Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time resolved X-ray spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Imaging nanoscale carrier, thermal, and structural dynamics with time-resolved and ultrafast electron energy-loss spectroscopy

Time-resolved and ultrafast electron energy-loss spectroscopy (EELS) is an emerging technique for measuring photoexcited carriers, lattice dynamics, and near-fields across femtosecond to microsecond timescales. When performed in either a specialized scanning transmission electron microscope or ultrafast electron microscope (UEM), time-resolved and ultrafast EELS can directly image charge carriers, lattice vibrations, and heat dissipation following photoexcitation or applied bias. Yet, recent advances in theoretical calculations and electron optics are often required to realize the full potential of ultrafast EEL spectrum imaging. Here, in this review, we present a comprehensive overview of the recent progress in the theory and instrumentation of time-resolved and ultrafast EELS. We begin with an introduction to the technique, followed by a physical description of the loss function. We outline approaches for calculating and interpreting ground-state and transient EEL spectra spanning low-loss plasmons to core-level excitations analogous to x-ray absorption. We then survey the current state of time-resolved and ultrafast EELS techniques beyond photon-induced near-field electron microscopy, highlighting abilities to image carrier and thermal dynamics. Finally, we examine future directions enabled by emerging technologies, including electron beam monochromation, in situ and operando cells, laser-free UEM, and high-speed direct electron detectors. These advances position time-resolved and ultrafast EELS as a critical tool for uncovering nanoscale dynamic processes in quantum materials and solar energy conversion devices.

Computational methods↗

In-orbit operation of Resolve Filter Wheel and modulated X-ray source

The Resolve soft X-ray spectrometer is a high spectral resolution microcalorimeter spectrometer for the X-ray Imaging and Spectroscopy Mission. In the beam of Resolve, there is a filter wheel containing X-ray filters. In the beam, there is also an active calibration source, the modulated X-ray source (MXS), which can provide pulsed X-rays to facilitate gain calibration. The filter wheel consists of six filter positions. Two open positions, one 55 Fe source to aid in spectrometer characterization during the commissioning phase, and three transmission filters: a neutral density filter, an optical blocking filter, and a beryllium filter. The X-ray intensity, pulse period, and pulse separation of an MXS are highly configurable. Furthermore, the switch-on time is synchronized with the spacecraft’s internal clock to give accurate start and end times of the pulses. One of the issues raised during ground testing was the susceptibility of an MXS at high voltage to ambient light. Although measures were taken to mitigate the light leak, the efficacy of those measures must be verified in orbit. Along with an overview of issues raised during ground testing, we will discuss the calibration source and the filter performance in-flight and compare with the transmission curves present in the Resolve calibration database.

X-ray Imaging and Spectroscopy Mission/Resolve↗

In-orbit performance of the soft X-ray imaging telescope Xtend aboard XRISM

Here, we present a summary of the in-orbit performance of the soft X-ray imaging telescope Xtend onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), based on in-flight observation data, including first-light celestial objects, calibration sources, and results from the cross-calibration campaign with other currently operating X-ray observatories. XRISM/Xtend has a large field of view of ${38{^{\prime }_{.}}5}$ $\times$ ${38{^{\prime }_{.}}5}$, covering an energy range of 0.4–13 keV, as demonstrated by the first-light observation of the galaxy cluster Abell 2319. It also features an energy resolution of 170–180 eV at 6 keV, which meets the mission requirement and enables us to resolve He-like and H-like Fe K$\alpha$ lines. Throughout the observation during the performance verification phase, we confirm that two issues identified in the Soft X-ray Imager (SXI) onboard the previous Hitomi mission—light leakage and crosstalk events—are addressed and suppressed in the case of Xtend. A joint cross-calibration observation of the bright quasar 3C 273 results in an effective area measured to be $\sim$420 cm$^{2}$ at1.5 keV and $\sim$310 cm$^{2}$ at 6.0 keV, which matches values obtained in ground tests. We also continuously monitor the health of Xtend by analyzing overclocking data, calibration source spectra, and day-Earth observations; the readout noise is stable and low, and contamination is negligible even one year after launch. A low background level compared with other major X-ray instruments onboard satellites, combined with the largest grasp ($\Omega _{\rm eff}\sim 60$ cm$^2$ deg$^2$) of Xtend, will not only support Resolve analysis, but also enable significant scientific results on its own. This includes near-future follow-up observations and transient searches in the context of time-domain and multi-messenger astrophysics.

