Search NASA⌕ Search

SEARCH · Search NASA

Results for “Vacuum apparatus”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

51 records · Page 3

Hydrogen, lithium, and lithium hydride production

A hydrogen, lithium, and lithium hydride processing apparatus includes a hot zone to heat solid-phase lithium hydride to form liquid-phase lithium hydride; a vacuum source to extract hydrogen and gaseous-phase lithium metal from the liquid-phase lithium hydride; a cold zone to condense the gaseous-phase lithium metal as purified solid-phase lithium metal; and a heater to melt the purified solid-phase lithium metal in the cold zone and form refined liquid-phase lithium metal in the hot zone.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vacuum-ultraviolet light source for enhanced production of metastable krypton and xenon beams

Here, we demonstrate excitation of metastable krypton and xenon beams using a vacuum ultraviolet lamp and directly compare the performance of this method to metastable excitation based on a radio-frequency-driven plasma discharge. In our apparatus, lamp-based metastable excitation outperforms the plasma discharge across a wide range of beam flux values relevant for atom trap trace analysis (ATTA). Moreover, we do not observe significant degradation in lamp performance after over 160 h of operation. We find that lamp-based excitation is particularly advantageous at the smallest and largest beam fluxes tested, demonstrating the utility of this approach both for improving krypton ATTA and for enabling the detection of radioactive xenon isotopes using ATTA. Finally, we demonstrate an additional enhancement to lamp-based metastable excitation efficiency and stability by applying an external magnetic field.

Metastable noble gases↗

Ultraviolet (UV) light emitting device (LED) driven photocathode

An apparatus includes an electromechanical x-ray generator (MEXRAY) configured to charged capacitors using a small, high-voltage direct current. The apparatus also includes an ultraviolet (UV) light emitting diode (LED) driven photocathode device configured to control/modulate an electron dose rate of the MEXRAY or other vacuum DC, source.

Watson, Scott Avery↗

Hydrogen Diffusion Coefficient Measures on Thin Film Uranium Oxide

Thin films of uranium oxides, putatively UO 2 and U 3 O 8 , were deposited on palladium/silver (75/25) foil discs (10 μm thick, 10 mm diameter). Methodology for sealing these foils, applying a hydrogen pressure (~ 1 atm) to the oxide side, and measuring the pressure on the permeate side (opposite side of foil) is reported. The experimental apparatus is held at 100 °C to speed diffusion, aided by the pressure differential across the foil (~1 atm (750 torr) on oxide side, initially low vacuum on permeate side, ~1x 10 -4 torr). Early results indicate an effective diffusion coefficient of roughly 7.66 x 10 -17 +/- 2.22 x 10 -17 cm 2 /sec for UO 2 . These values are in line with expectations and prior measures relative to large lag times for system baseline (substrate only). Evaluation of the technique for U 3 O 8 thin films suggests further development will be needed to extend the technique to more oxidized films (U 3 O 8 , UO 3 ). Characterization of the foils (thickness and speciation) post diffusion experiments will be carried out by SIGMA (Eric Tegtmeier and Andy Richards) in FY24 which will sharpen the uncertainty quantification for UO 2 diffusion coefficients, aiding the nucleation model for DRACO.

36 MATERIALS SCIENCE↗

Hydrogen transport in yttrium hydride under asymmetric heat

Metal hydrides are a promising moderator material for high temperature fission reactors. Yttrium hydride can be loaded to a high hydrogen density with relatively high hydrogen stability at temperatures up to 800°C. This makes yttrium hydride a potential moderator material for microreactors as foreseen in the fission surface power program. However, during the operation of such advanced reactors temperature gradients are expected which can change the local hydrogen density in the moderator. Hydrogen diffusion in metals is driven by a concentration gradient (Fick’s law) and thermal diffusion (Soret diffusion). Thermal diffusion is the transport of hydrogen, or other species, due to a temperature gradient. For example, hydrogen might migrate from the hot side of a sample to the cold side of a sample. Measuring Fickian diffusion is achieved through various permeation or absorption experiments, however measuring thermal diffusion is challenging and has rarely been performed. The Hydrogen Experimental Apparatus for Thermal Diffusion (HEATD) experiment is designed to induce thermal diffusion in samples and quench those samples so that the hydrogen distribution can be analyzed using hot vacuum extraction (HVE). One side of the sample was heated to a high temperature e.g., 800°C, while the other side of the sample is at a lower temperature. The sample was held under the applied temperature gradient for a given time until the anticipated hydrogen diffusion has occurred. The actual time depends depend on the sample composition and hydrogen concentration. The results from HVE showed that thermal diffusion took place in the specimen and the Soret coefficient was calculated.

