Search NASA⌕ Search

SEARCH · Search NASA

Results for “VC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

High-Power Lithium Metal Batteries Enabled by High-Concentration Acetonitrile-Based Electrolytes with Vinylene Carbonate Additive

To enable next-generation high power, high-energy-density lithium (Li) metal batteries (LMBs), an electrolyte possessing both high Li Coulombic efficiency (CE) at high-rate and good anodic stability on cathodes is critical. Acetonitrile (AN) is a well-known organic solvent for high anodic stability and high ionic conductivity, yet its application in LMBs is limited due to its poor compatibility with Li metal anode even at high salt concentration conditions. Here, we developed a highly concentrated AN-based electrolyte with vinylene carbonate (VC) additive to suppress Li+ depletion at high current densities. Addition of VC in the AN-based electrolyte leads to the formation of a polycarbonate-based solid electrolyte interphase which minimizes Li corrosion and leads to very high Li CE of up to 99.1% at a current density of 0.2 mA cm-2. Using such an electrolyte, fast charging of Li||NMC333 cells has been realized at a high current density of 3.6 mA cm-2, and stable cycling of Li||NMC622 cells with a high cathode loading of 4 mAh cm-2 has also been demonstrated.

Peng, Zhe↗

Intravenous Vitamin C attenuates hemorrhagic shock-related renal injury through the induction of SIRT1 in rats

Highlights: • Intravenous vitamin c attenuates HS related renal injury via the Induction of SIRT1. • NF-Kb and HO-1 could be the downstream of SIRT1. • There were no differences in the effects between the high and low dose of Vitamin C. To investigate the effect of intravenous Vitamin C (VC) on hemorrhagic shock (HS)-associated rat renal injury and the involved mechanism. Thirty SD rats were randomly assigned to the sham surgery (sham), hemorrhagic shock (HS), HS+100 mg/kg VC (H + VL), HS+500 mg/kg VC (H + VH) and HS+100 mg/kg VC + EX527 (H + VL + E) groups. Tissue and blood samples were collected 6 h after surgery. Kidney pathological changes were scored. Creatinine (CRE), blood urea nitrogen (BUN), tumor necrosis factor-α (TNF-α), and interleukin-1β (IL-1β) levels in serum and Vitamin C levels and superoxide dismutase (SOD) activity and the ability to suppress hydroxyl radical (RAFHR) in plasma were measured. The expression of Sirtuin1 (SIRT1), Acetyl-NF-κB (Ace-NF-κB), heme oxygenase-1 (HO-1), TNF-α, and IL-1β in tissues was analyzed by ELISA or western-blot. In the HS group, the kidney pathological score and CRE, BUN, TNF-α, and IL-1β levels in serum were significantly higher than in the Sham group (P P P P P P 0.05). Additionally, MDA, TNF-α, IL-1β and Acetyl-NF-κB expression levels were decreased in the kidney (P < 0.05), while SOD, SIRT1 and HO-1 levels were notably enhanced. There were no differences between the H + VL and H + VH groups aside from plasma Vitamin C levels. The effect of Vitamin C was decreased after the addition of EX527, which inhibits SIRT1. Intravenous Vitamin C might attenuate HS-related renal injury via the SIRT1 pathway, and it appears that there were no differences in the effects between the high and low doses.

60 APPLIED LIFE SCIENCES↗

Venous endothelium reactivity to Angiotensin II: A study in primary endothelial cultures of rat vena cava and portal vein

Highlights: • The venous endothelium is an unexplored site. • Cells from vena cava and portal vein can be isolated and cultured. • Cultures of venous endothelium present differences in growth pattern. • Resting cells from venous endothelium produce nitric oxide and prostanoids. • The venous endothelium is reactive to angiotensin II. The role of the vascular endothelium in modulating the arterial system has been widely investigated, but poorly explored at the venous site. In the present work, primary cultures of venous endothelium from rat Vena Cava (VC) and Portal Vein (PV) were established, characterized and analyzed according to their growth pattern and ability to produce nitric oxide (NO) and prostanoids (PGF{sub 2 α} and PGI{sub 2}), at basal state and after stimulation with Angiotensin II (Ang II, 1 μmol/L). Basal NO was detected in all examined cells in culture. Pre-incubation with Ang II increased NO production in cells from VC (but not in PV cultures), through activation of both AT{sub 1} and AT{sub 2} receptors. Both cultures exhibited detectable levels of PGF{sub 2 α} at resting conditions, which were similarly enhanced by Ang II. Basal PGI{sub 2} levels were higher in PV, but increased after Ang II treatment in VC, with no further effect on PV cells. We conclude that endothelial cells from VC and PV exhibit important properties and react to Ang II, probably influencing the whole circulatory system. This experimental cell model gives support to further studies concerning intracellular pathways of the venous endothelium, analyzed in separate from the vascular smooth muscle wall.

