Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thermal performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Electrical and Thermal Performance of Ga₂O₃–Al₂O₃–Diamond Super-Junction Schottky Barrier Diodes

The design space of Ga 2 O 3 -based devices is severely constrained due to its low thermal conductivity and absence of viable p-type dopants. In this work, we discuss the limits of operation of a novel Ga 2 O 3 –Al 2 O 3 –diamond-based super-junction device concept, which can alleviate the constraints associated with Ga 2 O 3 -based devices. The improvements achieved using the proposed device concept are demonstrated through electrical and thermal simulations of Ga 2 O 3 –Al 2 O 3 –diamond-based super-junction Schottky barrier diodes (SJ-SBDs) and non-punch-through or conventional Schottky barrier diodes (NP-SBDs). The SJ-SBD enables operation below the R ON -breakdown voltage limit of Ga 2 O 3 NP-SBD, enabling >4 kV blocking voltage at R ON of 1–3 mΩ cm 2 . Here, the maximum switching frequency of SJ-SBD may be only a few kHz, as it is limited by the activation energy of acceptors (0.39 eV) in the diamond. Crucially, compared with NP-SBD, the use of diamond also results in ~60% reduction in temperature rise during static power dissipation. Polycrystalline diamond (PCD) properties depend on detailed microstructure and benefits compared to ideal Ga 2 O 3</sub NP-SBD arise for diamond critical fields ≥6 MV/cm and thermal conductivities as low as 50–150 W/(m • K).

36 MATERIALS SCIENCE↗

Intraspecific Diversity in Thermal Performance Determines Phytoplankton Ecological Niche

ABSTRACT Temperature has a primary influence on phytoplankton physiology and ecology. We grew 12 strains of Gephyrocapsa huxleyi isolated from different‐temperature regions for ~45 generations (2 months) and characterised acclimated thermal response curves across a temperature range. Even with similar temperature optima and overlapping cell size, strain growth rates varied between 0.45 and 1 day −1 . Thermal niche widths varied from 16.7°C to 24.8°C, suggesting that strains use distinct thermal response mechanisms. We investigated the implications of this thermal intraspecific diversity using an ocean ecosystem simulation resolving phytoplankton thermal phenotypes. Model analogues of thermal ‘generalists’ and ‘specialists’ resulted in a distinctive global biogeography of thermal niche widths with a nonlinear latitudinal pattern. We leveraged model output to predict ranges of the 12 lab‐reared strains and demonstrated how this approach could broadly refine geographic range predictions. Our combination of observations and modelled biogeography highlights the capacity of diverse groups to survive temperature shifts.

Krinos, Arianna I. [Department of Biology Woods Ho↗

Multiscale Modeling of Silicon Carbide Cladding for Nuclear Applications: Thermal Performance Modeling

The complex multiscale and anisotropic nature of silicon carbide (SiC) ceramic matrix composite (CMC) makes it difficult to accurately model its performance in nuclear applications. The existing models for nuclear grade composite SiC do not account for the microstructural features and how these features can affect the thermal and structural behavior of the cladding and its anisotropic properties. In addition to the microstructural features, the properties of individual constituents of the composites and fiber tow architecture determine the bulk properties. Models for determining the relationship between the individual constituents’ properties and the bulk properties of SiC composites for nuclear applications are absent, although empirical relationships exist in the literature. Here, a hierarchical multiscale modeling approach was presented to address this challenge. This modular approach addressed this difficulty by dividing the various aspects of the composite material into separate models at different length scales, with the evaluated property from the lower-length-scale model serving as an input to the higher-length-scale model. The multiscale model considered the properties of various individual constituents of the composite material (fiber, matrix, and interphase), the porosity in the matrix, the fiber volume fraction, the composite architecture, the tow thickness, etc. By considering inhomogeneous and anisotropic contributions intrinsically, our bottom-up multiscale modeling strategy is naturally physics-informed, bridging constitutive law from micromechanics to meso-mechanics and structural mechanics. The effects that these various physical attributes and thermo-physical properties have on the composite’s bulk thermal properties were easily evaluated and demonstrated through the various analyses presented herein. Since silicon carbide fiber-reinforced SiC CMCs are also promising thermal–structural materials with a broad range of high-end technology applications beyond nuclear applications, we envision that the multiscale modeling method we present here may prove helpful in future efforts to develop and construct reinforced CMCs and other advanced composite nuclear materials, such as MAX phase materials, that can service under harsh environments of ultrahigh temperatures, oxidation, corrosion, and/or irradiation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal performance and energy consumption validation of an occupied local government office building outfitted with ceiling tile phase change materials

