Search NASA⌕ Search

SEARCH · Search NASA

Results for “Two Body Point Absorber”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

44 records · Page 3

TestDose: A nuclear medicine software based on Monte Carlo modeling for generating gamma camera acquisitions and dosimetry

Purpose: The TestDose platform was developed to generate scintigraphic imaging protocols and associated dosimetry by Monte Carlo modeling. TestDose is part of a broader project (www.dositest.com) whose aim is to identify the biases induced by different clinical dosimetry protocols. Methods: The TestDose software allows handling the whole pipeline from virtual patient generation to resulting planar and SPECT images and dosimetry calculations. The originality of their approach relies on the implementation of functional segmentation for the anthropomorphic model representing a virtual patient. Two anthropomorphic models are currently available: 4D XCAT and ICRP 110. A pharmacokinetic model describes the biodistribution of a given radiopharmaceutical in each defined compartment at various time-points. The Monte Carlo simulation toolkit GATE offers the possibility to accurately simulate scintigraphic images and absorbed doses in volumes of interest. The TestDose platform relies on GATE to reproduce precisely any imaging protocol and to provide reference dosimetry. For image generation, TestDose stores user’s imaging requirements and generates automatically command files used as input for GATE. Each compartment is simulated only once and the resulting output is weighted using pharmacokinetic data. Resulting compartment projections are aggregated to obtain the final image. For dosimetry computation, emission data are stored in the platform database and relevant GATE input files are generated for the virtual patient model and associated pharmacokinetics. Results: Two samples of software runs are given to demonstrate the potential of TestDose. A clinical imaging protocol for the Octreoscan™ therapeutical treatment was implemented using the 4D XCAT model. Whole-body “step and shoot” acquisitions at different times postinjection and one SPECT acquisition were generated within reasonable computation times. Based on the same Octreoscan™ kinetics, a dosimetry computation performed on the ICRP 110 model is also presented. Conclusions: The proposed platform offers a generic framework to implement any scintigraphic imaging protocols and voxel/organ-based dosimetry computation. Thanks to the modular nature of TestDose, other imaging modalities could be supported in the future such as positron emission tomography.

60 APPLIED LIFE SCIENCES↗

Stretchable Photodiodes with Polymer-Engineered Semiconductor Nanowires for Wearable Photoplethysmography

Healthcare systems worldwide have been stressed to provide sufficient resources to serve the increasing and aging population in our society. The situation became more challenging at the time of pandemic. Technology advancement, especially the adoption of wearable health monitoring devices, has provided an important supplement to current clinical equipment. Most health monitoring devices are rigid, however, human tissues are soft. Such a difference has prohibited intimate contact between the two and jeopardized wearing comfortableness, which hurdles measurement accuracy especially during longtime usage. Here, in this work, we report a soft and stretchable photodiode that can conformally adhere onto the human body without any pressure and measure cardiovascular variables for an extended period with higher reliability than commercial devices. The photodiode used a composite light absorber consisting of an organic bulk heterojunction embedded into an elastic polymer matrix. It is discovered that the elastic polymer matrix not only improves the morphology of the bulk heterojunction for obtaining the desired mechanical properties but also alters its electronic band structure and improves the electrical properties that lead to a reduced dark current and enhanced photovoltage in the stretchable photodiode. The work has demonstrated high fidelity measurements and longtime monitoring of heat rate variability and oxygen saturation, potentially enabling next-generation wearable photoplethysmography devices for point-of-care diagnosis of cardiovascular diseases in a more accessible and affordable way.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Validation of an Analytical Model for Therapeutic and Stray Dose Calculations of 6 MV Photon Beams