instrumentation: detectors: Xtend↗

Super-resolution stimulated X-ray Raman spectroscopy

Propagation of intense X-ray pulses through dense media has led to the observation of phenomena such as atomic X-ray lasing, self-induced transparency and stimulated X-ray Raman scattering (SXRS)4. SXRS has been long predicted as a means to launch and probe valence-electron wavepackets and as a building block for nonlinear X-ray spectroscopies. However, experimental observations of SXRS to date have not provided spectroscopic information, and theoretical modelling has largely implemented hard-to-realize phase-coherent attosecond pulses. Here we demonstrate SXRS with spectroscopic precision, that is, detection of valence-excited states in neon with a near Fourier-limited joint energy–time resolution of 0.1 eV–40 fs. We used a new covariance analysis between statistically spiky broadband incident X-ray and scattered X-ray Raman pulses. Using 18,000 single shots, we beat not only the incident (about 8 eV) bandwidth but also the approximately 0.2 eV instrumental energy resolution, thus creating super-resolution conditions, in analogy to super-resolved fluorescence microscopy. Our experimental results, supported by ab initio propagation simulations, reveal the competition between lasing in the ion and stimulated Raman scattering in the neutral. We demonstrate enhanced signal collection efficiency and a broad excitation window, surpassing spontaneous Raman efficiencies by orders of magnitude. This stochastic SXRS approach represents a first step towards tracking elementary events that determine chemical outcomes.

nonlinear x-ray spectroscopy↗

Revealing Parallel Inter‐ and Intra‐Ligand Charge Transfer Dynamics in [Ru(L) 2 (dppz)] 2+ Molecular Lightswitch with N K‐Edge X‐Ray Absorption Spectroscopy

In photoactive metal complexes the localization of photoexcited charges dictates the site of chemical reactivity, but few studies measure the charge redistribution in these systems with spatial precision. Herein, we track the inter- and intra-ligand charge transfer processes that underpin light-driven charge separation in the well-studied “molecular lightswitch” [Ru(bpy) 2 dppz] 2+ (aqueous [Ruthenium II (2,2′-bipyridine)2(dipyrido[3,2-a:2′,3′-c]phenazine)] 2+ [Cl − ] 2 ) by probing the electronic structure of ligand nitrogen atoms in real-time using ultrafast X-ray absorption spectroscopy and first principles calculations. We confirm the localization of excited electron density on the phenazine N atoms of dppz and we newly identify two parallel electron transfer pathways to populate this state. Sub-70 fs electron transfer to the phenazine portion of dppz is observed and attributed to intra-ligand electron transfer following Ru-to-dppz metal-to-ligand charge transfer (MLCT) excitation. This fast charge transfer was not reported in prior ultrafast studies. The slower (ca. 2 ps) charge transfer reported extensively in time-resolved optical absorption and emission studies is reassigned here to inter-ligand electron “hopping” between nearly isoenergetic ligand moieties following Ru-to-bpy MLCT excitation. In conclusion, the results demonstrate much faster charge separation than previously identified in this well-studied system, highlighting how extended azaacene ligand motifs promote the competitive charge transfer processes needed to drive light-driven electron transfer chemistry.

Donor-acceptor systems↗

Structured ionized winds shooting out from a quasar at relativistic speeds

Evidence indicates that supermassive black holes (SMBHs) exist at the centres of most galaxies. Their mass correlates with the galactic bulge mass, suggesting a coevolution with their host galaxies, most likely through powerful winds. X-ray observations have detected highly ionized winds outflowing at sub-relativistic speeds from the accretion disks around SMBHs. However, the limited spectral resolution of present X-ray instruments has left the physical structure and location of the winds poorly understood, hindering accurate estimates of their kinetic power. Here, in this study, the first X-Ray Imaging and Spectroscopy Mission (XRISM) observation of the luminous quasar PDS 456 is reported. The high-resolution spectrometer Resolve aboard XRISM enabled the discovery of five discrete velocity components outflowing at 20–30% of the speed of light. This demonstrates that the wind structure is highly inhomogeneous, which probably consists of up to a million clumps. The mass outflow rate is estimated to be 60–300 solar masses per year, with the wind kinetic power exceeding the Eddington luminosity limit. Compared with the galaxy-scale outflows, the kinetic power is more than three orders of magnitude larger, whereas the momentum flux is ten times larger. These estimates disfavour both energy-driven and momentum-driven outflow models. This suggests that such wind activity occurs in less than 10% of the quasar phase and/or that its energy/momentum is not efficiently transferred to the galaxy-scale outflows owing to the clumpiness of the wind and the interstellar medium.

