Uncertainty analysis of correlated parameters in automated reaction mechanism generation

Abstract Uncertainty analysis is a useful tool for inspecting and improving detailed kinetic mechanisms because it can identify the greatest sources of model output error. Owing to the very nonlinear relationship between kinetic and thermodynamic parameters and computed concentrations, model predictions can be extremely sensitive to uncertainties in some parameters while uncertainties in other parameters can be irrelevant. Error propagation becomes even more convoluted in automatically generated kinetic models, where input uncertainties are correlated through kinetic rate rules and thermodynamic group values. Local and global uncertainty analyses were implemented and used to analyze error propagation in Reaction Mechanism Generator (RMG), an open‐source software for generating kinetic models. A framework for automatically assigning parameter uncertainties to estimated thermodynamics and kinetics was created, enabling tracking of correlated uncertainties. Local first‐order uncertainty propagation was implemented using sensitivities computed natively within RMG. Global uncertainty analysis was implemented using adaptive Smolyak pseudospectral approximations as implemented in the MIT Uncertainty Quantification Library to efficiently compute and construct polynomial chaos expansions to approximate the dependence of outputs on a subset of uncertain inputs. Cantera was used as a backend for simulating the reactor system in the global analysis. Analyses were performed for a phenyldodecane pyrolysis model. Local and global methods demonstrated similar trends; however, many uncertainties were significantly overestimated by the local analysis. Both local and global analyses show that correlated uncertainties based on kinetic rate rules and thermochemical groups drastically reduce a model's degrees of freedom and have a large impact on the determination of the most influential input parameters. These results highlight the necessity of incorporating uncertainty analysis in the mechanism generation workflow.

Gao, Connie W.↗

Visual Scanning Hartmann Optical Tester (VSHOT) Uncertainty Analysis (Milestone Report)

In 1997, an uncertainty analysis was conducted of the Video Scanning Hartmann Optical Tester (VSHOT). In 2010, we have completed a new analysis, based primarily on the geometric optics of the system, and it shows sensitivities to various design and operational parameters. We discuss sources of error with measuring devices, instrument calibrations, and operator measurements for a parabolic troughmirror panel test. These help to guide the operator in proper setup, and help end-users to understand the data they are provided. We include both the systematic (bias) and random (precision) errors for VSHOT testing and their contributions to the uncertainty. The contributing factors we considered in this study are: target tilt; target face to laser output distance; instrument vertical offset;laser output angle; distance between the tool and the test piece; camera calibration; and laser scanner. These contributing factors were applied to the calculated slope error, focal length, and test article tilt that are generated by the VSHOT data processing. Results show the estimated 2-sigma uncertainty in slope error for a parabolic trough line scan test to be +/-0.2 milliradians;uncertainty in the focal length is +/- 0.1 mm, and the uncertainty in test article tilt is +/- 0.04 milliradians.

14 SOLAR ENERGY↗

Pretest uncertainty analysis for chemical rocket engine tests

A parametric pretest uncertainty analysis has been performed for a chemical rocket engine test at a unique 1000:1 area ratio altitude test facility. Results from the parametric study provide the error limits required in order to maintain a maximum uncertainty of 1 percent on specific impulse. Equations used in the uncertainty analysis are presented.

Davidian, Kenneth J.↗

Uncertainty Quantification Study of CTF for the OECD/NEA LWR Uncertainty Analysis in Modeling Benchmark

This work describes the results of a quantitative uncertainty analysis of the thermal-hydraulic subchannel code for nuclear engineering applications, Coolant Boiling in Rod Arrays-Three Field (COBRA-TF). CTF is used, which is a version of COBRA-TF developed in cooperation between the Consortium for Advanced Simulation of Light Water Reactors and North Carolina State University. Four steady-state cases from Phase II Exercise 3 of the Organisation for Economic Co-operation and Development/Nuclear Energy Agency Light Water Reactor Uncertainty Analysis in Modeling (UAM) Benchmark are analyzed using the statistical analysis tool, Design Analysis Kit for Optimization and Terascale Applications (Dakota). The input parameters include boundary condition, geometry, and modeling uncertainties, which are selected using a sensitivity study and then defined based on expert judgment. Here, a forward uncertainty quantification method with Latin hypercube sampling (LHS) is used, where the sample size is based on available computational resources.