Cancer is one of the most significant health care problems today. It is estimated that 1 in 2 men and women will be diagnosed with some form of cancer in their lifetime. Nearly two thirds of cancer patients will receive radiation therapy at some point in their care and the vast majority of these radiotherapy treatments will be performed with megavoltage photon therapy. Photon treatment techniques typically devote considerable attention to limiting the exposure of healthy tissues outside of the intended treatment volume. Nonetheless, small levels of unwanted stray radiation are incident upon the patient's whole body, which can increase the risk for numerous late effects, including second malignancies. When one considers that second cancers account for approximately 15% of all cancers and that it is projected that by the year 2020, there will be almost 20 million cancer survivors in the United States and four million in the UK, the need for improved accuracy in stray dose calculations appears likely to increase dramatically. Despite the obvious benefits this capability would afford, contemporary commercial treatment planning systems (TPSs) lack the ability to accurately predict stray dose outside the treatment field, e.g., beyond the 5% isodose surface. Thus, there is a large, variable, and systematic underestimation of stray radiation exposures by commonly used clinical TPSs for photon therapy. To overcome this problem, in a companion paper we proposed a simple, physics-based analytical model that calculates the total therapeutic and stray dose from photon treatment fields. The purpose of this work was to evaluate the accuracy of the basic physics in the analytical absorbed dose model for several simple treatment fields. We assessed the performance of the basic physics in an analytical model that calculates the total absorbed dose deposited by primary, leakage, and scattered photons both inside and outside of square treatment fields of 6 MV photon conventional radiotherapy. The assessment was accomplished by comparing model predictions of total dose with measured dose profiles in a water-phantom. The major finding of this study is that the physics-based model performed well, predicting dose in water within 11.5% dose difference or 5 mm distance to agreement with measured values in the therapeutic region and within 1.1 mGy/Gy or 0.5 mm distance to agreement with measured values in the out-of-field region at 90% of the locations considered. Contemporary external-beam photon TPSs do not include the capability to accurately predict the absorbed dose beyond a few centimeters outside of the treatment field. Our work suggests that it is feasible to improve dosimetric accuracy in the out-of-field region using a simple and computationally fast, physics-based analytical algorithm. This is demonstrated by the measured absorbed dose as well as the corresponding values calculated by two contemporary commercial TPSs (Pinnacle, Philips Health care, Andover, MA and Eclipse, Varian Medical Systems, Inc., Palo Alto, CA) and the analytical model considered in this work. It is apparent that both TPSs underestimated the absorbed dose by greater than 3 mGy/Gy at locations outside of the 0.5% relative dose level. In contrast, the analytical model evaluated in this work calculated absorbed dose in the same region within 0.4 mGy/Gy of measured values. The physics-based analytical dose model could prove useful in a number of different applications. The accurate knowledge of absorbed dose deposited outside of the treatment field is especially important for predicting radiation late effects, such as second cancer, fertility complications, and cardiac toxicity. It may also facilitate predictions of the effects of in utero exposure. We conclude that it is possible to accurately calculate the therapeutic and stray absorbed dose from a conventional radiotherapy treatment field of 6 MV photons using a physics-based analytical model. This was demonstrated by the agreement between measured and calculated doses in water within 11.5% relative dose difference or 5 mm distance to agreement in the therapeutic region, and within 1.1 mGy/Gy absolute dose difference or 0.5 mm distance to agreement in the out-of-field region at 90% of positions for all of the fields considered in this work. This is also illustrated by Figure 4 which plots dose values from analytical model predictions and measurements at five representative irradiation conditions and shows that the analytical model agreement is good in all cases. Furthermore, the model validated in this work evidently can predict dose values with better accuracy at out-of-field locations than contemporary TPSs. This and previous works, taken together, suggest that analytical physics-based models will offer advantages over TPSs or Monte Carlo models for whole-body dose calculations for several radiotherapy applications.

