Search NASA⌕ Search

SEARCH · Search NASA

Results for “Venting valve”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Calibrating the Helium Pressurization System for the Space Shuttle Liquid-Hydrogen Tank

Analysis of the results from the STS-114 tanking tests and subsequent launch called into question existing thermal and mass models of helium pressurization of the liquid hydrogen tank. This hydrogen tank, which makes up the bottom two-thirds of the External Tank, is pressurized prior to launch to avoid cavitation in the Shuttle Main Engine pumps. At about 2 minutes prior to launch, the main vent valve is closed, and pressurized helium flows into the tank ullage space to achieve set point pressure. As the helium gas cools, its pressure drops, calling for additional helium. Subsequent helium flows are provided in short, timed pulses. The number of pulses is taken as a rough leak indicator. An analysis of thermal models by Marshall Space Flight Center showed considerable uncertainty in the pressure-versus-time behavior of the helium ullage space and the ability to predict the number of pulses normally expected. Kennedy Space Center proposed to calibrate the dime-sized orifice, which together with valves, controls the helium flow quantity (Figure 1). Pressure and temperature sensors were installed to provide upstream and downstream measurements necessary to compute flow rate based on the orifice discharge coefficient. An assessment of flow testing with helium indicated an extremely costly use of this critical resource. In order to reduce costs, we proposed removing the orifices from each Mobile Launcher Platform (MLP) and asking Colorado Engineering Experiment Station Inc. (CEESI) to calibrate the flow. CEESI has a high-pressure air flow system with traceable flow meters capable of handling the large flow rates. However, literature research indicated that square-edged orifices of small diameters often exhibit significant hysteresis and nonrepeatability in the vicinity of choked or sonic flow. Fortunately, the MLP orifices behaved relatively well in testing (Figure 2). Using curve fitting of the air-flow data, in conjunction with ASME orifice modeling equations, a method of relating the helium mass flow to measured air flow data was obtained. This analysis showed that the highest uncertainty in flow occurred in the vicinity of the choking pressure ratio, as would be expected. In addition, analysis of typical flow pulses showed that most of the helium flow occurred either well below or well above this uncertain area. The final result is the ability to provide postlaunch estimates of helium mass flows that are within 1.5 percent of the actual value.

Source record↗

Large-Scale Liquid Hydrogen Tank Rapid Chill and Fill Testing for the Advanced Shuttle Upper Stage Concept

Cryogenic upper stages in the Space Shuttle program were prohibited primarily due to a safety risk of a 'return to launch site' abort. An upper stage concept addressed this concern by proposing that the stage be launched empty and filled using shuttle external tank residuals after the atmospheric pressure could no longer sustain an explosion. However, only about 5 minutes was allowed for tank fill. Liquid hydrogen testing was conducted within a near-ambient environment using the multipurpose hydrogen test bed 638.5 ft3 (18m3) cylindrical tank with a spray bar mounted longitudinally inside. Although the tank was filled within 5 minutes, chilldown of the tank structure was incomplete, and excessive tank pressures occurred upon vent valve closure. Elevated tank wall temperatures below the liquid level were clearly characteristic of film boiling. The test results have substantial implications for on-orbit cryogen transfer since the formation of a vapor film would be much less inhibited due to the reduced gravity. However, the heavy tank walls could become an asset in normal gravity testing for on-orbit transfer, i.e., if film boiling in a nonflight weight tank can be inhibited in normal gravity, then analytical modeling anchored with the data could be applied to reduced gravity environments with increased confidence.

Flachbart, R. H.↗

Implications of Wind-Assisted Aerial Navigation for Titan Mission Planning and Science Exploration

