Rapid 235 U/ 238 U determination by matrix assisted ionization–time-of-flight mass spectrometry

Matrix-assisted ionization (MAI) of inorganic analytes is a nascent research domain that holds promise for rapid, potentially facility-deployable analytical applications. Here, we present results of MAI uranium isotopic analysis ( 235 U/ 238 U) obtained on the timescale of minutes utilizing simple sample preparation and an ambient ionization time-of-flight mass spectrometer (ToF MS). Experimental MAI-ToF MS characterization of uranium Certified Reference Materials (CRMs) was used to establish method calibration and validate quantitative 235 U/ 238 U determination spanning depleted, natural, and low-enriched uranium isotopic compositions. Secondary standard analyses with total uranium mass loadings of 5–500 ng per analysis yield accurate calibrated 235 U/ 238 U results and relative uncertainties of 4.7–17.2% (approx. ±95% confidence level), with weighted-mean uncertainties approaching 1.5%. This method permits accurate determination of uranium isotopic composition in a sample with uranium content as low as 200 pg for equal atom 235 U: 238 U. Instrument detection limits constrain the minimum uranium mass required to identify the presence of highly enriched uranium (HEU ≥20% 235 U) as only 500 pg using the method presented here. MAI-ToF MS quantitation of relatively extreme isotope ratios ( 235 U/ 238 U ≤ 0.01) is limited by detection of minor 235 U (LoD 100 pg 235 U/analysis ≈ 10 ng total U/analysis), and subsequent method optimization is anticipated to further reduce these limits. These findings underscore the potential of MAI-ToF MS for isotopic characterization of uranium and other inorganic species for both basic and applied science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RIMS analysis of isotopically tagged uranium particles with application to Intentional Forensics

Traditional nuclear forensics approaches leverage isotopic measurements for characterizing nuclear forensics signatures in fuel cycle materials. To aid in provenance assessment, isotopically perturbed transition metal taggants can be added to fuel cycle materials. We present a case study for examining natural uranium oxide powder that was tagged with isotopically perturbed Mo before and after irradiation using resonance ionization mass spectrometry. In conclusion, this method accurately and precisely measures taggant and uranium compositions, rapidly enabling the ability to clearly discriminate between tagged particles and other material with application for robust assessment of material provenance.

Forensic Anthropology↗

FRAM, Version 6.1 User Manual

This manual describes the use of version 6.1 of the FRAM gamma-ray isotopic analysis software developed in the Safeguards Science and Technology Group, NEN-1, Nuclear Engineering & Nonproliferation Division, Los Alamos National Laboratory. The software analyzes the gamma ray spectrum from plutonium-bearing items and determines the isotopic distribution of the plutonium, 241Am content, and concentration of other isotopes in the item. The software can also determine the isotopic distribution of uranium isotopes in items containing only uranium. The body of this manual describes the generic version of the code.

07 ISOTOPE AND RADIATION SOURCES↗

Fractionation of Oxygen Isotopes in Uranium Oxides during Peroxide Precipitation and Dry Air Calcination

