At least 55 records · Page 3

The Plasma Proton Environment within Saturn’s F-G Ring Gap as Observed by the Cassini Plasma Spectrometer Ion Mass Spectrometer during Saturn Orbit Insertion

We report on the detection of protons and the potential detection of H 2 + between Saturn's F and G rings based on Cassini Plasma Spectrometer (CAPS) Ion Mass Spectrometer (IMS) time-of-flight (TOF) composition measurements acquired during Saturn Orbit Insertion (SOI) outbound pass. The range in dipole L shell is 2.3 < L < 2.8. Initial results based on TOF data were presented in E. C. Sittler et al., 2017. Here we present the latest results of our analysis. During the SOI outbound pass between the F and G rings the CAPS IMS was in a mode of reduced post-acceleration voltage at -6 kV instead of the usual -14.6 kV. This reduced voltage still allows the analysis of protons since 6 keV protons are minimally scattered by the instrument’s ultrathin carbon foils when compared to heavier ions O + and O 2 + , scattering. Background noise from penetrating radiation and ghost peaks produced by foil-scattered O + ions within the instrument were considered in our analysis. The analysis allowed determination of the proton density, temperature and flow velocity, accounting for spacecraft potential by assuming a convected Maxwellian for the proton velocity distribution function. We find average proton density n P = 3.2 ± 1.1 #/cm 3 , proton temperature T P = 1.74 ± 0.12 eV, proton rotational flow speed V P = 24 ± 1.5 km/s and spacecraft potential  SC = -0.8 ±1.5 V. These results are compared with previous theoretical estimates of H + and H 2 + ions within Saturn’s inner magnetosphere.

E C Sittler↗

Spontaneous-Desorption Ionizer for a TOF-MS

A time-of-flight mass spectrometer (TOF-MS) like the one mentioned in the immediately preceding article has been retrofitted with an ionizer based on a surface spontaneous-desorption process. This ionizer includes an electron multiplier in the form of a microchannel plate (MCP). Relative to an ionizer based on a hot-filament electron source, this ionizer offers advantages of less power consumption and greater mechanical ruggedness. The current density and stability characteristics of the electron emission of this ionizer are similar to those of a filament-based ionizer. In tests of various versions of this ionizer in the TOF-MS, electron currents up to 100 nA were registered. Currents of microamperes or more - great enough to satisfy requirements in most TOFMS applications - could be obtained by use of MCPs different from those used in the tests, albeit at the cost of greater bulk. One drawback of this ionizer is that the gain of the MCP decreases as a function of the charge extracted thus far; the total charge that can be extracted over the operational lifetime is about 1 coulomb. An MCP in the ion-detector portion of the TOF-MS is subject to the same limitation.

Schultz, J. Albert↗

Miniature Focusing Time-of-Flight Mass Spectrometer

An improved miniature time-of-flight mass spectrometer has been developed in a continuing effort to minimize the sizes, weights, power demands, and costs of mass spectrometers for such diverse applications as measurement of concentrations of pollutants in the atmosphere, detecting poisonous gases in mines, and analyzing exhaust gases of automobiles. Advantageous characteristics of this mass spectrometer include the following: It is simple and rugged. Relative to prior mass spectrometers, it is inexpensive to build. There is no need for precise alignment of its components. Its mass range is practically unlimited Relative to prior mass spectrometers, it offers high sensitivity (ability to measure relative concentrations as small as parts per billion). Its resolution is one dalton (one atomic mass unit). An entire mass spectrum is recorded in a single pulse. (In a conventional mass spectrometer, a spectrum is recorded mass by mass.) The data-acquisition process takes only seconds. It is a lightweight, low-power, portable instrument. Although time-of-flight mass spectrometers (TOF-MSs) have been miniaturized previously, their performances have not been completely satisfactory. An inherent adverse effect of miniaturization of a TOF-MS is a loss of resolution caused by reduction of the length of its flight tube. In the present improved TOF-MS, the adverse effect of shortening the flight tube is counteracted by (1) using charged-particle optics to constrain ion trajectories to the flight-tube axis while (2) reducing ion velocities to increase ion flight times. In the present improved TOF-MS, a stream of gas is generated by use of a hypodermic needle. The stream of gas is crossed by an energy-selected, pulsed beam of electrons (see Figure 1). The ions generated by impingement of the electrons on the gas atoms are then focused by three cylindrical electrostatic lenses, which constitute a segmented flight tube. After traveling along the flight tube, the ions enter a charged-particle detector. The output of the detector is fed to a counting circuit to obtain data on the counting rate as a function of time. Inasmuch as time of flight is directly proportional to the ion mass, a plot of the counting rate versus time of flight is equivalent to a mass spectrum (see Figure 2).