The recent Titan Saturn System Mission (TSSM) proposal incorporates a montgolfiere (hot air balloon) as part of its architecture. Standard montgolfiere balloons generate lift through heating of the atmospheric gases inside the envelope, and use a vent valve for altitude control. A Titan aerobot (robotic aerial vehicle) would have to use radioisotope thermoelectric generators (RTGs) for electric power, and the excess heat generated can be used to provide thermal lift for a montgolfiere. A hybrid montgolfiere design could have propellers mounted on the gondola to generate horizontal thrust; in spite of the unfavorable aerodynamic drag caused by the shape of the balloon, a limited amount of lateral controllability could be achieved. In planning an aerial mission at Titan, it is extremely important to assess how the moon-wide wind field can be used to extend the navigation capabilities of an aerobot and thereby enhance the scientific return of the mission. In this paper we explore what guidance, navigation and control capabilities can be achieved by a vehicle that uses the Titan wind field. The control planning approach is based on passive wind field riding. The aerobot would use vertical control to select wind layers that would lead it towards a predefined science target, adding horizontal propulsion if available. The work presented in this paper is based on aerodynamic models that characterize balloon performance at Titan, and on TitanWRF (Weather Research and Forecasting), a model that incorporates heat convection, circulation, radiation, Titan haze properties, Saturn's tidal forcing, and other planetary phenomena. Our results show that a simple unpropelled montgolfiere without horizontal actuation will be able to reach a broad array of science targets within the constraints of the wind field. The study also indicates that even a small amount of horizontal thrust allows the balloon to reach any area of interest on Titan, and to do so in a fraction of the time needed by the unpropelled balloon. The results show that using the Titan wind field allows an aerobot to significantly extend its scientific reach, and that a montgolfiere (unpropelled or propelled) is a highly desirable architecture that can very significantly enhance the scientific return of a future Titan mission.

aerobot↗

Numerical Modeling of No Vent Filling of a Cryogenic Tank with Thermo-dynamic Vent System Assisted Injector

This paper presents a multi-node finite volume model of No Vent Filling (NVF) of a cryogenic tank with Thermo-dynamic Vent System (TVS) assisted injector, using the Generalized Fluid System Simulation Program (GFSSP), a general purpose flow network code. NVF tests were conducted in a CRYOgenic Orbital Testbed (CRYOTE) tank which was filled by liquid nitrogen using a TVS assisted injector with vent valve closed during the entire filling process. In TVS assisted injector, the liquid flow splits into two streams: one stream is routed to a Joule-Thomson (J-T) orifice where the flow immediately flashes from liquid to vapor or two phase mixture because the downstream to J-T leg is maintained at vacuum level.; the other stream is injected into the tank after being cooled by cold vapor of J-T leg in a heat exchanger. The flow through J-T leg is also used to cool the outer metal matrix of the injector which in turn cools the vapor in the tank ullage. The cooling of vapor in the ullage by cold injector surface reduces ullage pressure that allows liquid to enter and fill the tank. An integrated numerical model of the test set up was developed. The model included the dual lines of TVS assisted injector, tank and tank wall. The tank was discretized into multiple fluid nodes and branches to represent the ullage and liquid nitrogen and multiple solid nodes to represent the tank wall and structure. The heat transfer between solid to fluid was calculated from pool boiling correlations which include film, transition, and nucleate boiling, as well as natural convection during pre- and post-boiling. The model also accounts for the condensation of vapor at ullage-injector interface and when it comes in contact with the liquid spray. The predicted pressure, resident mass, wall temperature in the tank were compared with the test data.

Alok Majumdar↗

Surface Instability of Liquid Propellants in Microgravity During Pulsed Settling Operations

Pulsing reaction control system (RCS) thrusters, vent valves, or other propulsion devices can preserve propellant resources in space, but this operation also effectively introduces a vibration to the vehicle. When the vibration is perpendicular to the liquid propellant surface, Faraday waves may be generated at the liquid-vapor interface. These Faraday instabilities can perturb or break up the liquid surface of cryogenic tanks, leading to inefficiencies in thermal management or even ullage collapse. Drawing from theory and experiments, an engineering model defining the allowable design regions for pulsed settling in microgravity was assembled and verified with computational fluid dynamics (CFD) simulations. A traditional settling metric, the Bond number, was also overlaid in the model to indicate which duty cycles were insufficient to overcome surface tension and aggregate propellant. Mission planners and engineers can consult the tool to rapidly evaluate the stability of a liquid-vapor interface given the pulse frequency and the excitation acceleration. Expressions developed for Faraday waves induced by a sinusoidal forcing input at standard gravity were found to provide excellent predictive capabilities for pulsed, or rectangular, waveforms in the absence of a consistent gravitational acceleration. This study extends the usage of these equations to an alternative forcing function and microgravity environments for the purpose of estimating natural frequencies, surface mode shapes, surface wave amplitudes, and the onset of droplet ejection. CFD simulations with the Loci/STREAM-VoF (Volume of Fluid) solver were initially validated against experimental results in standard gravity. Discrete points on the design map were then investigated with CFD and confirmed that the engineering model reliably indicates surface stability and most Faraday wave characteristics without requiring higher-fidelity tools. The engineering model is highly extensible and can be adapted for various propellant fill fractions, fluid properties, and tank sizes.

