Search NASA⌕ Search

SEARCH · Search NASA

Results for “Venting valve”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Surface Instability of Liquid Propellants in Microgravity During Pulsed Settling Operations

Pulsing reaction control system (RCS) thrusters, vent valves, or other propulsion devices can preserve propellant resources in space, but this operation also effectively introduces a vibration to the vehicle. When the vibration is perpendicular to the liquid propellant surface, Faraday waves may be generated at the liquid-vapor interface. These Faraday instabilities can perturb or break up the liquid surface of cryogenic tanks, leading to inefficiencies in thermal management or even ullage collapse. Drawing from theory and experiments, an engineering model defining the allowable design regions for pulsed settling in microgravity was assembled and verified with computational fluid dynamics (CFD) simulations. A traditional settling metric, the Bond number, was also overlaid in the model to indicate which duty cycles were insufficient to overcome surface tension and aggregate propellant. Mission planners and engineers can consult the tool to rapidly evaluate the stability of a liquid-vapor interface given the pulse frequency and the excitation acceleration. Expressions developed for Faraday waves induced by a sinusoidal forcing input at standard gravity were found to provide excellent predictive capabilities for pulsed, or rectangular, waveforms in the absence of a consistent gravitational acceleration. This study extends the usage of these equations to an alternative forcing function and microgravity environments for the purpose of estimating natural frequencies, surface mode shapes, surface wave amplitudes, and the onset of droplet ejection. CFD simulations with the Loci/STREAM-VoF (Volume of Fluid) solver were initially validated against experimental results in standard gravity. Discrete points on the design map were then investigated with CFD and confirmed that the engineering model reliably indicates surface stability and most Faraday wave characteristics without requiring higher-fidelity tools. The engineering model is highly extensible and can be adapted for various propellant fill fractions, fluid properties, and tank sizes.

Faraday Waves↗

Surface Instability of Liquid Propellants in Microgravity During Pulsed Settling Operations

Pulsing reaction control system (RCS) thrusters, vent valves, or other propulsion devices can preserve propellant resources in space, but this operation also effectively introduces a vibration to the vehicle. When the vibration is perpendicular to the liquid propellant surface, Faraday waves may be generated at the liquid-vapor interface. These Faraday instabilities can perturb or break up the liquid surface of cryogenic tanks, leading to inefficiencies in thermal management or even ullage collapse. Drawing from theory and experiments, an engineering model defining the allowable design regions for pulsed settling in microgravity was assembled and verified with computational fluid dynamics (CFD) simulations. A traditional settling metric, the Bond number, was also overlaid in the model to indicate which duty cycles were insufficient to overcome surface tension and aggregate propellant. Mission planners and engineers can consult the tool to rapidly evaluate the stability of a liquid-vapor interface given the pulse frequency and the excitation acceleration. Expressions developed for Faraday waves induced by a sinusoidal forcing input at standard gravity were found to provide excellent predictive capabilities for pulsed, or rectangular, waveforms in the absence of a consistent gravitational acceleration. This study extends the usage of these equations to an alternative forcing function and microgravity environments for the purpose of estimating natural frequencies, surface mode shapes, surface wave amplitudes, and the onset of droplet ejection. CFD simulations with the Loci/STREAM-VoF (Volume of Fluid) solver were initially validated against experimental results in standard gravity. Discrete points on the design map were then investigated with CFD and confirmed that the engineering model reliably indicates surface stability and most Faraday wave characteristics without requiring higher-fidelity tools. The engineering model is highly extensible and can be adapted for various propellant fill fractions, fluid properties, and tank sizes.

Faraday Waves↗

Integral valve provides automatic relief and remote venting

In-line, pilot-operated, differential area, poppet type valve provides both automatic relief of a tank at a precise over-pressure and remote control of tank venting. Relief and vent operations are separate functions incorporated in an integral valve package.

Gilmore, R. F.↗

Inexpensive Pressure-Relief Valve

Simple device vents excess low-pressure gas. Inexpensive pressure relief valve built from polyvinylchloride pipe. Valve suitable for low pressure-- 25 to 50 cm of mercury-- and flow rates up to 14 m3/min.

Theordore, E. A.↗

Shuttle Gaseous Hydrogen Venting Risk from Flow Control Valve Failure

This paper describes a series of studies to assess the potential risk associated with the failure of one of three gaseous hydrogen flow control valves in the orbiter's main propulsion system during the launch of Shuttle Endeavour (STS-126) in November 2008. The studies focused on critical issues associated with the possibility of combustion resulting from release of gaseous hydrogen from the external tank into the atmosphere during assent. The Shuttle Program currently assumes hydrogen venting from the external tank will result in a critical failure. The current effort was conducted to increase understanding of the risk associated with venting hydrogen given the flow control valve failure scenarios being considered in the Integrated In-Flight Anomaly Investigation being conducted by NASA.

Drummond, J. Philip↗

A unified thermal and vertical trajectory model for the prediction of high altitude balloon performance

A computer model for the prediction of the trajectory and thermal behavior of zero-pressure high altitude balloon was developed. In accord with flight data, the model permits radiative emission and absorption of the lifting gas and daytime gas temperatures above that of the balloon film. It also includes ballasting, venting, and valving. Predictions obtained with the model are compared with flight data from several flights and newly discovered features are discussed.

