Search NASA⌕ Search

SEARCH · Search NASA

Results for “Trigger detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Identification and denoising of radio signals from cosmic-ray air showers using convolutional neural networks

Radio pulses generated by cosmic-ray air showers can be used to reconstruct key properties like the energy and depth of the electromagnetic component of cosmic-ray air showers. Radio detection threshold, influenced by natural and anthropogenic radio background, can be reduced through various techniques. In this work, we demonstrate that convolutional neural networks (CNNs) are an effective way to lower the threshold. We developed two CNNs: a classifier to distinguish radio signal waveforms from background noise and a denoiser to clean contaminated radio signals. Following the training and testing phases, we applied the networks to air-shower data triggered by scintillation detectors of the prototype station for the enhancement of IceTop, IceCube’s surface array at the South Pole. Over a four-month period, we identified 554 cosmic-ray events in coincidence with IceTop, approximately five times more compared to a reference method based on a cut on the signal-to-noise ratio. Comparisons with IceTop measurements of the same air showers confirmed that the CNNs reliably identified cosmic-ray radio pulses and outperformed the reference method. Additionally, we find that CNNs reduce the false-positive rate of air-shower candidates and effectively denoise radio waveforms, thereby improving the accuracy of the power and arrival time reconstruction of radio pulses.

Abbasi, R↗

Beam Non-Uniformity Characterization at the SpinQuest and DarkQuest Experiments

The SpinQuest experiment, including upgrades to SpinQuest designed to increase sensitivity to dark sector searches (commonly known as DarkQuest), utilizes the high-intensity 120 GeV proton beam delivered by the Fermilab Accelerator Complex to probe the inner structure of nucleons and search for new physics beyond the Standard Model. The SpinQuest beam is extracted from the Main Injector synchrotron at Fermilab in what is known as a slow spill . The slow spill involves a complex non-linear half-integer extraction method, which results in non-uniform beam behavior. SpinQuest observes spikes of very high intensity beam which can saturate detectors and reduce trigger efficiency, significantly impacting the experiment's sensitivity. In this project we address this challenge by developing an analysis framework to characterize the beam delivered to SpinQuest. By discovering trends within each spill and by comparing thousands of spills, we can better inform the Accelerator Division and improve the slow spill extraction. We have also begun a collaboration with the Accelerator Division in order to simulate the slow spill and improve the magnet ramp process controls which will improve the uniformity of the beam. These improvements will directly enhance the physics reach of SpinQuest/DarkQuest, increasing their sensitivity to key measurements such as the Sivers function and searches for new physics.

Dolen, James William [Purdue U., Calumet] (ORCID:0↗

A study of the scintillation light induced in liquid xenon by electrons and alpha particles

The time dependence and the intensity of the primary scintillation light in liquid Xe excited by Am-241 alpha particles and Bi-207 internal-conversion electrons were measured at different electric-field strengths. High-purity liquid Xe was used to fill a parallel-plate ionization chamber equipped with a CaF2 window coupled to a UV-sensitive photomultiplier tube. The effect of the specific ionization density on the scintillation light and the time correlation between the light signal and the charge signal is reported. It is demonstrated that the fast scintillation signal produced in liquid Xe by an ionizing particle provides an ideal trigger in a detector aiming at a complete three-dimensional event reconstruction with an excellent background rejection capability.

Aprile, Elena↗

A modular solid state detector for measuring high energy heavy ion fragmentation near the beam axis

A multi-element solid state detector has been designed to measure fluences of fragments produced near the beam axis by high energy heavy ion beams in thick targets. The detector is compact and modular, so as to be readily reconfigured according to the range of fragment charges and energies to be measured. Preamplifier gain settings and detector calibrations are adjustable remotely under computer control. We describe the central detector, its associated detectors and electronics, triggering scheme, data acquisition and particle identification techniques, illustrated by data taken with 600 MeV/u 56Fe beams and thick polyethylene targets at the LBL Bevalac. The applications of this work to space radiation protection are discussed.

