Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transactive Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Peak load reduction and load shaping in HVAC and refrigeration systems in commercial buildings by using a novel lightweight dynamic priority-based control strategy

Reducing peak power demand in a building can reduce electricity expenses for the building owner and contribute to the efficiency and reliability of the electrical power grid. For the building owner, reduced expenses come from the reduction or elimination of peak power charges on electricity bills. For the power system operator, reducing peak power demand leads to a more predictable load profile and reduces stress on the electric grid system. Herein we present a computationally inexpensive, dynamic, and retrofit-deployable control strategy to effect peak load reduction and load shaping. The effectiveness of the control strategy is examined in a simulation with 80 air-conditioning units and 40 refrigeration units. The results show that a peak demand reduction of 60 kW can be achieved relative to peak demand in a typical set point–based approach. The proposed strategy was deployed in a gymnasium building with four rooftop HVAC units, where it showed over 15% peak demand (kW) reduction savings while maintaining or lowering energy consumption (in kilowatt-hours) relative to the set point–based thermostat controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hierarchical Architecture for Transactive Wholesale-Retail Market Integration

Transactive control strategies for managing real-time energy consumption have been under study for a number of years. This work investigates a hierarchical control framework for such a system. This framework consist of two control layers to aggregate and reflect the flexibility of demand assets in the wholesale markets. Computation at each layer and communication across layers is designed to be minimal. The minimization of data exchange is done through demand curve approximation. To manage these two approximations, two intermediate layer dispatch strategies are compared: price-priority and quantity-priority. The price-priority dispatch results in significant differences between the wholesale cleared load and the actual retail load while the quantity-priority dispatch manages load much better at the cost of introducing uncertainty into the business cases of the intermediate layers.

Marinovici, Laurentiu D.↗

Optimal Demand Response Incorporating Distribution LMP with PV Generation Uncertainty

The utilization of aggregated demand-side flexibility via demand response (DR) has become a promising pathway for the integration of renewable energy resources in power systems. Nowadays, there are several management strategies for DR such as the price-based transactive control strategies. However, many of such existing price-based control strategies neglect the physics and operational constraints of the underlying distribution networks when computing the price, raising concerns regarding their theoretical and practical values. This paper studies this issue and investigates optimal DR (ODR) by incorporating the distribution locational marginal price (DLMP). In particular, we discuss DR in connection with DLMPs and propose a multiperiod bilevel optimization problem to find the ODR strategy. Here, the objective is to minimize the peak load, load fluctuation, and payments of load aggregators. In addition, a robust bilevel ODR model is formulated to provide a robust ODR strategy while minimizing operating costs under the worst-case realization of uncertainties; this mitigates the impact of forecasting errors on renewable energy resources. Then, we propose an efficient solution approach by employing the Karush-Kuhn-Tucker conditions and strong duality. Simulation results are presented to illustrate the mutual impacts of the interaction between DR and DLMP and the benefits of the robust ODR strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power Hardware-in-the-Loop Testing of Distribution Solid State Transformers

Savannah River National Laboratory and Resilient Power Systems have developed a utility grade solid state transformer and are planning on deploying it for testing in January 2018. The solid state transformer is the next generation solution to implementation of distributed energy resources such as solar and batteries. They can directly connect the solar and battery systems to DC ports and rout power between these DC ports and load ports. The solid state transformer can revolutionize current grid modernization initiatives by supplying grid support and building support services at the edge of the grid. These services consist of volt-VAR optimization, power factor correction, voltage regulation, frequency regulation, fault current support, demand side management, DC bus for AC/DC capable houses, and power routing between multiple ports for transactive control. For this fiscal year a test plan for testing the SST capabilities was develop. Along with the FPGA controls for the SST output ports. These controls will allow for any waveform to be produced by each port of the SST. Finally, a hybrid distribution SST was tested at the eGRID resulting in medium voltage testing experience for SRNL engineering team. DOE is currently engaged, through the Building Technology Office and Infrastructure Security and Energy Restoration in future work building from this project.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Applying the Transactive Systems Business Value Model to IRP

