Search NASA⌕ Search

SEARCH · Search NASA

Results for “Total variation regularization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Effective noise-suppressed and artifact-reduced reconstruction of SPECT data using a preconditioned alternating projection algorithm

Purpose: The authors have recently developed a preconditioned alternating projection algorithm (PAPA) with total variation (TV) regularizer for solving the penalized-likelihood optimization model for single-photon emission computed tomography (SPECT) reconstruction. This algorithm belongs to a novel class of fixed-point proximity methods. The goal of this work is to investigate how PAPA performs while dealing with realistic noisy SPECT data, to compare its performance with more conventional methods, and to address issues with TV artifacts by proposing a novel form of the algorithm invoking high-order TV regularization, denoted as HOTV-PAPA, which has been explored and studied extensively in the present work. Methods: Using Monte Carlo methods, the authors simulate noisy SPECT data from two water cylinders; one contains lumpy “warm” background and “hot” lesions of various sizes with Gaussian activity distribution, and the other is a reference cylinder without hot lesions. The authors study the performance of HOTV-PAPA and compare it with PAPA using first-order TV regularization (TV-PAPA), the Panin–Zeng–Gullberg one-step-late method with TV regularization (TV-OSL), and an expectation–maximization algorithm with Gaussian postfilter (GPF-EM). The authors select penalty-weights (hyperparameters) by qualitatively balancing the trade-off between resolution and image noise separately for TV-PAPA and TV-OSL. However, the authors arrived at the same penalty-weight value for both of them. The authors set the first penalty-weight in HOTV-PAPA equal to the optimal penalty-weight found for TV-PAPA. The second penalty-weight needed for HOTV-PAPA is tuned by balancing resolution and the severity of staircase artifacts. The authors adjust the Gaussian postfilter to approximately match the local point spread function of GPF-EM and HOTV-PAPA. The authors examine hot lesion detectability, study local spatial resolution, analyze background noise properties, estimate mean square errors (MSEs), and report the convergence speed and computation time. Results: HOTV-PAPA yields the best signal-to-noise ratio, followed by TV-PAPA and TV-OSL/GPF-EM. The local spatial resolution of HOTV-PAPA is somewhat worse than that of TV-PAPA and TV-OSL. Images reconstructed using HOTV-PAPA have the lowest local noise power spectrum (LNPS) amplitudes, followed by TV-PAPA, TV-OSL, and GPF-EM. The LNPS peak of GPF-EM is shifted toward higher spatial frequencies than those for the three other methods. The PAPA-type methods exhibit much lower ensemble noise, ensemble voxel variance, and image roughness. HOTV-PAPA performs best in these categories. Whereas images reconstructed using both TV-PAPA and TV-OSL are degraded by severe staircase artifacts; HOTV-PAPA substantially reduces such artifacts. It also converges faster than the other three methods and exhibits the lowest overall reconstruction error level, as measured by MSE. Conclusions: For high-noise simulated SPECT data, HOTV-PAPA outperforms TV-PAPA, GPF-EM, and TV-OSL in terms of hot lesion detectability, noise suppression, MSE, and computational efficiency. Unlike TV-PAPA and TV-OSL, HOTV-PAPA does not create sizable staircase artifacts. Moreover, HOTV-PAPA effectively suppresses noise, with only limited loss of local spatial resolution. Of the four methods, HOTV-PAPA shows the best lesion detectability, thanks to its superior noise suppression. HOTV-PAPA shows promise for clinically useful reconstructions of low-dose SPECT data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of the OSC-TV iterative reconstruction algorithm for cone-beam optical CT

