Search NASA⌕ Search

SEARCH · Search NASA

Results for “Threshold Estimate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Improving Spectral Image Classification through a Custom Data Sparsing and Pixel Clustering Algorithm

The Underground Nuclear Explosion Signatures Experiment (UNESE) seeks to characterize non-prompt observables from underground nuclear explosions (UNE). As part of this effort, we evaluated the ability of Digital Globe’s World View-3 (WV3) to detect and map UNE signatures. WV3 has proven capabilities in the detection of large-scale, anomalous, man-made features; however, it has relatively limited spectral and spatial resolution as compared to airborne hyperspectral imaging. These limitations impede standard image classifiers from identifying UNE signatures that are spatially small and lack distinct spectral features. In order to improve image classification results, we developed a custom algorithm that increases the true positive rate, while decreasing the false positive rate. Our algorithm’s flexible front-end allows the user to choose the method used to sparse the data. These methods include band-ratio optimization, correlation coefficient threshold, or Adaptive Coherence Estimator (ACE) threshold. The resulting sparsed pixels are clustered into like-objects. A novel weighted-sum of ACE and correlation coefficient scores is used to classify each object based on the average spectrum of its constituent pixels. WV3 and AVIRIS data of Cuprite, Nevada were used as a verification data set. This algorithm improves overall pixel classification accuracy over standard classifiers by up to 14%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Calibration of Autonomous Coherent Doppler Lidar for Space Missions

Developed a new algorithm for the simulation of three dimensional homogeneous turbulent velocity fields. For typical atmospheric conditions it is impossible to produce a simulated velocity field that simultaneously satisfy a given spatial correlation and the corresponding spatial spectrum because of spectral aliasing. The new algorithms produce a turbulent velocity field which has accurate spatial correlations which is required for performance predictions from space-based systems. Developed a new algorithm for extracting the spatial statistics of the atmospheric velocity field using coherent Doppler lidar. The performance of the algorithm was compared with past methods and the new algorithm produces useful results for space-based data, which was not possible before. Developed new methods for verification of the errors in ground-based and space-based Doppler lidar wind measurements. These new methods do not require independent in situ data. This is an important issue for the verification of space-based Doppler lidar measurements of the global wind field. The performance of the new algorithm was compared with past results for both space-based and ground-based operation. The new algorithm has the best performance and is the only algorithm that performed satisfactory for spacebased operation. The performance of coherent Doppler lidar for a space missions with various scanning geometries was determined using computer simulation which contained the effects of random instrumental velocity errors, wind shear, wind variability along the range-gate and from shot-to-shot, and random variations in atmospheric aerosol backscatter over the measurement volume. The bias in the velocity estimates was small and the accuracy in the is typically less than 0.5 m/s for high signal conditions. For a large number of shot per velocity estimate, the threshold signal level for acceptable estimates is proportional to the number of shots to the minus one half power. This agrees with previous results determined for ground-based measurements. The use of multi-element optical detectors for autonomous operation of coherent Doppler lidar was shown to be a very promising technique. Optimal detector geometries were determined by computer simulation of performance: for ground-based testing with a fixed calibration target and for space-based operation using the random surface returns. The effects of refractive turbulence on ground-based calibration of coherent Doppler lidar was determined by computer simulations and compared with theoretical predictions. New techniques were required to correctly predict performance for the focused beam geometry commonly used for verification of space-based operation. An improved velocity estimator was evaluated for space-based applications were signal shot measurements are used to produce vector wind measurements. This permits more accurate measurements when the signal level is not known a priori or not available from multiple shot measurements. The average Doppler lidar signal spectrum including the effects of velocity turbulence was derived and calculated. This permits new estimation algorithms for turbulence based on spectral estimates. In situ atmospheric measurements were conducted and analyzed using an instrumented kite-platform. This work helps provide the required in situ data for verification of Doppler lidar velocity statistics.

