Search NASA⌕ Search

SEARCH · Search NASA

Results for “VALUATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Hydropower flexibility valuation tool for flow requirement evaluation

Timing of generation is becoming more and more valuable. This creates greater potential tension between environmental and power system objectives since both systems require their own flow patterns. Identifying win–win outcomes in this context requires being able to discuss the value of flexibility across stakeholder groups. This research proposes a two-stage optimization method to understand hydropower flexibility to meet both environmental and power system requirements. The tool simulates the two-settlement market process in the U.S. by maximizing revenues from both the day-ahead and real-time markets, subject to plant operational limits, regulatory flow and ramping requirements, and uncertainties associated with water availability and market prices. The model is formulated as linear programming problems and solved using IBM ILOG CPLEX optimizer. By examining a range of flow requirements, ramping constraints, and storage capacities, the proposed tool shows how to make more informed decisions to weigh the cost of specific flow requirements in the context of the overall license requirements. Results from the case study show that revenue is more sensitive to the ramping constraints than the minimum flow constraints. We also demonstrate that removing flow constraints in a dry month increases monthly revenue by up to 118%, as opposed to only 1% in a wet month. In addition, our results suggest that using a learning-based water flow forecast results in an increase of monthly revenue up to 6.4% compared with persistence forecast.

13 HYDRO ENERGY↗

Valuation of Surface Coatings in High-Energy Density Lithium-ion Battery Cathode Materials

Artificial barriers, usually with either electrochemically active or inactive coating materials, are deployed on cathode material surfaces to mitigate detrimental side reactions by suppressing direct contact of cathode and electrolyte called surface coatings. These surface coatings are commonly known to increase the wettability of liquid electrolyte and reduce the interfacial charge transfer resistance. An important caveat is the selection of appropriate coating material with appropriate thickness for achieving enhanced electrochemical performance. As modern battery materials are increasingly developed with some type of surface coating, a careful and thorough examination of their role in mitigating the cycle life issues of cathode materials is paramount. Here, this comprehensive review article extensively covers the selection criteria of coating materials based on their chemical and physical properties and electrochemical functionalities. Additionally, the article discusses the concept of critical coating thickness and methods of achieving homogeneous coating architectures that deliver desired performance benefits. Furthermore, this comprehensive article summarizes the recent advancements, effectiveness, necessity of cathode surface coatings and identifies the key aspect of structure-property correlation between coating type/thickness and lithium-ion diffusion through coating layers as the linchpin that validates surface coating approaches especially for high capacity nickel-rich cathodes.

25 ENERGY STORAGE↗

Probabilistic Hydropower Flexibility Valuation: Case Studies for Boating Flow Regime

The optimal scheduling of hydropower generation holds significant importance to power system operation. The unique requirements of environmental constraints and the power system, depending on their respective objectives, demand distinct flow patterns. While power system stakeholders strive to optimize revenue in electricity markets, stakeholders from boating recreation seeks to identify flow ranges that optimize the boating experience. In pursuit of a win-win solution, this study aims to reconcile the interests of various stakeholders in hydropower scheduling. The maximum revenue from day-ahead electricity market is explored through an optimization process considering both plant operation constraints, boating flow constraints, water availability, and market prices. Results of real world case studies at a river in California show that the proposed approach can achieve dual objectives: maximizing market revenue while addressing boating recreation necessities. In addition, as the accuracy of electricity price forecasting and flow forecasting increase, the optimal revenue becomes increasingly advantageous to hydropower plant operators.

13 HYDRO ENERGY↗

Economic Valuation of Coccidioidomycosis (Valley Fever) Projections in the United States in Response to Climate Change

Coccidioidomycosis, or valley fever, is an infectious fungal disease currently endemic to the southwestern United States. Symptoms of valley fever range in severity from flu-like illness to severe morbidity and mortality. Warming temperatures and changes in precipitation patterns may cause the area of endemicity to expand northward throughout the western United States, putting more people at risk for contracting valley fever. This may increase the health and economic burdens from this disease. We developed an approach to describe the relationship between climate conditions and valley fever incidence using historical data and generated projections of future incidence in response to both climate change and population trends using the Climate Change Impacts and Risk Analysis (CIRA) framework developed by the U.S. Environmental Protection Agency. We also developed a method to estimate economic impacts of valley fever that is based on case counts. For our 2000–15 baseline time period, we estimated annual medical costs, lost income, and economic welfare losses for valley fever in the United States were 400,000 USD per case, and the annual average total cost was 3.9 billion USD per year. For a high greenhouse gas emission scenario and accounting for population growth, we found that total annual costs for valley fever may increase up to 164% by year 2050 and up to 380% by 2090. By the end of the twenty-first century, valley fever may cost 620,000 USD per case and the annual average total cost may reach $18.5 billion per year. This work contributes to the broader effort to monetize climate change–attributable damages in the United States.