Carlson, L. A.↗

A new thermal and trajectory model for high altitude balloons

A new computer model for the prediction of the trajectory and thermal behavior of high altitude balloons has been developed. In accord with flight data, the model permits radiative emission and absorption of the lifting gas and daytime gas temperatures above that of the balloon film. It also includes ballasting, venting, and valving. Predictions obtained with the model are compared with flight data and newly discovered features are discussed.

Carlson, L. A.↗

Technology test bed engine real-time failure control

The Real-Time Failure Control (RTFC) program involves development of a failure detection algorithm, for the Space Shuttle Main Engine (SSME). This failure detection approach is signal-based and entails monitoring SSME measurement signals based on predetermined as well as on-line computed mean and standard deviation values. Twenty-four engine measurements are monitored in the algorithm and provisions are made to add more parameters if needed. Each of the first values of every measurement signal at the algorithm start is checked against safety limits placed around a pre-computed engine-to-engine mean value (MV) with a bandwidth equal to a given multiple of the pre-computed standard deviation (SD). If several parameters are out of the bounds of these limits a failure is signaled. During the first two seconds (after algorithm start) a moving average (MA) and a SD is computed on-line in real-time. The moving average of each parameter is computed by averaging the incoming signal measurement with the four most recent previous signal measurements. The moving average is updated at every sampling interval (40 msec) and is checked against a similar safety band around the initial signal value for each parameter. If several anomalies are registered, a failure is signaled by the algorithm. At the end of the two-second interval the MA is fixed as the mean value for the rest of the algorithm operation and a safety band is placed above and below this value equal to a multiple of the computed SD. However, the safety band is adjusted by adjusting the mean value when propellant tank repressurization and venting take place. 'Influence Coefficients' are used to make the necessary adjustments to the safety limits of those parameters that are affected by repressurization and venting or valve closure and opening. The MA is, in both cases, continuously updated and checked against the safety band. Once more, if several parameters exceed the limits a failure is signaled. At the start of every scheduled power transient the algorithm is stopped. It is re-initiated after two seconds from the termination of the power transient and the process is repeated. The final report is divided into four major sections. The most encompassing of all is the discussion section that has sub-sections on: (1) RTFC algorithm development, (2) RTFC simulations; (3) RTFC current limitations; and (4) enhancements planned for.

Panossian, Hagop V.↗

Improved Relief Valve Would Be Less Susceptible to Failure

The balanced-piston relief valve with side vented reaction cavity has been proposed as an improved alternative to a conventional high-pressure, high-flow relief valve. The proposed valve would be less susceptible to failure. A typical conventional high-pressure, high-flow relief valve contains a piston that is exposed to the upstream pressure across the full valve-seat diameter and is held against the valve seat and the upstream pressure by a large spring. In the event of an increase in upstream pressure to a level above the valve set point (the pressure above which the valve opens), the opening force on the piston can be so large that the piston becomes accelerated to a speed high enough that the ensuing hard impact of the piston within the valve housing results in failure of the valve. For a given flow cross section, the proposal would significantly reduce the force, thereby reducing susceptibility to failure. A basic version of the proposed balanced-piston relief valve with side vented reaction cavity is described.

Farner, Bruce R.↗

Thermodynamic Vent System for an On-Orbit Cryogenic Reaction Control Engine

A report discusses a cryogenic reaction control system (RCS) that integrates a Joule-Thompson (JT) device (expansion valve) and thermodynamic vent system (TVS) with a cryogenic distribution system to allow fine control of the propellant quality (subcooled liquid) during operation of the device. It enables zero-venting when coupled with an RCS engine. The proper attachment locations and sizing of the orifice are required with the propellant distribution line to facilitate line conditioning. During operations, system instrumentation was strategically installed along the distribution/TVS line assembly, and temperature control bands were identified. A sub-scale run tank, full-scale distribution line, open-loop TVS, and a combination of procured and custom-fabricated cryogenic components were used in the cryogenic RCS build-up. Simulated on-orbit activation and thruster firing profiles were performed to quantify system heat gain and evaluate the TVS s capability to maintain the required propellant conditions at the inlet to the engine valves. Test data determined that a small control valve, such as a piezoelectric, is optimal to provide continuously the required thermal control. The data obtained from testing has also assisted with the development of fluid and thermal models of an RCS to refine integrated cryogenic propulsion system designs. This system allows a liquid oxygenbased main propulsion and reaction control system for a spacecraft, which improves performance, safety, and cost over conventional hypergolic systems due to higher performance, use of nontoxic propellants, potential for integration with life support and power subsystems, and compatibility with in-situ produced propellants.

Hurlbert, Eric A.↗

Pilot-booster control valve

Two-stage, pressure-sensing control valve is designed for servocontrol of 10-inch main tank valve regulating pressure of liquid oxygen in tank and serving to vent tank during filling. Valve uses a negative-rate Belleville spring to cancel positive spring rates of bellows and coil springs.