Audard, Marc [Univ. of Geneva, Versoix (Switzerlan↗

Ultrafast Relaxation of MLCT Excited States in Manganese Tricarbonyl Complexes: Insights from Polarization-Resolved Femtosecond X-ray Absorption Spectroscopy at the Mn and Br K-Edges

Optical absorption features that are often described as metal-to-ligand charge transfer (MLCT) bands underlie the utility of many metal coordination complexes by harnessing the energy of light to drive otherwise inaccessible chemical reactions. Excitation of these bands triggers rapid electronic dynamics that can be challenging to understand, due to complicated potential energy landscapes and highly correlated electronic and nuclear degrees of freedom in metal-containing compounds. The lowest-energy absorption bands in Mn complexes containing alpha-diimine, carbonyl, and halide ligands are particularly interesting, due to the delocalized nature of charge transfer upon excitation. Here, in this study, we report experimental ultrafast dynamics measurements for the series of compounds Mn­(CO) 3 ( R bpy)Br ( R bpy = 4,4′-disubstituted-2,2′-bipyridine; R = H, CF 3 , or NO 2 ) using polarization-resolved, femtosecond X-ray absorption spectroscopy (XAS) at both the Mn and Br K edges. The appearance of a new absorption feature in the Br pre-edge spectrum upon optical excitation reveals the instantaneous formation of an electronic hole that is partially localized on the Br atom and has a lifetime that depends on the electron withdrawing character of the R bpy ligand. For two of the complexes (R = H or CF 3 ), a large expansion of the Mn–Br distance results in a rapid redistribution of the hole and a corresponding decrease in anisotropy of the absorption feature within 50 fs, after which the absorption into the hole disappears on a time scale shorter than 300 fs. We observe a different result for the NO 2 substituted compound, for which the Mn–Br bond contracts and the absorption into the Br-centered hole persists beyond the 2 ps time scale of our measurement. The Mn pre-edge spectrum also reveals structural changes for these three complexes, but the new Mn absorption features become evident only after the nuclei respond to the initial excitation, which allows mixing of Mn 3d and 4p orbitals. The combined use of ultrafast Mn and Br K-edge spectroscopy provides unique insight into the ways in which bipyridine substitution alters the excited-state dynamics, including a very different structural response for the most strongly electron withdrawing substituent.

Otolski, Christopher J. [Univ. of Kansas, Lawrence↗

Data for "Gold-Induced Chemical Perturbations in CdTe-Based Photovoltaic Cells"

Back contacting p-type CdTe has been identified as one of the major areas of loss in CdTe photovoltaic (PV) power conversion efficiency (PCE). In research settings, Au is a common contact material due to its ease of use and decent performance. This work provides a detailed investigation into using gold for back contacting As-doped, CdCl2 treated, polycrystalline CdTe that has been exposed to air after absorber processing, another routine practice. First, X-ray photoemission spectroscopy (XPS) is used to determine the native oxide to be 1.6 nm of CdTeO3 using a combination of angle-resolved XPS and the cadmium modified Auger parameter. During gold metallization of CdTe, oxygen and oxidized tellurium are eliminated from the thin CdTeO3 native oxide. The fate of the released oxygen and possibly cadmium and tellurium are not known, but these reaction byproducts can enter the absorber bulk or grain boundaries, stay at the interface, or dissolve in the Au. Interfacial hole barriers between CdTe and Au are measured for samples with and without the native oxide present prior to metallization. Results show that the thin CdTeO3 alleviates the downward band bending by 40 meV from 470 meV to 430 meV even though it is consumed during interface formation. The implications of these chemical reactions on the device are assessed through photoluminescence (PL) spectroscopy which shows losses in internal open circuit voltage (iVoc) from 820 meV to 795 meV, carrier lifetime from 123 ns to 45 ns, and PL quantum yield from 2.9x10-5 to 1.2x10-5. Modeling time-resolved PL lifetimes demonstrates the back surface recombination velocity due to metallization reduces minority carrier lifetimes. These results identify the native oxide and show that it plays an important role in mediating downward band bending along with how the back interface reaction can negatively impact device-scale parameters and reduce PV PCE.

