Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thermal Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Infrared point sources aligned with the SgrA(asterisk) non-thermal radio source

Assembled 0.7-5.0 micron observational data for two point sources approximately aligned with the compact nonthermal radio source SgrA(asterisk) in the Galactic center, thus far interpreted as being from the same object on the basis of their position and spectral continuity, are presently given alternative interpretations. While the object must be a hot star surrounded by a circumstellar dust cloud if it is a foreground star, a Galactic center position calls for an unorthodox extinction curve which suggests that the IR emission may be the Rayleigh-Jeans tail of a hot star or star cluster, or perhaps a thermal accretion disk.

Stein, W. A.↗

INGENIOUS Thermal Conductivity Measurement Source Categorization

Thermal conductivity (TC) data taken for different wells at a specified drill depth. This is an abridged version of the complete SMU heat flow database, downloaded from the SMU node of the NGDS at the beginning of INGENIOUS (approximately April 2021), and filtered to the INGENIOUS study area. This National Geothermal Data System (NGDS) project aggregates geothermal data collected and curated by the SMU Geothermal Laboratory and its partner organizations. All columns in this database are the same as the SMU database, except for 2 additions associated with this project. Repeated columns are for data correlation purposes. Column descriptions and data types are the same as previous iterations of the SMU database. The new values that are the addition are two new columns developed as part of the INGENIOUS project: INGENIOUS TC Value | INGENIOUS notes INGENIOUS notes are individual notes that were written for specific data points during the analysis process. There are not always notes associated with each input value. INGENIOUS TC Value includes 4 values: 1. Assumed Measured These are values that are assumed to be measured thermal conductivity values, either within a specific well or within the same study region. Many of these have either a published reference, a reported standard deviation, or a unique thermal conductivity value. 2. Data release - assumed measured These are values in the SMU database that are from proprietary data that were added to the SMU database and are labeled as data release for their reference. These values were searched for in person at the SMU Geothermal Laboratory as well as virtual examination of data available on the NGDS. For many of these, there are reported thermal conductivity values associated with the heat flow data in the database, but no specific table or reference to measurements in the original data release files. 3. Known measured These are values that have a reported measurement, either as an original file in the SMU data files on the NGDS or a reported table in a publication. In the rare circumstances, Maria Richards or David Blackwell confirmed measurement. Confirmation of measurement would be written in the INGENIOUS notes column. 4. Unmeasured Unmeasured values are those that are known to be unmeasured, either estimated from another report or no information given. In the SMU database, there are wells that have a heat flow but no thermal conductivity. These are categorized as unmeasured. There are also heat flow values that are stated to have estimated or generalized average thermal conductivity values for the region and rock type. Because these are known to be unmeasured, they are categorized as such. 5. Blank Blank values are either A quality or X quality. These quality values are stated in the INGENIOUS notes. These values were not going to change associated with the heat flow analysis, so these were not examined.