60 APPLIED LIFE SCIENCES↗

Normalized Quantitative PCR Measurements as Predictors for Ethene Formation at Sites Impacted with Chlorinated Ethenes

Quantitative PCR (qPCR) targeting Dehalococcoides mccartyi (Dhc) biomarker genes supports effective management at sites impacted with chlorinated ethenes. To establish correlations between Dhc biomarker gene abundances and ethene formation (i.e., detoxification), 859 groundwater samples representing 62 sites undergoing monitored natural attenuation or enhanced remediation were analyzed. Dhc 16S rRNA genes and the vinyl chloride (VC) reductive dehalogenase genes bvcA and vcrA were detected in 88% and 61% of samples, respectively, from wells with ethene. Dhc 16S rRNA, bvcA , vcrA , and tceA (implicated in cometabolic reductive VC dechlorination) gene abundances all positively correlated with ethene formation. Significantly greater ethene concentrations were observed when Dhc 16S rRNA gene and VC RDase gene abundances exceeded 10 7 and 10 6 copies L –1 , respectively, and when Dhc 16S rRNA- and bvcA + vcrA -to-total bacterial 16S rRNA gene ratios exceeded 0.1%. Dhc 16S rRNA gene-to- vcrA/bvcA ratios near unity also indicated elevated ethene; yet, no increased ethene was observed in 19 wells where vcrA and/or bvcA gene copy numbers exceeded Dhc cell numbers 10- to 10 000-fold. Approximately one-third of samples with detectable ethene lacked bvcA , vcrA , and tceA , implying that comprehensive understanding of VC detoxification biomarkers has not been achieved. Although the current biomarker suite is incomplete, the data analysis corroborates the value of the available Dhc DNA biomarkers for prognostic and diagnostic groundwater monitoring at sites impacted with chlorinated ethenes.

59 BASIC BIOLOGICAL SCIENCES↗

Grape pomace compost harbors organohalide-respiring Dehalogenimonas species with novel reductive dehalogenase genes

Here, organohalide-respiring bacteria play key roles in the natural chlorine cycle; however, most of the current knowledge is based on cultures from contaminated environments. We demonstrate that grape pomace compost without prior exposure to chlorinated solvents harbors a Dehalogenimonas ( Dhgm ) species capable of using chlorinated ethenes, including the human carcinogen and common groundwater pollutant vinyl chloride (VC) as electron acceptors. Grape pomace microcosms and derived solid-free enrichment cultures were able to dechlorinate trichloroethene (TCE) to less chlorinated daughter products including ethene. 16S rRNA gene amplicon and qPCR analyses revealed the predominance of Dhgm sequences, but no Dehalococcoides mccartyi ( Dhc ) biomarker genes were detected. The enumeration of Dhgm 16S rRNA genes demonstrated VC-dependent growth, and 6.55 ± 0.64 x 10 8 cells were produced per µmole of chloride released. Metagenome sequencing enabled the assembly of a Dhgm draft genome, and 52 putative reductive dehalogenase (RDase) genes were identified. Proteomic workflows identified a putative VC RDase with 49% and 56.1% amino acid similarity to the known VC RDases VcrA and BvcA, respectively. A survey of 1,173 groundwater samples collected from 111 chlorinated solvent-contaminated sites revealed that Dhgm 16S rRNA genes were frequently detected and outnumbered Dhc in 65% of the samples. Dhgm may be more relevant contributors to chlorinated solvent reductive dechlorination in contaminated aquifers than is currently recognized, and non-polluted environments are a source of strictly organohalide-respiring bacteria with novel RDase genes.