Purpose: The present work evaluates an iterative reconstruction approach, namely, the ordered subsets convex (OSC) algorithm with regularization via total variation (TV) minimization in the field of cone-beam optical computed tomography (optical CT). One of the uses of optical CT is gel-based 3D dosimetry for radiation therapy, where it is employed to map dose distributions in radiosensitive gels. Model-based iterative reconstruction may improve optical CT image quality and contribute to a wider use of optical CT in clinical gel dosimetry. Methods: This algorithm was evaluated using experimental data acquired by a cone-beam optical CT system, as well as complementary numerical simulations. A fast GPU implementation of OSC-TV was used to achieve reconstruction times comparable to those of conventional filtered backprojection. Images obtained via OSC-TV were compared with the corresponding filtered backprojections. Spatial resolution and uniformity phantoms were scanned and respective reconstructions were subject to evaluation of the modulation transfer function, image uniformity, and accuracy. The artifacts due to refraction and total signal loss from opaque objects were also studied. Results: The cone-beam optical CT data reconstructions showed that OSC-TV outperforms filtered backprojection in terms of image quality, thanks to a model-based simulation of the photon attenuation process. It was shown to significantly improve the image spatial resolution and reduce image noise. The accuracy of the estimation of linear attenuation coefficients remained similar to that obtained via filtered backprojection. Certain image artifacts due to opaque objects were reduced. Nevertheless, the common artifact due to the gel container walls could not be eliminated. Conclusions: The use of iterative reconstruction improves cone-beam optical CT image quality in many ways. The comparisons between OSC-TV and filtered backprojection presented in this paper demonstrate that OSC-TV can potentially improve the rendering of spatial features and reduce cone-beam optical CT artifacts.

60 APPLIED LIFE SCIENCES↗

Binary Control Pulse Optimization for Quantum Systems

Quantum control aims to manipulate quantum systems toward specific quantum states or desired operations. Designing highly accurate and effective control steps is vitally important to various quantum applications, including energy minimization and circuit compilation. In this paper we focus on discrete binary quantum control problems and apply different optimization algorithms and techniques to improve computational efficiency and solution quality. Specifically, we develop a generic model and extend it in several ways. We introduce a squared L 2 -penalty function to handle additional side constraints, to model requirements such as allowing at most one control to be active. We introduce a total variation (TV) regularizer to reduce the number of switches in the control. We modify the popular gradient ascent pulse engineering (GRAPE) algorithm, develop a new alternating direction method of multipliers (ADMM) algorithm to solve the continuous relaxation of the penalized model, and then apply rounding techniques to obtain binary control solutions. We propose a modified trust-region method to further improve the solutions. Our algorithms can obtain high-quality control results, as demonstrated by numerical studies on diverse quantum control examples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Seismic Monitoring at the Farnsworth CO2-EOR Field Using Time-Lapse Elastic-Waveform Inversion of 3D-3C VSP Data

During the Development Phase of the U.S. Southwest Regional Partnership on Carbon Sequestration, supercritical CO2 was continuously injected into the deep oil-bearing Morrow B formation of the Farnsworth Unit in Texas for Enhanced Oil Recovery (EOR). The project injected approximately 94 kilotons of CO2 to study geologic carbon storage during CO2-EOR. A three-dimensional (3D) surface seismic dataset was acquired in 2013 to characterize the subsurface structures of the Farnsworth site. Following this data acquisition, the baseline and three time-lapse three-dimensional three-component (3D-3C) vertical seismic profiling (VSP) data were acquired at a narrower surface area surrounding the CO2 injection and oil/gas production wells between 2014 and 2017 for monitoring CO2 injection and migration. With these VSP datasets, we inverted for subsurface velocity models to quantitatively monitor the CO2 plume within the Morrow B formation. We first built 1D initial P-wave (Vp) and S-wave (Vs) velocity models by upscaling the sonic logs. We improved the deep region of the Vp and Vs models by incorporating the deep part of a migration velocity model derived from the 3D surface seismic data. We improved the shallow region of 3D Vp and Vs models using 3D traveltime tomography of first arrivals of VSP downgoing waves. We further improved the 3D baseline velocity models using elastic-waveform inversion (EWI) of the 3D baseline VSP upgoing data. Our advanced EWI method employs alternative tomographic and conventional gradients and total-variation-based regularization to ensure the high-fidelity updates of the 3D baseline Vp and Vs models. We then sequentially applied our 3D EWI method to the three time-lapse datasets to invert for spatiotemporal changes of Vp and Vs in the reservoir. Our inversion results reveal the volumetric changes of the time-lapse Vp and Vs models and show the evolution of the CO2 plume from the CO2 injection well to the oil/gas production wells.