Frehlich, Rod G.↗

Gas Composition Sensing Using Carbon Nanotube Arrays

This innovation is a lightweight, small sensor for inert gases that consumes a relatively small amount of power and provides measurements that are as accurate as conventional approaches. The sensing approach is based on generating an electrical discharge and measuring the specific gas breakdown voltage associated with each gas present in a sample. An array of carbon nanotubes (CNTs) in a substrate is connected to a variable-pulse voltage source. The CNT tips are spaced appropriately from the second electrode maintained at a constant voltage. A sequence of voltage pulses is applied and a pulse discharge breakdown threshold voltage is estimated for one or more gas components, from an analysis of the current-voltage characteristics. Each estimated pulse discharge breakdown threshold voltage is compared with known threshold voltages for candidate gas components to estimate whether at least one candidate gas component is present in the gas. The procedure can be repeated at higher pulse voltages to estimate a pulse discharge breakdown threshold voltage for a second component present in the gas. The CNTs in the gas sensor have a sharp (low radius of curvature) tip; they are preferably multi-wall carbon nanotubes (MWCNTs) or carbon nanofibers (CNFs), to generate high-strength electrical fields adjacent to the tips for breakdown of the gas components with lower voltage application and generation of high current. The sensor system can provide a high-sensitivity, low-power-consumption tool that is very specific for identification of one or more gas components. The sensor can be multiplexed to measure current from multiple CNT arrays for simultaneous detection of several gas components.

Li, Jing↗

Balancing energy conservation and occupant needs in ventilation rate standards for Big Box stores in California. Predicted indoor air quality and energy consumption using a matrix of ventilation scenarios (Final Report)

Through mass-balance modeling of various ventilation scenarios that might satisfy the ASHRAE 62.1 Indoor Air Quality (IAQ) Procedure, we estimate indoor concentrations of contaminants of concern (COCs) in California “big box” stores, compare estimates to available thresholds, and for selected scenarios estimate differences in energy consumption. Findings are intended to inform decisions on adding performance-based approaches to ventilation rate (VR) standards for commercial buildings. Using multi-zone mass-balance models and available contaminant source rates, we estimated concentrations of 34 COCs for multiple ventilation scenarios: VRmin (0.04 cfm/ft 2 ), VRmax (0.24 cfm/ft 2 ), and VRmid (0.14 cfm/ft 2 ). We compared COC concentrations with available health, olfactory, and irritant thresholds. We estimated building energy consumption at different VRs using a previously developed EnergyPlus model. VRmax did control all contaminants adequately, but VRmin did not, and VRmid did so only marginally. Air cleaning and local ventilation near strong sources both showed promise. Higher VRs increased indoor concentrations of outdoor air pollutants. Lowering VRs in big box stores in California from VRmax to VRmid would reduce total energy use by an estimated 6.6% and energy costs by 2.5%. Reducing the required VRs in California’s big box stores could reduce energy use and costs, but poses challenges for health and comfort of occupants. Source removal, air cleaning, and local ventilation may be needed at reduced VRs, and even at current recommended VRs. Also, alternative ventilation strategies taking climate and season into account in ventilation schedules may provide greater energy cost savings than constant ventilation rates, while improving IAQ.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Windblown dust on earth, Mars and Venus

Attempts to predict threshold speeds for windblown dust and sand on Mars and Venus have raised new questions about the mechanism of soil and sand transport by wind. Estimates of threshold speeds on Mars and Venus are made including the effects of both Reynolds number and interparticle forces of cohesion. The current estimates show lower threshold speeds for small particles than previous estimates by Hess, who assumed that Reynolds number is the only important parameter. These estimates, on the other hand, show somewhat higher threshold speeds than those of Sagan and Bagnold, who assumed that the particles are cohesionless. An optimum particle size results, for which threshold speed is a minimum, contrary to Sagan and Bagnold's prediction.