42 ENGINEERING↗

UNCERTAINTY ANALYSIS FOR THE TECHA RIVER DOSIMETRY SYSTEM

Uncertainties in the doses estimated for the members of the Techa River Cohort (TRC) are being estimated with a two-dimensional Monte Carlo approach. In order to provide more accurate and precise estimates of individual dose (and thus more precise estimates of radiation risk) for the members of the TRC, a new dosimetric calculation system, the Techa River Dosimetry System-2009 (TRDS-2009) has been prepared. The deterministic version of the improved dosimetry system TRDS-2009D was basically completed in April 2009. Recent developments in evaluation of dose-response models in light of uncertain dose have highlighted the importance of different types of uncertainties in the development of individual dose estimates. These include uncertain parameters that may be either shared (common to some or all individuals) or unshared (a unique value for each person whose dose is to be estimated) within the dosimetric cohort. The nature of the type of uncertainty may be aleatory (random variability of true values due to stochastic processes) or epistemic (due to lack of complete knowledge about a unique quantity). Finally, there is a need to identify whether the structure of the errors is either related to measurement (the estimate differs from the true value by an error that is stochastically independent of the true value; frequently called classical uncertainty) or related to grouping (the true value varies from the estimate by an error that is random and is independent of the estimate; frequently called Berkson uncertainty). An approach has been developed that identifies the nature of the various input parameters and calculational methods incorporated in the Techa River Dosimetry System (based on the TRDS-2009D implementation), and a stochastic calculation model has been prepared to estimate the uncertainties in the dose estimates. This article reviews the concepts of uncertainty analysis, the equations, and input parameters, and then identifies the authors’ interpretations of their general nature. It presents the approach selected so that the stochastic, Monte-Carlo, implementation of the dosimetry system - TRDS-2009MC - provides useful information regarding the uncertainties of the doses.

uncertainty analysis, radiation dosimetry, Techa R↗

Parameter uncertainty analysis of a biokinetic model of caesium

Parameter uncertainties for the biokinetic model of caesium (Cs) developed by Leggett et al. were inventoried and evaluated. The methods of parameter uncertainty analysis were used to assess the uncertainties of model predictions with the assumptions of model parameter uncertainties and distributions. Furthermore, the importance of individual model parameters was assessed by means of sensitivity analysis. The calculated uncertainties of model predictions were compared with human data of Cs measured in blood and in the whole body. It was found that propagating the derived uncertainties in model parameter values reproduced the range of bioassay data observed in human subjects at different times after intake. The maximum ranges, expressed as uncertainty factors (UFs) (defined as a square root of ratio between 97.5th and 2.5th percentiles) of blood clearance, whole-body retention and urinary excretion of Cs predicted at earlier time after intake were, respectively: 1.5, 1.0 and 2.5 at the first day; 1.8, 1.1 and 2.4 at Day 10 and 1.8, 2.0 and 1.8 at Day 100; for the late times (1000 d) after intake, the UFs were increased to 43, 24 and 31, respectively. The model parameters of transfer rates between kidneys and blood, muscle and blood and the rate of transfer from kidneys to urinary bladder content are most influential to the blood clearance and to the whole-body retention of Cs. For the urinary excretion, the parameters of transfer rates from urinary bladder content to urine and from kidneys to urinary bladder content impact mostly. The implication and effect on the estimated equivalent and effective doses of the larger uncertainty of 43 in whole-body retention in the later time, say, after Day 500 will be explored in a successive work in the framework of EURADOS.

61 RADIATION PROTECTION AND DOSIMETRY↗

CASL L1 Milestone Report: CASL.P4.01, Sensitivity and Uncertainty Analysis for CIPS with VIPRE-W and BOA

The CASL Level 1 Milestone CASL.P4.01, successfully completed in December 2011, aimed to 'conduct, using methodologies integrated into VERA, a detailed sensitivity analysis and uncertainty quantification of a crud-relevant problem with baseline VERA capabilities (ANC/VIPRE-W/BOA).' The VUQ focus area led this effort, in partnership with AMA, and with support from VRI. DAKOTA was coupled to existing VIPRE-W thermal-hydraulics and BOA crud/boron deposit simulations representing a pressurized water reactor (PWR) that previously experienced crud-induced power shift (CIPS). This work supports understanding of CIPS by exploring the sensitivity and uncertainty in BOA outputs with respect to uncertain operating and model parameters. This report summarizes work coupling the software tools, characterizing uncertainties, and analyzing the results of iterative sensitivity and uncertainty studies. These studies focused on sensitivity and uncertainty of CIPS indicators calculated by the current version of the BOA code used in the industry. Challenges with this kind of analysis are identified to inform follow-on research goals and VERA development targeting crud-related challenge problems.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Prioritizing Nuclear Data Needs Using Uncertainty Analysis

Nuclear security modeling applications can often depend on very different types of lower fidelity data with significant gaps and inconsistencies. Analyzing the impact of these uncertainties on specific nuclear materials, configurations, and detection technologies provides valuable insight when determining where data improvements are needed the most. This paper describes the development and application of emerging uncertainty analysis tools that can be used to perform nuclear data uncertainty analysis and to identify and rank the impacts of individual nuclear data on national security applications. These tools constitute the framework of a comprehensive data uncertainty analysis capability that can provide improved quantitative and objective information on nuclear data needs. This information can be used to augment subject matter expert judgement. This cross-cutting research and development (R&D) capability can be applied to identify gaps and weaknesses in nuclear data to help prioritize future data investments. This in turn can help maximize benefits for specific agency missions. Lessons learned from the analysis of an illustrative example problem involving the measurement of plutonium in a neutron multiplicity counter are described herein, and areas for further methods and nuclear data uncertainty data development are provided.

