Search NASA⌕ Search

SEARCH · Search NASA

Results for “VIBRATION PROTECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Subminiature transducer measures unsteady pressures

Transducer has thin piezoelectric sensing element of 0.051-cm-thick lead zirconate titanate crystal which is cut as a conical frustum. Sensing crystal and titanium wire are protected from mechanical shock and vibration. Transducer is insensitive to mechanical vibrations of instrument plug on which it is mounted.

Raman, K. R.↗

Circuit board package with wedge shaped covers

A circuit board packaging and mounting technique that protects the wiring board from vibrations and contamination is described. The technique also augments chassis rigidity and damping and conducts component generated heat to the chassis.

Pesek, C. T.↗

Peak-acceleration limiter

Statistical limiter, which protects test specimens during random vibration testing, differentiates between peak acceleration levels that are normal components of vibration signal and those that exhibit damaging characteristics. Device aborts test only when statistical properties of vibration signal change significantly or when catastrophic transient occurs.

Woodbury, R. C.↗

Holding Cargo in Place With Foam

Foam fills entire container to protect cargo from shock and vibration. Originally developed for stowing space debris and spent satellites in Space Shuttle for return to Earth, encapsulation concept suitable for preparing shipments carried by truck, boat, or airplane. Equipment automatically injects polyurethane foam into its interior to hold cargo securely in place. Container of rectangular or other cross section built to match shape of vehicle used.

Fisher, T. T.↗

Soft Sleeve Between Glove Box And Instrument

Sleeve protects instrument from low frequency vibrations and helps maintain clean atmosphere for semiconductor analysis. Flexible sleeve joins glove box to specimen-introduction port of instrument chamber. Coupling made of brown nylon with inner layer of white rubber, attached to both areas with specially designed clamps. Thickness of sleeve material 0.01 in.

Lombardi, Frank↗

Suppression of Transient Events by Levitation (STABLE): Results From the USML-2 Mission

Microgravity science payloads can be extremely sensitive to vibrations from machinery, acoustics, ventilation, and crew activity. Suppression of Transient Acceleration by Levitation (STABLE) is an active vibration isolation system designed to protect payloads from these disturbances. This paper gives an account of results from the flight demonstration of the STABLE microgravity isolation system, which was developed and successfully flight tested in orbit during USML-2, with the participation of Astronaut Fred Leslie. Following a very brief description of the operational principles, the hardware and software design, and performance criteria, results of the analysis of measured flight data are presented to provide an evaluation of system performance parameters, including acceleration attenuation, assessment of sway space, system power consumption, and other factors critical to the performance of an isolation system. Lessons learned and potential design improvements and evolutions are discussed. Data reduction by Robert Boucher of McDonnell Douglas Aerospace (MDA) was substantially assisted by Kenneth Hrovat of Tal-Cut, Inc., under support from National Aeronautics and Space Administration/Lewis Research Center (LeRC), Cleveland, OH.

Nurre, Gerald S.↗

Analytic Methods for Predicting Significant Multi-Quanta Effects in Collisional Molecular Energy Transfer

Collision-induced transitions can significantly affect molecular vibrational-rotational populations and energy transfer in atmospheres and gaseous systems. This, in turn. can strongly influence convective heat transfer through dissociation and recombination of diatomics. and radiative heat transfer due to strong vibrational coupling. It is necessary to know state-to-state rates to predict engine performance and aerothermodynamic behavior of hypersonic flows, to analyze diagnostic radiative data obtained from experimental test facilities, and to design heat shields and other thermal protective systems. Furthermore, transfer rates between vibrational and translational modes can strongly influence energy flow in various 'disturbed' environments, particularly where the vibrational and translational temperatures are not equilibrated.

Bieniek, Ronald J.↗

Analytical and experimental evaluations of Space Shuttle TPS tile vibration response

Analytical studies and laboratory experiments have been performed to evaluate the vibration response of the Space Shuttle Thermal Protection System (TPS) tiles due to the intense rocket generated acoustic noise during lift-off. The TPS tiles are mounted over the exterior of the Space Shuttle Orbiter structure through Strain Isolation Pads (SIP) which protect the tiles from thermal induced shear loads at their interface. The analytical predictions indicate that the response of a typical tile is governed by the structural vibration inputs through the SIP under the tile at frequencies below 250 Hz, and by the direct acoustic excitation over the exterior surface of the tile at frequencies above 250 Hz. An evaluation of the laboratory test data for this same tile, in which conditioned (partial) coherent output spectral analysis procedures were used, leads to exactly the same conclusion. The results demonstrate the power of conditioned spectral analysis procedures in identifying vibration response mechanisms when two or more of the inputs are highly correlated.