15 GEOTHERMAL ENERGY↗

14-MeV Neutron Generator Used as a Thermal Neutron Source

One of the most important applications of the general purpose Monte Carlo N-Particle (MCNPS and MCNPX) codes is neutron shielding design. We employed this method to simulate the shield of a 14-MeV neutron generator used as a thermal neutron source providing an external thermal neutron beam for testing large area neutron detectors developed for diffraction studies in biology and also useful for national security applications. Nuclear reactors have been the main sources of neutrons used for scientific applications. In the past decade, however, a large number of reactors have been shut down, and the importance of other, smaller devices capable of providing neutrons for research has increased. At Brookhaven National Laboratory a moderated Am-Be neutron source with shielding is used for neutron detector testing. This source is relatively weak, but provides a constant flux of neutrons, even when not in use. The use of a 14 MeV energized neutron generator, with an order of magnitude higher neutron flux has been considered to replace the Am-Be source, but the higher fast neutron yield requires a more careful design of moderator and shielding. In the present paper we describe a proposed shielding configuration based on Monte Carlo calculations, and provide calculated neutron flux and dose distributions. We simulated the neutron flux distribution of our existing Am-Be source surrounded by a paraffin thermalizer cylinder (radius of 17.8 cm), 0.8 mm cadmium, and borated polyethylene as biological shield. The thermal neutrons are available through a large opening through the polyethylene and cadmium. The geometrical model for the MCNPS and MCNPX2 simulations is shown in Fig. 1. We simulated the Am-Be source neutron energy distribution as a point source having an energy distribution of four discrete lines at 3.0 (37%), 5.0 (35%), 8.0 (20%) and 11.0 (8%) MeV energies. The estimated source strength based on the original specifications is 6.6 {center_dot} 10{sup 6} neutrons/sec. The simulation accurately predicts the measured thermal neutron flux at the collimator (Figure 2), thus providing validation for this method. Using MCNPX we simulated the neutron and photon dose distribution and also obtained a good agreement with the measured values. Having established a validated framework for the shield calculation we then scaled up the Am-Be arrangement to simulate the shielding required for the higher neutron energy and flux of the neutron generator (-10{sup 8} neutrodsec at 14 MeV). Given the physical dimensions of the generator we have chosen a cylindrical geometry, where the generator tube is placed vertically into a cylindrical thermalizer (25 cm paraffin) from above. The thermalizer is surrounded by 0.8 mm cadmium, and a cylindrical borated polyethylene shield. A cylindrical opening (radius of 7.6 cm) serves to direct the neutrons out towards the experimental area (on the right side). The initial model is shown in figure 3. The first goal of the calculations was to establish the minimal required radius of the biological shield. For this purpose we performed MCNPX neutron and photon dose distribution calculations by tallying the absorbed dose on a 200 x 200 cm mesh in the vertical center plane superimposed over the geometry. Figure 4. displays the neutron dose distribution along the central horizontal (X) axis. As observed from the figure, a shielding radius of -80 cm is sufficient to obtain a dose level of < -4 mrem/hour outside the shield (except from the open neutron channel on the right). In the next step we studied the optimization of the thickness of the paraffin thermalizer by increasing the depth of the neutron exit channel into the paraffin cylinder. It was found, that the thermal flux greatly increases if we have thinner paraffin layer, an optimal value being about 5 cm thickness. But as a drawback the flux of fast neutrons also increased. A thicker thermalizer layer, in fact, acts as shielding. A slightly off centered, tangential placement of the neutron channel provides a solution which maximizes the thermal flux to fast neutron yield. Figure 5. and 6. display the final results, where we included an outside biological shield (20 cm thickness) providing a shielded experimental area. There is a 10-100 n/cm{sup 2}sec flux near the neutron beam exit, and outside the shield the neutron dose is below the radiation area limit (-5 mrem/hour).

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

THE BURSTY NATURE OF SOLAR FLARE X-RAY EMISSION. II. THE NEUPERT EFFECT

We carry out a novel statistical test of the Neupert effect based on multifractal spectra. The multifractal spectrum is the number distribution of the strengths (i.e., the Hölder exponents) of bursts in a signal. This is tested on simulations and carried out on RHESSI X-ray data from a well observed GOES X4.8 magnitude flare. The multifractal spectra is ideally suited to quantifying the relative smooth and bursty signals typically found in (thermal) soft X-ray and (non-thermal) hard X-ray data of solar flares. We show that light curves from all energies between 3 keV and 25 keV are statistically similar, suggesting that all these signals are dominated by the same (presumably thermal) emission. Emission lying between 25 keV and 100 keV probably contains some contribution from both thermal and non-thermal sources. The multifractal spectrum of a signal and that of its (cumulative) temporal integration are statistically similar (i.e., low residuals upon subtraction), but shifted by one in the peak Hölder exponent. We find the pairs of 3-6 keV and 100-300 keV emissions, the 6-12 keV and 100-300 keV emissions and the 12-25 keV and 100-300 keV emissions are all consistent with the Neupert effect. The best agreement with the Neupert effect is between the 12-25 keV and 100-300 keV pair, although possibly with some secondary source of thermal emission present.

