Thermal Neutron Scattering Law for Beryllium Hydride and Critical Mass Calculations [Slides]

TSLs for H(BeH 2 ) and Be(BeH 2 ) were evaluated in the incoherent approximation using FLASSH. Minimum critical mass estimates were performed using MC21 continuous energy Monte Carlo calculations with the BeH 2 TSLs. Researchers confirmed very low estimated critical mass for BeH 2 -moderated and Be- reflected spheres. These were the lowest critical masses NNL has studied to date. Future work includes relaxation of the incoherent approximation for Be(BeH 2 ). A small increase in critical mass is expected due to increased neutron transmission at sub-Bragg cutoff energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermal Neutron Scattering Law Benchmark and Validation at NCSU [Slides]

The presentation discusses how the NCSU graphite SDT ORELA experiment is under development as a benchmark. It discusses the testing of various ENDF/B-VII.1 and ENDF/B-VIII.0 graphite libraries that have been performed using the PROTEUS benchmark. The presentation demonstrates that the NSCU Polyethylene ENDF/B-VIII.0 TSL improves agreement with total cross section measurements. The presentation concludes by stating that the NCSU single crystal sapphire TSL library is based on realistic data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Protecting Against Potential Issues in Thermal Neutron Scattering [Slides]

This presentation touches upon the TSL community that has been growing rapidly. Additionally, this presentation mentions the more exotic materials and theories that are being implemented in TSL files. This lecture concludes on three areas of potential concern: Coherent scattering, Computational simulations, and Isotopic distribution.

07 ISOTOPE AND RADIATION SOURCES↗

IER-620 CED-3b: Experiment Execution Summary for the Pulsed-Neutron Die-Away Experiments (PNDA) with Propylene Glycol and Mobilmet 423

There is a strong need for new benchmarks to validate neutron thermal scattering laws (TSLs). Lawrence Livermore National Laboratory (LLNL) has designed a Pulsed-Neutron Die Away (PNDA) testbed for this purpose. The experiment has a deuterium-tritium (D-T) neutron generator that impinges a 10 -4 s, mono-energetic pulse of 14.1 MeV neutrons on a target sample. After the pulse, the neutron population moderates and establishes a thermal equilibrium within the sample, with a fundamental spatial mode and characteristic decay-time eigenvalue, ⍺. The ⍺ eigenvalue can be extracted from the experimental measurements of the time-dependent neutron flux coming off the surface of the sample and can then be used as an integral parameter (similar to k eff ) to validate nuclear data involved with neutron migration, thermalization, and absorption. For moderating materials and geometric configurations, the ⍺ eigenvalue is heavily dependent on thermal neutron scattering of the target material. For that reason, a PNDA experiment can have a higher sensitivity to TSLs than is commonly available with the k eff parameter in critical experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New Pulsed Neutron Die-Away Experiments in Light Water

Thermal neutron scattering laws are important data for many nuclear science and engineering applications, especially criticality safety. Recently, pulsed-neutron die-away experiments have been proposed and used as an experiment to validate thermal neutron scattering laws. These experiments involve irradiating a target moderating material with pulses of neutrons from a neutron generator. The physics of thermal scattering greatly affect how the neutron population in the target exponentially decays via absorption and leakage. Herein, we present experimental results from a new pulsed-neutron die-away experiment of light water that was performed at Lawrence Livermore National Laboratory. The experiments were done with cylindrical targets of varying dimensions to modulate the experiment’s sensitivity to thermal scattering and to absorption. We compare the measured integral parameter of the experiment to simulations with MCNP6.2 ® and to past experiments in literature. The integral parameters that were more sensitive to TSLs showed a larger bias. This validation study is known to have errors because the model of the experiment lacks key features about the detectors and neutron generator. These features will be included in the final benchmark evaluation of the experiment which will be submitted to the International Criticality Safety Benchmark Evaluation Project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Total thermal neutron cross section measurements of yttrium hydride from 0.0005 - 3 eV

Yttrium hydride serves as a neutron moderator material that enables compact, high temperature nuclear reactors. However, in order to accurately design and simulate a nuclear system relying upon yttrium hydride, the fundamental nuclear data of yttrium hydride must be well understood. Thermal neutron scattering law (TSL) evaluations represent an important aspect of nuclear data as thermal scattering can drastically alter the neutron multiplication factor of a system. Therefore, to support evaluation and validation of thermal neutron scattering for yttrium hydride, researchers at Rensselaer Polytechnic Institute (RPI) performed total thermal neutron cross section measurements for YH 1.68 and YH 1.85 over the energy range of 0.0005 - 3 eV. Further, these measurements represent the first total cross section measurements for yttrium hydride that encompass the entire thermal region. Comparisons were made against the ENDF-B/VIII.0, Zerkle & Holmes and Oak Ridge National Laboratory TSL evaluations, where generally good agreement was found.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pulsed-Neutron Die-Away Response of H 2 O Targets to a D-T Generator Pulse

Pulsed-neutron die-away (PNDA) experiments were completed at Lawrence Livermore National Laboratory (LLNL). The goal of these experiments was to provide a benchmark to validate thermal neutron scattering laws of H 2 O. The experiment was conducted with a deuterium-tritium (D-T) neutron generator producing pulses of 14.1 MeV neutrons that impinged on a moderating target. The neutrons scattered and thermalized within the target and were counted as a function of time using Helium-3 ( 3 He) detectors that surrounded the target. These data provide a time-decay profile of the neutron population from which the time eigenvalue of the experiment is calculated. The time eigenvalue quantity α represents the integral parameter of interest. This report describes the measurements for H 2 O targets. The measurements were conducted over several days beginning on October 23rd, 2023. All measurements were completed at the low-scatter facility at LLNL. The evaluation identifier is FUND-LLNL-DT-H2O-PNDA-001.

