Search NASA⌕ Search

SEARCH · Search NASA

Results for “Vapor cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

On the comparison between equilibrium and disequilibrium condensation sequences of meteorites

A definition is presented of a simple formalism for calculating the condensation sequence of meteoritic minerals in a cooling vapor phase in temperature disequilibrium (between the vapor phase and the condensed phase) when such minerals condense congruently. Certain preliminary comments are made about the possibility of judging the relative plausibility of the equilibrium and the disequilibrium models from the observations in meteorites if a monotonic cooling were indeed the course of condensation in either case.

De, B. R.↗

Active cooling requirements for propellant storage

Recent NASA and DOD mission models have indicated future needs for orbital cryogenic storage and supply systems. Two thermal control systems which show the greatest promise for improving propellant storage life were evaluated. One system was an open cycle thermodynamic vent type with a refrigeration system for partial hydrogen reliquefaction located at the LH2 tank and a vapor cooled shield for integrated and non-integrated tank designs to reduce boiloff. The other was a closed system with direct refrigeration at the LH2 tank. A reversed Brayton cycle unit was baselined for the propellant processor. It is concluded that: (1) reliquefaction systems are not attractive for minimizing propellant boiloff; (2) open cycle systems may not be economically attractive for long term storage; (3) a number of refrigeration systems are available to assist in the long term storage of cryogenic propellants; and (4) shields can significantly improve the performance of mechanical coolers.

Klein, G. A.↗

Cryogenic and thermal design for the Space Infrared Telescope Facility (SIRTF)

The 1-meter class cryogenically cooled Space Infrared Telescope Facility (SIRTF) planned by NASA, is scheduled for a 1992 launch. SIRTF would be deployed from the Shuttle, and placed into a sun synchronous polar orbit of 700 km. The facility has been defined for a mission with a minimum initial lifetime of one year in orbit with mission extension that could be made possible through in-orbit servicing of the superfluid helium cryogenic system, and use of a thermal control system. The superfluid dewar would use an orbital disconnect system for the tank supports, and vapor cooling of the barrel baffle. The transient analysis of the design shows that the superfluid helium tank with no active feedback comes within temperature requirements for the nominal orbital aperture heat load, quiescent instrument, and chopper conditions.

Lee, J. H.↗

Space Flight Qualification Program for the AMS-2 Commercial Cryocoolers

The Alpha Magnetic Spectrometer-02 (AMS-02) experiment is a state-of-the-art particle physics detector containing a large superfluid helium-cooled superconducting magnet. Highly sensitive detector plates inside the magnet measure a particle's speed, momentum, charge, and path. The AMS-02 experiment will study the properties and origin of cosmic particles and nuclei including antimatter and dark matter. AMS-02 will be installed on the International Space Station on Utilization Flight-4. The experiment will be run for at least three years. To extend the life of the stored cryogen and minimize temperature gradients around the magnet, four Stirling-cycle Sunpower M87N cryocoolers will be integrated with AMS-02. The cryocooler cold tip will be connected via a flexible strap to the outer vapor cooled shield of the dewar. Initial thermal analysis shows the lifetime of the experiment is increased by a factor of 2.8 with the use of the cryocooler. The AMS-02 project selected the Sunpower M87 cryocoolers and has asked NASA Goddard to qualify the cryocoolers for space flight use. This paper describes the interfaces with the cryocoolers and presents data collected during testing of the two engineering model cryocoolers. Tests include thermal performance characterization and launch vibration testing. Magnetic field compatibility testing will be presented in a separate paper at the conference.

Shirey, K. A.↗

Modeling Efforts to Gain Insight into Historical Leak Events from the Single-Shell Tank A-105 in the Hanford 241-A Tank Farm - 20113

