Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thermal inertia”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Optimizing Grid Regulation With Gravity Storage Systems: A Comparative Analysis With Different Motor Inertias

The integration of renewable energy sources into power grids necessitates solutions for grid support and stability during fluctuations in electricity generation and demand. Gravity energy storage systems (GESS) are emerging as a promising technology for managing the balance between energy supply and demand. However, their capacity to optimize energy flow and offer voltage and frequency regulation amid imbalances in generation and demand is less reported. This paper investigates the control of GESS for optimizing energy flow during voltage and frequency regulation. The study evaluates the regulation capabilities of GESS with different motor inertias during a Texas grid event: one with a high-speed, low-inertia motor and another with a low-speed, high-inertia motor. Results indicate that both GESS scenarios provide fast frequency response by converting potential energy into kinetic energy and vice versa, with a response time of 1.5 s from the frequency variation. This aligns with grid requirements for primary frequency response from traditional synchronous generators and motors with large inertia. Furthermore, a GESS based on a high-inertia motor may be able to operate over a broader range of frequency variations, whereas a low-inertia system may be limited by thermal constraints of the motor.

frequency regulation↗

Optimizing Grid Regulation With Gravity Storage Systems: A Comparative Analysis With Different Motor Inertias: Preprint

The integration of renewable energy sources into power grids necessitates solutions for grid support and stability during fluctuations in electricity generation and demand. Gravity energy storage systems (GESS) are emerging as a promising technology for managing the balance between the energy supply and demand. However, their capacity to optimize energy flow and offer voltage and frequency regulation amid generation-demand imbalances is less reported. This paper investigates the control of GESS for optimizing energy flow during voltage and frequency regulation. The study evaluates the regulation capabilities of GESS with different motor inertias during a Texas grid event: one with a high-speed, low-inertia motor and another with a low-speed, high-inertia motor. Results indicate that both GESS systems provide fast frequency response by converting potential energy into kinetic energy and vice versa, with a response time of 1.5 seconds from the frequency variation. This aligns with grid requirements for primary frequency response from traditional synchronous generators and motors with large inertia. Furthermore, a GESS with a high-inertia motor may be able operate over a broader range of frequency variations whereas a low-inertia system may be limited by thermal constraints of the motor.

frequency regulation↗

Optimizing Grid Regulation with Gravity Energy Storage Systems: A Comparative Analysis with Different Motor Inertias

The integration of renewable energy sources into power grids necessitates solutions for grid support and stability during fluctuations in electricity generation and demand. Gravity energy storage systems (GESS) are emerging as a promising technology for managing the balance between energy supply and demand. However, their capacity to optimize energy flow and offer voltage and frequency regulation amid imbalances in generation and demand is less reported. This paper investigates the control of GESS for optimizing energy flow during voltage and frequency regulation. The study evaluates the regulation capabilities of GESS with different motor inertias during a Texas grid event: one with a high-speed, low-inertia motor and another with a low-speed, high-inertia motor. Results indicate that both GESS scenarios provide fast frequency response by converting potential energy into kinetic energy and vice versa, with a response time of 1.5 s from the frequency variation. This aligns with grid requirements for primary frequency response from traditional synchronous generators and motors with large inertia. Furthermore, a GESS based on a highinertia motor may be able to operate over a broader range of frequency variations, whereas a low-inertia system may be limited by thermal constraints of the motor.

ENERGY STORAGE,POWER TRANSMISSION AND DISTRIBUTION↗

CSP Plant Optimization Study for the California Power Market (“CalCSP”) (Final Technical Report)