Buildings present an opportunity for energy conservation and the modulation of peak energy demand through controlled Heating, Ventilation, and Air Conditioning (HVAC) energy use. The administrative and office building stock in the United States holds potential to achieve energy and demand savings through retrofits such as insulation, weatherization, and thermal energy storage. Specifically, there is a need to validate passive phase change material (PCM) applications in full scale in aging administrative buildings in the US to evaluate the energy benefits. Aim of this study was to conduct a whole building level thermal and energy validation of an operational building and explore an alternative method for evaluating energy efficiency. To accomplish this, the study employed PCMs in the drop ceiling and carry out an energy audit and on-site measurement of HVAC systems' energy demand and consumption. A full-scale EnergyPlus energy model, modeled by the authors, served as a baseline for evaluation. The results show that calibrated model's envelope temperature measures fall within the accepted errors. HVAC energy simulation results also fall within the accepted errors for monthly and hourly pre- and post- PCM retrofit electricity and natural gas data. The novelty of this study is that it employees energy scales per Heating Degree Hour and Cooling Degree Hour, in contrast to the commonly used Heating Degree Days and Cooling Degree Days as reported in the literature to analyze energy savings. These findings underscore the pivotal role of a calibrated model in assessing the efficacy of a singular energy measure, like a PCM-retrofitted ceiling, in an occupied office building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sequential Dual Alignments Introduce Synergistic Effect on Hexagonal Boron Nitride Platelets for Superior Thermal Performance

Planarly aligning 2D platelets is challenging due to their additional orientational freedom compared to 1D materials. Here, this study reports a sequential dual-alignment approach, employing an extrusion-printing-induced shear force and rotating-magnetic-field-induced force couple for platelet planarly alignment in a yield-stress support bath. It is hypothesized that the partial alignment induced by a directional shear force facilitates subsequent axial rotation of the platelets for planar alignment under an external force couple, resulting in a synergistic alignment effect. This sequential dual-alignment approach achieves better planar alignment of 2D modified hexagonal boron nitride (mhBN). Specifically, the thermal conductivity of the 40 wt% mhBN/epoxy composite is significantly higher (692%) than that of unaligned composites, surpassing the cumulative effect of individual methods (only 133%) with a 5 times more synergistic effect. For 30, 40, and 50 wt% mhBN composites, the thermal conductivity values (5.9, 9.5, and 13.8 W m –1 K –1 ) show considerable improvement compared to the previously reported highest values (5.3, 6.6, and 8.6 W m –1 K –1 ). Additionally, a 3D mhBN/epoxy heat sink is printed and evaluated to demonstrate the feasibility of device fabrication. The approach enables the planar alignment of electrically or thermally conducting 2D fillers during 3D fabrication.

36 MATERIALS SCIENCE↗

The importance of maldistribution matching for thermal performance of compact heat exchangers

Compact heat exchangers have gained increased attention in recent years, particularly in demanding applications where high temperatures, high pressures, and/or high power densities are required. For decades, the heat exchanger (HX) community believes that flow maldistribution is a key factor for HX effectiveness, that is, reducing the degree of flow maldistribution (MALD) can help increase the HX effectiveness. Therefore, significant efforts have been devoted in the past to optimizing the header geometry to minimize flow maldistribution. This work was initially motivated by this, and the original goal was to figure out a HX header design with the lowest maldistribution. However, by systematically constructing a comprehensive maldistribution matrix, the analysis revealed that the HX effectiveness is not actually determined by the MALD, but instead dominated by the degree of maldistribution mismatch (MISM). This conclusion was also theoretically generalized, which indicated that matching of the local heat capacity rate is key for achieving maximum performance. The MISM provides a local means of tracking this information, while the MALD only provides a global approximation of the maldistribution itself. With this new perspective, flow maldistribution needs not necessarily be avoided, but instead matched between two fluid streams, to improve the HX performance. We demonstrated that by carefully designing the header geometry to match the velocity profiles of the two fluids in a 2 MW PCHE with molten salt and supercritical carbon dioxide (sCO2) as the heat transfer fluids, the HX could achieve a higher effectiveness even when the maldistribution increased. Finally, a technoeconomic study using a CSP system as an example revealed that the use of this new HX design paradigm could result in CSP capital cost savings as large as 16.6%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal performance of an absorption-assisted two-stage ejector air-to-water heat pump