The 241-A Tank Farm is a single-shell tank (SST) farm constructed to store process waste from Hanford nuclear operations. Millions of gallons of nuclear waste were stored in the 241-A Tank Farm SSTs and some of the SSTs leaked in the past. In addition, spills and pipeline leaks during transfers and storage and intentional discharges to cribs and trenches resulted in releasing waste to the ground. Tank liner leaks are referred to as 'leaks' and all other discharges to the soil are referred to as 'releases.' Liquid waste that could be removed by pumping has been removed from all of the SSTs to reduce the potential for future leaks. The most significant historical leak event in 241-A Tank Farm occurred in 1965 when tank A-105 experienced a pressurized steam event. This event resulted in damage to the inner steel liner flooring of A-105, which was separated from the sidewalls over part of its circumference and buckled up to 2.5 m, vertically. During this event up to 7,570 L of contaminated liquid may have leaked to the adjacent soil. This leak occurred under extreme temperature and pressure conditions. Modeling efforts to better understand the nature and extent of historical leaks from subsurface SSTs that were used to store highly radioactive, self-boiling liquid wastes at 241-A Tank Farm have recently been undertaken. These efforts have compiled the available historical information to support a preliminary non-isothermal, multiphase flow and chemical transport modeling effort to re-create the conditions under which the leaks occurred and to formulate a conceptual model as to the extent and distribution of leaked radioactive contaminants in the adjacent soil material. The focus of this work was on developing an understanding of the key features, processes and bounding conditions related to tank A-105 leak events that occurred in the 1960's. The activities include estimation of leak composition, non-isothermal multiphase flow and transport modeling, and geochemical modeling. The STOMP{sup C} Water-Air-Energy modeling code was utilized to implement the three-dimensional representation of the subsurface tank and the surrounding flow field. Once constructed, the model was used to evaluate the conceptual understanding of leaks originating from different parts of the tank under the elevated temperature boundary conditions that were imposed by surrounding tanks at the time of the historical leaks. The chemical evolution of the liquid waste was also evaluated as it leaked from the tank under transient pressure and temperature gradients. The results of the preliminary evaluation suggested the presence of a heat-pipe effect beneath tank A-105 in which water vapor at an elevated temperature is driven away from the base of the tank to a position where water vapor cools, condenses and is then drawn back toward the tank by the strong capillary attraction of the dry soil. A non-sorbing contaminant (Tc-99) was introduced into this flow field to better understand the potential distribution patterns of leaked contaminants that may have occurred during the historical leak events. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effects of multiple simultaneous faults on characteristic fault detection features of a heat pump in cooling mode

Faults in air-cooled vapor compression air-conditioning systems are known to reduce performance, including efficiency, capacity, and lifespan. Their effects have been studied, and fault detection and diagnostic (FDD) methods have been developed as tools for field technicians to install or repair systems, or for monitoring to alert operators to the fault’s presence. Most of this work has focused on faults that occur singly. It is likely that in some systems, multiple faults occur simultaneously, but it is uncertain what effects this may have on diagnostics. Here, this paper describes a laboratory study of a split system air source heat pump in which combinations of two, three, and four simultaneous faults occur. The study includes all combinations of: improper evaporator airflow; overcharge or undercharge of refrigerant; liquid line restrictions; and non-condensable gas in the refrigerant, each at multiple fault intensities. Fault features – those characteristics that can be determined from measurements, for use in diagnostics – are analyzed, and the key fault features are presented. A robust existing method for determining refrigerant charge, the virtual refrigerant charge sensor (VRC) is tested using the multiple fault data, in order to understand how its performance is impacted by the combined faults. The VRC performs well, typically able to correctly determine whether a system is undercharged or overcharged, but the magnitude estimates are impacted. The results suggest that simple subcooling-based methods of charging a system are likely to provide unsatisfactory results when other faults are present.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-accuracy method for modeling nucleation and growth of particles

State-of-the-art numerical models describing the kinetics of aerosol particle nucleation and growth from a cooling vapor primarily use a nodal method, in which particles that are smaller than the critical size are omitted from consideration because they are thermodynamically unfavorable. This omission is based on the assumption that most newly formed particles are above the critical size, so that subcritical-size particles are not important to take into account. Due to the nature of the nodal method, it suffers from numerical diffusion, which can cause an artificial broadening of the cluster size distribution leading to a significant overestimation of the number of large-size particles. To address these issues, we propose a more accurate numerical method that explicitly models particles of all sizes, and uses a special numerical scheme that substantially reduces the numerical diffusion and provides high solution accuracy and numerical stability. We extensively compare this novel method to the commonly used nodal solver of the general dynamic equation (GDE) for particle growth and demonstrate that it offers GDE solutions with higher accuracy with low numerical diffusion. Incorporating small subcritical clusters into the solution is crucial for: 1) more precise determination of the entire particle size distribution function and 2) wider applicability of the model to experimental studies with non-monotonic temperature variations leading to particle evaporation. The computational code implementing this numerical method in Python is available upon request.