Concentrating Solar Power (CSP) with thermal energy storage offers a unique and strategic opportunity to support California’s clean energy transition. Unlike photovoltaic (PV) systems, CSP with thermal storage can generate electricity after sunset and during periods of high demand, making it a valuable complement to intermittent renewable resources. CSP also provides synchronous, inertia-contributing generation, long-duration storage, and flexible dispatch—capabilities increasingly important as thermal plants retire. This report summarizes the findings of the CSP Plant Optimization Study for the California Power Market or “CalCSP study,” which evaluated the technical, economic, environmental, and policy factors that influence the deployment of CSP technologies in California. The CalCSP study was conducted to assess how CSP can contribute to California’s long-term decarbonization goals while enhancing grid reliability, supporting local economic development, and making efficient use of land and transmission resources. It draws on detailed modeling of CSP performance and costs, site suitability analysis, policy reviews, and stakeholder engagement across utilities, regulators, developers, and community organizations. The analysis focuses on mature molten-salt tower technology and incorporates lessons learned from the global CSP fleet, distinguishing today’s CSP from earlier first-of-a-kind projects in the U.S. The findings support a more prominent role for CSP in California’s evolving clean energy landscape. With strategic planning, targeted policy support, and continued cost improvements, CSP can complement PV and batteries to deliver reliable, around-the-clock clean electricity—especially in areas with high solar resource and constrained grid capacity.

14 SOLAR ENERGY↗

Low-temperature Leidenfrost-like jumping of sessile droplets on microstructured surfaces

The Leidenfrost effect—the levitation and hovering of liquid droplets on hot solid surfaces—generally requires a sufficiently high substrate temperature to activate liquid vaporization. Here, in this paper, we report the modulation of Leidenfrost-like jumping of sessile water microdroplets on micropillared surfaces at a relatively low temperature. Compared to traditional Leidenfrost effect occurring above 230 °C, the fin-array-like micropillars enable water microdroplets to levitate and jump off the surface within milliseconds at a temperature of 130 °C by triggering the inertia-controlled growth of individual vapour bubbles at the droplet base. We demonstrate that droplet jumping, resulting from momentum interactions between the expanding vapour bubble and the droplet, can be modulated by tailoring of the thermal boundary layer thickness through pillar height. This enables regulation of the bubble expansion between the inertia-controlled mode and the heat-transfer-limited mode. The two bubble-growth modes give rise to distinct droplet jumping behaviours characterized by constant velocity and constant energy regimes, respectively. This heating strategy allows the straightforward purging of wetting liquid droplets on rough or structured surfaces in a controlled manner, with potential applications including the rapid removal of fouling media, even when located in surface cavities.

42 ENGINEERING↗

Facets of hydro power and future trends in a Nordic Context

Hydropower technologies bolster high penetration of variable renewable energies (VREs) in the net zero emissions scenarios. Nevertheless, there are various challenges to meeting the ambitious goal, such as stability, reliability, resiliency, security, lack of reactive power, voltage support and inertia, large-scale storage deployment and coordination, interconnectedness, demand-side response, higher thermal cycles with increased start/stops, and inadequate Levelized Cost of Energy (LCOE) for system-wise VRE integration and profitability. This survey conducts a bottom-up analysis to unveil the opportunities to utilize hydropower facilities and disentangle the nested problem for intertwining design features, control algorithms, operation, optimization approaches, incentives, services, and market mechanisms using a three-pillar framework perspective: grid owners, power producers, and machine designers. The survey identified emerging trends in real-time and capacity markets, flexible power systems, and enhanced grid capabilities, including advanced voltage support and updated grid codes. These developments present significant opportunities for hydropower, such as achieving super-flexibility through hybridization, expanded reactive power capabilities, and advanced operational modes like a synchronous condenser and power adequator functionalities. These opportunities require novel design philosophies — including new winding, stator, and rotor configurations, optimized ventilation, and active cooling systems — to enhance performance under stressed grid and climate conditions. Finally, integrating climate and energy models for multi-basin optimization with finer spatial and temporal granularity enhances the planning accuracy for water management of hydropower while addressing environmental challenges. The review delivers helpful prospective suggestions and tools that would serve researchers, power engineers, and stakeholders in making decisions about hydropower technologies and services in 2050 and beyond.