14 SOLAR ENERGY↗

Thermal and kinematic properties of ejecta in SN1987A revealed by XRISM

We present an analysis of high-resolution spectra from the shock-heated plasmas in SN 1987A, based on an observation using the Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission (XRISM). The 1.7–10 keV Resolve spectra are accurately represented by a single-component, plane-parallel shock plasma model, with a temperature of $2.84_{-0.08}^{+0.09}$ keV and an ionization parameter of $2.64_{-0.45}^{+0.58}$ × $10^{11}\,\,{\rm s\,\, cm}^{-3}$. The Resolve spectra are also well reproduced by the 3D magneto-hydrodynamic simulation presented by Orlando et al. (2020, A&A, 636, A22) suggesting substantial contribution from the ejecta. The metal abundances obtained with Resolve align with the Large Magellanic Cloud value, indicating that the X-rays in 2024 originate from “non-metal-rich” shock-heated ejecta and the reverse shock has not reached the inner metal-rich region of ejecta. Doppler widths of the atomic lines from Si, S, and Fe correspond to velocities of 1500–1700 km s$^{-1}$, where the thermal broadening effects in this non-metal-rich plasma are negligible. Therefore, the line broadening seen in Resolve spectra is determined by the large bulk motion of ejecta. For reference, we determined a $90\%$ upper limit on non-thermal emission from a pulsar wind nebula at $4.3 \times 10^{-13}$ erg cm$^{-2}$ s$^{-1}$ in the 2–10 keV range, aligning with NuSTAR findings by Greco et al. (2022, ApJ, 931, 132). Additionally, we searched for the $^{44}$Sc K line feature and found a $1\sigma$ upper limit of $1.0 \times 10^{-6}$ photons cm$^{-2}$ s$^{-1}$, which translates to an initial $^{44}$Ti mass of approximately $2 \times 10^{-4}\, M_{\odot }$, consistent with previous X-ray to soft gamma-ray observations (Boggs et al. 2015, Science, 348, 670; Grebenev et al. 2012, Nature, 490, 373; Leising 2006, ApJ, 651, 1019).

ISM: supernova remnants↗

XRISM high-resolution X-ray spectroscopy of Cygnus X-1: Highly ionized iron absorption structures

We present the first high-resolution X-ray spectral analysis of Cygnus X-1 using XRISM. The observation wa3s carried out from 2024 April 7 to 10, covering the orbital phase range 0.65–0.17 during its low/hard state. Taking advantage of the exceptional energy resolution of the Resolve instrument, we examined highly ionized iron absorption lines and characterized the ionization states, column densities, and line-of-sight velocities of the absorbing plasma. Spectral analysis revealed an ionization parameter of $\xi \sim 3$, column densities of a few $\times 10^{21}$ cm$^{-2}$, and a blueshifted velocity of $\sim$100 km s$^{-1}$. The observation was divided into two phases: before and after orbital phase $\phi _{\rm {orb}} = 0.9$, corresponding to non-dipping and dipping intervals. While only weak absorption features were present before $\phi _{\rm {orb}} = 0.9$, strong absorption by He-like and H-like Fe appeared during the dipping phase. We measured equivalent widths of 2.3, 0.4, and 1.2 eV for He-like Fe K$\alpha$ and H-like Ly$\alpha _1$ and Ly$\alpha _2$, respectively—demonstrating the capability of XRISM Resolve to securely detect narrow absorption features of only a few eV. These measurements trace the motion of the absorbing material and offer insight into the kinematics and spatial distribution of the wind in the vicinity of the black hole. These findings enhance our understanding of wind-fed accretion in Cygnus X-1 and highlight the importance of continued high-resolution X-ray observations to further constrain the physical properties of winds and accretion flows in high-mass X-ray binaries.

Astronomy and AstroPhysics↗

Giant Electrostriction via Nanodomain Engineering in Relaxor Ferroelectric Polymers