Kanik, Isik↗

Detector response in time-of-flight mass spectrometry at high pulse repetition frequencies

Dead time effects in chevron configured dual microchannel plates (MCPs) are investigated. Response times are determined experimentally for one chevron-configured dual MCP-type detector and two discrete dynode-type electron multipliers with 16 and 23 resistively divided stages. All of these detectors are found to be suitable for time-of-flight mass spectrometry (TOF MS), yielding 3-6-ns (FWHM) response times triggered on a single ion pulse. It is concluded that, unless there are viable solutions to overcome dead time disadvantages for continuous dynode detectors, suitable discrete dynode detectors for TOF MS appear to have a significant advantage for high repetition rate operation.

Gulcicek, Erol E.↗

Discovery and Identification of Dimethylsilanediol as a Contaminant in ISS Potable Water

In September 2010, analysis of ISS potable water samples was undertaken to determine the contaminant(s) responsible for a rise of total organic carbon (TOC) in the Water Processor Assembly (WPA) product water. As analysis of the routine target list of organic compounds did not reveal the contaminant, efforts to look for unknown compounds were initiated, resulting in discovery of an unknown peak in the gas chromatography/mass spectrometry (GC/MS) analysis for glycols. A mass spectrum of the contaminant was then generated by concentrating one of the samples and analyzing it by GC/MS in full-scan mode. Although a computer match of the compound identity could not be obtained with the instrument database, a search with a more up-to-date mass spectral library yielded a good match with dimethylsilanediol (DMSD). Inductively coupled plasma/mass spectrometry (ICP/MS) analyses showed abnormally high silicon levels in the samples, confirming that the unknown compound(s) contained silicon. DMSD was then synthesized to confirm the identification and provide a standard to develop a calibration curve. Further confirmation was provided by external direct analysis in real time time of flight (DART TOF) mass spectrometry. To routinely test for DMSD in the future, a quantitative method was needed. A preliminary GC/MS method was developed and archived samples from various locations on ISS were analyzed to determine the extent of the contamination and provide data for troubleshooting. This paper describes these events in more detail as well as problems encountered in routine GC/MS analyses and the subsequent development of high performance liquid chromatography and LC/MS/MS methods for measuring DMSD.

Rutz, Jeffrey A.↗

Hypersonic Wake Diagnostics Using Laser Induced Fluorescence Techniques

A review of recent research performed in iodine that involves a two photon absorption of light at 193 nm will be discussed, and it's potential application to velocimetry measurements in a hypersonic flow field will be described. An alternative seed atom, Krypton, will be presented as a good candidate for performing nonintrusive hypersonic flow diagnostics. Krypton has a metastable state with a lifetime of approximately 43 s which would prove useful for time of flight measurement (TOF) and a sensitivity to collisions that can be utilized for density measurements. Calculations using modest laser energies and experimental values show an efficiency of excited state production to be on the order of 10(exp -6) for a two photon absorption at 193 nm.

Mills, Jack L.↗

Hybrid Ion-Detector/Data-Acquisition System for a TOF-MS

A modified ion-detector/data-acquisition system has been devised to increase the dynamic range of a time-of-flight mass spectrometer (TOF-MS) that, previously, included a microchannel-plate detector and a data-acquisition system based on counting pulses and time-tagging them by use of a time-to-digital converter (TDC). The dynamic range of the TOF-MS was limited by saturation of the microchannel plate detector, which can handle no more than a few million counts per second. The modified system includes (1) a combined microchannel plate/discrete ion multiplier and (2) a hybrid data-acquisition system that simultaneously performs analog current or voltage measurements and multianode single-ion-pulse-counting time-of-flight measurements to extend the dynamic range of a TDC into the regime in which a mass peak comprises multiple ions arriving simultaneously at the detector. The multianode data are used to determine, in real time, whether the detector is saturated. When saturation is detected, the data-acquisition system selectively enables circuitry that simultaneously determines the ion-peak intensity by measuring the time profile of the analog current or voltage detector-output signal.