Faraday Waves↗

Surface Instability of Liquid Propellants in Microgravity During Pulsed Settling Operations

Pulsing reaction control system (RCS) thrusters, vent valves, or other propulsion devices can preserve propellant resources in space, but this operation also effectively introduces a vibration to the vehicle. When the vibration is perpendicular to the liquid propellant surface, Faraday waves may be generated at the liquid-vapor interface. These Faraday instabilities can perturb or break up the liquid surface of cryogenic tanks, leading to inefficiencies in thermal management or even ullage collapse. Drawing from theory and experiments, an engineering model defining the allowable design regions for pulsed settling in microgravity was assembled and verified with computational fluid dynamics (CFD) simulations. A traditional settling metric, the Bond number, was also overlaid in the model to indicate which duty cycles were insufficient to overcome surface tension and aggregate propellant. Mission planners and engineers can consult the tool to rapidly evaluate the stability of a liquid-vapor interface given the pulse frequency and the excitation acceleration. Expressions developed for Faraday waves induced by a sinusoidal forcing input at standard gravity were found to provide excellent predictive capabilities for pulsed, or rectangular, waveforms in the absence of a consistent gravitational acceleration. This study extends the usage of these equations to an alternative forcing function and microgravity environments for the purpose of estimating natural frequencies, surface mode shapes, surface wave amplitudes, and the onset of droplet ejection. CFD simulations with the Loci/STREAM-VoF (Volume of Fluid) solver were initially validated against experimental results in standard gravity. Discrete points on the design map were then investigated with CFD and confirmed that the engineering model reliably indicates surface stability and most Faraday wave characteristics without requiring higher-fidelity tools. The engineering model is highly extensible and can be adapted for various propellant fill fractions, fluid properties, and tank sizes.

Faraday Waves↗

Integral valve provides automatic relief and remote venting

In-line, pilot-operated, differential area, poppet type valve provides both automatic relief of a tank at a precise over-pressure and remote control of tank venting. Relief and vent operations are separate functions incorporated in an integral valve package.

Gilmore, R. F.↗

Inexpensive Pressure-Relief Valve

Simple device vents excess low-pressure gas. Inexpensive pressure relief valve built from polyvinylchloride pipe. Valve suitable for low pressure-- 25 to 50 cm of mercury-- and flow rates up to 14 m3/min.

Theordore, E. A.↗

Shuttle Gaseous Hydrogen Venting Risk from Flow Control Valve Failure

This paper describes a series of studies to assess the potential risk associated with the failure of one of three gaseous hydrogen flow control valves in the orbiter's main propulsion system during the launch of Shuttle Endeavour (STS-126) in November 2008. The studies focused on critical issues associated with the possibility of combustion resulting from release of gaseous hydrogen from the external tank into the atmosphere during assent. The Shuttle Program currently assumes hydrogen venting from the external tank will result in a critical failure. The current effort was conducted to increase understanding of the risk associated with venting hydrogen given the flow control valve failure scenarios being considered in the Integrated In-Flight Anomaly Investigation being conducted by NASA.

Drummond, J. Philip↗

A unified thermal and vertical trajectory model for the prediction of high altitude balloon performance

A computer model for the prediction of the trajectory and thermal behavior of zero-pressure high altitude balloon was developed. In accord with flight data, the model permits radiative emission and absorption of the lifting gas and daytime gas temperatures above that of the balloon film. It also includes ballasting, venting, and valving. Predictions obtained with the model are compared with flight data from several flights and newly discovered features are discussed.

Carlson, L. A.↗

A new thermal and trajectory model for high altitude balloons

A new computer model for the prediction of the trajectory and thermal behavior of high altitude balloons has been developed. In accord with flight data, the model permits radiative emission and absorption of the lifting gas and daytime gas temperatures above that of the balloon film. It also includes ballasting, venting, and valving. Predictions obtained with the model are compared with flight data and newly discovered features are discussed.

