Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ultrafast laser source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Design and optimization of a modular setup for measurements of three-dimensional spin polarization with ultrafast pulsed sources

ULTRASPIN is an apparatus devoted to the measurement of the spin polarization (SP) of electrons ejected from solid surfaces in a UHV environment. It is designed to exploit ultrafast light sources (free electron laser or laser high harmonic generation) and to perform (photo)electron spin analysis by an arrangement of Mott scattering polarimeters that measure the full SP vector. The system consists of two interconnected UHV vessels: one for surface science sample cleaning treatments, e-beam deposition of ultrathin films, and low energy electron diffraction/AES characterization. The sample environment in the polarimeter allows for cryogenic cooling and in-operando application of electric and magnetic fields. The photoelectrons are collected by an electrostatic accelerator and transport lens that form a periaxial beam that is subsequently directed by a Y-shaped electrostatic deflector to either one of the two orthogonal Mott polarimeters. The apparatus has been designed to operate in the extreme conditions of ultraintense single-X-ray pulses as originated by free electron lasers (up to 1 kHz), but it allows also for the single electron counting mode suitable when using statistical sources such as synchrotron radiation, cw-laser, or e-gun beams (up to 150 kcps).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of a Wollaston interferometry diagnostic on OMEGA EP

Here, a Wollaston interferometer is presented for use in measuring the electron density of plasma plumes created in experiments on the OMEGA EP laser system. The diagnostic is installed as an additional arm on the 4ω probe system, a suite of diagnostics that share a 10 ps pulse of 263 nm laser light captured by an imaging system at f /4. The interferometer utilizes a Wollaston prism to create two angularly separated beams from a single input probe beam, split at any angle between 0° and 90°. This configuration is implemented uniquely such that fringe spacing may be altered independently of field of view, magnification, and imaging resolution, from a range of 17 to 76 μm/fringe. The region of overlap between the two beams forms a total field of view of approximately 1.2 × 1.6 mm at the target chamber center with an imaging resolution of 5 μm. Using this configuration, here it is shown that plasma density may be accurately characterized over a range of 3 × 10 18 –1 × 10 20 cm -3 .

47 OTHER INSTRUMENTATION↗

Unraveling the Solid-Liquid-Vapor Phase Transition Dynamics at the Atomic Level with Ultrafast X-Ray Absorption Near-Edge Spectroscopy

X-ray absorption near-edge spectroscopy (XANES) is a powerful probe of electronic and atomic structures in various media, ranging from molecules to condensed matter. We show how ultrafast time resolution opens new possibilities to investigate highly nonequilibrium states of matter including phase transitions. Based on a tabletop laser-plasma ultrafast x-ray source, we have performed a time-resolved ({approx}3 ps) XANES experiment that reveals the evolution of an aluminum foil at the atomic level, when undergoing ultrafast laser heating and ablation. X-ray absorption spectra highlight an ultrafast transition from the crystalline solid to the disordered liquid followed by a progressive transition of the delocalized valence electronic structure (metal) down to localized atomic orbitals (nonmetal--vapor), as the average distance between atoms increases.

07 ISOTOPE AND RADIATION SOURCES↗

Thermal limit to the intrinsic emittance from metal photocathodes

Measurements of the intrinsic emittance and transverse momentum distributions obtained from a metal (antimony thin film) photocathode near and below the photoemission threshold are presented. Measurements show that the intrinsic emittance is limited by the lattice temperature of the cathode as the incident photon energy approaches the photoemission threshold. A theoretical model to calculate the transverse momentum distributions near this photoemission threshold is presented. An excellent match between the experimental measurements and the theoretical calculations is demonstrated. These measurements are relevant to low emittance electron sources for Free Electron Lasers and Ultrafast Electron Diffraction experiments.

