Comparison of elastic and elastic-plastic structural analyses for cooled turbine blade airfoils

Elastic plastic stress strain states in cooled turbine blade airfoils were calculated by three methods for the initial takeoff transient of an advanced technology aircraft engine. The three analytical methods compared were a three dimensional elastic plastic, finite element analysis, a three dimensional, elastic, finite element analysis, and a one dimensional, elastic plastic, beam theory analysis. Structural analyses were performed for eight cases involving different combinations of mechanical and thermal loading on impingement cooled airfoils with and without leading edge film cooling holes. The von Mises effective total strains at maximum takeoff computed from the elastic and elastic plastic finite element analyses agreed with 9 percent for rotating airfoils and 28 percent for stationary airfoils with the elastic results on the conservative side.

Kaufman, A.↗

Advances in measuring techniques for turbine cooling test rigs - Status report

Instrumentation development pertaining to turbine cooling research has resulted in the design and testing of several new systems. Pressure measurements on rotating components are being made with a rotating system incorporating ten miniature transducers and a slip-ring assembly. The system has been tested successfully up to speeds of 9000 rpm. An advanced system development combining pressure transducer and thermocouple signals is also underway. Thermocouple measurements on rotating components are transferred off the shaft by a 72-channel rotating data system. Thermocouple data channels are electronically processed on board and then removed from the shaft in the form of a digital serial train by one winding of a rotary transformer.

Pollack, F. G.↗

Cold air performance of a 12.766-centimeter-tip-diameter axial-flow cooled turbine. 2: Effect of air ejection on turbine performance

An air cooled version of a single-stage, axial-flow turbine was investigated to determine aerodynamic performance with and without air ejection from the stator and rotor blades surfaces to simulate the effect of cooling air discharge. Air ejection rate was varied from 0 to 10 percent of turbine mass flow for both the stator and the rotor. A primary-to-air ejection temperature ratio of about 1 was maintained.

Haas, J. E.↗

Revolutionizing Turbine Cooling with Micro-Architectures Enabled by Direct Metal Laser Sintering

The objective of this research effort was to explore innovative cooling architectures enabled by additive manufacturing techniques for improved turbine cooling performance. The ability to create complex internal geometries was leveraged to better distribute coolant as well as to integrate inherently unstable flow devices to enhance internal and external heat transfer. This was accomplished with a multi-faceted approach including analytical, experimental, and computational components. This final report documents progress during the total 4.25 year effort that was extended (at no additional cost) from the original 3-year cooperative agreement. Prior to starting the project, significant effort was invested in investigating innovative cooling designs from the open literature. When the project started, we quickly down-selected to 4 configurations: impingement jet fluidic oscillators (for internal leading edge cooling), reverse film cooling (for pressure surface), sweeping film cooling jets (for suction surface), and trailing edge slot cooling with microchannels. During the 2nd year, the reverse film cooling design was shown to be sub-optimal and work on that topic was halted. The three remaining technologies were integrated into a large scale nozzle guide vane and installed into a low-speed linear cascade facility for further interrogation. Initial results showed the sweeping film cooling jets (on the suction surface) to be the most promising technology compared to a baseline diffusion shaped film hole (777 design). The benefit was particularly evident at high blowing ratios (>1.5) when the 777 coolant film separated from the downstream surface. Benefits were also evident at elevated freestream turbulence levels. The leading edge cooling with unsteady jets was less effective in terms of peak or average cooling – however it was superior to round hole impingement cooling in terms of spatial uniformity. Finally, the trailing edge cooling design with micro-channels was scrapped in favor of a pinned arrangement with centerbody. During the 3rd year, the same three technologies were integrated into a transonic linear cascade for an assessment of compressibility effects. Again, the sweeping film cooling jets proved superior at high blowing ratios while the unsteady leading edge impingement and trailing edge pin-fins with centerbody designs yielded mixed results. Finally, during the 4th and final year, these 3 technologies were integrated into a direct metal laser sintered (DMLS) nozzle guide vane for testing in a high temperature, transonic annular vane cascade. The facility matches the flow temperature, Mach number, and coolant pressure ratios of an actual gas turbine. Before doing this, an additional series of tests were completed to validate a redesigned trailing edge cooling architecture. This final design included a centerbody with triangular pins between the centerbody and the vane external skin. The majority of these triangular pins are fabricated with a 30% gap to the centerbody – reducing their pressure drop considerably while still providing excellent heat transfer augmentation. This additional test campaign required an additional 3-month extension request to complete testing in the high temperature NGV test facility (Turbine Reacting Flow Rig – TuRFR). Testing of the DMLS vane in TuRFR pitted the 3 innovative cooling technologies against more traditional technologies (shaped 777 film hole, round impingement jet, and full pin arrangement in the trailing edge. The sweeping film cooling jets (on the suction surface) showed approximately 15% improvement in overall effectiveness compared to the 777 film hole while the trailing edge showed up to 20% improvement. The leading edge impingement was disappointing with a substantially lower effectiveness than traditional direct impingement. In summary, the study was successful in demonstrating that DMLS-enabled cooling technologies can yield significant gains in cooling performance.