Marley, D.↗

Kick-Free Pressure Release Valve

Release valve for smoothly venting buildup of gas pressure modified to reduce kickback of mechanism during discharge.

Killgrove, T. O.↗

Activation of the E1 Ultra High Pressure Propulsion Test Facility at Stennis Space Center

After a decade of construction and a year of activation the El Ultra High Pressure Propulsion Test Facility at NASA's Stennis Space Center is fully operational. The El UHP Propulsion Test Facility is a multi-cell, multi-purpose component and engine test facility . The facility is capable of delivering cryogenic propellants at low, high, and ultra high pressures with flow rates ranging from a few pounds per second up to two thousand pounds per second. Facility activation is defined as a series of tasks required to transition between completion of construction and facility operational readiness. Activating the El UHP Propulsion Test Facility involved independent system checkouts, propellant system leak checks, fluid and gas sampling, gaseous system blow downs, pressurization and vent system checkouts, valve stability testing, valve tuning cryogenic cold flows, and functional readiness tests.

Messer, Bradley↗

Cryogenic Liquid Sample Acquisition System for Remote Space Applications

There is a need to acquire autonomously cryogenic hydrocarbon liquid sample from remote planetary locations such as the lakes of Titan for instruments such as mass spectrometers. There are several problems that had to be solved relative to collecting the right amount of cryogenic liquid sample into a warmer spacecraft, such as not allowing the sample to boil off or fractionate too early; controlling the intermediate and final pressures within carefully designed volumes; designing for various particulates and viscosities; designing to thermal, mass, and power-limited spacecraft interfaces; and reducing risk. Prior art inlets for similar instruments in spaceflight were designed primarily for atmospheric gas sampling and are not useful for this front-end application. These cryogenic liquid sample acquisition system designs for remote space applications allow for remote, autonomous, controlled sample collections of a range of challenging cryogenic sample types. The design can control the size of the sample, prevent fractionation, control pressures at various stages, and allow for various liquid sample levels. It is capable of collecting repeated samples autonomously in difficult lowtemperature conditions often found in planetary missions. It is capable of collecting samples for use by instruments from difficult sample types such as cryogenic hydrocarbon (methane, ethane, and propane) mixtures with solid particulates such as found on Titan. The design with a warm actuated valve is compatible with various spacecraft thermal and structural interfaces. The design uses controlled volumes, heaters, inlet and vent tubes, a cryogenic valve seat, inlet screens, temperature and cryogenic liquid sensors, seals, and vents to accomplish its task.

Mahaffy, Paul↗

Relief Valve Opens And Closes Quickly

Relief valve opens quickly to relieve excess pressure and closes quickly when pressure drops slightly below relief pressure. O-ring exposes one or more ports under high pressure, releasing excess pressurized fluid. Adjusting screw used to change compression on Belleville-spring washers and to set pressure at which valve opens. Designed for use aboard Space Shuttle to vent pressurized hydrazine to vacuum, valve concept useful in industrial applications where rapid opening, rapid closing, or low susceptibility to blockage by vented fluid required.

Svejkovsky, Paul A.↗

Vented Chill / No-Vent Fill of Cryogenic Propellant Tanks

Architectures for extended duration missions often include an on-orbit replenishment of the space vehicle's cryogenic liquid propellants. Such a replenishment could be accomplished via a tank-to-tank transfer from a dedicated tanker or a more permanent propellant depot storage tank. Minimizing the propellant loss associated with transfer line and receiver propellant tank thermal conditioning is essential for mass savings. A new methodology for conducting tank-to-tank transfer while minimizing such losses has been demonstrated. Charge-Hold-Vent is the traditional methodology for conducting a tank-to-tank propellant transfer. A small amount of cryogenic liquid is introduced to chill the transfer line and propellant tank. As the propellant absorbs heat and undergoes a phase change, the tank internal pressure increases. The tank is then vented to relieve pressure prior to another charge of cryogenic liquid being introduced. This cycle is repeated until the transfer lines and tank are sufficiently chilled and the replenishment of the propellant tank is complete. This method suffers inefficiencies due to multiple chill and vent cycles within the transfer lines and associated feed system components. Additionally, this system requires precise measuring of cryogenic fluid delivery for each transfer, multiple valve cycling events, and other complexities associated with cycled operations. To minimize propellant loss and greatly simplify on-orbit operations, an alternate methodology has been designed and demonstrated. The Vented Chill / No Vent Fill method is a simpler, constant flow approach in which the propellant tank and transfer lines are only chilled once. The receiver tank is continuously vented as cryogenic liquid chills the transfer lines, tank mass and ullage space. Once chilled sufficiently, the receiver tank valve is closed and the tank is completely filled. Interestingly, the vent valve can be closed prior to receiver tank components reaching liquid saturation temperature. An incomplete fill results if insufficient energy is removed from the tank's thermal mass and ullage space. The key to successfully conducting the no vent fill is to assure that sufficient energy is removed from the system prior to closing the receiver tank vent valve. This paper will provide a description of the transfer methodology and test article, and will provide a discussion of test results.

Rhys, Noah O.↗