13 HYDRO ENERGY↗

Technology Strategy Assessment: Findings from Storage Innovations 2030 Thermal Energy Storage

The concept of thermal energy storage (TES) can be traced back to early 19th century, with the invention of the ice box to prevent butter from melting. Modern TES development began with building heating and cooling and concentrated solar thermal technologies for power generation in the early 1900s and late 1970s, respectively. TES systems provide many advantages compared with other long-duration energy storage (LDES) technologies, which include low costs, long operational lives, high energy density, synchronous power generation capability with inertia that inherently stabilizes the grid, and the ability to output both heat and electricity. TES Use Cases TES technologies can couple with most renewable energy systems, including wind, photovoltaic, and concentrated solar thermal energy, and can be used for heat-to-heat, heat-to-electricity, electricity-to-heat, and electricity-to-electricity (bidirectional electricity) applications. The three types of TES that have heat as an input or output are grouped together for the purposes of this report. Retrofitting retired thermal power plants can be a potential cost-effective option for TES with electricity output because they both use a similar thermal-to-electricity type of conversion. Additionally, TES can directly serve heat demand for buildings and industrial processes, displacing fossil fuels to achieve broad decarbonization. Bidirectional Electricity Figure 1 shows a bidirectional electricity TES (ETES) architecture that is emerging as a prime technology for LDES at a grid scale. The ETES technology can utilize existing TES technology infrastructures, has no geological limitations (such as mountains and water for pumped storage hydro, underground natural caverns for compressed-air energy storage, etc.), and is capable of deployment anywhere in the United States and the world for broad uses. Particularly, ETES technology can be placed at retired fossil-fueled thermal power plants to reuse decommissioned assets, protect job security in associated communities, and provide resilient and high-inertia (i.e., spinning) power to the grid. Heat Input and Output There also are many ways to integrate TES within heat-to-electricity, heat-to-heat, and electricity-to-heat applications, such as those used in concentrating solar power (CSP), buildings, district heating, and industry process heat applications. These categories can be further classified for low- and high-temperature applications. High-temperature thermal energy storage (HTTES) heat-to-electricity TES applications are currently associated with CSP deployments for power generation. TES with CSP has been deployed in the Southwestern United States with rich solar resources and has proved its value to the electric grid. Electricity-to-heat and heat-to-heat HTTES applications present great potential for decarbonizing energy-intensive industrial process heat applications [8, 9], such as iron ore processing, iron smelting, cement production, glass manufacturing, mineral processing, and chemical production. Some industrial processes require process heat at temperatures > 1,400°C, so HTTES can be utilized to reduce fuel consumption in those processes through fuel, oxidizer, and process material pre-heating. Thermal energy storage for augmenting existing industrial process heat applications makes a much more attractive economic case because the energy penalty due to thermal-to-electric conversion is eliminated. Co-located applications of power production and heat also can add to the value stacking of integrating utility-scale TES; however, these scenarios are very case specific and not practically possible in many cases. These constraints are primarily attributed to the existing infrastructure being designed, developed, and constructed for many decades around the most economically feasible technologies, such as electricity and a selection of fossil fuels for heat input. Low-temperature TES can be utilized for building and district heating and cooling, as well as some process heat applications in electricity-to-heat and heat-to-heat configurations. Lower temperature TES (LTTES) can be added to heat pump equipment (electric input), either directly interacting with the refrigerant in the condenser or evaporator, or through a secondary heat transfer fluid. It also can be integrated in the building envelope or within the ducts of the heating, ventilation, and air conditioning (HVAC) system. Cost-effective integration of TES into buildings adds significant cost, and it is one of the key barriers preventing the commercialization and deployment of TES. The optimal strategy for integrating TES with buildings has yet to be determined for various applications of TES. Nevertheless, thermal storage materials are far less costly per unit of energy stored than electricity storage materials. This means that thermal storage has the potential to reduce the cost to society of energy storage.