79 ASTRONOMY AND ASTROPHYSICS↗

Quasi-periodic pulsations with varying period in multi-wavelength observations of an X-class flare

This work presents an interesting phenomenon of the period variation in quasi-periodic pulsations (QPPs) observed during the impulsive phase of a coronal mass ejection-related X1.1 class flare on 2012 July 6. The period of QPPs was changed from 21 s at soft X-rays (SXR) to 22-23 s at microwaves, to ∼24 s at extreme ultraviolet emissions (EUV), and to 27-32 s at metric-decimetric waves. The microwave, EUV, and SXR QPPs, emitted from flare loops of different heights, were oscillating in phase. Fast kink mode oscillations were proposed to be the modulation mechanism, which may exist in a wide region in the solar atmosphere from the chromosphere to the upper corona or even to the interplanetary space. Changed parameters of flare loops through the solar atmosphere could result in the varying period of QPPs at different wavelengths. The first appearing microwave QPPs and quasi-periodic metric-decimetric type III bursts were generated by energetic electrons. This may imply that particle acceleration or magnetic reconnection were located between these two non-thermal emission sources. Thermal QPPs (in SXR and EUV emissions) occurred later than the nonthermal ones, which would suggest a some time for plasma heating or energy dissipation in flare loops during burst processes. At the beginning of flare, a sudden collapse and expansion of two separated flare loop structures occurred simultaneously with the multi-wavelength QPPs. An implosion in the corona, including both collapse and expansion of flare loops, could be a trigger of loop oscillations in a very large region in the solar atmosphere.

79 ASTRONOMY AND ASTROPHYSICS↗

General Purpose Fortran Program for Discrete-Ordinate-Method Radiative Transfer in Scattering and Emitting Layered Media: An Update of DISORT

This update reports a state-of-the-art discrete ordinate algorithm for monochromatic unpolarized radiative transfer in non-isothermal, vertically inhomogeneous, but horizontally homogeneous media. The physical processes included are Planckian thermal emission, scattering with arbitrary phase function, absorption, and surface bidirectional reflection. The system may be driven by parallel or isotropic diffuse radiation incident at the top boundary, as well as by internal thermal sources and thermal emission from the boundaries. Radiances, fluxes, and mean intensities are returned at user-specified angles and levels. DISORT has enjoyed considerable popularity in the atmospheric science and other communities since its introduction in 1988. Several new DISORT features are described in this update: intensity correction algorithms designed to compensate for the 8-M forward-peak scaling and obtain accurate intensities even in low orders of approximation; a more general surface bidirectional reflection option; and an exponential-linear approximation of the Planck function allowing more accurate solutions in the presence of large temperature gradients. DISORT has been designed to be an exemplar of good scientific software as well as a program of intrinsic utility. An extraordinary effort has been made to make it numerically well-conditioned, error-resistant, and user-friendly, and to take advantage of robust existing software tools. A thorough test suite is provided to verify the program both against published results, and for consistency where there are no published results. This careful attention to software design has been just as important in DISORT's popularity as its powerful algorithmic content.

Tsay, Si-Chee↗

14-MeV Neutron Generator Used as a Thermal Neutron Source

One of the most important applications of the general purpose Monte Carlo N-Particle (MCNP5 and MCNPX) codes is neutron shielding design. We employed this method to simulate the shielding of a 14-MeV neutron generator used as a thermal neutron source providing an external thermal neutron beam for testing large area neutron detectors developed for diffraction studies in biology and also useful for national security applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cold-atom gravimetry with a Bose-Einstein condensate

We present a cold-atom gravimeter operating with a sample of Bose-condensed {sup 87}Rb atoms. Using a Mach-Zehnder configuration with the two arms separated by a two-photon Bragg transition, we observe interference fringes with a visibility of (83{+-}6)% at T=3 ms. We exploit large momentum transfer (LMT) beam splitting to increase the enclosed space-time area of the interferometer using higher-order Bragg transitions and Bloch oscillations. We also compare fringes from condensed and thermal sources and observe a reduced visibility of (58{+-}4)% for the thermal source. We suspect the loss in visibility is caused partly by wave-front aberrations, to which the thermal source is more susceptible due to its larger transverse momentum spread. Finally, we discuss briefly the potential advantages of using a coherent atomic source for LMT, and we present a simple mean-field model to demonstrate that with currently available experimental parameters, interaction-induced dephasing will not limit the sensitivity of inertial measurements using freely falling, coherent atomic sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Demonstration of non-destructive and isotope-sensitive material analysis using a short-pulsed laser-driven epi-thermal neutron source

Neutrons are a valuable tool for non-destructive material investigation as their interaction cross sections with matter are isotope sensitive and can be used complementary to x-rays. So far, most neutron applications have been limited to large-scale facilities such as nuclear research reactors, spallation sources, and accelerator-driven neutron sources. Here we show the design and optimization of a laser-driven neutron source in the epi-thermal and thermal energy range, which is used for non-invasive material analysis. Neutron resonance spectroscopy, neutron radiography, and neutron resonance imaging with moderated neutrons are demonstrated for investigating samples in terms of isotope composition and thickness. The experimental results encourage applications in non-destructive and isotope-sensitive material analysis and pave the way for compact laser-driven neutron sources with high application potential.