As part of the Transactive Systems Program at Pacific Northwest National Laboratory, a value modeling system was developed to support the evaluation of transactive systems. The technique is general enough to be applied outside transactive systems and to demonstrate this capability, a project was undertaken to use this value modeling technique as a means for modeling the valuation process undertaken by vertically integrated utilities when undergoing integrated resource planning (IRP). IRP is the process by which vertically integrated utilities (those that both serve customers directly as well as manage and run generation assets to do so) regularly go through to demonstrate to their regulators that they have a plan to meet the expected future load of their customers in a least cost and compliant manner. Traditionally this has been primarily an issue of how many and of which types of power plants to build but increasingly has included alternative measures such as demand response programs. Increasingly, environmental regulations play a significant role in both determine what types of power plants can be built under current regulations as well as what retrofits or upgrades need to be made to existing plants to allow them to continue to operate. Two use-case diagrams were constructed, one showing the showing the process by which IRP is carried out and another showing how a vertically integrated utility procures the resources it requires to meet load now and in the future. These diagrams help clarify the difference and provide a high-level outline of the two processes. A class diagram was constructed to clearly define the types of actors that would be considered in this model and the relationships between them. This diagram tacitly indicates which types of actors are and are not included in the model which provides significant guidance in defining the scope of the model. The relationship between the classes/actors provides further indication of what areas of the model have higher levels of detail and by implication bear more significance in modeling the system. Using the classes/actors defined in the class diagram, a business value diagram was constructed that defines the key value streams exchanged between the actors. This diagram provides a clear expression of the business case of the vertically integrated utility and who its counterparties are during the process of meeting load. These value streams have not only to do with meeting the load but doing so in a manner that meets environmental regulations. Increasingly, IRPs have three key metrics to evaluate a given plant to meet load: net present value of revenue required, emissions, and renewable energy credits. From this business value diagram, more detailed activity diagrams were formed that focus on a few of the key value stream exchanges, showing the process by which each party accrues value. These diagrams provide insight into the timing and sequence of the interactions in a way that the business value diagrams did not. The transactive value model was found to be highly compatible with IRP and provided a clear, simple model of the analysis done during IRP and key metrics driving IRP decisions. In particular it highlighted a few key items that may or may not have been as clear prior to the development of the model. Specifically, the role of the environmental regulations has become increasingly important and two of the three key metrics by which IRPs are typically evaluated are environmentally focused. Additionally, though generally not acknowledged, the role of the investor was included in this model as they are an essential source of capital in building new power plants and cannot be ignored when defining the business case of the vertically integrated utility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Connected Loads – Grid Connected Appliances: Commercial Refrigeration System Fault Detection and Diagnostics

As one of the most energy-intensive end-uses in the commercial buildings sector, supermarkets consume around 50 kWh/ft 2 (or 537.6 kWh/m 2 ) of electricity annually, or more than 2 million kWh of electricity per year for a typical store. The biggest consumer of energy in a supermarket is its refrigeration system, which accounts for 40–60% of its total electricity usage and is equivalent to about 2–3% of the total energy consumed by commercial buildings in United States, or around 0.5 quadrillion Btu (or 0.53 quadrillion KJ). Also, the supermarket refrigeration system is one of the biggest consumers of refrigerants. Current supermarket refrigeration systems rely on high global warming potential hydrofluorocarbon refrigerants. Reducing refrigerant usage or using environment friendly alternatives can result in significant climate benefits. Transcritical CO2 refrigeration systems have attracted more attention in recent years because of their zero-carbon emission advantages compared with traditional refrigerants. These systems are widely used in commercial buildings such as supermarkets. The refrigeration system can also be adapted to handle flexible building loads and be integrated into grid response transactive control to balance the supply and demand of the electric grid. Even minor improvements in the efficiency and operational reliability of supermarket refrigeration systems can create significant value in terms of saving energy, improving food quality, protecting the environment, reducing carbon footprint, and enhancing electric grid resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Connected Loads – Grid Connected Appliances: Deployment IoT Solution for Fault Detection and Diagnostics

As one of the most energy-intensive end-uses in the commercial buildings sector, supermarkets consume around 50 kWh/ft 2 ( or 537.6 kWh/m 2 ) of electricity annually, or more than 2 million kWh of electricity per year for a typical store. The biggest consumer of energy in a supermarket is its refrigeration system, which accounts for 40–60% of its total electricity usage and is equivalent to about 2–3% of the total energy consumed by commercial buildings in United States, or around 0.5 quadrillion Btu (or 0.53 quadrillion KJ). Also, the supermarket refrigeration system is one of the biggest consumers of refrigerants. Current supermarket refrigeration systems rely on high global warming potential hydrofluorocarbon refrigerants. Reducing refrigerant usage or using environment friendly alternatives can result in significant climate benefits. Transcritical CO2 refrigeration systems have attracted more attention in recent years because of their zero-carbon emission advantages compared with traditional refrigerants. These systems are widely used in commercial buildings such as supermarkets. The refrigeration system can also be adapted to handle flexible building loads and be integrated into grid response transactive control to balance the supply and demand of the electric grid. Even minor improvements in the efficiency and operational reliability of supermarket refrigeration systems can create significant value in terms of saving energy, improving food quality, protecting the environment, reducing carbon footprint, and enhancing electric grid resilience. For decarbonization, the new administration has set a target to reduce greenhouse gas emissions by 50– 52% by 2030 and targeting a carbon-neutral economy by 2050. For electrification, the goal is to achieve 100% clean electricity by 2035. Such decarbonization and electrification in the building sector require that energy consumption in buildings be reduced significantly. Therefore, the building sector must continuously adopt new technologies to achieve its energy and carbon emission goals. One of the most fundamental technologies is the Internet of Things (IoT). IoT has proven to be an effective solution for the building domain, including building information/energy modeling, smart buildings, etc. Although much progress has been made in the development of IoT-based building energy systems, there is still a lack of reliable, scalable, and affordable IoT-based automated fault and degradation diagnostics (AFDDs) solutions. Such solutions would enable deployment of advanced algorithms into real systems to archive the projected energy benefits. This study reviews existing IoT solutions developed for building energy– related application and developed a simple but effective AFDD IoT deployment solution, including developing a suitable IoT architecture and conducting easy and scalable deployment by leveraging a common cloud-based IoT service.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of Connected Lighting System Potential for Grid Services Under Real-Time Pricing