Wieselquist, William↗

IAEA CRP on HTGR Uncertainty Analysis: Benchmark Definition and Test Cases

Uncertainty and sensitivity studies are essential elements of the reactor simulation code verification and validation process. Although several international uncertainty quantification activities have been launched in recent years in the LWR, BWR and VVER domains (e.g. the OECD/NEA BEMUSE program, from which the current OECD/NEA LWR Uncertainty Analysis in Modelling (UAM) benchmark effort was derived), the systematic propagation of uncertainties in cross-section, manufacturing and model parameters for High Temperature Reactor (HTGR) designs has not been attempted yet. This paper summarises the scope, objectives and exercise definitions of the IAEA Coordinated Research Project (CRP) on HTGR UAM. Note that no results will be included here, as the HTGR UAM benchmark was only launched formally in April 2012, and the specification is currently still under development.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effect of Nuclear Data Covariances on Integral Experiment Design with Sensitivity and Uncertainty Analysis

Washington River Protection Solutions (WRPS) uses MCNP6.2 and the Whisper code for criticality safety analyses of the Hanford Tank Farm. Together the codes derive baseline upper subcritical limits (USLs) for the waste models using experimental benchmarks. Whisper returns higher USLs, i.e. , has less of a conservative penalty, when the neutronic similarity of the experimental benchmarks to the application is high. Unfortunately, few critical benchmarks have high similarity to the Hanford tanks. The waste in the tanks is highly dilute in plutonium and contains large masses of weakly neutron-absorbing elements like iron and manganese. Experimental benchmarks typically have low sensitivity to these absorbers because they are present as structural materials. Lacking similar benchmarks, new Thermal Epithermal eXperiment (TEX) configurations with high Pu content and interstitial iron absorbers have been designed for the criticality safety validation. The features of the design have been iterated upon to maximize the similarity between the experiment and different Hanford waste models. The similarity is quantified with sensitivity analysis and uncertainty quantification using the representativity coefficient, or c k . The representativity calculation requires nuclear data covariances, which may differ between nuclear data libraries and between library versions. Because of these variations, the optimal design may depend on the nuclear data covariances library. A scenario can be envisioned where an experiment is designed, and c k is maximized, with one set of covariance data. However, when the covariance data is changed, say from ENDF/B-VII.1 to ENDF/B-VIII.0, and the benchmark is used in a criticality safety evaluation, the experiment becomes suboptimal with respect to c k . In this paper, we present how the optimal design of the new TEX experiments varied depending on the nuclear data covariances used to calculate c k . We compare ENDF/B-VII.1 and ENDF/B-VIII.0, as if the library had been updated since the design of the experiment. Additionally, we use JEFF3.3 to simulate if the covariance data of a different library had been used. The results show that the covariances do have an important effect on the designs, less so for thermal systems (where the data are more consistent between evaluations) and more so for epithermal systems where more differences exist.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-615: Plan Comparison Between Photon IMRT and Proton Plans Incorporating Uncertainty Analysis

Purpose: In this study, we investigate the effect of setup uncertainty on DVH calculations which may impact plan comparison. Methods: Treatment plans (6 MV VMAT calculated on Pinnacle TPS) were chosen for different disease sites: brain, prostate, H&N and spine in this retrospective study. A proton plan (PP) using double scattering beams was generated for each selected VMAT plan subject to the same set of dose-volume constraints as in VMAT. An uncertainty analysis was incorporated on the DVH calculations in which isocenter shifts from 1 to 5 mm in each of the ±x, ±y and ±z directions were used to simulate the setup uncertainty and residual positioning errors. A total of 40 different combinations of isocenter shifts were used in the re-calculation of DVH of the PTV and the various OARs for both the VMAT and the corresponding PT. Results: For the brain case, both VMAT and PP are comparable in PTV coverage and OAR sparing, and VMAT is a clear choice for treatment due to its ease of delivery. However, when incorporating isoshifts in DVH calculations, a significant change in dose-volume relationship emerges. For example, both VMAT and PT provide adequate coverage, even with ±3mm isoshift. However, +3mm isoshift results in increase of V40(Lcochlea, VMAT) from 7.2% in the original plan to 45% and V40(R cochlea, VMAT) from 75% to 92%. For protons, V40(Lcochlea, PT) increases from 62% in the initial plan to 75%, while V40(Rcochea, PT) increases from 7% to 26%. Conclusion: DVH alone may not be sufficient to allow an unequivocal decision in plan comparison, especially when two rival plans are very similar in both PTV coverage and OAR sparing. It is a good practice to incorporate uncertainty analysis on photon and proton plan comparison studies to test the plan robustness in plan evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MCNP6 Results for the Phase III Sensitivity Benchmark of the OCED/NEA Expert Group on Uncertainty Analysis for Criticality Safety Assessment

