payloads instruments. LHPs have been designed and instrumented to be capable of passive and active shutdown. The goal of the passive shutdown, using a thermal control valve (TCV) to limit the flow of the working fluid, is to preserve thermal energy and avoid unnecessary heat leaks during lunar night. The goal of the active shutdown on the other hand, is to forcefully increase the vehicle internal temperature to bakeout the payload instruments. Several numerical modeling tools are available to analyze LHP performance under the complex set of operational requirements and environments levied on the VIPER Thermal Management System (TMS). Yet, while those numerical modeling tools are capable of detailed performance analysis, they tend to take large computational resources and long computational time. In this paper, a model of a single LHP developed based on control volume approach is presented. By using the control volume approach, the complex geometry of the LHP, and the components attached to it, are reduced to thermal lump capacitances, thus reducing the computation effort. This paper also describes the effort to correlate the proposed LHP model using thermal vacuum (TVAC) test data.

Loop Heat Pipe

A Simplified Model of VIPER Thermal Management System. Part I: Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) uses a combination of loop heat pipes (LHPs) and heaters as the primary hardware to modulate the temperature of the electronic boxes and payloads instruments. LHPs have been designed and instrumented to be capable of passive and active shutdown. The goal of the passive shutdown, using a thermal control valve (TCV) to limit the flow of the working fluid, is to preserve thermal energy and avoid unnecessary heat leaks during lunar night. The goal of the active shutdown on the other hand, is to forcefully increase the vehicle internal temperature to bakeout the payload instruments. Several numerical modeling tools are available to analyze LHP performance under the complex set of operational requirements and environments levied on the VIPER Thermal Management System (TMS). Yet, while those numerical modeling tools are capable of detailed performance analysis, they tend to take large computational resources and long computational time. In this paper, a model of a single LHP developed based on control volume approach is presented. By using the control volume approach, the complex geometry of the LHP, and the components attached to it, are reduced to thermal lump capacitances, thus reducing the computation effort. This paper also describes the effort to correlate the proposed LHP model using thermal vacuum (TVAC) test data.

Loop Heat Pipe

Heat Flow and Thermal History of the Moon

An analysis was made of current heat flow data and thermal models of lunar evolution which satisfy the diverse information that has accumulated on internal processes.

Ye A Lyubimova

NASA Alternative Orion Small Cell Battery Design Support

The NASA Orion Crew Module Reference Design was produced to address large scale thermal runaway (TR) hazard with specific safety controls for the Orion Spacecraft. The design presented provides the description of a full scale battery design reference for implementation as a drop in replacement to meet all spacecraft energy requirements with compatible 120 Vdc electrical and mechanical interface using small cell technology (18650) packaging. The 32V SuperBrick incorporates unique support features and an electrical bus bar arrangement that allows cells negative can insertion into heat sink that is compressively coupled to the battery enclosure to promote good thermal management. The housing design also provides an internal flame suppression "filter tray" and positive venting path internal to the enclosure to allow hot effluent ejecta to escape in the event of single cell TR. Virtual cells (14P Banks) that are supported to provide cell spacing with interstitial materials to prevent side can failures that can produce cell to cell TR propagation. These features were successfully test in four separate TR run with the full scale DTA1 test article in February 2016. Successfully Completed Test Objectives - Four separate TR test runs with Full-Scale DTA1 housing with Two SuperBricks, Two SuperBrick Emulators All Tests resulted in "clean" gas with less than 6 C rise at Battery vent All Tests resulted in less than 2 C temperature rise on cold-plate outlet All Tests resulted in less than 6 psi pressure rise in the battery housing Test Run 1 -One neighbor cell TR, highest remaining neighbor 139 C. Ejecta shorted to bus caused prolonged additional heating, One shorted cell did experience TR after 12 minutes, remaining cells had adequate thermal margin Test Run 2 - No cell to cell propagation, highest neighbor cell 112 C; Test Run 3 - No cell to cell propagation, highest neighbor cell 96 C; Test Run 4 - No cell to cell propagation, highest neighbor cell 101 C; Primary TR testing and analysis were completed and reviewed for endorsement by NASA Engineering and Safety Center team members. All Key Test Objectives were met and the small cell design alternative was demonstrated and selected to be a feasible drop in replacement for the MPCV Orion CM Battery for EM2 mission.

Haynes, Chuck

SMS/GOES cell and battery data analysis report

The nickel-cadmium battery design developed for the Synchronous Meteorological Satellite (SMS) and Geostationary Operational Environmental Satellite (GOES) provided background and guidelines for future development, manufacture, and application of spacecraft batteries. SMS/GOES battery design, development, qualification testing, acceptance testing, and life testing/mission performance characteristics were evaluated for correlation with battery cell manufacturing process variables.

Armantrout, J. D.