42 ENGINEERING↗

Total Variation Majorization Minimization (TV-MM) Approach to Radiometer Brightness Temperature Gridding and Reconstruction

This paper presents the implementation of an algorithm to enhance the image resolution of the Earth's surface brightness temperature (T B ) data measured by radiometers such as the one onboard of the Soil Moisture Active Passive (SMAP) mission. A key step in radiometer T B processing is the conversion of the swath-based calibrated antenna temperature (T A ) measurements to the Level 3 Earth-centered grid. The simplest algorithm to transform this data from swath to gridded format is called drop-in-the-bucket which simply averages surrounding noisy T A samples to form a T B value at the gridded location. This method reduces noise, however produces low resolution products. To obtain a higher resolution product, SMAP uses other techniques such the Backus-Gilbert (BG) algorithm, which is the conventional method used in microwave radiometry. Although this method performs the required interpolation, it is not effective in denoising and removing blurring effects due to antenna filtering of the radiometer image data. Our motivation for this development is to further improve the resolution through post-processing of the radiometer T B image, a highly cost-effective method of image enhancement. The approach adapted in this work is based on the minimization of the Total Variation (TV) regularized objective function that is used extensively in solving general ill-posed linear inverse problems in image processing. Since the TV-based objective function is convex but not everywhere differentiable, there exists many numerical algorithms that can estimate the solution and the one selected for this work is called Majorization- Minimization (MM). By applying this algorithm, simulation experiments were performed based on synthetic data from the Geophysical model as well as real SMAP data to demonstrate the effectiveness of the technique. Results were then compared against the BG method.

Wing Lee↗

3D and 4D magnetic susceptibility tomography based on complex MR images

Magnetic susceptibility is the physical property for T2*-weighted magnetic resonance imaging (T2*MRI). The invention relates to methods for reconstructing an internal distribution (3D map) of magnetic susceptibility values, .chi. (x,y,z), of an object, from 3D T2*MRI phase images, by using Computed Inverse Magnetic Resonance Imaging (CIMRI) tomography. The CIMRI technique solves the inverse problem of the 3D convolution by executing a 3D Total Variation (TV) regularized iterative convolution scheme, using a split Bregman iteration algorithm. The reconstruction of .chi. (x,y,z) can be designed for low-pass, band-pass, and high-pass features by using a convolution kernel that is modified from the standard dipole kernel. Multiple reconstructions can be implemented in parallel, and averaging the reconstructions can suppress noise. 4D dynamic magnetic susceptibility tomography can be implemented by reconstructing a 3D susceptibility volume from a 3D phase volume by performing 3D CIMRI magnetic susceptibility tomography at each snapshot time.

47 OTHER INSTRUMENTATION↗

Nondestructive Evaluation of Concrete: Elastic Property Imaging Through Full-Waveform Inversion

Concrete is a vital material in construction—especially in the nuclear industry, where it is used in critical structures such as containment vessels. Over time, concrete can degrade due to harsh operational and environmental conditions, necessitating that its elastic properties be accurately evaluated to ensure structural integrity and safety. Traditional nondestructive evaluation methods such as ultrasound-based techniques often rely on simplifying assumptions that may not hold true for concrete. This paper presents an advanced ultrasound-based method that uses elastic full-waveform inversion (EFWI) to create detailed images of concrete’s mechanical properties. By accurately modeling wave behaviors such as scattering and reflection, we aim to overcome the limitations of conventional ultrasonic-based methods. In this work, the imaging problem involved reconstructing the various elastic properties of a heterogenous concrete block with three steel rebars embedded in it. The ultrasonic measurements were synthetically generated from multiple sources and receivers, and the reconstruction process was performed using a gradient-based optimization algorithm. Our approach leveraged EFWI to reconstruct high-resolution images of the pressure wave speed, shear wave speed, and density. Multiple misfit functions—including L2-norm, cross-correlation (CC), and L1-norm—combined with total variation (TV) regularization and parameter constraints using a Sigmoid function—were explored for the reconstruction. The results demonstrated that using the L1-norm misfit function in conjunction with TV regularization and Sigmoid constraints significantly improved the reconstruction quality in comparison to traditional methods. This approach provided clearer images with fewer artifacts and better captured background heterogeneity. Our findings highlight that, when properly designed, EFWI carries great potential for providing comprehensive, more accurate, and more reliable assessments of concrete conditions, as is crucial for the maintenance and safety of nuclear power plant structures.