36 MATERIALS SCIENCE↗

Radiological Characterization of Selected Thermal Centres Based on Indoor Radon Dosimetry - 17507

In countries with long historical tradition in thermal water therapy and with several mineral-medicinal thermal sources, workplaces within thermal centers may be a source of radon exposure which may be intensified if these are located in regions of high level of natural radiation. According to the EU Directive 96/29/Euratom (repealed by the Directive 2013/59/EURATOM) each Member State shall identify, by means of survey or any other adequate mean, the work activities where a significant increase in the exposure from natural radiation sources may occur, including thermal centers where the exposure to thoron/radon daughters or gamma radiation may occur. The purpose of this work was to perform a radiological characterization of selected thermal centers based on indoor dosimetry. The effective doses received by workers due to radon inhalation were estimated and gamma dose rates were measured through continuous periods. The radon risk for indoor exposure was assessed on a probabilistic basis both on thermal centers and workers' dwellings. Radon levels within the thermal centers ranged from 73 to 4335 Bq/m{sup 3} and the values within the workers dwellings are of the same order of magnitude, 68-4051 Bq/m{sup 3}. Approximately 66 % of indoor radon concentration values are above the maximum EU reference (300 Bq/m{sup 3}) and 94 % of the effective dose is higher than 1 mSv/year. In some situations, radon levels at residential environments are much higher than at workplaces and effective doses are higher than 6 mSv/year, both at residential and work environments. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Quantum optimality of photon counting for temperature measurement of thermal astronomical sources

Using the quantum Cramér–Rao bound from quantum estimation theory, we derive a fundamental quantum limit on the sensitivity of a temperature measurement of a thermal astronomical source. This limit is expressed in terms of the source temperature T{sub s}, input spectral bandwidth Δν, and measurement duration T, subject to a long measurement time assumption TΔν≫1. It is valid for any measurement procedure that yields an unbiased estimate of the source temperature. The limit agrees with the sensitivity of direct detection or photon counting, and also with that of the ideal radiometer in the regime kT{sub s}/hν{sub 0}≫1 for which the Rayleigh–Jeans approximation is valid, where ν{sub 0} is the center frequency at which the radiometer operates. While valid across the electromagnetic spectrum, the limit is especially relevant for radio astronomy in this regime, since it implies that no ingenious design or technological improvement can beat an ideal radiometer for temperature measurement. In this connection, our result refutes the recent claim of a radio astronomy technique with much-improved sensitivity over the radiometer.

79 ASTRONOMY AND ASTROPHYSICS↗

Unsteady heat transfer in turbine blade ducts: Focus on combustor sources

Thermal waves generated by either turbine rotor blades cutting through nonuniform combustor temperature fields or unsteady burning could lead to thermal fatigue cracking in the blades. To determine the magnitude of the thermal oscillation in blades with complex shapes and material compositions, a finite element Galerkin formulation has been developed to study combustor generated thermal wave propagation in a model two-dimensional duct with a uniform plug flow profile. The reflection and transmission of the thermal waves at the entrance and exit boundaries are determined by coupling the finite element solutions at the entrance and exit to the eigenfunctions of an infinitely long adiabatic duct. Example solutions are presented. In general, thermal wave propagation from an air passage into a metallic blade wall is small and not a problem. However, if a thermal barrier coating is applied to a metallic surface under conditions of a high heat transfer, a good impedance match is obtained and a significant portion of the thermal wave can pass into the blade material.