Relaxor ferroelectric (RFE) polymers hold great promise for artificial muscles due to their high actuation strain, high loading stress, and fast response. However, the structural origin underlying their large electrostrictive deformation remains elusive. In this study, we investigate poly(vinylidene fluoride-co-trifluoroethylene) [P(VDF-TrFE)]-based RFE terpolymers, incorporating 1,1-chlorofluoroethylene (CFE) or chlorotrifluoroethylene (CTFE) (the terpolymers are denoted as terP-CFE and terP-CTFE, respectively) as termonomers. Although both terpolymers show similar semicrystalline morphology, drastically different electrostrictive properties are observed. Specifically, the terP-CFE annealed at 100 °C achieves a record-high transverse strain of ∼10.6%, whereas 100 °C-annealed terP-CTFE only shows a much lower actuation strain of ∼4.2% at the same poling field of 190 MV/m. To elucidate the origin of this difference, time-resolved wide-angle X-ray diffraction, small-angle X-ray scattering, and Fourier transform infrared experiments are performed during in situ electric poling. An RFE-to-ferroelectric (FE) crystal phase transition is observed for terP-CFE but is absent for terP-CTFE. Beyond the contribution of the crystalline phase, the oriented amorphous fraction and crystalline defects (e.g., taut-tie molecules) also play significant roles in enhancing electrostriction. In conclusion, this mechanistic insight provides a valuable foundation for the rational design of next-generation RFE polymers with tunable properties through defect engineering of their semicrystalline structures.

36 MATERIALS SCIENCE↗

Ultrafast Terahertz Field Control of the Emergent Magnetic and Electronic Interactions at Oxide Interfaces

Ultrafast electric-field control of emergent electronic and magnetic states at oxide interfaces offers exciting prospects for the development of the next generation of energy-efficient devices. Here, it is demonstrated that the electronic structure and emergent ferromagnetic interfacial state in epitaxial LaNiO3/CaMnO3 superlattices can be effectively controlled using intense, single-cycle THz electric-field pulses. A suite of advanced X-ray spectroscopic techniques is employed to measure a detailed magneto-optical profile and the thickness of the ferromagnetic interfacial layer. Then, a combination of time-resolved and temperature-dependent optical measurements is used to disentangle several correlated electronic and magnetic processes driven by ultrafast, high-field THz pulses. Sub-picosecond non-equilibrium Joule heating of the electronic system is observed, ultrafast demagnetization of the ferromagnetic interfacial layer, and slower dynamics indicative of a change in the magnetic state of the superlattice due to the transfer of spin-angular momentum to the lattice. These findings suggest a promising avenue for the efficient control of 2D ferromagnetic states at oxide interfaces using ultrafast electric-field pulses.

X-ray spectroscopy and scattering↗

Gold L-shell emission spectroscopy as a temperature diagnostic in laser-driven experiments

Measurements of plasma conditions within gold hohlraums are challenging but provide important information about hohlraum energy transport. To date, there are no reliable passive diagnostic approaches that produce information about the hohlraum plasma conditions. Gold L-shell emission spectroscopy is a promising method to measure the electron temperature in multi-keV gold hohlraum plasmas. In this study, we compare time-resolved measurements of gold L-shell spectra against a more conventional electron temperature-sensitive diagnostic, K-shell emission from zinc, a mid-Z dopant. The Au L-shell and Zn K-shell spectra are taken simultaneously. The analysis of both sets of data exhibits good agreement with a singular rad-hydro model, suggesting a similar evolution in the mean electron temperature of the hohlraum plasma. These findings support the use of L-shell spectroscopy of gold as a method to study gold plasma conditions.

Emission spectroscopy↗

Reconciling the Different Apparent Decay Pathways for Iron(III) Tetraphenylporphyrin Chloride: Evidence for Excited State Branching

Detailed understanding of the photophysical properties of metalloporphyrins is key to rationally exploiting them in a variety of applications ranging from photocatalysis to opto-magnetics. Previous studies of the ferric-tetraphenylporphyrin chloride have provided contradictory descriptions of the excited state evolution. Optical transient-absorption suggested initial formation of a ππ* excited state, followed by ligand-to-metal charge-transfer (LMCT) from the porphyrin ring and then decay on the ∼2 ps time scale to a metal-centered excited state that had a lifetime of ∼15 ps. In contrast, femtosecond extreme ultraviolet transient-absorption at the Fe M 2,3 -edge, while agreeing on the initial formation of an LMCT state, found evidence that this decayed in ∼2 ps to the ground state. Here, we have used K-edge transient X-ray absorption and X-ray emission, together with time-resolved X-ray solution scattering to explore this system. Based on these data, we propose a new model, consistent with both the earlier and the current data, in which photoexcited FeTPPCl evolves through three different states on the LMCT manifold, with the ∼2 ps decay now seen to involve a branching between return to the ground state (∼70%) and formation of a long-lived LMCT state (∼30%).