97 - MATHEMATICS AND COMPUTING↗

SU-D-17A-03: 5D Respiratory Motion Model Based Iterative Reconstruction Method for 4D Cone-Beam CT

Purpose: The purpose of this work is to develop a new iterative reconstruction method for 4D cone-beam CT (CBCT) based on a published time-independent 5D respiratory motion model. The proposed method will offer a single high-resolution image at a user-selected breathing phase and the 5D motion model parameters, which could be used to generate the breathing pattern during the CT acquisition. Methods: 5D respiratory motion model was proposed for accurately modeling the motion of lung and lung tumor tissues. 4D images are then parameterized by a reference image, measured breathing amplitude, breathing rate, two time-independent vector fields that describe the 5D model parameters, and a scalar field that describes the change in HU as a function of breathing amplitude. In contrast with the traditional method of reconstructing multiple temporal image phases to reduce respiratory artifact, 5D model based method simplify the problem into the reconstruction of a single reference image and the 5D motion model parameters. The reconstruction formulation of the reference image and scalar and vector fields is a nonlinear least-square optimization problem that consists of solving the reference image and fields alternately, in which the reference image is regularized with the total variation sparsity transform and the vector fields are solved through linearizations regularized by the H1 norm. 2D lung simulations were performed in this proof-of-concept study. Results: The breathing amplitude, its rate, and the corresponding scalar and vector fields were generated from a patient case. Compared with filtered backprojection method and sparsity regularized iterative method for the phase-by-phase reconstruction, the proposed 5D motion model based method yielded improved image quality. Conclusion: Based on 5D respiratory motion model, we have developed a new iterative reconstruction method for 4D CBCT that has the potential for improving image quality while providing needed on-table motion information.

60 APPLIED LIFE SCIENCES↗

GPU-accelerated regularized iterative reconstruction for few-view cone beam CT

Purpose: The present work proposes an iterative reconstruction technique designed for x-ray transmission computed tomography (CT). The main objective is to provide a model-based solution to the cone-beam CT reconstruction problem, yielding accurate low-dose images via few-views acquisitions in clinically acceptable time frames. Methods: The proposed technique combines a modified ordered subsets convex (OSC) algorithm and the total variation minimization (TV) regularization technique and is called OSC-TV. The number of subsets of each OSC iteration follows a reduction pattern in order to ensure the best performance of the regularization method. Considering the high computational cost of the algorithm, it is implemented on a graphics processing unit, using parallelization to accelerate computations. Results: The reconstructions were performed on computer-simulated as well as human pelvic cone-beam CT projection data and image quality was assessed. In terms of convergence and image quality, OSC-TV performs well in reconstruction of low-dose cone-beam CT data obtained via a few-view acquisition protocol. It compares favorably to the few-view TV-regularized projections onto convex sets (POCS-TV) algorithm. It also appears to be a viable alternative to full-dataset filtered backprojection. Execution times are of 1–2 min and are compatible with the typical clinical workflow for nonreal-time applications. Conclusions: Considering the image quality and execution times, this method may be useful for reconstruction of low-dose clinical acquisitions. It may be of particular benefit to patients who undergo multiple acquisitions by reducing the overall imaging radiation dose and associated risks.

60 APPLIED LIFE SCIENCES↗

A comparative study of structural similarity and regularization for joint inverse problems governed by PDEs

Joint inversion refers to the simultaneous inference of multiple parameter fields from observations of systems governed by single or multiple forward models. In many cases these parameter fields reflect different attributes of a single medium and are thus spatially correlated or structurally similar. By imposing prior information on their spatial correlations via a joint regularization term, we seek to improve the reconstruction of the parameter fields relative to inversion for each field independently. One of the main challenges is to devise a joint regularization functional that conveys the spatial correlations or structural similarity between the fields while at the same time permitting scalable and efficient solvers for the joint inverse problem. We describe several joint regularizations that are motivated by these goals: a cross-gradient and a normalized cross-gradient structural similarity term, the vectorial total variation, and a joint regularization based on the nuclear norm of the gradients. Based on numerical results from three classes of inverse problems with piecewise-homogeneous parameter fields, we conclude that the vectorial total variation functional is preferable to the other methods considered. Besides resulting in good reconstructions in all experiments, it allows for scalable, efficient solvers for joint inverse problems governed by PDE forward models.