Iversen, J. D.↗

Results from 2015 and the 2016 upgrade of the CONNIE experiment for detecting coherent neutrino nucleus scattering

The CONNIE Experiment (Coherent Neutrino Nucleus Interaction Experiment) is currently collecting reactor neutrino data to search for the undiscovered standard model process of coherent neutrino-nucleus scattering (CNNS). The detector is composed of a silicon target of thick, fully-depleted, low-noise CCD detectors. Results from data collected in 2015 indicate backgrounds are controlled, and allow an estimate of sensitivity to be presented for a larger scale detector. A 2016 upgrade, adding additional target mass, and reducing readout noise, has been performed, increasing the total yield of signal events by a factor of 30, and already yielding science-quality data. Low-energy nuclear calibrations have been performed, enabling calibration down to the device energy threshold. An estimate of the sensitivity expected for measuring the coherent neutrino process is presented. Future prospects with improved detector energy thresholds are estimated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gyrokinetic simulation of driftwave instability in field-reversed configuration

Following the recent remarkable progress in magnetohydrodynamic (MHD) stability control in the C-2U advanced beam driven field-reversed configuration (FRC), turbulent transport has become one of the foremost obstacles on the path towards an FRC-based fusion reactor. Significant effort has been made to expand kinetic simulation capabilities in FRC magnetic geometry. The recently upgraded Gyrokinetic Toroidal Code (GTC) now accommodates realistic magnetic geometry from the C-2U experiment at Tri Alpha Energy, Inc. and is optimized to efficiently handle the FRC's magnetic field line orientation. Initial electrostatic GTC simulations find that ion-scale instabilities are linearly stable in the FRC core for realistic pressure gradient drives. Estimated instability thresholds from linear GTC simulations are qualitatively consistent with critical gradients determined from experimental Doppler backscattering fluctuation data, which also find ion scale modes to be depressed in the FRC core. Beyond GTC, A New Code (ANC) has been developed to accurately resolve the magnetic field separatrix and address the interaction between the core and scrape-off layer regions, which ultimately determines global plasma confinement in the FRC. The current status of ANC and future development targets are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Unified Nonlinear Adaptive Approach for Detection and Isolation of Engine Faults

A challenging problem in aircraft engine health management (EHM) system development is to detect and isolate faults in system components (i.e., compressor, turbine), actuators, and sensors. Existing nonlinear EHM methods often deal with component faults, actuator faults, and sensor faults separately, which may potentially lead to incorrect diagnostic decisions and unnecessary maintenance. Therefore, it would be ideal to address sensor faults, actuator faults, and component faults under one unified framework. This paper presents a systematic and unified nonlinear adaptive framework for detecting and isolating sensor faults, actuator faults, and component faults for aircraft engines. The fault detection and isolation (FDI) architecture consists of a parallel bank of nonlinear adaptive estimators. Adaptive thresholds are appropriately designed such that, in the presence of a particular fault, all components of the residual generated by the adaptive estimator corresponding to the actual fault type remain below their thresholds. If the faults are sufficiently different, then at least one component of the residual generated by each remaining adaptive estimator should exceed its threshold. Therefore, based on the specific response of the residuals, sensor faults, actuator faults, and component faults can be isolated. The effectiveness of the approach was evaluated using the NASA C-MAPSS turbofan engine model, and simulation results are presented.

Tang, Liang↗

Developing evidence-based prescriptive ventilation rate standards for commercial buildings in California: a proposed framework