Carlson, L. A.↗

Technology test bed engine real-time failure control

The Real-Time Failure Control (RTFC) program involves development of a failure detection algorithm, for the Space Shuttle Main Engine (SSME). This failure detection approach is signal-based and entails monitoring SSME measurement signals based on predetermined as well as on-line computed mean and standard deviation values. Twenty-four engine measurements are monitored in the algorithm and provisions are made to add more parameters if needed. Each of the first values of every measurement signal at the algorithm start is checked against safety limits placed around a pre-computed engine-to-engine mean value (MV) with a bandwidth equal to a given multiple of the pre-computed standard deviation (SD). If several parameters are out of the bounds of these limits a failure is signaled. During the first two seconds (after algorithm start) a moving average (MA) and a SD is computed on-line in real-time. The moving average of each parameter is computed by averaging the incoming signal measurement with the four most recent previous signal measurements. The moving average is updated at every sampling interval (40 msec) and is checked against a similar safety band around the initial signal value for each parameter. If several anomalies are registered, a failure is signaled by the algorithm. At the end of the two-second interval the MA is fixed as the mean value for the rest of the algorithm operation and a safety band is placed above and below this value equal to a multiple of the computed SD. However, the safety band is adjusted by adjusting the mean value when propellant tank repressurization and venting take place. 'Influence Coefficients' are used to make the necessary adjustments to the safety limits of those parameters that are affected by repressurization and venting or valve closure and opening. The MA is, in both cases, continuously updated and checked against the safety band. Once more, if several parameters exceed the limits a failure is signaled. At the start of every scheduled power transient the algorithm is stopped. It is re-initiated after two seconds from the termination of the power transient and the process is repeated. The final report is divided into four major sections. The most encompassing of all is the discussion section that has sub-sections on: (1) RTFC algorithm development, (2) RTFC simulations; (3) RTFC current limitations; and (4) enhancements planned for.

Panossian, Hagop V.↗

Improved Relief Valve Would Be Less Susceptible to Failure

The balanced-piston relief valve with side vented reaction cavity has been proposed as an improved alternative to a conventional high-pressure, high-flow relief valve. The proposed valve would be less susceptible to failure. A typical conventional high-pressure, high-flow relief valve contains a piston that is exposed to the upstream pressure across the full valve-seat diameter and is held against the valve seat and the upstream pressure by a large spring. In the event of an increase in upstream pressure to a level above the valve set point (the pressure above which the valve opens), the opening force on the piston can be so large that the piston becomes accelerated to a speed high enough that the ensuing hard impact of the piston within the valve housing results in failure of the valve. For a given flow cross section, the proposal would significantly reduce the force, thereby reducing susceptibility to failure. A basic version of the proposed balanced-piston relief valve with side vented reaction cavity is described.

Farner, Bruce R.↗

Thermodynamic Vent System for an On-Orbit Cryogenic Reaction Control Engine

A report discusses a cryogenic reaction control system (RCS) that integrates a Joule-Thompson (JT) device (expansion valve) and thermodynamic vent system (TVS) with a cryogenic distribution system to allow fine control of the propellant quality (subcooled liquid) during operation of the device. It enables zero-venting when coupled with an RCS engine. The proper attachment locations and sizing of the orifice are required with the propellant distribution line to facilitate line conditioning. During operations, system instrumentation was strategically installed along the distribution/TVS line assembly, and temperature control bands were identified. A sub-scale run tank, full-scale distribution line, open-loop TVS, and a combination of procured and custom-fabricated cryogenic components were used in the cryogenic RCS build-up. Simulated on-orbit activation and thruster firing profiles were performed to quantify system heat gain and evaluate the TVS s capability to maintain the required propellant conditions at the inlet to the engine valves. Test data determined that a small control valve, such as a piezoelectric, is optimal to provide continuously the required thermal control. The data obtained from testing has also assisted with the development of fluid and thermal models of an RCS to refine integrated cryogenic propulsion system designs. This system allows a liquid oxygenbased main propulsion and reaction control system for a spacecraft, which improves performance, safety, and cost over conventional hypergolic systems due to higher performance, use of nontoxic propellants, potential for integration with life support and power subsystems, and compatibility with in-situ produced propellants.

Hurlbert, Eric A.↗

Pilot-booster control valve

Two-stage, pressure-sensing control valve is designed for servocontrol of 10-inch main tank valve regulating pressure of liquid oxygen in tank and serving to vent tank during filling. Valve uses a negative-rate Belleville spring to cancel positive spring rates of bellows and coil springs.

Marley, D.↗

Kick-Free Pressure Release Valve

Release valve for smoothly venting buildup of gas pressure modified to reduce kickback of mechanism during discharge.

Killgrove, T. O.↗