97 MATHEMATICS AND COMPUTING↗

Enhanced detection of paramagnetic fluorine-19 magnetic resonance imaging agents using zero echo time sequence and compressed sensing

Fluorine-19 ( 19 F) magnetic resonance imaging (MRI) is an emerging technique offering specific detection of labeled cells in vivo. Lengthy acquisition times and modest signal-to-noise ratio (SNR) makes three-dimensional spin-density–weighted 19 F imaging challenging. Recent advances in tracer paramagnetic metallo-perfluorocarbon (MPFC) nanoemulsion probes have shown multifold SNR improvements due to an accelerated 19 F T 1 relaxation rate and a commensurate gain in imaging speed and averages. However, 19 F T 2 -reduction and increased linewidth limit the amount of metal additive in MPFC probes, thus constraining the ultimate SNR. To overcome these barriers, we describe a compressed sampling (CS) scheme, implemented using a “zero” echo time (ZTE) sequence, with data reconstructed via a sparsity-promoting algorithm. Our CS-ZTE scheme acquires k-space data using an undersampled spherical radial pattern and signal averaging. Image reconstruction employs off-the-shelf sparse solvers to solve a joint total variation and -norm regularized least square problem. To evaluate CS-ZTE, we performed simulations and acquired 19 F MRI data at 11.7 T in phantoms and mice receiving MPFC-labeled dendritic cells. For MPFC-labeled cells in vivo, we show SNR gains of ~6.3 × with 8-fold undersampling. We show that this enhancement is due to three mechanisms including undersampling and commensurate increase in signal averaging in a fixed scan time, denoising attributes from the CS algorithm, and paramagnetic reduction of T 1 . Importantly, 19 F image intensity analyses yield accurate estimates of absolute quantification of 19 F spins. Overall, the CS-ZTE method using MPFC probes achieves ultrafast imaging, a substantial boost in detection sensitivity, accurate 19 F spin quantification, and minimal image artifacts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Many-isocenter optimization for robotic radiotherapy

Despite significant dosimetric gains, clinical implementation of the 4π non-coplanar radiotherapy on the widely available C-arm gantry system is hindered by limited clearance, and the need to perform complex coordinated gantry and couch motion. A robotic radiotherapy platform would be conducive to such treatment but a new conflict between field size and MLC modulation resolution needs to be managed for versatile applications. This study investigates the dosimetry and delivery efficiency of purposefully creating many isocenters to achieve simultaneously high MLC modulation resolution and large tumor coverage. An integrated optimization framework was proposed for simultaneous beam orientation optimization (BOO), isocenter selection, and fluence map optimization (FMO). The framework includes a least-square dose fidelity objective, a total variation term for regularizing the fluence smoothness, and a group sparsity term for beam selection. A minimal number of isocenters were identified for efficient target coverage. Colliding beams excluded, high-resolution small-field 4π intensity-modulated radiotherapy (IMRT) treatment plans with 50 cm source-to-isocenter distance (SID-50) on 10 Head and Neck (H&N) cancer patients were compared with low-resolution large-field plans with 100 cm SID (SID-100). With the same or better target coverage, the average reduction of [Dmean, Dmax] of 20-beam SID-50 plans from 20-beam SID-100 plans were [2.09 Gy, 1.19 Gy] for organs at risk (OARs) overall, [3.05 Gy, 0.04 Gy] for parotid gland, [3.62 Gy, 5.19 Gy] for larynx, and [3.27 Gy, 1.10 Gy] for mandible. R50 and integral dose were reduced by 5.3% and 9.6%, respectively. Wilcoxon signed-rank test showed significant difference (p < 0.05) in planning target volume (PTV) homogeneity, PTV Dmax, R50, Integral dose, and OAR Dmean and Dmax. The estimated delivery time of 20-beam [SID-50, SID-100] plans were [19, 18] min and [14, 9] min, assuming 5 fractions and 30 fractions, respectively. Finally, with clinically acceptable delivery efficiency, many-isocenter optimization is dosimetrically desirable for treating large targets with high modulation resolution on the robotic platform.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low-complexity atlas-based prostate segmentation by combining global, regional, and local metrics