Burton, William D., Jr.↗

Measurement Report :Emission Factors of NH3 and NHx for Wildfires and Agricultural Fires in the United States

During the 2019 Fire Influence on Regional to Global Environments and Air Quality (FIREX-AQ) study, the NASA DC-8 carried out in situ chemical measurements in smoke plumes emitted from wildfires and agricultural fires in the contiguous United States. The DC-8 payload included a modified proton-transfer-reaction time-of-flight mass spectrometer (PTR-ToF-MS) for the fast measurement of gaseous ammonia (NH 3 ) and a high-resolution time-of-flight aerosol mass spectrometer (AMS) for the fast measurement of submicron particulate ammonium (NH 4 + ). We herein report data collected in smoke plumes emitted from 6 wildfires in the Western United States, 2 prescribed grassland fires in the Central United States, 1 prescribed forest fire in the Southern United States, and 66 small agricultural fires in the Southeastern United States. Smoke plumes contained double to triple digit ppb levels of NH 3 . In the wildfire plumes, a significant fraction of NH 3 had already been converted to NH 4 + at the time of sampling (≥2 h after emission). Substantial amounts of NH 4 + were also detected in freshly emitted smoke from corn and rice field fires. We herein present a comprehensive set of emission factors of NH 3 and NH x , with NH x = NH 3 + NH 4 + . Average NH 3 and NH x emission factors for wildfires in the Western United States were 1.86±0.75 g kg −1 and 2.47±0.80 g kg −1 of fuel burned, respectively. Average NH 3 and NH x emission factors for agricultural fires in the Southeastern United States were 0.89±0.58 and 1.74±0.92 g kg −1 , respectively. Our data show no clear inverse correlation between modified combustion efficiency (MCE) and NH 3 emissions. The observed NH 3 emissions were significantly higher than measured in previous laboratory experiments in the FIREX FireLab 2016 study.

Laura Tomsche↗

MALDI TOF MS: An Exobiology Surface-Science Approach for Europa

If Europa is to be of primary exobiological interest, namely as a habitat for extant life, it is obvious that: (i) a hydrosphere must prevail beneath the cryosphere for a long time, (ii) internal energy sources must be present in a sufficient state of activity, and (iii) a reasonable technical means must be available for assessing if indeed life does exist in the hypothesized hydrosphere. This discussion focuses on technological issues, because the compounding evidence about Europa indicates that the first two are highly likely to be true. We present a consideration of time-of-flight mass spectroscopy (TOF MS) conducted in-situ on the cryosphere surface of Europa during a landed robotic mission. We assert that this is a reasonable technical means not only for exploring the composition of the cryosphere itself, but also for locating any biomolecular indicators of extant life brought to the surface through cryosphere activity. We also describe a MALDI (MAtrix Laser Desorption and Ionization) TOF MS system that we are constructing as a proof-of-concept prototype for conducting TOF MS measurements on Europa.

Gerakines, Perry A.↗

Multielement analysis of interplanetary dust particles using TOF-SIMS

Sections of three stratospheric particles (U2015G1, W7029*A27, and L2005P9) were analyzed with TOF-SIMS (Time Of Flight-Secondary Ion Mass Spectrometry) continuing our efforts to investigate the element distribution in interplanetary dust particles (IDP's) with high lateral resolution (approximately 0.2 micron), to examine possible atmospheric contamination effects, and to further explore the abilities of this technique for element analysis of small samples. The samples, previously investigated with SXRF (synchrotron X-ray fluorescence analysis), are highly enriched in Br (Br/Fe: 59 x CI, 9.2 x CI, and 116 x CI, respectively). U2015G1 is the IDP with the by far highest Zn/Fe-ratio (81 x CI) ever reported in chondritic particles.