Background - The goal of this project, with a focus on commercial buildings in California, was to develop a new framework for evidence-based minimum ventilation rate (MVR) standards that protect occupants in buildings while also considering energy use and cost. This was motivated by research findings suggesting that current prescriptive MVRs in commercial buildings do not provide occupants with fully safe and satisfactory indoor environments. Methods - The project began with a broad review in several areas ? the diverse strategies now used for standards or guidelines for MVRs or for environmental contaminant exposures, current knowledge about adverse human effects associated with VRs, and current knowledge about contaminants in commercial buildings, including their their presence, their adverse human effects, and their relationships with VRs. Based on a synthesis of the reviewed information, new principles and approaches are proposed for setting evidence-based VRs standards for commercial buildings, considering a range of human effects including health, performance, and acceptability of air. Results ? A review and evaluation is first presented of current approaches to setting prescriptive building ventilation standards and setting acceptable limits for human contaminant exposures in outdoor air and occupational settings. Recent research on approaches to setting acceptable levels of environmental exposures in evidence-based MVR standards is also described. From a synthesis and critique of these materials, a set of principles for setting MVRs is presented, along with an example approach based on these principles. The approach combines two sequential strategies. In a first step, an acceptable threshold is set for each adverse outcome that has a demonstrated relationship to VRs, as an increase from a (low) outcome level at a high reference ventilation rate (RVR, the VR needed to attain the best achievable levels of the adverse outcome); MVRs required to meet each specific outcome threshold are estimated; and the highest of these MVRs, which would then meet all outcome thresholds, is selected as the target MVR. In a second step, implemented only if the target MVR from step 1 is judged impractically high, costs and benefits are estimated and this information is used in a risk management process. Four human outcomes with substantial quantitative evidence of relationships to VRs are identified for initial consideration in setting MVR standards. These are: building-related symptoms (sometimes called sick building syndrome symptoms), poor perceived indoor air quality, and diminished work performance, all with data relating them directly to VRs; and cancer and non-cancer chronic outcomes, related indirectly to VRs through specific VR-influenced indoor contaminants. In an application of step 1 for offices using a set of example outcome thresholds, a target MVR of 9 L/s (19 cfm) per person was needed. Because this target MVR was close to MVRs in current standards, use of a cost/benefit process seemed unnecessary. Selection of more stringent thresholds for one or more human outcomes, however, could raise the target MVR to 14 L/s (30 cfm) per person or higher, triggering the step 2 risk management process. Consideration of outdoor air pollutant effects would add further complexity to the framework. For balancing the objective and subjective factors involved in setting MVRs in a cost-benefit process, it is suggested that a diverse group of stakeholders make the determination after assembling as much quantitative data as possible.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Audibility of Multiple, Low-Frequency Tonal Signals in Noise

The main purpose of this study is to examine the audibility of multiple, low-frequency tones that are placed in distinct auditory channels. Three experiments are described, the goals of which are to determine if the presence of sound in multiple channels results in enhanced audibility and to assess the applicability of the Statistical Summation Model (SSM) to this frequency range. This model predicts that for the case of multiple signals that are in separate auditory channels, implying statistical independence, each with sensitivity value d prime of i, the resulting total sensitivity is given by the square root of the sum of the squares of the individual d prime of i values. In common with previous studies conducted at higher frequencies, the signals are pure tones and the maskers are broadband noise. The requirement that low frequency tones be placed in separate auditory filters limited the number of tones to a maximum of three. The first of the three experiments measured the change in masked thresholds for two- and three-tone signals relative to the level of the equally-detectable single tones. The multiple tone signals were composed of combinations of 55, 120 and 200 Hz tones. The measured changes in thresholds exceeded those predicted by the SSM, although they did not differ statistically from the model predictions. The second experiment employed the same overall approach but acquired more data and concentrated on the three-tone signal. Once again, the measured changes in masked threshold exceeded the model predictions, this time to a statistically-significant degree. Two issues were postulated with the potential to yield inflated changes in masked threshold: interaction between tones resulting in perceptible intermodulation/difference tones, and the assumption that the tones were in distinct auditory filters and statistically independent of one another. The third experiment used two sets of three-tone signals to address these latter concerns. The first set of three tones was composed of harmonically related tone frequencies of 55, 110 and 165 Hz, which was an attempt to reduce effects of intermodulation difference tones. The second set of three tones was chosen to be 110, 220 and 330 Hz, again reducing effects of difference tones, but also providing greater separation between tones. Results for the first set of three tones compared to those of the earlier experiments indicated that intermodulation was not an important effect. The second set of three tones (110, 220, 330 Hz) yielded changes in masked thresholds that, on average, were in good agreement with the SSM, although intersubject variability was large and prohibited a definitive conclusion regarding the concern that tone spacing was inadequate. The results of the three experiments showed that the masked threshold of sounds with multiple (two or three) equally-detectable low frequency tones was lower than those of the single tones. In other words, it is clear that audibility is enhanced by the presence of signals in multiple auditory filters. This finding is consistent with most previous research conducted at higher frequencies. In contrast with previous research, test subjects were, on average, able to detect multitone sounds at lower levels than those predicted using the SSM. Analyses that included Monte Carlo simulations showed that normally distributed errors in the single tone thresholds result in biased estimates of the thresholds of multitone sounds. This phenomenon is likely responsible for at least a substantial fraction of the unexpected deviation of measurements from SSM predictions.