Purpose: To improve the efficiency of atlas-based segmentation without compromising accuracy, and to demonstrate the validity of the proposed method on MRI-based prostate segmentation application. Methods: Accurate and efficient automatic structure segmentation is an important task in medical image processing. Atlas-based methods, as the state-of-the-art, provide good segmentation at the cost of a large number of computationally intensive nonrigid registrations, for anatomical sites/structures that are subject to deformation. In this study, the authors propose to utilize a combination of global, regional, and local metrics to improve the accuracy yet significantly reduce the number of required nonrigid registrations. The authors first perform an affine registration to minimize the global mean squared error (gMSE) to coarsely align each atlas image to the target. Subsequently, atarget-specific regional MSE (rMSE), demonstrated to be a good surrogate for dice similarity coefficient (DSC), is used to select a relevant subset from the training atlas. Only within this subset are nonrigid registrations performed between the training images and the target image, to minimize a weighted combination of gMSE and rMSE. Finally, structure labels are propagated from the selected training samples to the target via the estimated deformation fields, and label fusion is performed based on a weighted combination of rMSE and local MSE (lMSE) discrepancy, with proper total-variation-based spatial regularization. Results: The proposed method was applied to a public database of 30 prostate MR images with expert-segmented structures. The authors’ method, utilizing only eight nonrigid registrations, achieved a performance with a median/mean DSC of over 0.87/0.86, outperforming the state-of-the-art full-fledged atlas-based segmentation approach of which the median/mean DSC was 0.84/0.82 when applying to their data set. Conclusions: The proposed method requires a fixed number of nonrigid registrations, independent of atlas size, providing desirable scalability especially important for a large or growing atlas. When applied to prostate segmentation, the method achieved better performance to the state-of-the-art atlas-based approaches, with significant improvement in computation efficiency. The proposed rationale of utilizing jointly global, regional, and local metrics, based on the information characteristic and surrogate behavior for registration and fusion subtasks, can be extended naturally to similarity metrics beyond MSE, such as correlation or mutual information types.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bayesian Spatially Varying Multi-Regularization Image Deblurring

Many scientific experiments such as those found in astronomy, geology, microbiology, and X-ray radiography require the use of high-energy instruments to capture images. Since blur and noise are inevitably present in any imaging system, the images must be \deblurred" to extract the full information content. Mathematically, image deblurring is an ill-posed inverse problem that requires regularization. The regularization, in turn, has a large effect on the deblurred image: different regularization strengths, and types, lead to drastically different reconstructions. Moreover, many images contain a mixture of smooth and sharp features which suggests the use of multi-regularization, i.e., varying the type of regularization (e.g. Tikhonov or total variation) across the image. We address these issues by formulating the image deblurring problem within a hierarchical Bayesian framework in which we spatially adapt the strength of the regularization and also vary the regularization type across the image. In this way, the image itself, along with corresponding regularization strength at each pixel, are described jointly by a posterior distribution which we can sample by Markov chain Monte Carlo (MCMC) methods. We illustrate our techniques on simplified test problems and apply them to high-energy X-ray images taken at the Nevada National Security Site. Numerical tests show that our new method is robustly applicable and increases the quality of the image reconstruction when compared to other (Bayesian) methods.

97 MATHEMATICS AND COMPUTING↗

Imaging the Schwarzschild-radius-scale Structure of M87 with the Event Horizon Telescope Using Sparse Modeling

We propose a new imaging technique for radio and optical/infrared interferometry. The proposed technique reconstructs the image from the visibility amplitude and closure phase, which are standard data products of short-millimeter very long baseline interferometers such as the Event Horizon Telescope (EHT) and optical/infrared interferometers, by utilizing two regularization functions: the ℓ {sub 1}-norm and total variation (TV) of the brightness distribution. In the proposed method, optimal regularization parameters, which represent the sparseness and effective spatial resolution of the image, are derived from data themselves using cross-validation (CV). As an application of this technique, we present simulated observations of M87 with the EHT based on four physically motivated models. We confirm that ℓ {sub 1} + TV regularization can achieve an optimal resolution of ∼20%–30% of the diffraction limit λ / D {sub max}, which is the nominal spatial resolution of a radio interferometer. With the proposed technique, the EHT can robustly and reasonably achieve super-resolution sufficient to clearly resolve the black hole shadow. These results make it promising for the EHT to provide an unprecedented view of the event-horizon-scale structure in the vicinity of the supermassive black hole in M87 and also the Galactic center Sgr A*.