43 PARTICLE ACCELERATORS↗

Advances in ultrafast gas-phase x-ray scattering

Recent developments of x-ray free electron lasers and pulsed electron sources have enabled ultrafast scattering to become an increasingly powerful tool for exploring molecular dynamics. Here, this article describes our recent experimental and methodological advances in ultrafast gas-phase x-ray scattering experiments at the LCLS. A re-designed short-pathlength windowless diffractometer is coupled with careful optimization of sample density and independent normalization of x-ray intensity fluctuations to provide gas-phase scattering patterns with exceptionally high signal-to-noise ratios. These advances, coupled with careful geometry optimization and data treatment, provide both ground- and excited-state signals in excellent agreement with high level ab initio total scattering patterns.

74 ATOMIC AND MOLECULAR PHYSICS↗

Oxide– and Silicate–Water Interfaces and Their Roles in Technology and the Environment

Interfacial reactions drive all elemental cycling on Earth and play pivotal roles in human activities such as agriculture, water purification, energy production and storage, environmental contaminant remediation, and nuclear waste repository management. The onset of the 21st century marked the beginning of a more detailed understanding of mineral aqueous interfaces enabled by advances in techniques that use tunable high-flux focused ultrafast laser and X-ray sources to provide near-atomic measurement resolution, as well as by nanofabrication approaches that enable transmission electron microscopy in a liquid cell. This leap into atomic- and nanometer-scale measurements has uncovered scale-dependent phenomena whose reaction thermodynamics, kinetics, and pathways deviate from previous observations made on larger systems. A second key advance is new experimental evidence for what scientists hypothesized but could not test previously, namely, interfacial chemical reactions are frequently driven by “anomalies” or “non-idealities” such as defects, nanoconfinement, and other nontypical chemical structures. Third, progress in computational chemistry has yielded new insights that allow a move beyond simple schematics, leading to a molecular model of these complex interfaces. In combination with surface-sensitive measurements, we have gained knowledge of the interfacial structure and dynamics, including the underlying solid surface and the immediately adjacent water and aqueous ions, enabling a better definition of what constitutes the oxide– and silicate–water interfaces. This critical review discusses how science progresses from understanding ideal solid–water interfaces to more realistic systems, focusing on accomplishments in the last 20 years and identifying challenges and future opportunities for the community to address. Further, we anticipate that the next 20 years will focus on understanding and predicting dynamic transient and reactive structures over greater spatial and temporal ranges as well as systems of greater structural and chemical complexity. Closer collaborations of theoretical and experimental experts across disciplines will continue to be critical to achieving this great aspiration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Controlled Injection of Electrons for Improved Performance of Laser-Wakefield Acceleration

Our lab performed a series of experiments on controlled injection of LWFA with two extreme laser pulses: one laser pulse was used to drive LWFA. In contrast, the other precisely controls the injection of electrons into the wakefield plasma wave. We have demonstrated an efficient reduction of electron beam emittance by optical injection and novel spatio-temporal manipulation of the electron beam by the extreme laser-plasma waves. Moreover, the optical injection process involves unprecedented new physics, which will benefit studies in astrophysics, inertial confinement fusion, laser-driven x-ray light sources, and ultrafast science. We further improved the performance of LWFA by a better understanding and control of the extreme laser-plasma wave dynamics for optical injection. Three novel mechanisms were identified in the optical injection process: (1) collision of two laser pulses, (2) collision of a laser pulse with a wakefield plasma wave, and (3) collision of two laser wakefields. All three methods improved electron-beam energy spread, emittance, stability, and reproducibility. First, we identified, compared, and independently controlled these different injection mechanisms by controlling the polarization of the injector laser pulse. Second, we manipulated the spatiotemporal splitting of LWFA electron beams to reduce their emittance. Third, we applied the same laser-plasma-wave dynamics and the same experimental setup for improved performance of ion acceleration, which has also been predicted by the recent simulations.