NASA Center HQS↗

Production and installation of wavelength-shifting reflective light enhancers for the Short-Baseline Near Detector

We report on the design, production, and installation of a wavelength-shifting reflective system on the cathode of the Short-Baseline Near Detector (SBND), a liquid argon time projection chamber located along the Fermilab Booster Neutrino Beam. To increase and homogenize scintillation-light collection, 64 double-sided plates were fabricated from FR4, laminated with specular reflector film and coated with 300 $μ$g/cm$^2$ of tetraphenyl butadiene (TPB) wavelength shifter using controlled physical vapor deposition. The coating uniformity was validated through dedicated measurements of deposited mass and profilometry studies. Because exposure to ambient blue/UV light could degrade the TPB, protective filtering and controlled storage conditions were implemented during handling and installation. The coated plates were assembled between conductive meshes for high-voltage compatibility and installed in situ during detector integration. This system constitutes the largest TPB-coated area deployed in a neutrino detector. It operates in conjunction with SBND's photon detection system, which consists of photomultiplier tubes and X-ARAPUCAs. Early light-collection measurements show high uniformity and light response across the detector, supporting improved triggering, calorimetry, and position reconstruction in SBND.

Acciarri, R. [Fermilab]↗

Intelligent Triggers for Rare Event Detection in Liquid Argon Detectors

Next-generation neutrino experiments like SBND and DUNE rely on Liquid Argon Time Projection Chambers (LArTPCs), which produce exceptionally detailed data at high volume. Capturing rare or unexpected events in real-time is a major challenge. Our project explores the use of machine learning, specifically autoencoder-based anomaly detection, to identify unusual activity directly from raw detector signals. Inspired by successes at the CMS experiment, we demonstrate that such methods can be adapted to LArTPCs and show promising results in both simulated studies and early steps toward real-time hardware deployment. This approach could open new avenues for detecting signals from physics beyond the Standard Model.

Chung, Seokju [Columbia U. (main)]↗

Real-Time Anomaly Detection for Charge-Based Triggering in LArTPCs

Modern particle detectors, including liquid argon time projection chambers (LArTPCs), collect a vast amount of data, making it impractical to save everything for offline analysis. As a result, these experiments need to employ different down-selection techniques during data acquisition, referred to as triggering. In this talk, I will present a framework that would enable real-time, data-driven triggering for LArTPCs, using anomaly detection algorithms implemented on Field-Programmable Gate Arrays (FPGAs). Drawing on a study that makes use of collected charge data from the MicroBooNE LArTPC Public Dataset, I will discuss the overall performance of such algorithms and potential applications for future neutrino experiments.

43 PARTICLE ACCELERATORS↗

MiniDAQ-3: Providing concurrent independent subdetector data-taking on CMS production DAQ resources

The data acquisition (DAQ) of the Compact Muon Solenoid (CMS) experiment at CERN, collects data for events accepted by the Level-1 Trigger from the different detector systems and assembles them in an event builder prior to making them available for further selection in the High Level Trigger, and finally storing the selected events for offline analysis. In addition to the central DAQ providing global acquisition functionality, several separate, so-called “MiniDAQ” setups allow operating independent data acquisition runs using an arbitrary subset of the CMS subdetectors. During Run 2 of the LHC, MiniDAQ setups were running their event builder and High Level Trigger applications on dedicated resources, separate from those used for the central DAQ. This cleanly separated MiniDAQ setups from the central DAQ system, but also meant limited throughput and a fixed number of possible MiniDAQ setups. In Run 3, MiniDAQ-3 setups share production resources with the new central DAQ system, allowing each setup to operate at the maximum Level-1 rate thanks to the reuse of the resources and network bandwidth. Configuration management tools had to be significantly extended to support the synchronization of the DAQ configurations needed for the various setups. We report on the new configuration management features and on the first year of operational experience with the new MiniDAQ-3 system.