79 ASTRONOMY AND ASTROPHYSICS↗

Superresolution Full-polarimetric Imaging for Radio Interferometry with Sparse Modeling

We propose a new technique for radio interferometry to obtain superresolution full-polarization images in all four Stokes parameters using sparse modeling. The proposed technique reconstructs the image in each Stokes parameter from the corresponding full-complex Stokes visibilities by utilizing two regularization functions: the ℓ {sub 1} norm and the total variation (TV) of the brightness distribution. As an application of this technique, we present simulated linear polarization observations of two physically motivated models of M87 with the Event Horizon Telescope. We confirm that ℓ {sub 1}+TV regularization can achieve an optimal resolution of ~25%–30% of the diffraction limit λ/D{sub max}, which is the nominal spatial resolution of a radio interferometer for both the total intensity (i.e., Stokes I) and linear polarizations (i.e., Stokes Q and U). This optimal resolution is better than that obtained from the widely used Cotton–Schwab CLEAN algorithm or from using ℓ {sub 1} or TV regularizations alone. Furthermore, we find that ℓ {sub 1}+TV regularization can achieve much better image fidelity in linear polarization than other techniques over a wide range of spatial scales, not only in the superresolution regime, but also on scales larger than the diffraction limit. Our results clearly demonstrate that sparse reconstruction is a useful choice for high-fidelity full-polarimetric interferometric imaging.

79 ASTRONOMY AND ASTROPHYSICS↗

Artifact reduction in industrial computed tomography via data fusion

As the most stressed part of a gas turbine the first row of turbine blades is not only a challenge for the materials used. Also the testing of these parts have to meet the highest standards. Computed tomography (CT) as the technique which could reveal the most details also provides the biggest challenges [1]: A full penetration of large sized turbine blades is often only possible at high X-ray voltages causing disproportional high costs. A reduction of the X-ray voltage is able to reduce these arising costs but yields non penetration artifacts in the reconstructed CT image. In most instances, these artifacts manifests itself as blurred and smeared regions at concave edges due to a reduced signal to noise ratio. In order to complement the missing information and to increase the overall image quality of our reconstruction, we use further imaging modalities such as a 3-D Scanner and ultrasonic imaging. A 3-D scanner is easy and cost effective to implement and is able to acquire all relevant data simultaneously with the CT projections. If, however, the interior structure is of supplemental interest, an ultrasonic imaging method is additionally used. We consider this data as a priori knowledge to employ them in an iterative reconstruction. To do so, standard iterative reconstruction methods are modified to incorporate the a priori data in a regularization approach in combination with minimizing the total variation of our image. Applying this procedure on turbine blades, we are able to reduce the apparent artifacts almost completely.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LATTE: open-source, high-performance traveltime computation, tomography and source location in acoustic and elastic media

Traveltime-based tomography and source location are fundamental approaches for imaging subsurface structures and understanding the spatiotemporal distribution of seismicity from local to global scales. We present an open-source, high-performance framework integrating eikonal equation solvers and adjoint-state theory for traveltime computation, velocity tomography, source location and joint tomography-location in 2-D/3-D acoustic and elastic media. We introduce novel regularization schemes based on total generalized p-variation, structural similarity and multitask machine learning to enhance the fidelity and interpretability of inverted models and source locations. Key features of our implementation also include the ability to leverage both absolute-difference and double-difference traveltime misfits for high-fidelity velocity tomography and source parameter estimation; support for traveltime computation and inversion in diverse 2-D/3-D scenarios with arbitrary source and receiver distributions; and a perturbation-based optimal step-size estimation method to reduce computational costs. In addition, our implementation employs shared-memory and distributed-memory parallelization to provide an efficient solution for traveltime computation, tomography, and source location. In conclusion, we validate the efficacy and accuracy of our approach through multiple synthetic data examples.

58 GEOSCIENCES↗