3He Detectors↗

Gamma-ray Measurements from Neutron Pulsed Die-Away Experiments

Pulsed-neutron die-away experiments are a promising experimental method that complement criticality benchmarks for nuclear data validation. The experiments have several advantages that include compatibility with non-fissile material, low benchmark uncertainties, and high sensitivity to absorption and scattering cross sections. When validating thermal neutron scattering laws, small targets are desirable for their large sensitivity to the scattering cross section and angular distribution. Unfortunately, room return or scattering from a shielding box limits the use of the very small targets needed to maximize sensitivity to thermal scattering laws. To address this problem, we propose changing the observable of the experiment from leaked thermal neutrons to γ-rays produced by (n, γ) reactions in the target. If feasible, this change allows removal of the shielding box, achieving higher sensitivity to thermal neutron scattering laws. This study focuses on replicating benchmark pulsed-neutron die-away experiments with γ-rays. We compare the integral parameters with γ-rays to those obtained with neutrons. We also discuss experimental design choices such as detector placement, shielding, and the presence of Cd. The results show the integral parameter with γ-rays is sensitive to detector location with respect to the target when Cd shielding is present. In addition, while Pb shielding around the γ-ray detectors do not seem to affect the integral parameter, the presence of Cd shielding does and adds background γ-rays to the die-away curves making it difficult to calculate the integral parameter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ab Initio Evaluation of Plutonium Dioxide $S(α,β)$ and Thermal Neutron Cross Sections

Plutonium Dioxide (PuO 2 ) is an advanced fuel-cycle nuclear fuel material for thermal and fast reactors, with a melting point at 3261.8 K and thermal conductivity above 3 Wm -1 K -1 for temperatures below 1500 K. Plutonium from spent UO 2 is reprocessed to form chemically stable mixed oxide (MOX) fuel. In contrast to metallic fuels, the low PuO 2 conductivity results in high thermal gradients between fuel center and surface, resulting in structural annealing and efficient fission product migration over burnup. Crystal binding affects the doppler broadening of epithermal resonances for nuclear fuels and scattering behavior of thermal neutrons. Currently, there is no ENDF/B Thermal Scattering Law, i.e., $S(α,β)$, evaluation for PuO 2 , only free atom cross sections for Plutonium and Oxygen, respectively, which neglect lattice contributions to total cross section. Herein, ab initio lattice dynamics (AILD) techniques are employed to calculate the phonon density of states (DOS) using spin-orbit-coupling density functional theory (DFT) to predict the PuO2 paramagnetic ground-state structure. These results highlight the evaluation of $S(α,β)$ for Plutonium and Oxygen, respectively in PuO 2 and consequential generation of thermal neutron scattering cross sections for high fidelity criticality safety analysis and reactor calculations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron thermalization in nuclear graphite: A modern story of a classic moderator

Graphite has been of great interest since the dawn of the nuclear era. In this work, we will focus on the thermal neutron scattering of two types of nuclear graphite that have different microstructures, namely, the historic PGA which has a very anisotropic medium-grained needle coke, and the new G347A which is a near-isotropic fine-grained graphite. We report the results of room temperature inelastic neutron scattering measurements for the scattering function, double differential scattering cross-section, and phonon density of states. The obtained results are discussed in conjunction with results extracted from first-principles lattice dynamics simulations of crystalline graphite, using the incoherent approximation and by also including the coherent-one phonon contribution. Excellent agreements have been found between the measured and calculated scattering functions and phonon densities of states. The inclusion of the coherent-one phonon scattering shows a significant improvement of the calculated scattering functions, double differentials, and inelastic scattering cross-sections. We also highlight the physical concerns about the current thermal neutron scattering ENDF/B-VIII of nuclear graphite library and its corresponding phonon density of states. This work aims to provide a new presentation of neutron thermalization by graphite and offers a new set of high quality experimental and computational data for consideration.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Enhancement of sub-thermal neutron flux through cold polyethylene

Total thermal neutron cross section measurements serve as the primary means of validation for thermal neutron scattering kernels, an important quantity for neutron transport calculations. In an effort to improve the quality of thermal neutron scattering kernels, researchers at Rensselaer Polytechnic Institute (RPI) designed and constructed a polyethylene based cold moderation system to enhance neutron flux below 10 meV when coupled with the Enhanced Thermal Target (ETT) at the RPI Gaerttner LINAC. The final design yielded an increase in sub-thermal neutron flux (below 10 meV) by a factor of 4.5 for a moderator temperature of 37.5 K relative to the ETT alone. A further increase to a factor of 6 is expected after a minor geometry modification and decrease in polyethylene temperature to 25 K. This novel capability will be used to conduct total thermal neutron cross section measurements from 0.0005–10 eV for different materials including moderator materials.