Stephan, T.↗

Elemental, Isotopic, and Organic Analysis on Mars with Laser TOF-MS

The in-depth landed exploration of Mars will require increasingly sophisticated robotic analytical tools for both in situ composition science [1] and reconnaissance for sample return [2]. Beyond dust, rock surfaces, and topsoil, samples must be accessed within rocks and ice, well below surface soil, and possibly in elevated deposit layers. A range of spatial scales will be studied, and for the most information-rich microscopic analyses, samples must be acquired, prepared, and positioned with high precision. In some cases samples must also be brought into a vacuum chamber. After expending such resources, it will be important to apply techniques that provide a wide range of information about the samples. Microscopy, mineralogy, and molecular/organic, elemental, and isotopic analyses are all needed, at a minimum, to begin to address the in situ goals at Mars. These techniques must work as an efficient suite to provide layers of data, each layer helping to determine if further analysis on a given sample is desired. In the spirit of broad-band and efficient data collection, we are developing miniature laser time-of-flight mass spectrometers (TOF-MS) for elemental, isotopic, and molecular/organic microanalysis of unprepared solid samples. Laser TOF-MS uses a pulsed laser to volatilize and ionize material from a small region on the sample. The laser energy and focus can be adjusted for atomic and molecular content, sampling area, and depth. Ions travel through the instrument and are detected at a sequence of times proportional to the square root of their mass-to- charge ratios. Thus, each laser pulse produces a complete mass spectrum (in less than 50 microseconds). These instruments can now be significantly miniaturized (potentially to the size of a soda can) without a loss in performance. This effort is reviewed here with an emphasis on applications to Mars exploration.

Brinckerhoff, W. B.↗

OASIS: Organics Analyzer for Sampling Icy Surfaces

Liquid chromatography mass spectrometry (LC-MS) is a well established laboratory technique for detecting and analyzing organic molecules. This approach has been especially fruitful in the analysis of nucleobases, amino acids, and establishing chirol ratios [1 -3]. We are developing OASIS, Organics Analyzer for Sampling Icy Surfaces, for future in situ landed missions to astrochemically important icy bodies, such as asteroids, comets, and icy moons. The OASIS design employs a microfabricated, on-chip analytical column to chromatographically separate liquid ana1ytes using known LC stationary phase chemistries. The elution products are then interfaced through electrospray ionization (ESI) and analyzed by a time-of-flight mass spectrometer (TOF-MS). A particular advantage of this design is its suitability for microgravity environments, such as for a primitive small body.

Getty, S. A.↗

Development of a Robust, High Current, Low Power Field Emission Electron Gun for a Spaceflight Reflectron Time-of-Flight Mass Spectrometer

Carbon materials, including carbon nanotubes (CNTs) and nitrogen-incorporated ultrananocrystalline diamond (N-UNCD), have been of considerable interest for field emission applications for over a decade. In particular, robust field emission materials are compelling for space applications due to the low power consumption and potential for miniaturization. A reflectron time-of-flight mass spectrometer (TOF-MS) under development for in situ measurements on the Moon and other Solar System bodies uses a field emitter to generate ions from gaseous samples, using electron ionization. For these unusual environments, robustness, reliability, and long life are of paramount importance, and to this end, we have explored the field emission properties and lifetime of carbon nanotubes and nitrogen-incorporated ultrananocrystalline diamond (N-UNCD) thin films, the latter developed and patented by Argonne National Laboratory. We will present recent investigations of N-UNCD as a robust field emitter, revealing that this material offers stable performance in high vacuum for up to 1000 hours with threshold voltage for emission of about 3-4 V/lJm and current densities in the range of tens of microA. Optimizing the mass resolution and sensitivity of such a mass spectrometer has also been enabled by a parallel effort to scale up a CNT emitter to an array measuring 2 mm x 40 mm. Through simulation and experiment of the new extended format emitter, we have determined that focusing the electron beam is limited due to the angular spread of the emitted electrons. This dispersion effect can be reduced through modification of the electron gun geometry, but this reduces the current reaching the ionization region. By increasing the transmission efficiency of the electron beam to the anode, we have increased the anode current by two orders of magnitude to realize a corresponding enhancement in instrument sensitivity, at a moderate cost to mass resolution. We will report recent experimental and modeling results to describe the performance of a field emission electron gun as employed in the Volatile Analysis by Pyrolysis of Regolith (VAPoR) TOF-MS prototype.

Southard, Adrian E.↗

Characterization of a Carbon Nanotube Field Emission Electron Gun for the VAPoR Miniaturized Pyrolysis-Time-of-Flight Mass Spectrometer

We are developing the VAPoR (Volatile Analysis by Pyrolysis of Regolith) instrument towards studying soil composition, volatiles, and trapped noble gases in the polar regions of the Moon. VAPOR will ingest a soil sample and conduct analysis by pyrolysis and time-of-flight mass spectrometry (ToF-MS). Here, we describe miniaturization efforts within this development, including a carbon nanotube (CNT) field emission electron gun that is under consideration for use as the electron impact ionization source for the ToF-MS.