03 NATURAL GAS↗

A high pressure, high temperature combustor and turbine-cooling test facility

A new test facility is being constructed for developing turbine-cooling and combustor technology for future generation aircraft gas turbine engines. Prototype engine hardware will be investigated in this new facility at gas stream conditions up to 2480 K average turbine inlet temperature and 4.14 x 10 to the 6th power n sq m turbine inlet pressure. The facility will have the unique feature of fully automated control and data acquisition through the use of an integrated system of mini-computers and programmable controllers which will result in more effective use of operating time, will limit the number of operators required, and will provide built in self protection safety systems. The facility and the planning and design considerations are described.

Cochran, R. P.↗

An analytical study of the effect of coolant flow variables on the kinetic energy output of a cooled turbine blade row.

Demonstration that the change in output of a cooled turbine blade row relative to the specific output of the uncooled blade row can be positive, negative, or zero, depending on the velocity, injection location, injection angle, and temperature of the coolant. Comparisons between the analytical results and experimental results for four different cases of coolant discharge, all at a coolant temperature ratio of unity, show good agreement for three cases, and rather poor agreement for the other.

Prust, H. W., Jr.↗

Designing Film-Cooled Turbine Disks

Technique optimizes weight and speeds of disks in film-cooled turbines. Proposed iterative approach to design enables shaping of turbine disks partly according to temperature profiles. Suitable for design of advanced stationary, aircraft, and rocket turbines.

Wagner, William R.↗

Metal temperatures and coolant flow in a wire cloth transpiration cooled turbine vane

An experimental heat transfer investigation was conducted on an air-cooled turbine vane made from wire-wound cloth material and supported by a central strut. Vane temperature data obtained are compared with temperature data from two full-coverage film-cooled vanes made of different laminated construction. Measured porous-airfoil temperatures are compared with predicted temperatures.

Gladden, H. J.↗

Aero-Thermo-Structural Design Optimization of Internally Cooled Turbine Blades

A set of robust and computationally affordable inverse shape design and automatic constrained optimization tools have been developed for the improved performance of internally cooled gas turbine blades. The design methods are applicable to the aerodynamics, heat transfer, and thermoelasticity aspects of the turbine blade. Maximum use of the existing proven disciplinary analysis codes is possible with this design approach. Preliminary computational results demonstrate possibilities to design blades with minimized total pressure loss and maximized aerodynamic loading. At the same time, these blades are capable of sustaining significantly higher inlet hot gas temperatures while requiring remarkably lower coolant mass flow rates. These results suggest that it is possible to design internally cooled turbine blades that will cost less to manufacture, will have longer life span, and will perform as good, if not better than, film cooled turbine blades.

Dulikravich, G. S.↗

Optimization of engines for a commercial Mach 0.98 transport using advanced turbine cooling methods

A study was made of an advanced technology airplane using supercritical aerodynamics. Cruise Mach number was 0.98 at 40,000 feet altitude with a payload of 60,000 pounds and a range of 3000 nautical miles. Separate-flow turbofans were examined parametrically to determine the effect of sea-level-static design turbine-inlet-temperature and noise on takeoff gross weight (TOGW) assuming full-film turbine cooling. The optimum turbine inlet temperature was 2650 F. Two-stage-fan engines, with cruise fan pressure ratio of 2.25, achieved a noise goal of 103.5 EPNdB with todays noise technology while one-stage-fan engines, achieved a noise goal of 98 EPNdB. The take-off gross weight penalty to use the one-stage fan was 6.2 percent.

Kraft, G. A.↗

A high-pressure, high-temperature combustor and turbine-cooling test facility

NASA-Lewis Research Center is presently constructing a new test facility for developing turbine-cooling and combustor technology for future generation aircraft gas turbine engines. Prototype engine hardware will be investigated in this new facility at gas stream conditions up to 2480 K average turbine inlet temperature and 4,140,000 N per sq m turbine inlet pressure. The facility will have the unique feature of fully-automated control and data acquisition through the use of an integrated system of minicomputers and programmable controllers, which will result in more effective use of operating time, will limit the number of operators required, and will provide a built-in self-protection safety system. The paper describes the facility and the planning and design considerations involved.

Cochran, R. P.↗

Analysis of spanwise temperature distribution in three types of air-cooled turbine blade

Methods for computing spanwise blade-temperature distributions are derived for air-cooled hollow blades, air-cooled hollow blades with inserts, and air-cooled blades containing internal cooling fins. Individual and combined effects on spanwise blade-temperature distributions of cooling-air and radial heat conduction are determined. In general, the effects of radiation and radial heat conduction were found to be small and the omission of these variations permitted the construction of nondimensional charts for use in determining spanwise temperature distribution through air-cooled turbine blades. An approximate method for determining the allowable stress-limited blade-temperature distribution is included, with brief accounts of a method for determining the maximum allowable effective gas temperatures and the cooling-air requirements. Numerical examples that illustrate the use of the various temperature-distribution equations and of the nondimensional charts are also included.

Livingood, John N B↗