Amoiridis, Vassileios↗

Beam test performance studies of CMS Phase-2 Outer Tracker module prototypes

A new tracking detector will be installed as part of thePhase-2 upgrade of the CMS detector for the high-luminosity LHC era.This tracking detector includes the Inner Tracker, equipped withsilicon pixel sensor modules, and the Outer Tracker, consisting ofmodules with two parallel stacked silicon sensors. The Outer Trackerfront-end ASICs will be able to correlate hits from chargedparticles in these two sensors to perform on-module discriminationof transverse momenta (p$_{T}$). The p$_{T}$information is generated at a frequency of 40 MHz and will be usedin the Level-1 trigger decision of CMS. Prototypes of theso-called 2S modules were tested at the Test Beam Facility at DESYHamburg between 2019 and 2020. These modules use the finalfront-end ASIC, the CMS Binary Chip (CBC), and for the firsttime the Concentrator Integrated Circuit (CIC), optical readoutand on-module power conversion. In total, seven modules were tested,one of which was assembled with sensors irradiated with protons. Animportant aspect was to show that it is possible to read out modulessynchronously. A cluster hit efficiency of about 99.75 % wasachieved for all modules. The CBC p$_{T}$ discriminationmechanism has been verified to work together with the CIC andoptical readout. The measured module performance meets therequirements for operation in the upgraded CMS tracking detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Construction of a High-Resolution Hodoscope for the GlueX Experiment with High-Statistics Analysis of the p0, ¿, and ¿1 Photoproduction Cross Sections from the RadPhi Experiment

Differential cross sections for forward-angle photoproduction of p0, ¿, and ¿ 1 pseudoscalar mesons were measured using data from the RadPhi experiment conducted in Hall B at Jef ferson Lab. RadPhi utilized a tagged bremsstrahlung photon beam incident on a stationary 9Be target, with a detector system configured to trigger on a recoil proton in coincidence with multiple neutral showers in the calorimeter. Events were reconstructed and subjected to kinematic constraints, with background suppressed via sideband subtraction guided by Monte Carlo modeling of background contributions. Cross sections were extracted over the photon energy range 4.4– 5.4 GeV and binned in invariant momentum transfer t, providing measurements from one of the first high-statistics experiments of forward ¿ and ¿1 pro duction from a nuclear target at these energies. Acceptance corrections were applied using a detailed GEANT-based simulation of the detector geometry and response. The resulting cross sections are consistent with 2020 CLAS results, when scaled by the number of protons in beryllium, and show broad agreement with other data and theoretical models. In parallel, a high-resolution photon tagger detector, the Tagger Microscope (TAGM), was designed, constructed, and commissioned for the GlueX experiment in Hall D at Jefferson Lab. The TAGM was developed to provide high-rate tagging capability in the coherent bremsstrahlung peak by detecting post-bremsstrahlung electrons across a one GeV range along the focal plane of the tagging spectrometer. The detector consists of a 5ˆ102 array of 2ˆ2 mm2 square BCF-20 plastic scintillating fibers thermally fused to BCF-98 light guide fibers optically coupled to silicon photomultipliers. These fibers are mounted in a precision machined framework enabling fine positional adjustments to maintain precise alignment with post-bremsstrahlung electron trajectories, while ensuring mechanical rigidity, thermal stability, optical isolation, minimal inactive area, and radiation shielding for electronics. The construction effort involved extensive testing of fiber quality, light transmission, thermal fusing, radiation hardness, and defect analysis using SEM and EDX techniques. Following its installation and commissioning, the TAGM became a critical component of the GlueX beamline, enabling high-rate tagging essential for studies of hybrid mesons and gluonic ex citations.

McIntyre, James [Univ. of Connecticut, Storrs, CT ↗

Lead tungstate calorimeter of the Jefferson Lab Eta Factory experiment

A new electromagnetic calorimeter (ECAL) consisting of 1596 lead tungstate PbWO 4 scintillating crystals has been fabricated and installed in the experimental Hall D at Jefferson Lab (JLab). The highgranularity, high-resolution calorimeter is required by the JLab Eta Factory experiment, whose main physics goal is to study rare decays of eta mesons. The ECAL replaced the inner part of the forward lead glass calorimeter of the GlueX detector. Signals from the detector will be digitized using twelve-bit flash analog-to-digital converters operated at a sampling rate of 250 MHz. The ECAL is integrated into the trigger system of the GlueX detector using electronics modules designed at JLab. The ECAL is currently at the commissioning stage and should be ready for the physics run in January 2025. We will give an overview of the JEF experiment, the design and construction of the ECAL, and the integration of the detector and its infrastructure into the Hall D experimental setup.