42 ENGINEERING↗

NUMERICAL INVESTIGATION OF FUEL PROPERTY EFFECTS ON MIXED-MODE COMBUSTION IN A SPARK-IGNITION ENGINE

In the present study, mixed-mode combustion of an E30 fuel in a direct-injection spark-ignition engine is numerically investigated at a fuel-lean operating condition using multidimensional computational fluid dynamics (CFD). A fuel surrogate matching Research Octane Number (RON) and Motor Octane Number (MON) of E30 is first developed using neural network based non-linear regression model. To enable efficient 3D engine simulations, a 164-species skeletal reaction mechanism incorporating NO, chemistry is reducedfrom a detailed chemical kinetic model. A hybrid approach that incorporates the G-equation model for tracking turbulentflame front, and the multi-zone well-stirred reactor model for predicting auto-ignition in the end gas, is employed to account for turbulent combustion interactions in the engine cylinder. Predicted in-cylinder pressure and heat release rate traces agree well with experimental measurements. The proposed modelling approach also captures moderated cyclic variability. Two different types of combustion cycles, corresponding to purely deflagrative and mixed-mode combustion, are observed. In contrast to the purely deflagrative cycles, mixed-mode combustion cycles feature early flame propagation followed by end-gas auto-ignition, leading to two distinctive peaks in heat release rate traces. The positive correlation between mixed-mode combustion cycles and early flame propagation is well captured by simulations. With the validated numerical setup, effects of NOx chemistry on mixed-mode combustion predictions are investigated. NOx chemistry is found to promote auto-ignition through residual gas recirculation, while the deflagrative flame propagation phase remains largely unaffected. Local sensitivity analysis is then performed to understand effects of physical and chemical properties of the fuel, i.e., heat of evaporation (HoV) and laminar flame speed (S-L). An increased HoV tends to suppress end-gas auto-ignition due to increased vaporization cooling, while the impact of HoV on flame propagation is insignificant. In contrast, an increased SL is found to significantly promote both flame propagation and auto-ignition. The promoting effect of SL on auto-ignition is not a direct chemical effect; it is rather caused by an advancement of the combustion phasing, which increases compression heating of the end gas.

detailed chemical kinetics↗

Tank-Integrated Heat Exchanger for Boil-Off Reduction

The following document details the initial efforts of the Protium Company in developing reduced boil-off and zero boil-off liquid hydrogen tanks using Vapor-Cooled Shielding (VCS) technology. The intention is to improve upon the performance characteristics of traditional vacuum-jacketed dewars by reducing boil-off rate, cooldown time, and total boil-off during cooldown time while integrating the heat exchanger into the wall of the VCS tank. The work carried out during this project was limited, as the grant recipient The Protium Company was acquired by Plug Power Inc. on October 1st 2021, early in the performance period of the grant. As such, the extent of the work completed includes an initial estimation of the dimensions needed for a 0.1%/day boil-off VCS liquid hydrogen tank. These dimensions are derived from data gathered from sizes of previous VCS tanks. The dimensions and estimated boil-off rate for the VCS tank are by no means validated, and no design was generated for a zero boil-off tank.

08 HYDROGEN↗

Cryogenic storage tank thermal analysis

Parametric study discusses relationship between cryogenic boil-off and factors such as tank size, insulation thickness and performance, structural-support heat leaks and use of vapor-cooled shields. Data presented as series of nomographs and curves.

Wright, J. P.↗

Heat Pipe Technology: A bibliography with abstracts

This bibliography lists 149 references with abstracts and 47 patents dealing with applications of heat pipe technology. Topics covered include: heat exchangers for heat recovery; electrical and electronic equipment cooling; temperature control of spacecraft; cryosurgery; cryogenic, cooling; nuclear reactor heat transfer; solar collectors; laser mirror cooling; laser vapor cavitites; cooling of permafrost; snow melting; thermal diodes variable conductance; artery gas venting; and venting; and gravity assisted pipes.

Source record↗

Cryogenic Hydrogen/helium Storage and Supply System, Phase 1

An existing cryogenic tank was refurbished, microspheres were installed in the tank annulus, and the thermal performance of the unit was tested. The performance data was compared with NRC-2 multilayer insulation and low emittance aluminized surfaces installed in tanks of the same basic design. The cryogenic tank modified during the program was originally designed for the Manned Orbiting Laboratory (MOL) Program, and subsequently modified by vacuum-depositing aluminum on all annulus surfaces and leaving out the NRC-2 multilayer insulation. It is concluded that the application of aluminized-microsphere insulation is not yet very predictable for tank design purposes, especially at LH2 temperature and in the presence of a vapor-cooled shield.