Getty, Stephanie↗

Congruence of Clusters Defined By Whole Genome Sequencing and MALDI-TOF for Bacteria Isolated From Cleanrooms

Introduction: Oligotrophic conditions can render cleanrooms inhospitable to microbes. Despite these constraints, fungi and bacteria are frequently isolated from surfaces in astromaterials cleanrooms at the Johnson Space Center. Bacillus species are of particular concern because endospores belonging to this genus are resilient and can affect astromaterials. Current monitoring programs rely on 16S rRNA sequencing and the VITEK2 Compact system. These methods have limited power to resolve Bacillus species. Matrix-assisted laser desorption - time of flight mass spectrometry (MALDI-TOF MS), provides a rapid, low cost, method of identifying bacterial isolates and has a higher resolution than 16S rRNA sequencing, particularly for Bacillus species; however, few studies have compared this method to the industry gold standard, whole genome sequencing (WGS). Methods: Based on 16S rRNA classification, we selected 14 isolates for analysis with MALDI-TOF and WGS. Mass spectra were generated with MALDI-TOF MS and processed with custom scripts to identify clusters of closely related isolates and calculate a matrix of pairwise cosine similarity scores. Hybrid Illumina and Nanopore sequencing were used to generate draft genomes. Pairwise similarity scores were calculated from these genomes based on the average amino acid identity (AAI) predicted from single copy core genes. Congruence of clustering between these methods, was assessed by calculating adjusted Rand and Wallace coefficients. Results: Clusters of species generated from MALDI-TOF MS showed good agreement of phylotypes generated with WGS. Pairs of strains that were > 94% similar to each other in terms of predicted amino acid sequences consistently showed cosine similarities of mass spectra > 0.65 and, of the 9 clusters identified with WGS, 8 were identical with MALDI-TOF. This corresponds to an adjusted Rand index of 0.95 and a 95% confidence interval of 0.80 – 1.00 for adjusted Wallace coefficients. The only discordance was for a pair of isolates that were classified as Paenibacillus species. This pair showed relatively high similarity (0.84) in terms of MALDI-TOF MS but only 85% similarity in terms of AAI. Conclusion: This study shows that MALDI-TOF and WGS exhibit a similar ability to delineate Bacillus species isolated from cleanrooms and taxonomic units described by these two methods are consistent with one another. Since MALDI-TOF MS is low in cost and high in throughput, this approach appears to be an ideal option for routine microbial monitoring and identifying Bacillus species.

Farnaz Mazhari↗

Application of Whole Genome Sequencing and MALDI-TOF to the Identifcation of Bacillus Species Isolated from Cleanrooms at NASA Johnson Space Center

Astromaterial cleanrooms at NASA Johnson Space Center are built environments that hold samples, such as lunar rocks, from different space exploration missions. Bacillus sp. are frequently detected in routine microbial monitoring of these facilities. Since this, and related genera, can form endospores that can withstand harsh conditions, they could contaminate astromaterials. This could confound searches for extraterrestrial life. Whole genome sequencing (WGS) is widely used for identifying bacterial strains and tracking their source; however, WGS is expensive and time consuming. Matrix-assisted laser desorption ionization– time of flight mass spectrometry (MALDI-TOF) shows promise as a low-cost, rapid method of identifying strains of bacteria, but few studies have compared this proteomics method to WGS. To evaluate a high throughput method of tracking the source of contamination of this built environment, WGS and MALDI-TOF was conducted on 18 bacterial strains isolated from surfaces in astromaterials cleanrooms. WGS identified 14 Bacillus, 2 Paenibacillus, 1 Solibacillus and 1 Alcaligenes strains. These isolates showed similarity to strains commonly observed in spacecraft assembly cleanrooms at other facilities. Cluster analysis of mass spectra generated by MALDI-TOF grouped strains together that were greater than 94% similar to each other in terms of amino acid sequences of single copy core genes, as assessed by WGS. This suggests that MALDI-TOF and WGS results are consistent with each other and MALDI-TOF can rapidly identify strains of Bacillus sp. isolated from cleanroom environments with a resolution comparable to WGS. Based on phylogenomic analysis, these results also suggest the presence of a cosmopolitan class of Bacillus sp. that are more likely to be found in cleanrooms and similar built environments than in natural systems.

Farnaz Mazhari↗