54 ENVIRONMENTAL SCIENCES↗

How carbon vacancies can affect the properties of group IV color centers in diamond: A study of thermodynamics and kinetics

Recently, there has been much interest in using Group IV elements from the periodic table to fabricate and study XV color centers in diamond, where X=Si, Ge, Sn, or Pb and V is a carbon vacancy. These Group IV color centers have a number of interesting spin and optical properties, which could potentially make them better candidates than NV− centers for important applications in quantum computing and quantum information processing. Unfortunately, the very same ion implantation process that is required to create these XV color centers in diamond necessarily also produces many carbon vacancies (VC), which can form complexes with these color centers (VC−XV) that can dramatically affect the properties of the isolated XV color centers. The main focus of this work is to use density-functional theory to study the thermodynamics and kinetics of the formation of these VC−XV complexes and to suggest experimental ways to impede this process such as varying the Fermi level of the host diamond material through chemical doping or applying an external electrical bias. We also include a discussion of how the simple presence of many VC can negatively impact the spin coherence times (T2) of Group IV color centers through the presence of acoustic phonons.

Kuate Defo, Rodrick↗

Initial Process Planning of a Hybrid Multi-Tasking Platform

Abstract Applications of hybrid technology are expanding from refurbishment and repair to low quantity, specialty part production, which are staple characteristics in medical implant, energy, and aerospace industry sectors, among others. This expansion has led to the development of the Mazak VC-500A/5X AM HWD, a wire fed laser cladding unit equipped with a standard 5 axis CNC. This unit is capable of building near net geometry of complex medium to large parts within a profitable timeframe, due to its comparatively high rate of deposition to that of a powder fed hybrid system. In this study, deposition and machining capabilities of the VC-500A/5X AM HWD are assessed through the production of three different test geometries by different process plans. Production of these test geometries is supported by an open loop sensor package primarily for monitoring machine health, data collection, and machine operator aid. The viability of extended deposition followed by machining is evaluated against a more cyclical strategy of reoccurring deposition and machining operations. Lastly, common defects in as-built geometries are evaluated and addressed through revisions to original process plans and toolpaths, indicating the need for continued innovation in hybrid manufacturing specific CAM/CAD software, as well as closed loop machine monitoring and quality control.

DeWitte, Lisa N.↗

A Systematic Review and Meta-Analysis of Tai Chi Training in Cardiorespiratory Fitness of Elderly People

Objectives. The purpose of this study was to investigate the influence of Tai Chi on cardiorespiratory fitness (CRF) in elderly people using meta-analysis. Methods. This study used seven electronic databases and data retrieved from randomized controlled trials (RCTs) investigating the role of Tai Chi on CRF in the elderly. All these 24 RCTs were screened and selected from 7 literature databases. The Stata 11.2 software (StataCorp, USA) was used for the meta-analysis, subgroup analysis, and bias test, while the Cochrane Collaboration’s tool was used for the assessment of the risk of bias (RoB). 4 researchers independently participated in sample selection, data extraction, and RoB assessment. Results. Following the inclusion criteria, 24 eligible studies were included in our analysis. The meta-analysis indicated that Tai Chi practice significantly increased the maximum rate of oxygen consumption (VO2 max) (weighted mean difference (WMD) = 3.76, 95% CI: 1.25 to 6.26, P < 0.1 ), leading to an overall reduction in the heart rate (HR) (WMD = −1.84, 95% CI: −2.04 to −1.63, P ≤ 0.001 ) and an increase in the O2 pulse (WMD = 0.94, 95% CI: 0.60 to 1.28, P ≤ 0.001 ) in individuals who practiced Tai Chi regularly compared with those who did not. The subgroup analysis suggested that overall in those who practiced Tai Chi, males (WMD = 1.48, 95% CI: 0.85 to 2.12, P ≤ 0.001 ) had higher O2 pulse than females (WMD = 0.73, 95% CI: 0.33 to 1.12, P ≤ 0.001 ). The subgroup analysis also showed an increase in the vital capacity (VC) (WMD = 316.05, 95% CI: 239.74 to 392.35, P ≤ 0.001 ) in individuals practicing Tai Chi. When the samples were further stratified by Tai Chi practicing time, the subgroup analysis suggested that individuals practicing Tai Chi over a period of 24 weeks showed no significant difference in VC (WMD = 82.95, 95% CI: -98.34 to 264.23, P = 0.370 ), while those practicing Tai Chi over a period of 48 weeks showed a significant increase (WMD = 416.62, 95% CI: 280.68 to 552.56, P ≤ 0.001 ). Furthermore, the subgroup analysis demonstrated that the increase in VC is significantly correlated with the Tai Chi practicing time (WMD = 344.97, 95% CI: 227.88 to 442.06, P ≤ 0.001 ). Conclusion. Regular Tai Chi practice could improve the CRF in the elderly, as indicated by significant improvement in indicators including VO2max, O2pulse, VC, and HR. However, gender and practice time might influence the overall beneficial outcomes.