Prototype Demonstration of Solar-Carbothermal System to Extract Oxygen From Regolith

The Carbothermal Reduction Demonstration (CaRD) project was an effort to develop a prototype system to demonstrate the extraction of oxygen from simulated lunar regolith using concentrated solar energy and a carbothermal reaction. The prototype consisted of a deployable solar concentrator capable of tracking the sun, carbothermal reactor, fluid system, gas analysis, and a solar concentrator control system consisting of avionics and software. These subsystems were developed by multiple NASA centers and a private industry partner, Sierra Space. The various teams worked together to define requirements and interfaces to successfully assemble the complex system and demonstrate an integrated solar carbothermal process. The solar concentrator developed at Glenn Research Center (GRC) was designed to be stowed for a launch environment then deployed on the lunar surface. It utilized a crossed dragone configuration of composite mirrors to direct horizontal sunlight onto a target 90° from the incoming sunlight. The key performance parameters for the solar concentrator were efficiency and power density. The carbothermal reactor was developed by Sierra Space through a separate project called the Carbothermal Oxygen Production Reactor (COPR) where it successfully demonstrated a fully automated process in a thermal vacuum environment [1]. The fluid system needed for the carbothermal reaction was also developed by Sierra Space and successfully demonstrated in the same thermal vacuum test. The gas analysis system was developed at Kennedy Space Center (KSC) and was required to determine the amount of oxygen extracted during each test. The gas analysis system was based on the Mass Spectrometer Observing Lunar Operations (MSOLO) instrument. Avionics and software for the CaRD prototype were also developed at KSC and based on experience with MSOLO avionics and software. The control system was designed to stow, deploy, track the sun, and perform beam alignment of the concentrated light. The prototype subsystems were integrated and tested at Johnson Space Center’s (JSC) Energy Systems Test Area. A heliostat was used to direct sunlight toward the prototype in a way that is representative of the sunlight conditions at the south pole of the Moon. When concentrated sunlight was focused on simulated lunar regolith within the reactor, the gas analysis team confirmed the presence of carbon monoxide gas, which confirmed that a solar carbothermal reaction took place. The key performance parameter for the integrated prototype was grams of oxygen extracted per kilowatt hour of energy arriving at the concentrator primary mirror. The prototype design successfully demonstrated end-to-end capability and further steps to achieve a flight capable system have been defined. With lunar data, engineers would be able to design a scaled-up system capable of extracting oxygen from regolith at useful quantities for crew life support and rocket propellant. On the long term, this method of In-Situ Resource Utilization could be used to drastically reduce the cost and risk of a sustained human presence on the Moon by reducing the amount of oxygen that would have to be delivered.

Koorosh R Araghi

Prototype Demonstration of Solar Carbothermal System to Extract Oxygen from Regolith

The Carbothermal Reduction Demonstration (CaRD) project was an effort to develop a prototype system to demonstrate the extraction of oxygen from simulated lunar regolith using concentrated solar energy and a carbothermal reaction. The prototype consisted of a deployable solar concentrator capable of tracking the sun, carbothermal reactor, fluid system, gas analysis, and a solar concentrator control system consisting of avionics and software. These subsystems were developed by multiple NASA centers and a private industry partner, Sierra Space. The various teams worked together to define requirements and interfaces to successfully assemble the complex system and demonstrate an integrated solar carbothermal process. The solar concentrator developed at Glenn Research Center (GRC) was designed to be stowed for a launch environment then deployed on the lunar surface. It utilized a crossed dragone configuration of composite mirrors to direct horizontal sunlight onto a target 90° from the incoming sunlight. The key performance parameters for the solar concentrator were efficiency and power density. The carbothermal reactor was developed by Sierra Space through a separate project called the Carbothermal Oxygen Production Reactor (COPR) where it successfully demonstrated a fully automated process in a thermal vacuum environment. The fluid system needed for the carbothermal reaction was also developed by Sierra Space and successfully demonstrated in the same thermal vacuum test. The gas analysis system was developed at Kennedy Space Center (KSC) and was required to determine the amount of oxygen extracted during each test. The gas analysis system was based on the Mass Spectrometer Observing Lunar Operations (MSOLO) instrument. Avionics and software for the CaRD prototype were also developed at KSC and based on experience with MSOLO avionics and software. The control system was designed to stow, deploy, track the sun, and perform beam alignment of the concentrated light. The prototype subsystems were integrated and tested at Johnson Space Center’s (JSC) Energy Systems Test Area. A heliostat was used to direct sunlight toward the prototype in a way that is representative of the sunlight conditions at the south pole of the Moon. When concentrated sunlight was focused on simulated lunar regolith within the reactor, the gas analysis team confirmed the presence of carbon monoxide gas, which confirmed that a solar carbothermal reaction took place. The key performance parameter for the integrated prototype was grams of oxygen extracted per kilowatt hour of energy arriving at the concentrator primary mirror. The prototype design successfully demonstrated end-to-end capability and further steps to achieve a flight capable system have been defined. With lunar data, engineers would be able to design a scaled-up system capable of extracting oxygen from regolith at useful quantities for crew life support and rocket propellant. On the long term, this method of In-Situ Resource Utilization could be used to drastically reduce the cost and risk of a sustained human presence on the Moon by reducing the amount of oxygen that would have to be delivered.

Aaron Paz