43 PARTICLE ACCELERATORS↗

Open-source simulation program for extreme ultraviolet and soft x-ray sources based on high-harmonic generation

Light sources based on high-harmonic generation (HHG) underpin ultrafast spectroscopy experiments across a large range of photon energies, spanning from the extreme ultraviolet to the soft x-ray. To this day, their design, implementation, and improvement presens unique challenges, but can be aided by numerical tools. Here we present a new simulation program designed for this purpose, which takes both macroscopic and microscopic aspects of high-harmonic generation into account and is therefore applicable across the broad range of parameters which HHG based light sources are today utilized. The program is validated by comparison with published experimental results and by calculating harmonic emission in four common experimental configurations.

Femtosecond lasers↗

A compact electron source for the dielectric laser accelerator

In this work, we design and demonstrate a compact electron source that combines an integrated silicon nanotip photoemitter with a compact silicon-based electrostatic lens. The lens simultaneously accelerates electrons to 30 keV and focuses the resulting beam to a 0.4 μm (RMS) beam diameter with 62 pm-rad normalized emittance at a distance of 20 mm from the cathode. The compact nature of this lens provides a compelling source for dielectric laser accelerator (DLA) beamlines, ultrafast electron diffraction, or ultrafast electron microscopy. Driven by a 220 fs, 1960 nm pulsed laser beam, electron currents up to 28 electrons/pulse at 100 kHz are demonstrated. The electron bunch length is 540 ± 50 fs for photocurrents of <1 electron/pulse, increasing to 700 ± 80 fs for 28 electrons/pulse, as measured by cross correlation with a 220 fs pulsed laser beam. The maximum 5D peak brightness is measured to be 6.8 × 10 13 A/(m 2 rad 2 ) at 28 electrons/pulse. These results represent a significant step toward developing practical benchtop-sized linear accelerators based on DLA technology or compact ultrafast electron microscopy and diffraction applications.

47 OTHER INSTRUMENTATION↗

Development of Ultrafast Capabilities for X-ray Free-Electron Lasers at the Linac Coherent Light source

The ability to produce ultra-short, high-brightness X-ray pulses is revolutionizing the field of ultra-fast X-ray spectroscopy. Free electron laser (FEL) facilities are driving this revolution, but unique aspects of the FEL process make the required characterization and use of the pulses challenging. In this paper, we describe a number of developments in the generation of ultra-short X-ray FEL pulses, and the concomitant progress in the experimental capabilities necessary for their characterization and use at the Linac Coherent Light Source. This includes the development of sub-femtosecond hard and soft X-ray pulses, along with ultra-fast characterization techniques for these pulses. We also describe improved techniques for optical cross-correlation as needed to address the persistent challenge of external optical laser synchronization with these ultra-short X-ray pulses.

Coffee, Ryan N↗

Electron beam-based sources of ultrashort x-ray pulses.

A review of various methods for generation of ultrashort x-ray pulses using relativistic electron beam from conventional accelerators is presented. Both spontaneous and coherent emission of electrons is considered. The importance of the time-resolved studies of matter at picosecond (ps), femtosecond (fs), and atttosecond (as) time scales using x-rays has been widely recognized including by award of a Nobel Prize in 1999 [Zewa]. Extensive reviews of scientific drivers can be found in [BES1, BES2, BES3, Lawr, Whit]. Several laser-based techniques have been used to generate ultrashort x-ray pulses including laser-driven plasmas [Murn, Alte, Risc, Rose, Zamp], high-order harmonic generation [Schn, Rund, Wang, Arpi], and laser-driven anode sources [Ande]. In addition, ultrafast streak-camera detectors have been applied at synchrotron sources to achieve temporal resolution on the picosecond time scale [Wulf, Lind1]. In this paper, we focus on a different group of techniques that are based on the use of the relativistic electron beam produced in conventional accelerators. In the first part we review several techniques that utilize spontaneous emission of electrons and show how solitary sub-ps x-ray pulses can be obtained at existing storage ring based synchrotron light sources and linacs. In the second part we consider coherent emission of electrons in the free-electron lasers (FELs) and review several techniques for a generation of solitary sub-fs x-ray pulses. Remarkably, the x-ray pulses that can be obtained with the FELs are not only significantly shorter than the ones considered in Part 1, but also carry more photons per pulse by many orders of magnitude.