Rafaelof, Menachem↗

Parafoveal Target Detectability Reversal Predicted by Local Luminance and Contrast Gain Control

This project is part of a program to develop image discrimination models for the prediction of the detectability of objects in a range of backgrounds. We wanted to see if the models could predict parafoveal object detection as well as they predict detection in foveal vision. We also wanted to make our simplified models more general by local computation of luminance and contrast gain control. A signal image (0.78 x 0.17 deg) was made by subtracting a simulated airport runway scene background image (2.7 deg square) from the same scene containing an obstructing aircraft. Signal visibility contrast thresholds were measured in a fully crossed factorial design with three factors: eccentricity (0 deg or 4 deg), background (uniform or runway scene background), and fixed-pattern white noise contrast (0%, 5%, or 10%). Three experienced observers responded to three repetitions of 60 2IFC trials in each condition and thresholds were estimated by maximum likelihood probit analysis. In the fovea the average detection contrast threshold was 4 dB lower for the runway background than for the uniform background, but in the parafovea, the average threshold was 6 dB higher for the runway background than for the uniform background. This interaction was similar across the different noise levels and for all three observers. A likely reason for the runway background giving a lower threshold in the fovea is the low luminance near the signal in that scene. In our model, the local luminance computation is controlled by a spatial spread parameter. When this parameter and a corresponding parameter for the spatial spread of contrast gain were increased for the parafoveal predictions, the model predicts the interaction of background with eccentricity.

Ahumada, Albert J., Jr.↗

Decreasing Proton Single Event Effects in CubeSats with Shielding

Shields-1, NORAD ID 43850,has been operating in polar low earth orbit since December 2018. The shielding has resulted in a lower total ionizing dose over time than typical aluminum thin-walled CubeSat structures. The reduced ionizing dosage caused by Shields-1 increases the reliability of commercial parts and reduces internal charging. Furthermore, the Shields-1 shielding reduces the ionizing particle fluence inside the spacecraft that contributes to the ionizing dose. NOVICE Sigma shielding software, using the (Aerospace Proton) AP8 –(Aerospace Electron) AE8 solar minimum trapped belt environment for a 1-year mission, estimates a 21.3 g/cm2 aluminum effective shielding for the Shields-1 electronics enclosure. This high areal density reduces not only the total number of energetic protons, but also reduces the number of ionizing particles over all modeled energies from the estimated shielded fluence for a 1-year mission. NOVICE Adjoint CAD modeling of the Shields-1 structure, with the detector located within the electronics enclosure, estimates that the total number of particles is reduced from 2.20x 10exp9 protons/cm2 to 1.52x 10exp8 protons/cm2, which represents 6.90% of the remaining particles(figure 1). By slowing down approximations of the integral proton fluence, a minimum proton threshold is estimated at 151 MeV. In comparison, a 0.204-cm aluminum thin-walled 3-unit (U) structure, with a 0.907 g/cm2 effective shielding, has 25.0% remaining particles and a minimum proton threshold of 36.2 MeV(figure 1). Proton energies that contribute to single event effects in radiation tolerant or higher semiconductor hardness are typically 100 MeV and higher. The Shields-1 electronics enclosure is estimated to attenuate energies: 100 MeV by 76.5%, 200 MeV by 61.7%, and 500 MeV by 63.0%(figure 2), when comparing the space environment proton differential fluence with the shielded differential fluence. The aluminum thin-walled structure is estimated to attenuate proton energies: 100 MeV by 13.7%, 200 MeV by 12.4%, and 500 MeV by 12.6%(figure 2), which are lower than for the Shields-1 electronics enclosure. The significant differences in attenuation between the Shields-1 electronics enclosure and aluminum thin-walled 3U structure show the additional utility of increasing shielding effectiveness for reducing the numbers of energetic protons that contribute to single event effects.