Norman, R. H.↗

Comparative thermal analysis of alternate Cryogenic Fluid Management Experiment (CFME) configurations

The Cryogenic Fluid Management Experiment (CFME) was analyzed to assess the feasibility and advisability of deleting the vapor cooled shield (VCS) from the baseline CFME insulation and pressure control system. Two alternate concepts of CFME insulation and pressure control, neither of which incorporated the VCS, were investigated. The first concept employed a thermodynamic vent system (TVS) to throttle the flow through an internal wall mounted heat exchanger (HX) within the pressure vessel to decrease boiloff and pressure rise rate, while the second concept utilized a TVS without an internal heat exchanger. Only the first concept was viable. Its performance was assessed for a seven day mission and found to be satisfactory. It was also concluded that VCS development costs would be greater than for an internal HX installation. Based upon the above comparisons, the HX was recommended as a replacement for the VCS.

Merino, F.↗

Feasibility study for long lifetime helium dewar

A feasible concept for a launchable three year lifetime helium dewar was investigted. Current helium dewar designs were examined to see where the largest potential reductions in parasitic heat loads can be made. The study was also devoted to examining support concepts. The support concept chosen, a passive orbital disconnect strut (PODS), has an orbital support conductance that is lower by more than an order of magnitude over current tension band supports. This lower support conductance cuts the total dewar weight in half for the same three year life time requirements. Effort was also concentrated on efficient wire feed through designs and vapor cooling of the multilayer insulation, supports, wire feed throughs and plumbing penetrations. A single stage helium dewar vs. dual stage dewars with a guard cryogen of nitrogen or neon was examined. The single stage dewar concept was selected. Different support concepts were analyzed from which the PODS support concepts was chosen. A preliminary design of the dewar was thermally and structurally analyzed and laid out including system weights, thermal performance and performance sensitivities.

Parmley, R. T.↗

Passive Orbital Disconnect Strut (PODS 3), structural and thermal test program

A test program is undertaken to verify that the lifetime of a shuttle launchable dewar can be increased by using passive orbital disconnect struts (PODS). A detailed design is performed on the cold end (PODS-III) portion of the strut. Structural analysis of the thin-wall fiberglass tube allows selection of the optimum winding angle and tube dimensions. Structural tests on the thin-wall fiberglass tube measure both the tension and compression modulus at ambient and LN2 temperatures, the radial deflection versus side load, and the ultimate compression strength of the tube at LN2 temperature. The thermal expansion of the fiberglass tube plus Invar is also measured down to 78 K. The axial gap at the wedge portion of the stem is set based on these data. The PODS-III test article parts are fabricated and assembled using a detailed assembly procedure. The thermal conductants in the orbital configuration was measured for body temperatures between 5 and 40 K. This temperature range covers the predicted ground hold and orbit temperatures for vapor-cooled supports. The test results are then compared with heat leak values predicted before the test began. Side load, axial compression load, and tension load tests conclude the test program.

Parmley, R. T.↗

Progress report on the infrared astronomical satellite cryogenic system

The main cryogen tank is sized to hold 70 kg of superfluid helium with 12 percent ullage at a temperature of 1.8 K. The insulation system surrounds the main cryogen tank with four blankets of multilayer insulation spaced by means of three vapor-cooled shields. It is noted that the multilayer insulation is 6.4 micron double-aluminized Mylar separated by polyester net. The main shell provides the primary structural integrity of the system. In orbit the main shell is cooled to 170 K using insulation blankets on one side and second surface paint on the opposite side. The aperture cover subassembly is the vacuum seal for the main shell during operation on the ground. It is also a gas condensation trap before and during cooldown of the main cryogen tank during launch hold. It contains 6 kg of supercritical helium, which permits 14 days on orbit with a 48-hour launch pad hold.

Urbach, A. R.↗

Improvements in Ionized Cluster-Beam Deposition

Lower temperatures result in higher purity and fewer equipment problems. In cluster-beam deposition, clusters of atoms formed by adiabatic expansion nozzle and with proper nozzle design, expanding vapor cools sufficiently to become supersaturated and form clusters of material deposited. Clusters are ionized and accelerated in electric field and then impacted on substrate where films form. Improved cluster-beam technique useful for deposition of refractory metals.

Fitzgerald, D. J.↗