Somov, Alexander [Thomas Jefferson National Accele↗

Performance of the LHCb muon detector in Run 3

In Run 3 of the LHC, the instantaneous luminosity at the LHCb interaction point has been increased by a factor of five, from to $\mathscr{L}$ = 4 x 10 32 cm -2 s -2 to $\mathscr{L}$ = 2 x 10 33 cm -2 s -1 . Several hardware interventions, including a complete overhaul of the readout electronics, have been carried out on the muon detector. The muon identification algorithms in the software trigger were improved with the aim of ensuring Run 2 performance under a higher particle rate. The operation and calibration of the upgraded muon detector are presented. The muon detection efficiency and muon identification performance are evaluated on data calibration samples collected during the year 2024. A muon identification efficiency above 90% with sub-percent hadron misidentification probability is achieved by exploiting the pattern of hits in the muon detector.

Gaseous detectors↗

Light detection and cosmic rejection in the ICARUS LArTPC at Fermilab

Abstract The ICARUS-T600 detector is a 760-ton Liquid Argon Time Projection Chamber (LArTPC) currently operating at Fermilab as the Far Detector in the Short Baseline Neutrino (SBN) program. The SBN program is composed of three LArTPCs with a central goal of testing the sterile neutrino hypothesis. After operating for 3-years in the Gran Sasso Underground Laboratory, the ICARUS detector was shipped to CERN where it was outfitted with 360 8” Photomultiplier Tubes (PMTs) for a new optical detection system. The PMT system detects fast scintillation light from charged particles interacting in the Liquid Argon, generating the trigger signal for the full detector and allows 3D reconstruction of events. Now operating at shallow depth, the detector is exposed to a high flux of cosmic rays that can fake neutrino interactions. To mitigate this effect a Cosmic Ray Tagger (CRT) and a 3-meter-thick concrete were installed. Precise timing information from both the PMT and CRT subsystems can help to identify whether an interaction originated from inside or outside of the ICARUS cryostat. This paper reviews a method for cosmogenic background reduction and timing calibration of the CRT and PMT light detection systems in ICARUS.

Instruments & Instrumentation↗

Analysis of SOFCAL calibration data

Ionization calorimeters determine the total energy of a particle by absorbing, within the mass of the calorimeter, the entire energy of the particle or a significant (and determinable) fraction of it. The JACEE group has used passive ionization calorimetery, which employs photographic emulsions as the detector medium, to measure the charge composition and energy spectrum of cosmic rays up to, and exceeding, 10(exp 14)eV. The SOFIC approach depends similarly on the use of three-dimensional nuclear-electromagnetic shower theory to relate the ionization deposits obtained during a shower to the energy of the particle causing the shower. Bundles of thousands of scintillating optical fibers are read out using image-intensified CCD's. Such an event may be triggered by a fast shower detector placed under the instrument or if only heavy particles are of interest, from a fast primary Cerention detector placed above the calorimeter. In the first study, fast Hammatsu photomultiplier tubes were purchased and tested for possible application for a triggering purpose. In the second study, some refinements have been made to the theoretical treatment of hadronic interactions in the central collision region. These will be helpful in improving the simulations necessary for observations of high energy cosmic ray nuclei with a SOFIC.

Gregory, John C.↗

The ATLAS experiment at the CERN Large Hadron Collider: a description of the detector configuration for Run 3

The ATLAS detector is installed in its experimental cavern at Point 1 of the CERN Large Hadron Collider. During Run 2 of the LHC, a luminosity of ℒ = 2 × 10 34 cm -2 s -1 was routinely achieved at the start of fills, twice the design luminosity. For Run 3, accelerator improvements, notably luminosity levelling, allow sustained running at an instantaneous luminosity of ℒ = 2 × 10 34 cm -2 s -1 , with an average of up to 60 interactions per bunch crossing. The ATLAS detector has been upgraded to recover Run 1 single-lepton trigger thresholds while operating comfortably under Run 3 sustained pileup conditions. A fourth pixel layer 3.3 cm from the beam axis was added before Run 2 to improve vertex reconstruction and b-tagging performance. New Liquid Argon Calorimeter digital trigger electronics, with corresponding upgrades to the Trigger and Data Acquisition system, take advantage of a factor of 10 finer granularity to improve triggering on electrons, photons, taus, and hadronic signatures through increased pileup rejection. The inner muon endcap wheels were replaced by New Small Wheels with Micromegas and small-strip Thin Gap Chamber detectors, providing both precision tracking and Level-1 Muon trigger functionality. Trigger coverage of the inner barrel muon layer near one endcap region was augmented with modules integrating new thin-gap resistive plate chambers and smaller-diameter drift-tube chambers. Tile Calorimeter scintillation counters were added to improve electron energy resolution and background rejection. Upgrades to Minimum Bias Trigger Scintillators and Forward Detectors improve luminosity monitoring and enable total proton-proton cross section, diffractive physics, and heavy ion measurements. These upgrades are all compatible with operation in the much harsher environment anticipated after the High-Luminosity upgrade of the LHC and are the first steps towards preparing ATLAS for the High-Luminosity upgrade of the LHC. This paper describes the Run 3 configuration of the ATLAS detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Dark Energy Camera Search for an Optical Counterpart to the First Advanced LIGO Gravitational Wave Event GW150914