Within the last decade, there has been increasing interest in the calculation of cross section sensitivity coefficients of k eff for integral experiment design and uncertainty analysis. The OECD/NEA has an Expert Group devoted to Sensitivity and Uncertainty Analysis within the Working Party for Nuclear Criticality Safety. This expert group has developed benchmarks to assess code capabilities and performance for doing sensitivity and uncertainty analysis. Phase III of a set of sensitivity benchmarks evaluates capabilities for computing sensitivity coefficients. MCNP6 has the capability to compute cross section sensitivities for k eff using continuous-energy physics. To help verify this capability, results for the Phase III benchmark cases are generated and submitted to the Expert Group for comparison. The Phase III benchmark has three cases: III.1, an array of MOX fuel pins, III.2, a series of infinite lattices of MOX fuel pins with varying pitches, and III.3 two spheres with homogeneous mixtures of UF 4 and polyethylene with different enrichments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Detailed Uncertainty Analysis for Ares I Ascent Aerodynamics Wind Tunnel Database

A detailed uncertainty analysis for the Ares I ascent aero 6-DOF wind tunnel database is described. While the database itself is determined using only the test results for the latest configuration, the data used for the uncertainty analysis comes from four tests on two different configurations at the Boeing Polysonic Wind Tunnel in St. Louis and the Unitary Plan Wind Tunnel at NASA Langley Research Center. Four major error sources are considered: (1) systematic errors from the balance calibration curve fits and model + balance installation, (2) run-to-run repeatability, (3) boundary-layer transition fixing, and (4) tunnel-to-tunnel reproducibility.

Hemsch, Michael J.↗

Measurement Uncertainty Analysis of 6x9 Icing Research Tunnel (IRT)

This paper presents the results of the measurement uncertainty analysis that was performed on the aero-thermal characteristics of the 6- by 9-Foot Icing Research Tunnel (IRT) at the NASA Glenn Research Center. The engineering judgments and statistical methods used to determine the elemental uncertainties are described. Instrumentation uncertainty was quanti ed using MANTUS (Measurement Analysis Tool for Uncertainty in Systems) and instrument speci cation sheets. The Monte Carlo method was used to propagate systematic components of uncertainty in order to quantify the uncertainty of the Variables of Interest (VOI). A detailed description of the Monte Carlo method and the MANTUS tool can be found in the Uncertainty Analysis of the NASA Glenn 8x6 Supersonic Wind Tunnel report [1]. Detailed uncertainty results for test section airspeed and temperature as well as other variables of interest are described within this document.

6x9 Icing Research Tunnel↗

Uncertainty analysis of diffuse-gray radiation enclosure problems: A hypersensitive case study

An uncertainty analysis of diffuse-gray enclosure problems is presented. The genesis was a diffuse-gray enclosure problem which proved to be hypersensitive to the specification of view factors. This genesis is discussed in some detail. The uncertainty analysis is presented for the general diffuse-gray enclosure problem and applied to the hypersensitive case study. It was found that the hypersensitivity could be greatly reduced by enforcing both closure and reciprocity for the view factors. The effects of uncertainties in the surface emissivities and temperatures are also investigated.

Taylor, Robert P.↗

Uncertainty Analysis for a Virtual Flow Meter Using an Air-Handling Unit Chilled Water Valve

A virtual water flow meter is developed that uses the chilled water control valve on an air-handling unit as a measurement device. The flow rate of water through the valve is calculated using the differential pressure across the valve and its associated coil, the valve command, and an empirically determined valve characteristic curve. Thus, the probability of error in the measurements is significantly greater than for conventionally manufactured flow meters. In this paper, mathematical models are developed and used to conduct uncertainty analysis for the virtual flow meter, and the results from the virtual meter are compared to measurements made with an ultrasonic flow meter. Theoretical uncertainty analysis shows that the total uncertainty in flow rates from the virtual flow meter is 1.46% with 95% confidence; comparison of virtual flow meter results with measurements from an ultrasonic flow meter yielded anuncertainty of 1.46% with 99% confidence. The comparable results from the theoretical uncertainty analysis and empirical comparison with the ultrasonic flow meter corroborate each other, and tend to validate the approach to computationally estimating uncertainty for virtual sensors introduced in this study.

Song, Li↗