25 ENERGY STORAGE↗

Expansion dynamics of femtosecond laser-induced plasmas: Influence of thermophysical plasma properties

This study investigates the expansion dynamics of femtosecond laser-induced plasmas, emphasizing the impact of plasma thermophysical properties and ambient gas composition. Through shadowgraphy experiments and multiphase computational fluid dynamics (CFD) simulations, the influence of parameters such as heat capacity, molecular weight, and thermal conductivity on plume morphology, shockwave evolution, and energy dissipation mechanisms is examined. A mixture multiphase model is implemented to capture the interaction between the plasma and the surrounding gas. Simulation results reveal that plasma expansion is strongly inertia-driven. Results show that differences in plasma properties and ambient conditions affect the shape and temperature distribution of the expanding plume. The early-stage dynamics are primarily dictated by pressure forces, whereas thermal and viscous effects play a growing role in the plume's behavior during later stages of expansion. The CFD findings show the necessity of accurate initial condition characterization, including crater geometry and plasma pressure and temperature, for reliable modeling of plasma evolution in laser ablation processes.

CFD modeling↗

Generation of Fragment Angular Momentum in Fission

A recent analysis of experimental data [J. Wilson et al., Nature (London) 590, 566 (2021)] found that the angular momenta of nuclear fission fragments are uncorrelated. Based on this finding, the authors concluded that the spins are therefore determined only after scission has occurred. We show here that the nucleon-exchange mechanism, as implemented in the well-established event-by-event fission model freya, while agitating collective rotational modes in which the two spins are highly correlated, nevertheless leads to fragment spins that are largely uncorrelated. We find that this counterexample invalidates the conclusion in [J. Wilson et al.] that uncorrelated spins must necessarily have been generated after scission (a potentious conclusion that would rule out all models that generate the fragment spins prior to scission). Furthermore, it was reported [J. Wilson et al.] that the mass dependence of the average fragment spin has a sawtooth structure. We demonstrate that such a behavior naturally emerges when shell and deformation effects are included in the moments of inertia of the fragments at scission.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Frequency Control and Dynamics (Part 1) [Slides]

This presentation provides an introductory overview of system dynamics and frequency control in electric power systems, with a focus on concepts relevant to small and interconnected grids such as those in Malawi. It explains foundational principles of AC system frequency, the relationship between generation-demand balance and frequency deviations, and the operational limits of generators and end-use equipment. The deck discusses frequency stability within broader system stability classifications and illustrates how inertia and turbine-governor dynamics shape system response to disturbances. It then outlines the tiered approach to frequency control - primary, secondary, and tertiary - detailing the roles, characteristics, timescales, and response mechanisms of each. Special emphasis is placed on hydro and thermal unit behavior, area control error (ACE), automatic generation control (AGC), and the operational implications of interconnecting small systems with larger grids. The material was developed to support Malawi's electricity sector and the establishment of the Southern Africa Battery Energy Storage Center of Excellence (SABESS CoE).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frequency Control and Dynamics (Part 2) [Slides]

This presentation provides an introductory overview of system dynamics and frequency control in electric power systems, with a focus on concepts relevant to small and interconnected grids such as those in Malawi. It explains foundational principles of AC system frequency, the relationship between generation-demand balance and frequency deviations, and the operational limits of generators and end-use equipment. The deck discusses frequency stability within broader system stability classifications and illustrates how inertia and turbine-governor dynamics shape system response to disturbances. It then outlines the tiered approach to frequency control - primary, secondary, and tertiary - detailing the roles, characteristics, timescales, and response mechanisms of each. Special emphasis is placed on hydro and thermal unit behavior, area control error (ACE), automatic generation control (AGC), and the operational implications of interconnecting small systems with larger grids. The material was developed to support Malawi's electricity sector and the establishment of the Southern Africa Battery Energy Storage Center of Excellence (SABESS CoE).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fast, Controllable, and Modular Solid-State Circuit Breaker Design for Battery Management Systems