Tan, Tianyang↗

High-Performing PGM-Free AEMFC Cathodes from Carbon-Supported Cobalt Ferrite Nanoparticles

Efficient and durable non-precious metal electrocatalysts for the oxygen reduction reaction (ORR) are highly desirable for several electrochemical devices, including anion exchange membrane fuel cells (AEMFCs). Here, cobalt ferrite (CF) nanoparticles supported on Vulcan XC-72 carbon (CF-VC) were created through a facile, scalable solvothermal method. The nano-sized CF particles were spherical with a narrow particle size distribution. The CF-VC catalyst showed good ORR activity, possessing a half-wave potential of 0.71 V. Although the intrinsic activity of the CF-VC catalyst was not as high as some other platinum group metal (PGM)-free catalysts in the literature, where this catalyst really shined was in operating AEMFCs. When used as the cathode in a single cell 5 cm−2 AEMFC, the CF-VC containing electrode was able to achieve a peak power density of 1350 mW cm−2 (iR-corrected: 1660 mW cm−2) and a mass transport limited current density of more than 4 A cm−2 operating on H2/O2. Operating on H2/Air (CO2-free), the same cathode was able to achieve a peak power density of 670 mW cm−2 (iR-corrected: 730 mW cm−2) and a mass transport limited current density of more than 2 A cm−2. These peak power and achievable current densities are among the highest reported values in the literature to date.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CCSDS Advanced Orbiting Systems Virtual Channel Access Service for QoS MACHETE Model

To support various communications requirements imposed by different missions, interplanetary communication protocols need to be designed, validated, and evaluated carefully. Multimission Advanced Communications Hybrid Environment for Test and Evaluation (MACHETE), described in "Simulator of Space Communication Networks" (NPO-41373), NASA Tech Briefs, Vol. 29, No. 8 (August 2005), p. 44, combines various tools for simulation and performance analysis of space networks. The MACHETE environment supports orbital analysis, link budget analysis, communications network simulations, and hardware-in-the-loop testing. By building abstract behavioral models of network protocols, one can validate performance after identifying the appropriate metrics of interest. The innovators have extended the MACHETE model library to include a generic link-layer Virtual Channel (VC) model supporting quality-of-service (QoS) controls based on IP streams. The main purpose of this generic Virtual Channel model addition was to interface fine-grain flow-based QoS (quality of service) between the network and MAC layers of the QualNet simulator, a commercial component of MACHETE. This software model adds the capability of mapping IP streams, based on header fields, to virtual channel numbers, allowing extended QoS handling at link layer. This feature further refines the QoS v existing at the network layer. QoS at the network layer (e.g. diffserv) supports few QoS classes, so data from one class will be aggregated together; differentiating between flows internal to a class/priority is not supported. By adding QoS classification capability between network and MAC layers through VC, one maps multiple VCs onto the same physical link. Users then specify different VC weights, and different queuing and scheduling policies at the link layer. This VC model supports system performance analysis of various virtual channel link-layer QoS queuing schemes independent of the network-layer QoS systems.

Jennings, Esther H.↗

A Situation Awareness Assistant for Human Deep Space Exploration

This paper presents the development and testing of a Virtual Camera (VC) system to improve astronaut and mission operations situation awareness while exploring other planetary bodies. In this embodiment, the VC is implemented using a tablet-based computer system to navigate through inter active database application. It is claimed that the advanced interaction media capability of the VC can improve situation awareness as the distribution of hu man space exploration roles change in deep space exploration. The VC is being developed and tested for usability and capability to improve situation awareness. Work completed thus far as well as what is needed to complete the project will be described. Planned testing will also be described.