Baumeister, Kenneth J.↗

Unsteady heat transfer in turbine blade ducts - Focus on combustor sources

Thermal waves generated by either turbine rotor blades cutting through nonuniform combustor temperature fields or unsteady burning could lead to thermal fatigue cracking in the blades. To determine the magnitude of the thermal oscillation in blades with complex shapes and material compositions, a finite element Galerkin formulation has been developed to study combustor generated thermal wave propagation in a model two-dimensional duct with a uniform plug flow profile. The reflection and transmission of the thermal waves at the entrance and exit boundaries are determined by coupling the finite element solutions at the entrance and exit to the eigenfunctions of an infinitely long adiabatic duct. Example solutions are presented. In general, thermal wave propagation from an air passage into a metallic blade wall is small and not a problem. However, if a thermal barrier coating is applied to a metallic surface under conditions of a high heat transfer, a good impedance match is obtained and a significant portion of the thermal wave can pass into the blade material.

Baumeister, K. J.↗

Modeling Images and Spectra of a Solar Flare Observed by RHESSI on 20 February 2002

We have analyzed a C7.5 limb flare observed by RHESSI on 20 February 2002. The RHESSI images appear to show two footpoints and a loop-top source. Our goal was to determine if the data are consistent with a simple steady-state model in which high-energy electrons are continuously injected at the top of a semicircular flare loop. A comparison of the RHESSI images with simulated images from the model has made it possible for us to identify spurious sources and fluxes in the RHESSI images. We find the RHESSI results are in many aspects consistent with the model if a thermal source is included between the loop footpoints, but there is a problem with the spectral index of the loop-top source. The thermal source between the footpoints is likely to be a low-lying loop interacting with the northern footpoint of a higher loop containing the loop-top source.

Sui, Linhui↗

Thermoelectric power generator for variable thermal power source

Traditional power generation systems using thermoelectric power generators are designed to operate most efficiently for a single operating condition. The present invention provides a power generation system in which the characteristics of the thermoelectrics, the flow of the thermal power, and the operational characteristics of the power generator are monitored and controlled such that higher operation efficiencies and/or higher output powers can be maintained with variably thermal power input. Such a system is particularly beneficial in variable thermal power source systems, such as recovering power from the waste heat generated in the exhaust of combustion engines.

30 DIRECT ENERGY CONVERSION↗

Passive state preparation in the Gaussian-modulated coherent-states quantum key distribution

In the Gaussian-modulated coherent-states (GMCS) quantum key distribution (QKD) protocol, Alice prepares quantum states actively: For each transmission, Alice generates a pair of Gaussian-distributed random numbers, encodes them on a weak coherent pulse using optical amplitude and phase modulators, and then transmits the Gaussian-modulated weak coherent pulse to Bob. Here we propose a passive state preparation scheme using a thermal source. In our scheme, Alice splits the output of a thermal source into two spatial modes using a beam splitter. She measures one mode locally using conjugate optical homodyne detectors, and transmits the other mode to Bob after applying appropriate optical attenuation. Under normal conditions, Alice's measurement results are correlated to Bob's, and they can work out a secure key, as in the active state preparation scheme. Given the initial thermal state generated by the source is strong enough, this scheme can tolerate high detector noise at Alice's side. Furthermore, the output of the source does not need to be single mode, since an optical homodyne detector can selectively measure a single mode determined by the local oscillator. Preliminary experimental results suggest that the proposed scheme could be implemented using an off-the-shelf amplified spontaneous emission source.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Search for thermal X-ray line emission from the Crab Nebula

Observations of the Crab Nebula from 1.85 to 8 keV obtained with the large-area graphite crystal spectrometer on OSO-8 show a smooth featureless continuum with an absence of X-ray emission lines from highly ionized Si and S. Upper limits on the line emission are used to derive an upper limit to the emission measure for a thermal source associated with the Crab Nebula. Existing evidence for an extended thermal source is discussed, and it is shown that the evidence is not contradicted by the upper limits set with the spectrometer data.

Kestenbaum, H. L.↗

Numerical results for the thermal scattering functions

A recent formulation in radiative transfer defined the thermal scattering functions that characterize radiative transfer from a general plane-parallel finite medium driven solely by an internal distribution of thermal sources. Exiting diffuse intensities are expressed as space convolutions of the thermal scattering functions with any thermal source distribution. A parametric study is presented to obtain the basic structure of these scattering functions. The independent variables of these azimuthally independent functions are the direction cosine and source location, while the parameters are the single-scattering albedo, total optical depth, and the asymmetry factor in the Henyey-Greenstein phase function. The basic functional trends are discussed by using various parametric plots, and selected results are given to allow numerical checks. The computational method is invariant imbedding.

Cogley, A. C.↗