36 MATERIALS SCIENCE↗

First demonstration of a fiber optic bolometer on a tokamak plasma (invited)

A fiber optic bolometer (FOB) was demonstrated observing a fusion plasma for the first time at the DIII-D tokamak. A FOB uses a fiber optics-based interferometric technique that is designed to have a high sensitivity to temperature changes [75 mK/(W/m2) responsivity in high vacuum with 0.38 mK noise level] with a negligible susceptibility to electromagnetic interference (EMI) that can be problematic for resistive bolometers in a tokamak environment. A single-channel test apparatus was installed on DIII-D consisting of a measurement FOB and shielded reference FOB. The single-channel FOB showed a negligible increase in the noise level during typical plasma operations (0.39 mK) compared to the benchtop results (0.38 mK), confirming an insignificant EMI impact to the FOB. Comparisons to DIII-D resistive bolometers showed good agreement with the single-channel FOB, indicating that the FOB is comparable to a resistive bolometer when the impulse calibration is applied. The noise-equivalent power density of the calibrated FOB during a plasma operation was 0.55 W/m2 with an average sampling time of 20 ms. The major potential effect of ionizing radiation on the FOB would be the radiation-induced attenuation, which can be efficiently compensated for by adjusting the probing light power.

Lee, S. (ORCID:0000000170289004)↗

Toward the origins of binding energy shifts and “satellites” formation during plasma-XPS measurements

In-plasma x-ray photoelectron spectroscopy (plasma-XPS) emerges as a powerful platform for real-time, in situ chemical analysis under conditions relevant to semiconductor processing and other plasma-enabled technologies. This study investigates the origins of binding energy (BE) shifts and the formation of “satellite” peaks observed during plasma-XPS measurements across conductive, dielectric, and gas-phase systems. Using a standard laboratory-based ambient pressure XPS apparatus coupled with an alternating current (AC)-driven capacitively coupled plasma source, we demonstrate that metastable surface species, such as transient Au oxides, can be detected during plasma exposure, revealing chemical states that are hardly accessible using conventional ultrahigh vacuum (UHV) XPS. In dielectric samples (e.g., undoped diamond, sapphire), we observe pressure- and plasma-type-dependent BE shifts of more than 50 eV, attributed to x-ray-induced and plasma-mediated surface charging. These shifts are mitigated at higher pressures/plasmas or in electronegative plasmas (e.g., O 2 ), the latter due to enhanced charge compensation mechanisms involving slow negative ions. For gas-phase species, AC-plasma excitation leads to spectral broadening and the emergence of “satellite” peaks with energy separations of a few electron volts, linked to oscillating local plasma potentials in the probing volume. Furthermore, these findings highlight the complex and important interplay between plasma parameters, surface charging, and local electric fields in shaping XPS spectra. Overall, plasma-XPS emerges as a critical metrological tool for probing transient surface chemistry, with implications for semiconductor processing, material synthesis, and plasma diagnostics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High gas-pressure apparatus for nonlinear X-ray propagation and reshaping via stimulated X-ray Raman scattering

Abstract We describe an experimental setup for non-linear interaction and propagation of ultrashort and intense x-ray free-electron laser (XFEL) pulses in a dense gas. It allows one to provide high, but adjustable, target-gas pressures of up to 6 bar within a vacuum environment of 3∙10 − 3 mbar or better. The setup enables investigation of intense x-ray propagation in an optically thick medium with minimal absorption loss of the unfocused beam outside of the target. As an application, we demonstrate the amplification of spectrally-resolved stimulated x-ray Raman scattering (SXRS) in dense neon gas, where the most intense inner part of the beam is almost completely absorbed. As a result, in the inner part of the beam, the SXRS signal exceeds the residual XFEL pulse by a factor of around two. In principle, this reshaping effect allows for a spatial separation of the two spectral components, i.e., the driving pulse and the SXRS signal.

