Search NASA⌕ Search

SEARCH · Search NASA

Results for “Vacuum apparatus”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Irradiated gases transferred without contamination or dilution

Vacuum chamber apparatus opens sealed canisters of irradiated gases and transfers the contents without contaminating the surrounding area, and without diluting or polluting the contained gases. The apparatus consists of the chamber, a valved piping manifold, and a special drill and sealed drilling access.

Bonn, J. L.↗

Coating a Sphere With Evaporated Metal

In vacuum coating apparatus, metal evaporated onto sphere from small source located some distance away. Sphere held in path of metal vapor while rotated about axis that rocks back and forth. One tilting motion particularly easy to produce is sinusoidal rocking with frequency much lower than rotational frequency. Apparatus developed for coating single-crystal sapphire spheres with niobium.

Strayer, D. M.↗

Apparatus For Metal/Inert-Gas Welding In Vacuum

Metal/inert-gas welding-torch assembly operates in vacuum. Plasma generated in interior chamber and focused onto workpiece in vacuum. Pinch rollers feed wire to weld puddle. Controlled flow of plasma reduces dispersal in vacuum, preventing extinction.

Stocks, C. O.↗

Carbon in The Universe: PAHs and Clusters

Following the initial demonstration of this new technique (Science 265 1686 (1994)) and its application to a series of neutral PAHs which have been proposed as condidates for the UIRs (Nature 380, 227 (1996)), we have concentrated on two major aspects of this project. 1. Developing a detailed model for infrared emission spectra of a collection of highly excited PAH molecules, in which experimental bandshapes and temperature-dependent redshifts are used in conjunction with ab initio vibrational frequencies and intensities to simulate the UIR bands. This shows that a collection of nine different cations (as large as ovalene) reproduce the UIR features better than do a collection of the corresponding neutrals, but a detailed match with the UIRs is not obtained. 2. Construction of SPIRES apparatus for the study of PAH ion emission spectra. The design of this experiment is shown and described. Unfortunately a disasterous accident occurred just as we were preparing to start the testing of the ion apparatus. A vacuum implosion occurred, destroying the liquid He cooled monochromator. It has taken us nearly one full year to reconstruct this, and we arc only now in the final testing of the new system. We expect to try the ion experiments by the end of summer.

Saykally, Richard J.↗

Cryogenic Transfer Line Chilldown

The transient behavior of a small scale cryogenic transfer line was investigated during chilldown to cryogenic temperatures. The vacuum-jacketed apparatus consisted of a vertical tube followed by a near horizontal tube. The apparatus was equipped with view ports in the near horizontal section to allow visual observation of the flow patterns. Wall temperatures were measured at various locations along the length of the transfer line. Each test was conducted at a constant liquid volumetric flowrate at the transfer line inlet until saturation temperatures were obtained throughout the system.

VanDresar, Neil T.↗

An Improved Technique for the Preparation of Mounted or Unmounted Carbon/Epoxy Specimens

As carbon/epoxy materials became more prevalent in the aerospace industry, microstructural analysis demanded specimen preparation techniques that led to better polished surfaces, achievable in a shorter time, and using fewer steps. The desire to use image analysis for material characterization also helped drive the goal for defect free surfaces. At NASA-Langley (LaRC), carbon/epoxy specimens had been historically prepared in 1 inch diameter Bakelite mounts. Carbon/epoxy specimens that were 1/8 to 1/4 inch thick were not affected by the heat and pressure required for mounting in Bakelite, however thinner specimens were crushed during mounting. A two-part room temperature curing epoxy was chosen as an alternative but sometimes voids developed between the specimen and the mounting material. This was prevented by either heating the epoxy to 140 degrees F to lower the viscosity of the epoxy or by using a vacuum impregnation apparatus. Both techniques helped facilitate flow and allowed the epoxy to penetrate crevices.

Edahl, Robert A., Jr.↗

Development of an 400 L Integrated Refrigeration and Storage Cryostat for LNG/LCH4 Research

Research engineers from the Cryogenics Test Laboratory at NASA Kennedy Space Center in Florida have developed a 400 liter Integrated Refrigeration and Storage (IRAS) cryostat to explore advanced techniques for storage, conditioning, and transfer of liquefied natural gas and/or pure methane. A vertical-cylindrical configuration, the vacuum-jacketed apparatus houses a G-M cryocooler to control the state of the fluid, and sample tubes with corresponding temperature sensors fixed at various elevations to allow for sampling of the liquid. Two additional ports were also included for future instrumentation and/or mechanical feed-throughs. A primary goal of this test apparatus will be to study the effect of IRAS on the behavior of LNG during storage; most notably weathering and stratification of the bulk liquid over time. Additionally, in-situ liquefaction of natural gas can be performed, along with zero boil-off control, liquid densification, and slush production.

Swanger, Adam M.↗

Torsion pendulum measurements on viscoelastic materials during vacuum exposure

A torsional pendulum apparatus designed for testing in situ in vacuum, the dynamic mechanical properties of materials is described. The application of this apparatus to an experimental program to measure the effects of vacuum on the mechanical properties of two ablator materials (a foamed material and a filled elastomer) and a solid rocket propellant (a filled elastomer) is presented. Results from the program are discussed as to the effects of vacuum on the mechanical properties of these three materials. In addition, time-temperature-superposition, as a technique for accelerating vacuum induced changes in mechanical properties, is discussed with reference to the three materials tested in the subject program.

Ward, T. C.↗

Vacuum arc plasma thrusters with inductive energy storage driver

An apparatus for producing a vacuum arc plasma source device using a low mass, compact inductive energy storage circuit powered by a low voltage DC supply acts as a vacuum arc plasma thruster. An inductor is charged through a switch, subsequently the switch is opened and a voltage spike of Ldi/dt is produced initiating plasma across a resistive path separating anode and cathode. The plasma is subsequently maintained by energy stored in the inductor. Plasma is produced from cathode material, which allows for any electrically conductive material to be used. A planar structure, a tubular structure, and a coaxial structure allow for consumption of cathode material feed and thereby long lifetime of the thruster for long durations of time.

Schein, Jochen↗

Multipurpose Thermal Insulation Test Apparatus

A multi-purpose thermal insulation test apparatus is used for testing insulation materials, or other components. The test apparatus is a fluid boil-off calorimeter system for calibrated measurement of the apparent thermal conductivity (k-value) of a specimen material at a fixed vacuum level. The apparatus includes an inner vessel for receiving a fluid with a normal boiling point below ambient temperature, such as liquid nitrogen, enclosed within a vacuum chamber. A cold mass assembly, including the inner vessel and thermal guards, is suspended from the top of the vacuum chamber. Handling tools attach to the cold mass assembly for convenient manipulation of the assembly and for the installation or wrapping of insulation test materials. Liquid nitrogen is typically supplied to the inner vessel using a fill tube with funnel. A single port through the top of the vacuum chamber facilitates both filling and venting. Aerogel composite stacks with reflective films are fastened to the top and the bottom of the inner vessel as thermal guards. The comparative k-value of the insulation material is determined by measuring the boil-off flow rate of gas, the temperature differential across the insulation thickness, and the dimensions (length and diameters) of the test specimen.

Fesmire, James E.↗

Vacuum effects on spacecraft materials

Apparatus and techniques for investigating spacecraft materials mechanical and thermal properties, using vacuum effect to simulate space environment

Comparin, R. A.↗