Boy, Guy A.↗

Wilson Corners SWMU 001 2015 Annual Long Term Monitoring Report Kennedy Space Center, Florida

This document presents the findings of the 2015 Long Term Monitoring (LTM) that was completed at the Wilson Corners site, located at the National Aeronautics and Space Administration John F. Kennedy Space Center, Florida. The objectives of the 2015 LTM event were to evaluate the groundwater flow direction and gradient, to monitor the vertical and horizontal extent of the volatile organic compounds (VOCs; including the upgradient and sidegradient extents, which are monitored every five years), and to monitor select locations internal to the dissolved groundwater plume. The 2015 LTM event included several upgradient and sidegradient monitoring wells that are not sampled annually to verify the extent of VOCs in this portion of the site. The December 2015 LTM groundwater sampling event included, depth to groundwater measurements, 40 VOC samples collected using passive diffusion bags, and one VOC sample collected using low-flow techniques. Additionally, monitoring well MW0052DD was overdrilled and abandoned using rotasonic drilling techniques. The following conclusions can be made based on the 2015 LTM results: groundwater flow is generally to the west with northwest and southwest flow components from the water table to approximately 55 feet below land surface (ft BLS); peripheral monitoring wells generally delineate VOCs to groundwater cleanup target levels (GCTLs) except for monitoring wells MW0088, MW0090, MW0095, and NPSHMW0039, which had vinyl chloride (VC) concentrations near the GCTL and MW0062, which had trichloroethene (TCE), cis-1,2-dichloroethenen (cDCE), and VC concentrations above natural attenuation default concentrations (NADCs); VOCs in interior downgradient wells generally fluctuate within historic ranges except for monitoring wells in the north-northwest portion of the site, which have increasing VC concentrations indicating potential plume migration and expansion; Historically, the vertical extents of the VOCs were delineated by monitoring wells screened greater than 60 ft BLS (MW0083 through MW0086, and MW0078). The 2015 LTM results indicate that concentrations of daughter product cDCE is greater than the NADC in MW0078 and that cDCE and VC are greater than NADCs in MW0130. TCE was greater than the GCTL in monitoring well MW130 and not detected above method detection limits (9 micrograms per Liter) in monitoring well MW0078. No GCTL exceedances were identified in monitoring wells MW0083 or MW0086; the dissolved plume footprint appears generally stable, though not fully delineated by monitoring well data in the northeast portion of the site; and 2015 LTM results generally support the existing Conceptual Site Model. Geosyntec recommends modifying the LTM program, collecting a verification sample from monitoring well MW0062, and performing a direct push technology instigation in the northnortheastern portion of the site. A cluster of monitoring wells (MW0132 [2 to 12 ft BLS], MW0133 [15 to 25 ft BLS], and MW0134 [29 to 34 ft BLS]) is proposed to delineate impacts in the northnortheast portion of the site. Geosyntec recommends installation of a vertical extent well in the center of the site (Hot Spot 2 area) post-remediation implementation.

groundwater↗

Supply Warehouse#3, SWMU 088 Operations, Maintenance, and Monitoring Report Kennedy Space Center, Florida

This document presents the findings, observations, and results associated with Operations, Maintenance, and Monitoring (OM&M) activities of Corrective Measures Implementation (CMI) activities conducted at Supply Warehouse #3 (SW3) located at John F. Kennedy Space Center (KSC), Florida from October 8, 2015, to September 12, 2016, and performance monitoring results for semi-annual sampling events conducted in March and September 2016. The primary objective of SW3 CMI is to actively decrease concentrations of trichloroethene (TCE) and vinyl chloride (VC) to less than Florida Department of Environmental Protection (FDEP) Natural Attenuation Default Concentrations (NADCs), and the secondary objective is to reduce TCE, cis-1,2-dichloroethene (cDCE), trans-1,2-dichloroethene (tDCE), 1,1-dichloroethene (11DCE), and VC concentrations to less than FDEP Groundwater Cleanup Target Levels (GCTLs). The SW3 facility has been designated Solid Waste Management Unit (SWMU) 088 under KSC's Resource Conservation and Recovery Act (RCRA) Corrective Action Program. Based on the results to date, the SW3 air sparging (AS) system is operating at or below the performance criteria as presented in the 2008 SW3 Corrective Measures Implementation (CMI) Work Plan and 2009 and 2012 CMI Work Plan Addenda. Since the start of AS system operations on December 19, 2012, through the September 2016 groundwater sampling event, TCE concentrations have decreased to less than the GCTL in all wells within the Active Remediation Zone (ARZ), and VC results remain less than NADC but greater than GCTL. Based on these results, team consensus was reached at the October 2016 KSC Remediation Team (KSCRT) meeting to continue AS system operations and semi-annual performance monitoring of volatile organic compounds in March 2017 at ten monitoring wells at select locations, and in September 2017 at four monitoring wells at select locations to reduce VC concentrations to below GCTL. Additionally, surface water samples will be collected at locations SW0001, SW0002, and SW0003 during both the March and September 2017 events. Team consensus was also reached at the October 2017 KSCRT meeting to continue with operation and maintenance (O&M) of the AS system at SW3.