Increasingly over the last decade, the management of end-use electricity demand has been examined as a potential source of services for the electric power grid beyond contracts with large commercial and industrial customers. Lighting represents about 17\% of U.S. commercial building annual electricity consumption; however, its potential rapid speed of response may position it to uniquely contribute to services that improve the reliability and resilience of the grid. Connected lighting systems (CLS), which build upon solid-state lamp technology, can change state by adjusting power demand more quickly than most other building electricity end uses and could be used as a platform to monitor lighting electricity use and space conditions. But the potential of CLS to provide grid services has not been extensively studied. In this paper, we describe initial research to evaluate the potential of CLS for grid services. We develop a model for CLS using a set of parameters to represent operation behaviors and constraints: maximal power, minimal power, nominal power, ramp rate, and time delay. Parameter values are generated for representative building types. CLS demand curves are constructed, indirectly capturing building occupant preferences for lighting as functions of electricity price. The CLS model and the demand curves are incorporated into a Transactive Control and Coordination (TCC) Platform to simulate CLS providing grid services. Previous research has shown TCC to be a powerful tool to enable end uses to provide grid services through a hybrid economic-control approach. Initial quantitative results will be provided for CLS grid services potential.

Wang, Peng↗

Transactive Energy: Stabilizing Oscillations in Integrated Wholesale-Retail Energy Markets

Transactive energy is a control technique that uses market mechanisms to achieve desired control objectives. A number of studies have identified a well-known economic theory effect called a ``cobweb'' that can occur when the transactive control system is not properly designed. This work proposes a control framework to mitigate this effect by adding an extra control layer. This proposed control layer expresses the flexibility of load on the distribution side into the transmission system. By using FNCS, a co-simulation platform, new control framework is evaluated on a power system model composed of a single transmission system with the potential of thousands of flexible distribution systems. The co-simulation is able to replicate the cobweb effect and demonstrate that improper transactive control design can create oscillations at high penetrations of price-responsive loads. Furthermore, the proposed transactive control system is shown to be able to eliminate the cobweb effect while also effectively diminishing price and load spikes.

power distribution control, power distribution eco↗

Simplified Transactive Distribution Grids for Bulk Power System Mechanism Development

As distributed energy resources and smart devices become omnipresent in the electrical power grid, transactive energy control mechanisms are evolving. From real-time to day-ahead markets, these transactive energy algorithms involve more and more agents, whose behavior is going to affect the transmission and generation network. In order to study the interaction between the wholesale and retail energy markets, extensive co-simulations are performed. To be able to redesign, evaluate, and verify new control algorithms, the simulations need to provide results in a fast and reliable manner. This work has built and tested a transactive distribution grid model, the DSO-Stub, meant to offer a configurable distribution retail market while ensuring the computational burden is not significantly increased.

Transactive Energy, , Distribution System Operator↗

Real-Time MPC for Residential Building Water Heater Systems to Support the Electric Grid

The world of IoT (internet of things) is spawning new control options and decision making that has not been available before. This is providing a wealth of opportunities for transactive type controls and systems that can negotiate for a common goal. This paper discusses a transactive residential neighborhood with optimization at the home level utilizing a system of agents. The real-time optimization utilizes information and modeling to optimize heat pump water heater operation in occupied homes. Data is presented showing the performance of the optimization and conclusions are drawn on next steps for development.