The interaction between uranium and oxygen-containing substrates is nearly ubiquitous within the nuclear fuel cycle. Given the well-known and predictable oxygen stable isotope compositions of atmospheric oxygen and meteoric waters around the world, the use of these isotopes as a potential geolocation or processing signature of uranium compounds has been of interest within the nuclear safeguards community. This study focuses on measuring the oxygen-stable isotope composition of synthetically produced uranium oxides to determine the mechanism and extent of fractionation during materials processing relevant to the nuclear fuel cycle. Here, metastudtite [UO 2 O 2 (H 2 O) 2 ] samples were first produced using water and hydrogen peroxide of a known oxygen isotope composition. This starting material was calcined in dry air at temperatures ranging from 300 °C to 1000 °C for 20 h producing oxides ranging in composition from UO 3 +x (0 ≤ x ≤ 0.5) to U 3 O 8 . In addition, calcinations between 500 and 800 °C were performed at different time intervals to evaluate the rate of isotopic equilibration. The δ 18 O values of water bound to metastudtite were measured by thermogravimetric analysis coupled to isotope ratio infrared spectroscopy (TGA–IRIS). A redesigned fluorination manifold was constructed at the University of Utah and was used to extract the bulk oxygen from precipitated and calcined products using bromine pentafluoride (BrF 5 ). Mineralization water on metastudtite (measured by TGA–IRIS) was closely associated with the aqueous environment of precipitation with a fractionation of +3.5 ± 0.6‰. In contrast, bulk oxygen from metastudtite (measured by fluorination and gas chromatography combined with isotope ratio mass spectrometry) was found to have an inconsistent fractionation with precipitation water. Samples calcined in dry air exhibited a wide range of oxygen isotope compositions which increased from δ 18 O = +1.4 ± 0.9‰ at 300 °C to +17.3 ± 0.9‰ at 1000 °C. This variation in δ 18 O values was a result of oxygen exchange with atmospheric O 2 and was found to be rapid at calcination temperatures greater than 600°C—with equilibration occurring in less than 2 h. These results provide insights into the incorporation and exchange of oxygen isotopes during precipitation and calcination processes comparable to those employed within the nuclear fuel cycle and establish a foundation for future investigations to build upon.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Cell design for laser-induced breakdown spectroscopy measurements on reactive gas samples

Uranium hexafluoride (UF 6 ) is the primary material used for the enrichment of uranium in the production of light water nuclear reactor fuels worldwide. Accurate, rapid quantification of uranium isotopic composition in nuclear materials is required for safeguards programs and nonproliferation purposes. One potential technique for isotopic measurements in uranium species in the field is laser induced breakdown spectroscopy (LIBS). Safe and effective application of LIBS to UF 6 for enrichment measurements is uniquely challenging due to the chemical and physical properties of UF 6 , which necessitate specific handling procedures. The objective of this work is to design a cell for isotopic analysis of UF 6 that is (1) compatible with chemical and physical properties of UF 6 , (2) compatible with LIBS laser, and (3) portable-sized for nuclear safeguards applications. Along with cell design, initial testing of the cell for basic performance and chemical compatibility is performed. As designed and constructed, the portable gas cell was gas-tight, chemically compatible with UF 6 , and withstood long-duration laser exposure. In this work, the cell has proven capability for handling reactive gasses, such as UF 6 , with specification application to isotopic analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

FRAM v.7.1

Fixed-energy Response-function Analysis with Multiple efficiency (FRAM) is a software code designed primarily for plutonium and uranium isotopic analysis. It is widely used in both the domestic and international safeguards community. FRAM can quickly and accurately determine the isotopic compositions of plutonium, uranium, and mixed oxides (MOX) when measuring with a high-purity germanium (HPGe), cadmium zinc telluride (CZT), or lanthanum bromide (LaBr3) detector. The capabilities of FRAM have been enhanced to analyze the data of the pixelated CZT detector (made by H3D) and to measure the mass of plutonium, uranium, and MOX. Both the isotopic composition and mass of the item can be quickly determined with one measurement using a gamma detector with FRAM v.7.1.

07 ISOTOPE AND RADIATION SOURCES↗

24.1.3.4 Upgraded Fixed Energy Response Function Analysis with Multiple Efficiencies (FRAM) Software for U/Pu/MOX Mass Measurements

Fixed-energy Response-function Analysis with Multiple efficiency (FRAM) is a software code designed primarily for plutonium and uranium isotopic analysis. It is widely used in both the domestic and international safeguards community. FRAM can quickly and accurately determine the isotopic compositions of plutonium, uranium, and mixed oxides (MOX) when measuring with a high-purity germanium (HPGe), cadmium zinc telluride (CZT), or lanthanum bromide (LaBr 3 ) detector. The capabilities of FRAM have been enhanced to analyze the data of the pixelated CZT detector (made by H3D) and to measure the mass of plutonium, uranium, and MOX. Both the isotopic composition and mass of the item can be quickly determined with one measurement using a gamma detector with FRAM v.7.1.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear forensic analysis on uranium ore concentrates: A multi-laboratory intercomparison study