Magunia, Alexander↗

The Orbitron: A crossed-field device for co-confinement of high energy ions and electrons

To explore the confinement of high-energy ions above the space charge limit, we have developed a hybrid magnetic and electrostatic confinement device called an Orbitron. The Orbitron is a crossed-field device combining aspects of magnetic mirrors, magnetrons, and orbital ion traps. Ions are confined in orbits around a high-voltage cathode with co-rotating electrons confined by a relatively weak magnetic field. Experimental and computational investigations focus on reaching ion densities above the space charge limit through the co-confinement of electrons. The experimental apparatus and suite of diagnostics are being developed to measure the critical parameters, such as plasma density, particle energy, and fusion rate for high-energy, non-thermal plasma conditions in the Orbitron. Initial results from experimental and computational efforts have revealed the need for cathode voltages on the order of 100–300 kV, leading to the development of a custom high voltage, ultra-high vacuum bushing rated for 300 kV.

Materials Science↗

Versatile semi-batch apparatus for manometric measurement of gas–solid reaction rates

In this study, we describe the design, construction, operation, and performance of a simple and versatile semi-batch reactor that is especially useful for measurement of gas/solid reaction rates at pressures in the range of 1 mTorr to 1500 Torr. The reactor operates by repeatedly imposing small AC modulations of reactant gas pressure on top of a much larger DC pressure background. Based on the rate of pressure relaxation following each AC pulse, the reaction rate is determined. Our design is characterized by modular construction from off-the-shelf, ultra-high-vacuum-compatible components, which facilitate easy retrofitting and adaptation to a range of experimental conditions. Automated experiment control and data acquisition is accomplished via a custom National Instruments © LabView virtual instrument. Data analysis is automated using a custom series of Mathworks © Matlab scripts. We demonstrate reactor performance through measurements of hydrogenation kinetics for a composite H 2 getter material consisting of 1,4-bis(phenylethynyl)benzene mixed with a palladium/carbon catalyst.

47 OTHER INSTRUMENTATION↗

Microfluidic film evaporation with femtosecond laser-patterned surface

Systems, apparatuses, and methods for microfluidic fluid evaporation using femtosecond laser-patterned surfaces are disclosed. A microfluidic device may comprise a femtosecond laser-patterned substrate having at least one input path and at least one output path. The femtosecond laser-patterned substrate may comprise both superhydrophobic and superhydrophilic sections. Fluid deposited at an input path may be wicked to an output path due to the surface pattern. A heating device may be provided to heat the fluid to evaporate volatiles therefrom. Vacuums and gas streams may be used to aid in volatile removal. Gas streams may add gas to the microfluidic device to react with the fluid.

Pearson, Connor Daniel↗

Absolute calibration of the Lyman-α measurement apparatus at DIII-D

The LLAMA (Lyman-Alpha Measurement Apparatus) diagnostic was recently installed on the DIII-D tokamak [Rosenthal et al., Rev. Sci. Instrum. (submitted) (2020)]. LLAMA is a pinhole camera system with a narrow band Bragg mirror, a bandpass interference filter, and an absolute extreme ultraviolet photodiode detector array, which measures the Ly-α brightness in the toroidal direction on the inboard, high field side (HFS) and outboard, low field side (LFS). This contribution presents a setup and a procedure for an absolute calibration near the Ly-α line at 121.6 nm. The LLAMA in-vacuum components are designed as a compact, transferable setup that can be mounted in an ex situ vacuum enclosure that is equipped with an absolutely calibrated Ly-α source. The spectral purity and stability of the Ly-α source are characterized using a vacuum ultraviolet spectrometer, while the Ly-α source brightness is measured by a NIST-calibrated photodiode. The non-uniform nature of the Ly-α source emission was overcome by performing a calibration procedure that scans the Ly-α source position and employs a numerical optimization to determine the emission pattern. Nominal and measured calibration factors are determined and compared, showing agreement within their uncertainties. A first conversion of the measured signal obtained from DIII-D indicates that the Ly-α brightness on the HFS and LFS is on the order of 1020 Ph sr-1 m-2 s-1. The established calibration setup and procedure will be regularly used to re-calibrate the LLAMA during DIII-D vents to monitor possible degradation of optical components and detectors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reactions of Propyl Radicals: A Shock Tube - VUV Photoionization Mass Spectrometry Study