Larry Thomsen↗

Two-step narrow ridge cascade diode lasers emitting near $2~\mu$ m

Nearly diffraction limited GaSb-based type-I quantum well cascade diode lasers emitting in the spectral region 1.95-2 μm were designed and fabricated. Two-step 5.5-μm-wide shallow and 14-μm-wide deep etched ridge waveguide design yielded devices generating stable single lobe beams with 250 mW of continuous wave output power at 20 °C. Quantum well radiative recombination current contributes about 13% to laser threshold as estimated from true spontaneous emission and modal gain analysis. Here, recombination at etched sidewalls of the 14-μmwide deep ridges controls about 30% of the threshold.

42 ENGINEERING↗

Midlatitude Lightning NOx Production Efficiency Inferred From OMI and WWLLN Data

Oxides of nitrogen are critical trace gases in the troposphere and are precursors for nitrate aerosol and ozone, which is an important pollutant and greenhouse gas. Lightning is the major source of NOx(NO + NO2) in the mid-to upper troposphere. We estimate the production efficiency (PE) of lightning NOx (LNOx) using satellite data from the Ozone Monitoring Instrument (OMI) and the ground-based WorldWide Lightning Location Network (WWLLN) in three northern midlatitude, primarily continental regions that include much of North America, Europe and East Asia. Data were obtained over 5 boreal summers, 2007 –2011 and comprise the largest number of midlatitude convective events to date for estimating the LNOx PE with satellite NO2and ground-based lightning measurements. In contrast to some previous studies, the algorithm assumes no minimum flash-rate threshold and estimates freshly produced LNOxby subtracting a background of aged NOx estimated from the OMI dataset itself. We infer an average value of 180 ± 100 moles LNOx produced per lightning flash. We also show evidence of a dependence of PE on lightning flash rate and find an approximate empirical power function relating moles LNOxto flashes. PE decreases by an order of magnitude for a 2-order of magnitude increase in flash rate. This phenomenon has not been reported in previous satellite LNOxstudies but is consistent with ground-based observations suggesting an inverse relationship between flash rate and size.

LNOx↗

Bayesian Geostatistical Modelling of PM10 and PM2.5 Surface Level Concentrations in Europe Using High-Resolution Satellite-Derived Products

Air quality monitoring across Europe is mainly based on in situ ground stations which are too sparse to accurately assess the exposure effects of air pollution for the entire continent. The demand for precise predictive modelsthat estimate gridded geophysical parameters of ambient air at high spatial resolution has rapidly grown. Here, we investigate the potential of satellite derived products to improve particulate matter (PM) estimates. Bayesiangeostatistical models addressing confounding between the spatial distribution of pollutants and remotely sensed predictors were developed to estimate yearly averages of both, fine (PM2.5) and coarse (PM10) surface PM concentrations at 1 sq.km spatial resolution over 46 European countries and were compared to geostatistical, geographically weighted and land-use regression formulations. Rigorous model selection identified the Earth observation data which contribute most to pollutants' estimation. Geostatistical models outperformed the predictive ability of the frequently employed land-use regression. The resulting estimates of PM10 and PM2.5, which represent the main air quality indicators for the urban Sustainable Development Goal, indicate that in 2016, 66.2% of the European population was breathing air above the WHO Air Quality Guidelines thresholds. Our estimates are readily available to policy makers and scientists assessing the effects of long-term exposure to pollution on human and ecosystem health.

Beloconi, Anton↗

LIGO-VIRGO Triggered Follow-Up with NASA High Energy Photon Survey Missions

We discuss the proposed use of LIGO-VIRGO S6 triggers from comparatively loud events to search for both prompt and afterglow EM counterparts with RXTE, SWIFT and FERMI. Using a 2 or 3-fold coincident trigger from the two LIGO and one VIRGO detectors to provide sky position information, we can search the data from these missions within a limited time window and a constrained portion of their respective FOVs, allowing us to look at a level below the threshold normally used to publicly indicate an event. Since we propose to use these missions in their survey mode, no re-pointing of the missions is envisioned. The search for a coincidence between the data from LIGO-VIRGO and the EM survey missions can then be analyzed off-line; if a coincident EM signal is found it would have a significant effect in establishing the validity of the GW trigger. We discuss some relevant aspects of the NASA missions and give some preliminary estimates of thresholds and coincident background rates.

Camp, Jordan↗