In this work, a gas-fired air-to-water ejector heat pump (EHP) for domestic hot water production is proposed and analyzed thermodynamically. The COP of the EHP is improved by using binary fluids (HFE7500 and water), and the high backpressure in the primary ejector (first-stage) is actively controlled by either a second-stage ejector and/or a LiBr-H 2 O absorption subsystem. A thermodynamic model is established for analysis and performance evaluation. A case study shows the backpressure of the first-stage ejector is reduced by 53.5%, and the backpressure control using the second-stage ejector increases the system COP by 21.0% compared with that using LiBr-H 2 O absorption. Parametric studies are conducted to investigate the roles of the first-stage ejector, the second-stage ejector, and the LiBr-H 2 O absorption subsystem. The first-stage ejector plays a dominant role in the EHP system performance. The EHP’s heating COP can reach 2.0 with an entrainment ratio of 0.12 in the first-stage ejector. EHP performance can be improved with a high entrainment ratio and a low-temperature primary working fluid in the first-stage and second-stage ejectors, a low condensation temperature in the first-stage ejector, and a high generating temperature and a low concentration of the LiBr-H 2 O solution.

30 DIRECT ENERGY CONVERSION↗

Structured large-pore foams improve thermal performance of LiMIT-style liquid lithium PFC

As magnetically confined fusion devices improve, the conditions at the walls become increasingly intense. Plasma facing components (PFCs) must withstand these extreme heat and particle loads without damage or degradation. Liquid lithium PFCs are known to be quite resilient, and the presence of lithium also serves to improve plasma properties. The liquid metal infused trench (LiMIT) concept is an open surface liquid lithium PFC design that has been tested extensively at the University of Illinois and in fusion devices around the world. LiMIT utilizes thermoelectric magnetohydrodynamics (TEMHD) to passively drive liquid lithium flow. This work demonstrates an extension of the LiMIT trench geometry to three dimensions. Additively manufactured large pore metallic foams maintain TEMHD drive while drastically improving heat flux handling and resistance to lithium dryout, a phenomenon where locally high TEMHD forces depresses the lithium level and exposes underlying solid structure. COMSOL multiphysics modeling of the system yields insight into the forces at play in dryout development, and shows the 3D structures can eliminate dryout. Here, low heat proof-of-concept experimental testing of the system matches computational results, and high heat flux electron beam tests more than double the proven operational range of a LiMIT-style PFC, to 6.8 MW m –2 , with no indications of dryout or impending damage.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparative Thermal Performance of Downdraft and Updraft Forced Convection in a Representative 3x3 PWR Fuel Assembly

A plethora of theoretical, numerical, and experimental investigations have relied on updraft forced convection of operating fuel assemblies for light water-cooled fuel assemblies. The inertial scales of turbulence in updraft flow through PWR fuel assemblies are primarily influenced by upstream mixing patterns within the lower plenum and consequent acceleration of flow through the lower core and support plates into the bottom nozzles. In secondary heat transfer applications such as steam generation, recuperation and economization, downdraft flow is utilized to retrieve maximal sensible heat from the primary coolant. Sub-channel volumes aligned vertically could also benefit from force of gravity in developing turbulent flows. A large reduction in pumping power, associated cost of operation and maintenance, and improved balance of plant is suggested to be possible through downdraft forced convection in PWR-type reactors. This article explores the impact of downdraft forced convection within the well-studied 3x3 sub-channel within a range of 20 hydraulic diameters across a representative intermediate flow mixing grid. A range of inflow Reynolds number from 10,000 to 60,000 is simulated over a range of equivalent heat loads of 20% to 100% spanning 20 hydraulic diameters. The fuel rods are represented in true geometric detail, and a constant-value heat profile is assumed for the investigation. At each inflow condition, the turbulence intensity, peak velocity, local heat transfer coefficient, peak wall heat flux, and peak wall temperature are collected across the sub-channel and compared with an updraft configuration evaluated at the same conditions.

Rao, Vivek↗