REPORT↗

Launch Complex 39B, SWMU 009, 2023 Performance Monitoring and Air Sparge Expansion Construction Completion Report, Kennedy Space Center, Florida

The 2023 Performance Monitoring and Construction Completion Report (PM-CCR) presents the findings, observations, and results for Air Sparging (AS) operations and expansion activities, as well as sitewide groundwater monitoring for Launch Complex 39B (LC39B), Solid Waste Management Unit (SWMU) 009, at Kennedy Space Center (KSC), Florida. The reporting period for activities covered under this PM-CCR is from January 1, 2023, to December 31, 2023. At LC39B, AS operations began in 2017 in the area west of the launch pad, in the liquid oxygen (LOX) tank area located northwest of the launch pad, and in an area outside of the perimeter fence to protect nearby Outstanding Florida Waters (OFW). The LC39B AS system was installed with 279 AS wells to depths ranging from 23 to 60 feet below land surface (bls), including the sump, correlating to top of screen depths ranging from 20 to 57 feet bls. In December 2022, a total of 22 AS wells were abandoned to support launch pad crane operations, and in November 2023, the system was expanded with five additional AS wells installed to 13 or 17 feet bls near the LOX tank. The remedial objective of the LC39B AS Interim Measure (IM) is to actively decrease concentrations of contaminants of concern (COCs) in groundwater, specifically trichloroethene (TCE), cis-1,2-Dichloroethene (cDCE), and vinyl chloride (VC), to less than their respective Natural Attenuation Default Concentrations (NADCs), so LC39B can transition into a Long-Term Monitoring (LTM) program. This PM-CCR presents the following information for LC39B: • AS system operations and maintenance (O&M) (Year 7 of operation) from January 2023 to December 2023, to include AS trailer relocation in March 2023 and subsequent replacement and re-start in June 2023. • Construction completion details for AS system expansion, which included installation of five new AS wells and one new monitoring well in November 2023. As part of expansion activities, soil samples were also collected for petroleum analysis; no exceedances were identified, and no further investigation for petroleum is warranted. • Performance monitoring results for groundwater sampling events conducted in May/June 2023 (30 wells) and November 2023 (31 wells) in the AS IM area and in the Low Concentration Plume (LCP) areas located north and east of the launch pad for volatile organic compound (VOC) analysis. • Sampling results for one monitoring well, LOX-IW0012S, which is sampled for aluminum on an annual basis (May/June 2023). This well was resampled in November 2023 for both total and dissolved aluminum. Due to a communication error with the laboratory, the May/June 2023 sample was analyzed for total aluminum only. • Groundwater sampling results for per- and polyfluoroalkyl substances (PFAS) collected from seven monitoring wells during the May/June 2023 event to further investigate the Former Sewage Treatment Plant #6 and Percolation Pond area, west of the launch pad. O&M and performance monitoring results show that the AS system at LC39B is operating as designed and meeting performance criteria. Overall runtime was 45 percent (%) during the reporting period (January to December), but the operational runtime was 78% during the timeframe when the system could run (June to December). The most significant downtime contributor was post-launch crane operations following the Artemis launch on November 16, 2022, which lasted until June 2023. During that timeframe, the AS trailer at LC39B was relocated to another KSC remediation site (Wilson Corners) and was subsequently replaced with the AS trailer from the Paint & Oil Locker (POL) remediation site at KSC to resume AS system operations. Performance monitoring results in the AS IM and LCP areas continue to show reduction in COC concentrations over time when compared to baseline levels. In 2023, only one monitoring well (MW0048) detected a COC exceeding its NADC (VC at 740 micrograms per liter [µg/L]), which marks the baseline result for this new well installed during system expansion. Across the rest of the site, VC concentrations have