A collaboration between the United States and Japan performed nuclear forensic analyses on a set of 7 uranium ore concentrate (UOC) samples with known origins to improve methodologies and best practices in the field. Overall, good agreement between the 4 participating laboratories was achieved for uranium assay, uranium isotope composition, strontium isotope composition, and trace element analysis. In conclusion, the combination of these four signatures is sufficient to distinguish the different origins among these studied UOCs.

and nuclear chemistry↗

Hyperfine structures and isotopic shifts of uranium transitions using tunable laser spectroscopy of laser ablation plumes

We report isotopic shifts and hyperfine structures of selected U transitions employing tunable spectroscopy viz: laser-induced fluorescence and laser absorption spectroscopy of laser ablation plumes. The laser-produced plasmas were produced during ns laser ablation on a natural U metal which contains 0.7% 235U. Our results show that isotopic shifts between 238U and 235U are entangled with hyperfine structures of 235U. The isotopic ratio obtained using laser-induced fluorescence is affected by optical saturation effect. Time-resolved laser absorption spectroscopy is carried out for evaluating the optical absorption and estimating the hyperfine constants.

(020.3260) Isotope shifts↗

Simultaneous Separation of Protactinium-230 and Uranium-230 Isotopes from a Proton-Irradiated Thorium Matrix

The use of radioisotopes in cancer therapy is becoming increasingly important. As a potential candidate for targeted alpha therapy, 230 U (t 1/2 = 20.8 d), the decay daughter of 230 Pa (t 1/2 = 17.4 d) is currently being investigated for cancer treatment. For radioisotopes to be used in biomedicine, they must be radiochemically pure and free from carrier interference. This can be challenging given their short half-life. Thus, in this study, radiological separation methods for harvesting isotopes for use in biomedicine must be simple, fast, and capable of obtaining the required purity levels. Herein, we demonstrate a new rapid method for the separation of 230 U and 230 Pa from a proton-irradiated 232 Th metal target and from coproduced fission products with high recovery and purity. A dual-column approach was used, in which the first column was an anion exchange (AX) column and the second column was a DGA column. The MP-1 AX resin was used for the primary separation of the three major components (U, Pa, and Th, as well as fission products), and the DGA column was used for further purification of the separated 230 U. The method is simple and allows for straightforward separation of U, Pa, Th, and fission products; also, the entire process from target dissolution to shipment of 230 U could be completed in 3 days with an overall 230 U recovery yield of 96 ± 3%. Additionally, separated 230 Pa fractions can be used to harvest ingrown 230 U after initial separation.

DGA resin↗

Uranium-lead Isotope Evidence in the Shelyabinsk LL5 Chondrite Meteorite for Ancient and Recent Thermal Events

The impact histories on chondrite parent bodies can be deduced from thermochronologic analyses of materials and isotope systems with distinct apparent closure temperatures. It is especially critical to better understand the geological histories and physical properties of potenally hazardous near-Earth asteroids. Chelyabinsk is an LL5 chondrite meteorite that was dispersed over a wide area tens of kilometers south of the town of Chelyabinsk, Russia by an explosion at an altitude of 27 km at 3:22 UT on 15 Feb 2013 [1,2]. The explosion resulted in significant damage to surrounding areas and over 1500 injuries along with meteorite fragments being spread over a wide area [1].