Electric power grid is experiencing a growing number of distributed and inertia-free generation resources. To facilitate the growing generation and load demands, and ensure stable operation, energy storage systems, especially behind-themeter-storage (BTMS), have emerged as a potential candidate. BTMS plays a vital role in the grid storage sector and supports high power charging for EVs. However, the potential of thermal runaway and associated safety concerns in the batteries can hamper their widespread adoption. In this work, we provide a solution for a fast and controllable discharge of a cell that was identified as a stressful/faulty, in the battery pack, and fast circuit breaking leveraging the Solid-State Circuit Breaker (SSCB) technology which provides active control over the cell connection as opposed to conventional passive solutions. Testing on the simulation platform successfully validated the concept, demonstrating its efficacy. Controlled discharge testing with 20Ah LiFePO4 Lithium Iron Phosphate (LFP) cells from 1C-10C current rate on the hardware prototype corroborated simulation results, demonstrating design feasibility and providing essential data for its performance and thermal characteristics, while also revealing limitations that inform areas for further optimization.

33 ADVANCED PROPULSION SYSTEMS↗

A Unified Scaling Framework for Comparative Analysis of Major Electrical Machine Topologies

This paper presents a unified framework for comparing major electrical machine topologies under identical output and thermal constraints, with emphasis on supply-chain-aware selection among rare-earth-intensive, reduced-rare-earth, and rare-earth-free solutions. Using power factor and air-gap flux density as the principal descriptors, the framework links topology choice to relative size, copper demand, magnet dependence, cost sensitivity, and inertia. To support robust early-stage screening, the deterministic scaling model is combined with uncertainty representation, Monte Carlo scenario propagation, and hesitationaware ranking. The results show that rare-earth-rich machines remain compact and dense, whereas reduced-rare-earth and rare-earth-free alternatives become more attractive under specific material-risk and cost scenarios.

Kumar, Praveen [ORNL] (ORCID:0000000291877857)↗

Challenge Problem 1: Preliminary Results of the Direct Numerical Simulation of Transient Flows

This report presents the first direct numerical simulations (DNS) of transient mixed convection in an idealized downcomer-like channel (Challenge Problem 1, Phase II). Using the GPU-accelerated NekRS solver, we modeled a sudden decay in driving pressure, mimicking loss-of-flow events, and tracked the resulting evolution of Reynolds number, boundary-layer structure, turbulence statistics, and heat-transfer metrics. Key findings include the systematic thickening and eventual asymmetry of velocity and thermal boundary layers under buoyant deceleration; minimal “memory” lag in Reynolds shear stress and TKE profiles when sampled at matching Re, yet clear shifts of peak locations toward the cooled wall; overshoots in transient eddy-viscosity and eddy-diffusivity (and corresponding sub-unity turbulent Prandtl numbers) on the cooled side; and a pronounced transient Nusselt-number enhancement driven by wall-temperature inertia and residual eddy mixing. These effects combined to offer a temporary cooling margin above steady-state predictions during reactor LOF transients. Future work will extend this work to a more complex “Case II” geometry (90° turn + lower plenum) and generate multi-Re/Pr datasets for data-driven turbulence closures.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SIW21-95: Hybridizing Synchronous Condensers with Grid-Forming Battery Energy Storage Systems

One of the main challenges associated with deployment of high shares of inverter-based resources (IBRs) in power grid is not only reduced system inertia but also degrading system strength that may cause severe stability impacts. A minimum level of system strength is needed for the power system to remain stable under normal conditions and to return to a steady state condition following a system disturbance. Significant system strength reduction is expected in almost all planned areas for solar and wind generation deployment. Synchronous condensers (SC) have been considered as one main technology to address the system strength issues for the areas with high levels of IBRs. SCs can help improving reliability and resiliency of power system but they do not provide the full range of services needed by power systems for reliable and economic integration of high shares of inverter-coupled variable generation such as PV generation. Services related to active power controls cannot be provided by SCs due to lack of prime mover. Even for provision of reactive power SCs have certain constraints based on their thermal and stability limits. NREL has been conducting research on a hybridized concept that combines SCs with grid forming (GFM) battery energy storage systems (BESS). This super flexible AC transmission system (SuperFACTS) that combines these two technologies in a single plant under the same controller offers a unique scalable set of services to the power system at all levels (transmission, sub-transmission, distribution, islands and isolated microgrids). Depending on use cases, SuperFACTS can be controlled to provide fully dispatchable and flexible operation using energy storage component, provide a full range of existing and future ancillary and reliability services to the grid (similar or better than conventional sources), maintain adequate levels of grid strength and inertia, and provide fault current for proper operation of protection systems. Therefore, this economic and easy to commercialize solution has potential for significant impacts on certain segments of global energy sector. All types of gird services (market based, reliability and resiliency) can be provided by SuperFACTS plants. GFM BESS can act as a self-black start source for each SuperFACTS module, which in turn can act a black start resource for co-located PV and wind power plants, segments of transmission and distribution networks, for conventional power plants, etc. The issue of in-rush currents during black start is addressed by overcurrent capability of SCs. In this paper we describe the results of modeling for SuperFACTS concept.