The pyrolytic reactions of n-propyl and i-propyl radicals and their precursors have been investigated at elevated temperatures and pressures (600 – 900 K and 5 – 8 bar). The studies were performed in a miniature high repetition rate shock tube with synchrotron vacuum ultraviolet photoionization mass spectrometry yielding comprehensive datasets of temporal and photoionization energy dependencies of reagents and products. The propyl radicals were generated by pyrolysis of alkyl nitrites. In addition to the main decomposition path, NO elimination, the mass spectra allowed an alternative minor path via HNO elimination to be identified and quantified. For the n-propyl precursor the HNO elimination route accounted for 9% of the alkyl nitrite while for the i-propyl precursor it was 2.5%. These values are in good agreement with a recent study on i-butyl radicals in the same apparatus at similar conditions. The ratio of disproportionation/recombination was obtained for n- propyl from the relative concentrations of n-hexane and propene and for i-propyl from 2,3-dimethyl butane and propene. For n-propyl the ratio is 0.3 and 1.2 for i-propyl, both are independent of temperature and pressure over the experimental range. The disproportionation/recombination ratios are about a factor of 2 higher than prior evaluations that are based mainly on room temperature data. The experimental results are some of the first from the apparatus used and comments are made about the technique, challenges encountered, and suggestions for future developments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photochemistry sample sticks for inelastic neutron scattering

Every material experiences atomic and molecular motions that are generally termed vibrations in gases and liquids or phonons in solid state materials. Optical spectroscopy techniques, such as Raman, infrared absorption spectroscopy, or inelastic neutron scattering (INS), can be used to measure the vibrational/phonon spectrum of ground state materials properties. A variety of optical pump probe spectroscopies enable the measurement of excited states or elucidate photochemical reaction pathways and kinetics. So far, it has not been possible to study photoactive materials or processes in situ using INS due to the mismatch between neutron and photon penetration depths, differences between the flux density of photons and neutrons, cryogenic temperatures for INS measurements, vacuum conditions, and a lack of optical access to the sample space. These experimental hurdles have resulted in very limited photochemistry studies using INS. Here we report on the design of two different photochemistry sample sticks that overcome these experimental hurdles to enable in situ photochemical studies using INS, specifically at the VISION instrument at Oak Ridge National Laboratory. We demonstrate the use of these new measurement capabilities through (1) the in situ photodimerization of anthracene and (2) the in situ photopolymerization of a 405 nm photoresin using 405 nm excitation as simple test cases. Furthermore, these new measurement apparatus broaden the science enabled by INS to include photoactive materials, optically excited states, and photoinitiated reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Response of a Pressurized Water Reactor Dashpot Region to Commercial Drying Cycles

The purpose of this report is to document updates to the simulation of commercial vacuum drying procedures at the Nuclear Energy Work Complex at Sandia National Laboratories. Validation of the extent of water removal in a dry spent nuclear fuel storage system based on drying procedures used at nuclear power plants is needed to close existing technical gaps. Operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system. A general lack of data suitable for model validation of commercial nuclear canister drying processes necessitates additional, well-designed investigations of drying process efficacy and water retention. Scaled tests that incorporate relevant physics and well-controlled boundary conditions are essential to provide insight and guidance to the simulation of prototypic systems undergoing drying processes. This report documents testing updates for the Dashpot Drying Apparatus (DDA), an apparatus constructed at a reduced scale with multiple Pressurized Water Reactor (PWR) fuel rod surrogates and a single guide tube dashpot. This apparatus is fashioned from a truncated 5×5 section of a prototypic 17×17 PWR fuel skeleton and includes the lowest segment of a single guide tube, often referred to as the dashpot region. The guide tube in this assembly is open and allows for insertion of a poison rod (neutron absorber) surrogate.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