Lapen, T. J.↗

A new highly enriched 233 U reference material for improved simultaneous determination of uranium amount and isotope amount ratios in trace level samples

A highly-enriched 233 U reference material (>0.99987 n( 233 U)/n(U)) has been prepared and characterized for use as an isotope dilution mass spectrometry spike. An ion exchange separation was performed on 1 g of high purity 233 U to further reduce trace amounts of contaminant Pu in the material. The purified 233 U was then prepared as a master solution which was analyzed for molality of uranium by modified Davies and Gray titration. A portion of the master solution was quantitatively diluted and dispensed for reference material units. Selected units were analyzed for verification of uranium amount and to characterize uranium isotope amount ratios by multi-collector inductively couple plasma mass spectrometry. Furthermore, modelling of spike-corrected isotopic data show that the new spike will enable simultaneous measurements of uranium amount and isotope amount ratios with resulting uncertainties that are substantially less sensitive to over spiking than widely used 233 U certified reference materials.

233U↗

Initial Characterization and Optimization of the Liquid Sampling-Atmospheric Pressure Glow Discharge Ionization Source Coupled to an Orbitrap Mass Spectrometer for the Determination of Plutonium

Plutonium measurements are essential to the nuclear forensics and safeguards community. The liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled with an Orbitrap mass spectrometer is a proven platform for uranium isotope ratio determinations. Here, this work expands the LS-APGD-Orbitrap platform capabilities by reporting the first-ever analysis of plutonium with the LS-APGD and the first-ever measurement of elemental plutonium with an Orbitrap mass spectrometer. This coupling has the potential to dramatically reduce the complex sample manipulations required for traditional analysis techniques employed for actinide isotope ratio determinations. As a first step toward the goal of simultaneous uranium and plutonium isotope ratio determinations, the initial characterization and optimization of the platform for the detection of plutonium are reported. Collision-induced dissociation modality settings were optimized to reduce water-related and other molecular clusters containing plutonium, maximizing 242 Pu 16 O 2 + responses. A design of experiments study was conducted to optimize the discharge conditions of the dual-electrode LS-APGD toward the responsivity of 242 Pu 16 O 2 +. The measurement sensitivity was determined from a Pu response curve, yielding a limit of detection of 10 fg (absolute) of total analyte when data was collected and processed with a Spectroswiss FTMS Booster X2 data acquisition system. Additionally, plutonium and uranium were measured in a simultaneous acquisition, and each analyte remained unaffected by the other. It is believed that the LS-APGD-Orbitrap platform could be a valuable addition to the nuclear forensics’ toolbox and, indeed, other scientific disciplines and regulatory communities in which rapid, high-resolution plutonium determinations are paramount.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of ISOCS Measurements to Establish Methodology Uncertainty

Qualification measurements were performed at the US Department of Energy’s (DOE’s) Oak Ridge National Laboratory (ORNL) on a variety of measurement standards. These measurements will be used to qualify the In-Situ Object Counting System (ISOCS) measurement method with a high-purity germanium (HPGe) detector for use at ORNL. Measured items include uranium isotopic standards, filter papers coated with uranium oxide (U 3 O 8 ), U 3 O 8 line sources, and a uranium tetrafluoride (UF 4 ) source. The 235 U mass was estimated using the ISOCS calibration software for each source and compared with the declared isotope mass value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tables for determining lead, uranium, and thorium isotope ages

Tables for determining lead, uranium, and thorium isotope ages are presented in the form of computer printouts. Decay constants, analytical expressions for the functions evaluated, and the precision of the calculations are briefly discussed.

Schonfeld, E.↗

Analysis Report for Hydrolyzed UF 6 Samples

Under the auspices of the US Department of Energy/National Nuclear Security Agency’s Nuclear Reference Material Program (NRMP), the Material Signatures and Isotopic Standards (MSIS) group of Oak Ridge National Laboratory was tasked with analyzing two UF6 filled hoke tubes for uranium isotopic composition. This report documents the results of the measurements performed by the MSIS group’s International Organization for Standardization/International Electrotechnical Commission 17025:2017 accredited operating procedure CSD-AM-CIMS-IN20, Determination of Uranium and Plutonium Isotopic Composition using Thermal Ionization Mass Spectrometry, and in accordance with the quality assurance plan as described in QAP-X-96-CSD/RML-001, Nuclear Analytical Chemistry Laboratory Section Quality Assurance Plan.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