Starke, Michael↗

Transactive System: Part I: Theoretical Underpinnings of Payoff Functions, Control Decisions, Information Privacy, and Solution Concepts

The increased penetration of renewable energy has significantly changed the conditions and the operational timing of the electricity grid. More flexible, faster ramping resources are needed to compensate for the uncertainty and variability introduced by renewable energy. Distributed energy resources (DERs) such as distributed generators, energy storage, and controllable loads could help manage the power grid in terms of both economic efficiency and operational reliability. In order to realize the benefits of DERs, coordination and control approaches must be designed to enable seamless integration of DERs into the power grid. Transactive coordination and control is a new approach for DER integration, where individual resources are automated and engaged through market interaction. Transactive approaches use economic signals—prices or incentives—to engage DERs. These economic signals must reflect the true value of the DER contributions, so that they seamlessly and equitably compete for the opportunities that today are only available to grid-owned assets. Value signals must be communicated to the DERs in near-real time, the assets must be imbued with new forms of distributed intelligence and control to take advantage of the opportunities presented by these signals, and they must be capable of negotiating and transacting a range of market-driven energy services. The concepts of transactive energy systems are not new, but build upon evolutionary economic changes in financial and electric power markets. These concepts also recognize the different regional structures of wholesale power markets, electricity delivery markets, retail markets, and vertically integrated service provider markets. Although transactive energy systems are not revolutionary, they will be transformational in their ability to provide flexibility and operational efficiency. A main goal of this research is to establish useful foundation for analysis of transactive energy systems and to facilitate new transactive energy system design with demonstrable guarantees on stability and performance. Specifically, the goals are to (1) establish a theoretical basis for evaluating the performance of different transactive systems, (2) devise tools to address canonical problems that exemplify challenges and scenarios of transactive systems, and (3) provide guidelines for design of future transactive systems. This report, Part 1 of a two part series, advances the above-listed research objectives by reviewing existing transactive systems and identifying a theoretical foundation that integrates payoff functions, control decisions, information privacy, and mathematical solution concepts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dilated causal convolutional neural networks for forecasting zone airflow to estimate short-term energy consumption

Here this paper investigates the use of dilated causal convolutional neural networks for fine- grained temporal forecasting of building zone states. Specifically, we build and evaluate models using a small set of exogenous features (e.g., external temperature) to autoregressively predict zone airflow setpoints every minute for a 24-hour prediction window. We carefully explore the trade-off between generality and specificity in these models, training and evaluating them based on zone, zone type, month, season, and combinations thereof. When evaluated for a commercial office building in Eastern Washington with 16 zones served by variable air volume air handling units, we find that the highest performance comes from a zone-specific, season-agnostic approach; with it, we obtain an R 2 of 0.704 (averaged over zones) and an average normalized root mean square error (nRMSE) of 0.111. In contrast, the most general model (trained across all zones and seasons) yields an R 2 of only 0.416 and a nRMSE of 0.168, while a baseline zone-specific reduced order model obtains 0.443 R 2 and 0.159 nRMSE. We also report on factors affecting airflow forecasting performance, on the ability of models trained on a specific zone to generalize to other zones, and on the capability of those models trained on a specific month to generalize to other months.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Real-Time Automated Hazard Detection Framework for Health Information Technology Systems

An increase in the reliability of Health Information Technology (HIT) will facilitate institutional trust and credibility of the systems. Here, we present an end-to-end framework for improving the reliability and performance of HIT systems. Specifically, we describe the system model, present some of the methods that drive the model, and discuss an initial implementation of two of the proposed methods using data from the Veterans Affairs HIT and Corporate Data Warehouse systems. The contributions of this work, thus, include (1) the design of a system model for monitoring and detecting hazards in HIT systems, (2) a data-driven approach for analysing the health care data warehouse, (3) analytical methods for characterising and analysing failures in HIT systems, and (4) a tool architecture for generating and reporting hazards in HIT systems. Our goal is to work towards an automated system that will help identify opportunities for improvements in HIT systems.

97 MATHEMATICS AND COMPUTING↗

Agent-Based Framework for Supporting Behind the Meter Transactive Power Electronic Systems

In this paper, the concept of a framework based on an agent-based interface for power stages in a power electronic system is presented. The presented concept or agent system is able to consider any number of different types of sources, types of converters, communication protocols, embedded decision making to support transactive, and hierarchy for large system integration. The concept is presented through several examples including the implementation on an actual physical system and demonstration of transactive type controls.

Starke, Michael↗

Robust hierarchical dispatch for residential distribution network management considering home thermal flexibility and model predictive control

In the transactive energy (TE) paradigm, the devices of participative consumers, or prosumers, may be aggregated and employed to drive operational objectives at the network level. Home heating, ventilation and air-conditioning (HVAC) systems in particular are well-suited to modulate their behaviours based on both home thermal flexibility and requests from the utility grid. This paper develops a robust, hierarchical power dispatch scheme in the context of a residential distribution network. The formulation couples a unique, multiphase linear distribution optimal power flow (OPF) at the upper level with model predictive control (MPC)-based HVAC fleet controllers at the lower level. The proposed approach is tested on nearly 2000 homes with a three-phase distribution network in an intraday market setting, where two major applications are explored and analysed.

24 POWER TRANSMISSION AND DISTRIBUTION↗