Piersol, A. G.↗

Vibration-Resistant Support for Halide Lamps

Lamp envelope protected against breakage. Old and new mounts for halide arc lamp sealed in housing with parabolic refector and quartz window. New version supports lamp with compliant garters instead of rigid brazed joint at top and dimensionally unstable finger stock at bottom.

Kiss, J.↗

Direct Observation of Transient Structural Dynamics of Atomically Thin Halide Perovskite Nanowires

Halide perovskite is a unique dynamical system, whose structural and chemical processes happening across different timescales have significant impact on its physical properties and device-level performance. However, due to its intrinsic instability, real-time investigation of the structure dynamics of halide perovskite is challenging, which hinders the systematic understanding of the chemical processes in the synthesis, phase transition, and degradation of halide perovskite. Here, we show that atomically thin carbon materials can stabilize ultrathin halide perovskite nanostructures against otherwise detrimental conditions. Moreover, the protective carbon shells enable atomic-level visualization of the vibrational, rotational, and translational movement of halide perovskite unit cells. Albeit atomically thin, protected halide perovskite nanostructures can maintain their structural integrity up to an electron dose rate of 10,000 e – /Å 2 ·s while exhibiting unusual dynamical behaviors pertaining to the lattice anharmonicity and nanoscale confinement. Here, our work demonstrates an effective method to protect beam-sensitive materials during in situ observation, unlocking new solutions to study new modes of structure dynamics of nanomaterials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Failure of brittle micro-spherical shells embedded in elastomer matrix under indentation

Silicone elastomer filled with glass micro balloons (GMB) is an elastomeric syntactic foam used in electronics and component packaging for encapsulation, potting, stress-relief layer, and electrical insulation purposes. Under mechanical loading, the reinforcing phase, namely the GMBs embedded in the elastomer matrix, may break or delaminate, leading to internal damage and macroscale stiffness degradation, which can alter the material's protective capacity against mechanical shock and vibration. The degree of damage is controlled by the loading history, delamination, and failure behavior of the GMBs. In this work, we investigate the GMB failure behavior in this work wherein we present an indentation experiment to measure the force required to fail individual GMBs that are either embedded in the elastomer matrix or adhered to the surface of an elastomer layer. The indentation apparatus is augmented with an inverted optical microscope to enable in situ imaging of the GMB. Failure modes for the embedded or non-embedded GMBs are discussed based on the morphology of the broken GMBs and the measured failure forces. We also measure the adhesion energy between the glass balloon and the elastomer, based on which the possibility of delamination between the GMB and the surrounding elastomer matrix during the failure process is evaluated. Our results can facilitate the development of a failure criterion of GMBs which is necessary for establishing a physics-based constitutive model to describe the macroscopic damage mechanics of elastomeric syntactic foams.

42 ENGINEERING↗

Experimental Realization of Decoherence-Free Subspace in Neutron Interferometry

A decoherence-free subspace (DFS) is an important class of quantum-error-correcting (QEC) codes that have been proposed for fault-tolerant quantum computation. The applications of QEC techniques, however, are not limited to quantum-information processing (QIP). Here we demonstrate how QEC codes may be used to improve experimental designs of quantum devices to achieve noise suppression. In particular, neutron interferometry is used as a test bed to show the potential for adding quantum error correction to quantum measurements. We built a five-blade neutron interferometer that incorporates both a standard Mach-Zender configuration and a configuration based on a DFS. Experiments verify that the DFS interferometer is protected against low-frequency mechanical vibrations. We anticipate these improvements will increase the range of applications for matter-wave interferometry.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improvements to LCLS-II Cryomodule Transportation

The Linear Coherent Light Source (LCLS-II) is currently being constructed at the SLAC National Laboratory. A total of 35 cryomodules will be fabricated at Jefferson Lab (JLab) in Virginia and Fermi National Laboratory (FNAL) in Illinois and transported via road to SLAC. A shipping frame with an inner bed isolated by springs was designed to protect the CMs from shocks and vibrations during shipments. Successful road testing of the JLab prototype paved the way for production CM shipments. The initial production shipments lead to several catastrophic failures in beamline vacuum in the cryomodules. The failures were determined to be due to fatigue in Fundamental Power Coupler (FPC) bellows due to excessive motion during shipment. A series of instrumented CM shipping tests and component tests were undertaken to develop a solution. A modified spring layout was tested and implemented, which reduced shocks on the CMs. FPC coupler bellows restraints were tested on a shaker table and on a CM during shipping; they were able to reduce bellows motion by a factor of three. The updated shipping system is currently in use and has successfully delivered six cryomodules to SLAC from JLab and FNAL.