grid forming↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗

Explicit simulation of the Brownian rotation of arbitrary shaped aerosol particles using quaternions

The shape of an aerosol particle strongly influences its mass and momentum transfer cross-sections, charging properties, and other physical properties. Here, we present an explicit time-stepping procedure to simulate the rotational Brownian motion of arbitrary shaped aerosol particles by solving Euler’s equation of rotation. A Langevin formulation of the rotation equations is used, wherein Brownian motion due to thermal collisions between a particle and background gas molecules is represented using a stochastic fluctuating torque and fluid resistance is included as a drag torque. To avoid singularities associated with describing the orientation of a shape with Euler angles, we employ a quaternion formulation that leads to first-order stochastic differential equations to describe the evolution of the angular position and angular velocity of a rigid body. We perform all the rotational dynamics calculations in the body-fixed frame of reference attached to the rotating shape whose basis vectors are the normalized eigenvectors of the inertia tensor of the particle. Numerical solutions to rotation under torque-free conditions, damped rotation without Brownian motion, and stochastic rotation for arbitrary shapes are presented and discussed. The presented method enables time-resolved simulation of Brownian rotation for direct comparison with experimentally measured trajectories or statistical measures. The second order accuracy of the used time-stepping procedure places a severe restriction on the timestep that can be used for obtaining accurate results. Animations of presented simulations are included for visualizing rotational motion at various gas pressures. To aid implementation, MATLAB ® codes are also provided. Extension to include translation Brownian motion is straightforward.

Roy, Mrittika↗

A small core in Vesta inferred from Dawn’s observations

Vesta’s large-scale interior structure had previously been constrained primarily using the gravity and shape data from the Dawn mission. However, these data alone still allow a wide range of possibilities for the differentiation state of the body. The moment of inertia is arguably the most diagnostic parameter related to the radial density distribution of a planetary body, making it crucial for assessing the body’s state of internal differentiation. Determining the moment of inertia requires additional measurements of the amplitudes of small rotational motions, such as precession and nutation. Here we report an updated estimate of the moment of inertia of Vesta inferred from Dawn’s Doppler tracking via the Deep Space Network and onboard imaging data. The recovered value for Vesta’s normalized polar moment of inertia is $\overline{C}$/MR 2 = 0.4208 ± 0.0047 (where M is the mass of Vesta and R is the reference radius), which is only 6.6% lower than the homogeneous value of 0.4505. This value, combined with the gravity field and global shape, suggests that Vesta’s interior has limited density stratification beneath its howardite–eucrite–diogenite-dominated crust. We propose two possible origin scenarios that are consistent with the observed constraints. In the first scenario, Vesta’s interior did not undergo full differentiation due to late accretion. In the second scenario, Vesta originated as an impact remnant of a larger differentiated body re-accreted with non-chondritic bulk composition produced from a catastrophic impact. Vesta did not experience complete differentiation in either scenario, suggesting that its current state reflects a complex interplay between its accretion timing, thermal evolution, redistribution of 26 Al bearing melt and/or impact processes.

CNEOS 2014-01-08 bolide↗