43 PARTICLE ACCELERATORS↗

Using Lasers and X-rays to Reveal the Motion of Atoms and Electrons (LBNL Summer Lecture Series)

Summer Lecture Series 2009: The ultrafast motion of atoms and electrons lies at the heart of chemical reactions, advanced materials with exotic properties, and biological processes such as the first event in vision. Bob Schoenlein, Deputy Director for Science at the Advanced Light Source, will discuss how such processes are revealed by using laser pulses spanning a millionth of a billionth of a second, and how a new generation of light sources will bring the penetrating power of x-rays to the world of ultrafast science.

43 PARTICLE ACCELERATORS↗

Developing Laser-Induced Re-Collision Electron Self-Diffraction (Brief summary of accomplishments)

Our principal goal was the experimental demonstration of Laser-Induced Electron Diffraction (LIED). Key steps along the development of this experimental technique have been accomplished and reported in the publications listed in this brief report. We started with measuring 3D electron momenta spectra in aligned nitrogen and oxygen molecules. Chakra Maharjan (Ph.D. student of Lew Cocke) was a lead researcher on this project. Although Chakra succeeded in obtaining those spectra, we were scooped by the publication of identical results in Science by the NRC Ottawa group. Our results were never published as a refereed article, but became a part of Chakra's Ph.D. dissertation. That Science paper was the first experimental demonstration of Laser-Induced Electron Diffraction (LIED). Chakra also worked on wavelength dependence of 3D ATI spectra of atoms and molecules using tunable OPA pulses. Another Ph.D. student, Maia Magrakvelidze (her GRA was funded by the grant), started working on COLTRIMS experiments using OPA pulses (1800 nm wavelength). After some initial experiments it became apparent that COLTRIMS did not yield sufficient count rates of electrons in the high-energy part of the spectrum to see diffraction signatures with acceptable statistics (unfavorable scaling of the electron yield with laser wavelength was partly to blame). Nevertheless, Maia managed to use COLTRIMS and OPA to measure the angular dependence of the tunneling ionization rate in D 2 molecules. Following the initial trial experiments, the decision was made to switch from COLTRIMS to VMI in order to increase the count rates by a factor of ~100, which may have given us a chance to see LIED. Research Associate Dr. Sankar De (his salary was funded by the grant), in collaboration with Matthias Kling's group (then at MPQ Garching), proceeded to design a special multi-electrode VMI spectrometer for capturing high-energy ATI electrons and to install it in place of COLTRIMS inside our experimental chamber. That apparatus was later used for the first demonstration of field-free orientation in CO using two-color laser pulses as well as for a series of other experiments, such as pump-probe studies of molecular dynamics with few-cycle laser pulses, control of electron localization in dissociating hydrogen molecules using two-color laser pulses, and ATI spectra of Xe ionized by two-color laser pulses. In parallel, Dipanwita Ray (Ph.D. student of Lew Cocke) worked on measuring angle-resolved ATI spectra of noble gases using a stereo-ATI phasemeter as a TOF electron spectrometer. She observed the angular diffraction structures in 3D ATI spectra of Ar, Kr and Xe, which were interpreted in terms of the Quantitative Rescattering theory newly developed by C.D. Lin. We also attempted to use a much more powerful OPA (five times more energy per pulse than the one we had at JRML) available at the Advanced Laser Light Source (ALLS) in Montreal to observe LIED. Two visits to ALLS by the PI, Igor Litvinyuk, and one visit by the PI's Ph.D. student (Irina Bocharova) were funded by the grant. Though we failed to observe LIED (the repetition rate of the ALLS OPA was too low at only 100 Hz), this international collaboration resulted in several publications on other related subjects, such as the wavelength dependence of laser Coulomb explosion of hydrogen, the wavelength dependence of non-sequential double ionization of neon and argon, the demonstration of charge-resonance enhanced ionization in CO 2 , and the study of non-elastic scattering processes in H 2 }. Theoretical efforts to account for the hydrogen Coulomb explosion experiment resulted in another paper by Maia Magrakvelidze as lead author. Although for various reasons we failed to achieve our main goal of observing LIED, we salute the recent success in this endeavor by Lou DiMauro's group (with theoretical support from our KSU colleague C.D. Lin) published in Nature, which validates our approach.