43 PARTICLE ACCELERATORS↗

NA22 Ge-140 FY17 end of year report [Ge-140 Spectrometer]

The goal of this three-year project is to build a hand-held, high-resolution, germanium-based, gamma-ray spectrometer of 140% relative efficiency that is mechanically cooled. The final instrument should be light enough to be easily carried by one person, and the power consumption should be low enough for battery operation. We completed the Ge-140 design and demonstrated a cryostat with excellent thermal isolation. We performed tests to compare and verify the performance of viable cryocooler candidates, and developed a suspension system that will protect the crystal against shock and vibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rugged microelectronic module package supports circuitry on heat sink

Rugged module package for thin film hybrid microcircuits incorporated a rigid, thermally conductive support structure, which serves as a heat sink, and a lead wire block in which T-shaped electrical connectors are potted. It protects the circuitry from shock and vibration loads, dissipates internal heat, and simplifies electrical connections between adjacent modules.

Johnson, A. L.↗

Development and utilization of a laser velocimeter system for a large transonic wind tunnel

The need for measurements of the velocity flow field about spinner propeller nacelle configurations at Mach numbers to 0.8 was met by a specially developed laser velocimeter system. This system, which uses an argon ion laser and 4 beam 2 color optics, was required to operate in the hostile environment associated with the operation of a large transonic wind tunnel. To overcome the conditions present in locating the sensitive optics in close proximity to the wind tunnel, an isolation system was developed. The system protects the velocimeter from the high vibrations, elevated temperatures, destructive acoustic pressures and low atmospheric pressures attendant with the operation of the wind tunnel. The system was utilized to map the flow field in front of, behind and in between the rotating blades of an advanced swept blade propeller model at a Mach number of 0.8. The data collected by the system will be used to correlate and verify computer analyses of propeller nacelle flow fields and propeller performance.

Freedman, R. J.↗

Vibration Isolation Technology (VIT) ATD Project

A fundamental advantage for performing material processing and fluid physics experiments in an orbital environment is the reduction in gravity driven phenomena. However, experience with manned spacecraft such as the Space Transportation System (STS) has demonstrated a dynamic acceleration environment far from being characterized as a 'microgravity' platform. Vibrations and transient disturbances from crew motions, thruster firings, rotating machinery etc. can have detrimental effects on many proposed microgravity science experiments. These same disturbances are also to be expected on the future space station. The Microgravity Science and Applications Division (MSAD) of the Office of Life and Microgravity Sciences and Applications (OLMSA), NASA Headquarters recognized the need for addressing this fundamental issue. As a result an Advanced Technology Development (ATD) project was initiated in the area of Vibration Isolation Technology (VIT) to develop methodologies for meeting future microgravity science needs. The objective of the Vibration Isolation Technology ATD project was to provide technology for the isolation of microgravity science experiments by developing methods to maintain a predictable, well defined, well characterized, and reproducible low-gravity environment, consistent with the needs of the microgravity science community. Included implicitly in this objective was the goal of advising the science community and hardware developers of the fundamental need to address the importance of maintaining, and how to maintain, a microgravity environment. This document will summarize the accomplishments of the VIT ATD which is now completed. There were three specific thrusts involved in the ATD effort. An analytical effort was performed at the Marshall Space Flight Center to define the sensitivity of selected experiments to residual and dynamic accelerations. This effort was redirected about half way through the ATD focusing specifically on the sensitivity of protein crystals to a realistic orbital environment. The other two thrusts of the ATD were performed at the Lewis Research Center. The first was to develop technology in the area of reactionless mechanisms and robotics to support the eventual development of robotics for servicing microgravity science experiments. This activity was completed in 1990. The second was to develop vibration isolation and damping technology providing protection for sensitive science experiments. In conjunction with the this activity, two workshops were held. The results of these were summarized and are included in this report.

Lubomski, Joseph F.↗

Improvements for LCLS-II Cryomodule Transportation

The Linear Coherent Light Source (LCLS-II) is currently being constructed at the SLAC National Laboratory. A total of 35 cryomodules will be fabricated at Jefferson Lab (JLab) in Virginia and Fermi National Laboratory (FNAL) in Illinois and transported via road to SLAC. A shipping frame with an inner bed isolated by springs was designed to protect the CMs from shocks and vibrations during shipments. Successful road testing of the JLab prototype paved the way for production CM shipments. The initial production shipments lead to several catastrophic failures in beamline vacuum in the cryomodules. The failures were determined to be due to fatigue in Fundamental Power Coupler (FPC) bellows due to excessive motion during shipment. A series of instrumented CM shipping tests and component tests were undertaken to develop a solution. A modified spring layout was tested and implemented, which reduced shocks on the CMs. FPC coupler bellows restraints were tested on a shaker table and on a CM during shipping; they were able to reduce bellows motion by a factor of three. The updated shipping system is currently in use and has successfully delivered six cryomodules to SLAC from JLab and FNAL.

Huque, N. A.↗