61 RADIATION PROTECTION AND DOSIMETRY↗

Numerical simulation of parametric resonance in point absorbers using a simplified model

Abstract Parametric resonance is a non‐linear phenomenon in which a system can oscillate at a frequency different from its exciting frequency. Some wave energy converters are prone to this phenomenon, which is usually detrimental to their performance. Here, a computationally efficient way of simulating parametric resonance in point absorbers is presented. The model is based on linear potential theory, so the wave forces are evaluated at the mean position of the body. However, the first‐order variation of the body's centres of gravity and buoyancy is taken into account. This gives essentially the same result as a more rigorous approach of keeping terms in the equation of motion up to second order in the body motions. The only difference from a linear model is the presence of non‐zero off‐diagonal elements in the mass matrix. The model is benchmarked against state‐of‐the‐art non‐linear Froude–Krylov and computational fluid dynamics models for free decay, regular wave, and focused wave group cases. It is shown that the simplified model is able to simulate parametric resonance in pitch to a reasonable accuracy even though no non‐linear wave forces are included. The simulation speed on a standard computer is up to two orders of magnitude faster than real time.

16 TIDAL AND WAVE POWER↗

Effect of Anatomical Modeling on Space Radiation Dose Estimates: A Comparison of Doses for NASA Phantoms and 5th, 50th, and 95th Percentile UF Hybrid Phantoms

The estimate of absorbed dose to individual organs of a space crewmember is affected by the geometry of the anatomical model of the astronaut used in the radiation transport calculation. For astronaut dosimetry, NASA currently uses the computerized anatomical male (CAM) and computerized anatomical female (CAF) stylized phantoms to represent astronauts in its operational radiation dose analyses. These phantoms are available in one size and in two body positions. In contrast, the UF Hybrid Adult Male and Female (UFHADM and UFHADF) phantoms have organ shapes based on actual CT data. The surfaces of these phantoms are defined by non-uniform rational B-spline surfaces, and are thus flexible in terms of body morphometry and extremity positioning. In this study, UFHADM and UFHADF are scaled to dimensions corresponding to 5th, 50th, and 95th percentile (PCTL) male and female astronauts. A ray-tracing program is written in Visual Basic 2008, which is then used to create areal density maps for dose points corresponding to various organs within the phantoms. The areal density maps, along with appropriate space radiation spectra, are input into the NASA program couplet HZETRN/BRYNTRN, and organ doses are calculated. The areal density maps selected tissues and organs of the 5th, 50th, and 95th PCTL male and female phantoms are presented and compared. In addition, the organ doses for the 5th, 50th, and 95th PCTL male and female phantoms are presented and compared to organ doses for CAM and CAF.

Bahadori, A.↗

Comparison of Numerical Methods for Modeling the Wave Field Effects Generated by Individual Wave Energy Converters and Multiple Converter Wave Farms

This numerical study compares the wave field generated by the spectral wave action balance code, SNL-SWAN, to the linear-wave boundary-element method (BEM) code, WAMIT. The objective of this study is to assess the performance of SNL-SWAN for modeling wave field effects produced by individual wave energy converters (WECs) and wave farms comprising multiple WECs by comparing results from SNL-SWAN with those produced by the BEM code WAMIT. BEM codes better model the physics of wave-body interactions and thus simulate a more accurate near-field wave field than spectral codes. In SNL-SWAN, the wave field’s energy extraction is modeled parametrically based on the WEC’s power curve. The comparison between SNL-SWAN and WAMIT is made over a range of incident wave conditions, including short-, medium-, and long-wavelength waves with various amounts of directional spreading, and for three WEC archetypes: a point absorber (PA), a pitching flap (PF) terminator, and a hinged raft (HR) attenuator. Individual WECs and wave farms of five WECs in various configuration were studied with qualitative comparisons made of wave height and spectra at specific locations, and quantitative comparisons of the wave fields over circular arcs around the WECs as a function of radial distance. Results from this numerical study demonstrate that in the near-field, the difference between SNL-SWAN and WAMIT is relatively large (between 20% and 50%), but in the far-field from the array the differences are minimal (between 1% and 5%). The resultant wave field generated by the two different numerical approaches is highly dependent on parameters such as: directional wave spreading, wave reflection or scattering, and the WEC’s power curve.

16 TIDAL AND WAVE POWER↗