We report the results of a deep search for an optical counterpart to the gravitational wave (GW) event GW150914, the first trigger from the Advanced LIGO GW detectors. We used the Dark Energy Camera (DECam) to image a 102 deg(exp 2) area, corresponding to 38% of the initial trigger high-probability sky region and to 11% of the revised high-probability region. We observed in the i and z bands at 4-5, 7, and 24 days after the trigger. The median 5(sigma) point-source limiting magnitudes of our search images are i = 22.5 and z = 21.8 mag. We processed the images through a difference-imaging pipeline using templates from pre-existing Dark Energy Survey data and publicly available DECam data. Due to missing template observations and other losses, our effective search area subtends 40 deg(exp 2), corresponding to a 12% total probability in the initial map and 3% in the final map. In this area, we search for objects that decline significantly between days 4-5 and day 7, and are undetectable by day 24, finding none to typical magnitude limits of i = 21.5, 21.1, 20.1 for object colors (i-z)= 1, 0, -1, respectively. Our search demonstrates the feasibility of a dedicated search program with DECam and bodes well for future research in this emerging field.

binaries: close – catalogs – gravitational wav↗

Machine Learning-Based Extreme Data Reduction for Prompt Supernova Pointing at DUNE

One of the goals of the Deep Underground Neutrino Experiment (DUNE) is to use the massive underground liquid argon time projection chamber (LArTPC) detectors at its far site for multimessenger astronomy (MMA), in the detection of neutrinos from core-collapse supernovae (SNe). Its current baseline trigger strategy detects activity in the detector that is consistent with supernova (SN) neutrinos and saves the raw data for further offline analysis but provides no prompt pointing information crucial for optical follow-ups by other observatories. This approach is based on the assumption that prompt pointing determination using raw data is computationally prohibitive. In this article, we demonstrate a proof-of-concept based on applying extreme data reduction on the buffered SN data in the DUNE data acquisition (DAQ) system’s front-end computers using a machine learning (ML) workflow. This reduces the data by ~5 orders of magnitude, allowing a full track reconstruction to be carried out quickly on a single server. The total time to perform the ML-based data reduction and the full track reconstruction is less than the time to transfer the SN data back to Fermilab or a high-performance computing (HPC) center. This shows that prompt processing of raw SN data is possible and, in fact, trivial once the data have been reduced to reject radiological backgrounds, paving the way to a high-quality SN pointing trigger that is based on fully reconstructed data instead of trigger primitives (TPs).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ECON-T and ECON-D: Endcap Concentrator ASICs for the CMS HGCAL

With over 6 million channels, the High Granularity Calorimeter (HGCAL) for the CMS HL-LHC Upgrade presents a unique data challenge. The ECON ASICs provide critical on-detector data reduction for the 40 MHz trigger path (ECON-T) and 750 kHz data acquisition path (ECON-D) of the HGCAL. The ASICs, fabricated in 65 nm CMOS, are rad-tolerant (600 Mrad) with low power consumption (<2.5 mW/channel). This presentation is the first comprehensive description of the ECON designs, first functionality and radiation tests for the ECON-T ASIC, and first results from the full production of 75k ECON-D and ECON-T ASICs.

Bergamin, G. [CERN] (ORCID:0000000285758704)↗