54 ENVIRONMENTAL SCIENCES↗

Valuation and cost reduction of behind-the-meter hydrogen production in Hawaii

A 250kW hydrogen electrolysis facility was recently installed at the Natural Energy Laboratory of Hawaii Authority's (NELHA's) campus. This facility that will begin operation in 2020 to produce hydrogen for fuel cell buses on the island to demonstrate of the application of hydrogen to decarbonize transportation. Given the size of the electrolysis station, it has the potential to significantly increase electricity costs for the campus, which is subject to energy and peak demand charges from the local utility. In this paper, we analyze the cost of hydrogen production at NELHA given the rate structure options available from the utility. Production costs are estimated using optimal versus constant scheduling of the facility to meet the buses’ demand. A model of the electrolysis station is used to capture changes in production efficiency over the power range in the optimization routine. The effects of combining the station and campus load versus standalone operation and increasing solar generation are also explored. The analyses surrounding this scenario show the importance of multiple factors on the potential profitability of hydrogen production in behind-the-meter applications and show trends that could have implications for other similar installations.

08 HYDROGEN↗

Valuation of Hydrogen Technology on the Electric Grid Using Production Cost Modeling: Cooperative Research and Development Final Report, CRADA Number CRD-18-00736

This research project will estimate the value to the United States electric grid of deploying hydrogen technology (such as electrolyzers and hydrogen-fueled generation) under projected conditions of high renewable penetration. The analysis will advance the state of the art in systems-level cost-benefit analysis of hydrogen technology for the electric grid by incorporating production cost modeling results in the analysis. Large-scale grid simulation tools will be used to evaluate total system production cost and grid operation when hydrogen technology is deployed for applications such as energy storage and demand response. Scenarios will include one or more future grid mixes in the Western Interconnect (WI) with a high proportion of intermittent renewables. Electric Power Research Institute (EPRI) will work with four utility companies to refine scenarios. Results of the analysis will include comparing the net cost of hydrogen to other technologies for long duration storage, and of power-to-gas (P2G) scenarios including merchant hydrogen sale and hydrogen-fueled generation.

08 HYDROGEN↗

Mojave firmware 1.09 base-line valuation [Memo]

The inverter firmware was upgraded to version 1.09 and an initial assessment was conducted on the inverter using the equipment listed above and the response of the inverter can be seen in the following plots. This work is to base-line the response of the inverter to utility conditions and commands and further work will involve the interoperability aspect of the inverter using SunSpec dashboard to conduct the tests and configure the inverter.

42 ENGINEERING↗

Mojave firmware 1.09 FW valuation- Firmware 1.09 Results

This quick note outlines what we found after our conversion with you and your team. As suggested, we loaded 1547-2003 source requirements document (SRD) and then went back and loaded 1547-2018 SRD. This did result in implementing the new 1547-2018 settings. This short report focuses on the frequency-watt function and shows a couple of screen shots of the parameter settings via the Mojave HMI interface and plots of the results of the inverter with FW function enabled in both default and most aggressive settings response to frequency events. The first screen shot shows the 1547-2018 selected after selecting 1547-2003.

97 MATHEMATICS AND COMPUTING↗

Modular Control Architecture for Scalable, Resilient, and Cybersecure Microgrids Test Results [Mojave firmware 1.09 FW valuation]

This quick note outlines what we found after our conversion with you and your team. As suggested, we loaded 1547-2003 source requirements document (SRD) and then went back and loaded 1547-2018 SRD. This did result in implementing the new 1547-2018 settings. This short report focuses on the frequency-watt function and shows a couple of screen shots of the parameter settings via the Mojave HMI interface and plots of the results of the inverter with FW function enabled in both default and most aggressive settings response to frequency events. The first screen shot shows the 1547-2018 selected after selecting 1547-2003.

42 ENGINEERING↗

Case Study of the City of Reno: Resilience Valuation and Planning for Solar and Storage on Critical Infrastructure

This case study report documents the City of Reno's efforts to quantify the value of resilience and the entrepreneurial ways through which the City approached the questions of what role solar and storage could play in their resilience efforts and how to value and pay for solar-plus-storage systems. It documents how and why the City of Reno came to the specific conclusion to integrate solar and storage into their Public Safety Center retrofit project and apply for Federal Emergency Management Agency (FEMA) Building Resilient Infrastructure and Communities (BRIC) funding. This report provides an overview for other local governments to draw inspiration from when considering how to prioritize community values and pursue multi-stakeholder dialogue around resilient energy solutions. The City of Reno's experience can serve as a starting point for other communities interested in valuing the resilience benefits of solar and storage.

14 SOLAR ENERGY↗

Resilience Valuation and Planning for Solar and Storage on Critical Infrastructure

This case study report documents the City's project evolution and the entrepreneurial ways through which the City approached the questions of how solar and storage could support their resilience efforts and how to value and pay for solar-plus-storage systems. This report documents how and why the City of Reno came to the specific conclusion to integrate solar and storage into their Public Safety Center retrofit project and apply for Federal Emergency Management Agency (FEMA) Building Resilient Infrastructure and Communities (BRIC) funding. (The City of Reno applied for and was awarded FEMA BRIC funding in January 2021; leveraging work that was underway in this project.) This report provides an overview for other local governments to draw inspiration from when considering how to prioritize community values and pursue multi-stakeholder dialogue around resilient energy solutions. The City of Reno's experience can serve as a starting point for other communities interested in valuing the resilience benefits of solar and storage.

14 SOLAR ENERGY↗