declined or remained stable during the 2023 sampling events. Excluding MW0048, the highest VC result in 2023 was during the May/June sampling event with a concentration of 63 µg/L at MW0032, which is located near MW0048 and the AS expansion area by the LOX tank. TCE was detected in select monitoring wells in the IM area in 2023, but only two locations exceeded the State of Florida Groundwater Cleanup Target Level (GCTL): MW0032 (21 µg/L in May/June 2023 and 9.1 µg/L in November 2023) and MW0036 (5.0 µg/L in November 2023). MW0036 is also located near the LOX tank, on the north side, where the AS system is still operational (Zone Z4). cDCE and trans-1,2-dichloroethene concentrations were less than laboratory method detection limits or their respective GCTLs in all wells sampled in 2023. Near the OFW located northwest of the launch complex, all COC concentrations were less than laboratory method detection limits from monitoring wells (MW0039, MW0040, and LOXTA0002S) sampled in 2023. Aluminum results from LOX-IW0012S, which has been sampled routinely since 2006, detected a total aluminum concentration of 3,900 µg/L during the May/June 2023 sampling event. Results from the November 2023 event detected 5,700 µg/L for total aluminum and 5,500 µg/L for dissolved aluminum. These concentrations slightly decreased from the previous year but remain relatively consistent with historical detections. Aluminum will continue to be sampled on an annual basis at this well as results still exceed the GCTL of 200 µg/L and the Upper Limit of the KSC Background Concentration of 280 µg/L. PFAS results detected nine different PFAS compounds (out of 32 analyzed) from seven wells sampled. Two PFAS compounds, perfluorooctanesulfonic acid (PFOS) and perfluorooctanoic acid (PFOA), currently have FDEP Provisional GCTLs of 70 nanograms per liter (ng/L). All seven samples collected resulted in concentrations less than the FDEP Provisional GCTLs for both PFAS compounds; no exceedances were observed. PFOS and PFOA also have assigned United States Environmental Protection Agency (USEPA) Maximum Contaminant Levels (MCLs) of 4 nanograms per liter (ng/L). None of the PFOS results exceeded the USEPA MCLs. PFOA was detected in two samples above the USEPA MCL at concentrations of 5.8 ng/L (ECS-IW0009I) and 5.5 ng/L (ECS-IW0009S). Three other PFAS compounds, perfluorohexanesulfonic acid (PFHxS), perfluoro-n-nonanoic acid (PFNA), and hexafluoropropylene oxide dimer acid (GenX), currently have USEPA MCLs of 10 ng/L. PFHxS, PFNA, and GenX were not detected at concentrations greater than their respective USEPA MCLs in any of the seven wells. PFAS compounds without FDEP Provisional GCTLs or USEPA MCLs were screened against USEPA RSLs. No other detections exceeded their respective USEPA RSLs. Additional PFAS sampling will be conducted as part of a future PFAS Site Assessment. Based on O&M activities and performance monitoring, the following is recommended for LC39B: • Continue with Year 8 AS system operation within Zone Z4, which includes the AS expansion area. Zone Z3, which has been off since 2018, should remain off as no rebound has been observed. Zones Z1 and Z2, which were turned off at the end of 2022, will remain shut down as monitoring well results have consistently been below GCTLs or have low-level detections with stable or decreasing trends (Meeting Minute 2402-M10, Decision 2402-D30). • Continue with performance monitoring in 2024 with the same monitoring well network as 2023, except with the addition of MW0048 in both semi-annual events. Baseline concentrations for this well were collected during the November 2023 performance monitoring event. Semi-annual sampling should be planned for the May 2024 and November 2024 timeframes (Meeting Minute 2402-M10, Decision 2402-D31). • Continue sampling monitoring well, LOX-IW0012S, for aluminum (total and dissolved) on an annual basis in May 2024. It is also recommended to re-develop this well prior to the next sampling event (Meeting Minute 2402-M10, Decision 2402-D32). The above recommendations for LC39B were presented at the February 2024 KSCRT Meeting, with Team consensus reached on the path forward. The contents of this PM-CCR were also presented at this meeting.