08 HYDROGEN↗

Double conical crystal x-ray spectrometer for high resolution ultrafast x-ray absorption near-edge spectroscopy of Al K edge

An x-ray spectrometer devoted to dynamical studies of transient systems using the x-ray absorption fine spectroscopy technique is presented in this article. Using an ultrafast laser-induced x-ray source, this optical device based on a set of two potassium acid phthalate conical crystals allows the extraction of x-ray absorption near-edge spectroscopy structures following the Al absorption K edge. The proposed experimental protocol leads to a measurement of the absorption spectra free from any crystal reflectivity defaults and shot-to-shot x-ray spectral fluctuation. According to the detailed analysis of the experimental results, a spectral resolution of 0.7 eV rms and relative fluctuation lower than 1% rms are achieved, demonstrated to be limited by the statistics of photon counting on the x-ray detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrafast supercontinuum fiber-laser based pump-probe scanning magneto-optical Kerr effect microscope for the investigation of electron spin dynamics in semiconductors at cryogenic temperatures with picosecond time and micrometer spatial resolution

We describe a two-color pump-probe scanning magneto-optical Kerr effect microscope which we have developed to investigate electron spin phenomena in semiconductors at cryogenic temperatures with picosecond time and micrometer spatial resolution. The key innovation of our microscope is the usage of an ultrafast “white light” supercontinuum fiber-laser source which provides access to the whole visible and near-infrared spectral range. Our Kerr microscope allows for the independent selection of the excitation and detection energy while avoiding the necessity to synchronize the pulse trains of two separate picosecond laser systems. The ability to independently tune the pump and probe wavelength enables the investigation of the influence of excitation energy on the optically induced electron spin dynamics in semiconductors. We demonstrate picosecond real-space imaging of the diffusive expansion of optically excited electron spin packets in a (110) GaAs quantum well sample to illustrate the capabilities of the instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: A novel normalization scheme for laser-based plasma x-ray sources

A kHz repetition rate laser pump-X-ray probe system for ultrafast X-ray diffraction is set up based on a laser-driven plasma X-ray source. A simple and reliable normalization approach has been developed to minimize the impact of large X-ray pulse intensity fluctuation on data quality. It utilizes one single X-ray area detector to record both sample and reference signals simultaneously. Performance of this novel normalization method is demonstrated in reflectivity oscillation measurement of a superlattice sample at sub-ps resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of high-repetition-rate laser pump/x-ray probe methodologies for synchrotron facilities

We describe our implementation of a high repetition rate (54 kHz-6.5 MHz), high power (>10 W), laser system at the 7ID beamline at the Advanced Photon Source for laser pump/x-ray probe studies of optically driven molecular processes. Laser pulses at 1.06 {mu}m wavelength and variable duration (10 or 130 ps) are synchronized to the storage ring rf signal to a precision of {approx}250 fs rms. Frequency doubling and tripling of the laser radiation using nonlinear optical techniques have been applied to generate 532 and 355 nm light. We demonstrate that by combining a microfocused x-ray probe with focused optical laser radiation the requisite fluence (with <10 {mu}J/pulse) for efficient optical excitation can be readily achieved with a compact and commercial laser system at megahertz repetition rates. We present results showing the time-evolution of near-edge x-ray spectra of a well-studied, laser-excited metalloporphyrin, Ni(II)-tetramesitylporphyrin. The use of high repetition rate, short pulse lasers as pump sources will dramatically enhance the duty cycle and efficiency in data acquisition and hence capabilities for laser-pump/x-ray probe studies of ultrafast structural dynamics at synchrotron sources.

36 MATERIALS SCIENCE↗