Excited states↗

Resolving discrepancies in bang-time predictions for indirect-drive ICF experiments on the NIF: Insights from the Build-A-Hohlraum campaign

This study investigated discrepancies between measured and simulated x-ray drive in Indirect-Drive Inertial Confinement Fusion (ID-ICF) hohlraums at the National Ignition Facility. Despite advances in radiation-hydrodynamic simulations, a consistent “drive deficit” remains. Experimentally measured ID-ICF capsule bang-times are systematically 400–700 ps later than simulations predict. The Build-A-Hohlraum (BAH) campaign explored potential causes for this discrepancy by systematically varying hohlraum features, including laser entrance hole (LEH) windows, capsules, and gas fills. Overall, the agreement between simulated and experimental x-ray drive was found to be largely unaffected by these changes. The data allow us to exclude some hypotheses put forward to potentially explain the discrepancy. Errors in the local thermodynamic equilibrium (LTE) atomic modeling, errors in the modeling of LEH closure, and errors due to a lack of plasma species mix physics in simulations are shown to be inconsistent with our measurements. Instead, the data support the hypothesis that errors in NLTE emission modeling are a significant contributor to the discrepancy. X-ray emission in the 2–4 keV range is found to be approximately 30% lower than in simulations. This is accompanied by higher than predicted electron temperatures in the gold bubble region, pointing to errors in non-LTE modeling. Introducing an opacity multiplier of 0.87 on energy groups above 1.8 keV improves agreement with experimental data, reducing the bang-time discrepancy from 300 to 100 ps. These results underscore the need for refined NLTE opacity models to enhance the predictive power of hohlraum simulations.

Band emission↗

Electron–Ion Covariance Reveals Geometry-Resolved Inner-Shell Spectra in CS 2 Photodissociation

The chemical shifts of inner-shell atomic orbitals are highly sensitive to chemical bonding and molecular structure. In evolving systems, however, the spectra of distinct molecular species and geometries overlap, obscuring the underlying chemical dynamics. Here we demonstrate the use of electron–ion covariance analysis to combine the structural sensitivity of Coulomb explosion imaging with inner-shell spectroscopy, yielding geometry-specific spectra of transient and product species. We apply this approach to the excited state dynamics of CS 2 probed by ionization above the S 2p edge. Electron–ion covariance with time- and momentum-selected S + and S 2+ ions isolates distinct S 2p photoelectron spectra for ground-state CS 2 , bent photoexcited CS 2 , the CS photoproduct, and bare atomic sulfur ─ species whose spectra overlap strongly in the channel-averaged measurement. Clear chemical shifts are observed in the covariance photoelectron spectrum for each of these species, all of which are consistent with high-level calculations. Here, by extracting the atomic S contribution to the photoelectron spectrum in a finely time-resolved manner we can disentangle this contribution to the overall time-resolved photoelectron spectrum as the photodissociation proceeds. These results demonstrate the promise of electron–ion covariance as a general approach to geometry-resolved inner-shell spectroscopy, opening a route to tracking structural evolution through chemical shifts in complex photoexcited molecules.

Ionization↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Electrolyte Vapor Induced Passivation and Transition Metal Redox on Electrode Active Materials

The gaseous environment that battery electrodes are exposed to is critical to their electrochemical performance, and yet, the impact of vapor-phase components in the glovebox is relatively unexplored. In this study, we examine how the surface of Li 4 Ti 5 O 12 and LiFePO 4 composite electrodes evolve upon exposure to 1 M LiPF 6 in ethylene carbonate:dimethyl carbonate electrolyte vapors in an argon-filled glovebox. Spatially resolved X-ray photoemission electron microscopy and X-ray photoelectron spectroscopy reveal that even brief (15 minutes) contact with electrolyte vapor initiates the formation of a LiF film and changes the oxidation state of transition metals at the particle surface. Notably, these modifications occur selectively on active material particles and not on binder or conductive carbon, underscoring the specificity of vapor-induced reactions. Prolonged exposure to electrolyte vapor over the course of 1 week yields thicker, more chemically complex interphases containing both LiF and lithium oxyfluorophosphate species (Li x PO y F z ). Subsequent electrochemical testing shows that vapor-induced passivation layers influence first cycle capacities, lithium (de)insertion overpotentials, and charge-transfer resistance values. In conclusion, these results indicate that vapor–electrode interactions may be a source of variability in electrochemical behavior over time and suggest that other, more reactive electrode materials may also be susceptible to interactions with electrolyte vapor.