Deborah M Wilson↗

Self-timed router with virtual channel control

Systems, apparatuses, and methods for implementing an asynchronous router with virtual channel (VC) control. The asynchronous router may support multiple VCs for connections to other routers. The asynchronous router may include an interface unit on each switch boundary, with each interface unit including a data merge unit. The data merge unit may include a full detector unit for each VC, with the full detector unit counting the number of flits sent out on a respective VC and counting the number of credits released by the successor router. Whenever the successor router has no credits available, the full detector unit will assert the full signal to prevent any input requests from requesting to transmit over that particular VC. When the full signal is asserted, a timer unit may be activated to repeatedly check if any credits have been released in the successor router.

Jiang, Weiwei↗

Packet router with virtual channel hop buffer control

An integrated circuit includes a network on chip (NOC) that includes a plurality of processing elements and a plurality of NOC nodes, interconnected to the plurality of processing elements. The integrated circuit includes logic that is configured to: increment by one, a virtual channel identifier to produce an incremented destination VC identifier, the virtual channel (VC) identifier associated with at least portion of a packet stored in at least one virtual channel buffer; determine that a destination virtual channel buffer corresponding to the incremented destination VC identifier in a destination NOC node in the NOC is available to store the portion of the packet; and in response to the determination, send the portion of the packet and the incremented destination VC identifier to the destination NOC node.

97 MATHEMATICS AND COMPUTING↗

Nuclear Factor-κB is Activated in Filter-Implanted Vena Cava

Background: Implantation of a retrievable vena cava filter (VCF) is an effective method for preventing pulmonary embolism. Retrieval of filters, however, may be difficult due to intimal hyperplasia and inflammation in the cava wall. The transcription factor nuclear factor-kappaB (NF-κB) plays an important role in regulation of numerous genes participating in the inflammatory and proliferative responses of cells. The present study was to determine whether VCF implantation resulted in activation of NF-κB in the venous neointima. Methods: Filters were placed in vena cava (VC) in four swine for 30 days and then removed. Intimal specimens adhering to the filter struts were analyzed with reference to normal VC tissues. Immunohistochemical analyses were used to assess the NF-κB subunits p65 and p50 and the phosphorylated inhibitor of κB-α (phosphor-IκB-α) in the tissues. NF-κB DNA-binding activity was measured with enzyme-linked immunosorbent assay. Results: As compared to normal VC tissues, the intimal tissues contained higher percentages of cell nucleus-located p65 and p50, and NF-κB DNA-binding activity. Elevated immunoreactivities of p65, p50 and phosphor-IκB-α were also present in the intima. Conclusion: The present study demonstrates for the first time that VCF implantation caused NF-κB activation in neointima. We further demonstrate the activation is at least partly due to phosphorylation of IκB-α. Our data suggest that NF-κB activation would significantly contribute to development of intimal hyperplasia and inflammation in filter-inserted vena cava walls. NF-κB might be a therapeutic target for inhibiting filter-induced neointima and improving filter retrieval.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impacts of low-temperature thermal treatment on microbial detoxification of tetrachloroethene under continuous flow conditions

Coupling in situ thermal treatment (ISTT) with microbial reductive dechlorination (MRD) has the potential to enhance contaminant degradation and reduce cleanup costs compared to conventional standalone remediation technologies. Impacts of low-temperature ISTT on Dehalococcoides mccartyi (Dhc), a relevant species in the anaerobic degradation of cis-1,2-dichloroethene (cis-DCE) and vinyl chloride (VC) to nontoxic ethene, were assessed in sand-packed columns under dynamic flow conditions. Dissolved tetrachloroethene (PCE; 258 ± 46 μM) was introduced to identical columns bioaugmented with the PCE-to-ethene dechlorinating consortium KB-1®. Initial column temperatures represented a typical aquifer (15 °C) or a site undergoing low-temperature ISTT (35 °C), and were subsequently increased to 35 and 74 °C, respectively, to assess temperature impacts on reductive dechlorination activity. In the 15 °C column, PCE was transformed primarily to cis-DCE (159 ± 2 μM), which was further degraded to VC (164 ± 3 μM) and ethene (30 ± 0 μM) within 17 pore volumes (PVs) after the temperature was increased to 35 °C. Regardless of the initial column temperature, ethene constituted >50 mol% of effluent degradation products in both columns after 73–74 PVs at 35 °C, indicating that MRD performance was greatly improved under low-temperature ISTT conditions. Increasing the temperature of the column initially at 35 °C resulted in continued VC and ethene production until a temperature of approximately 43 °C was reached, at which point Dhc activity substantially decreased. The abundance of the vcrA reductive dehalogenase gene exceeded that of the bvcA gene by 1–2.5 orders of magnitude at 15 °C, but this relationship inversed at temperatures >35 °C, suggesting Dhc strain-specific responses to temperature. These findings demonstrate improved MRD performance with low-temperature thermal treatment and emphasize potential synergistic effects at sites undergoing ISTT.

42 ENGINEERING↗