At least 55 records · Page 3

SU-FF-T-668: A Simple Algorithm for Range Modulation Wheel Design in Proton Therapy

Purpose: To develop a simple algorithm in designing the range modulation wheel to generate a very smooth Spread-Out Bragg peak (SOBP) for proton therapy.Method and Materials: A simple algorithm has been developed to generate the weight factors in corresponding pristine Bragg peaks which composed a smooth SOBP in proton therapy. We used a modified analytical Bragg peak function based on Monte Carol simulation tool-kits of Geant4 as pristine Bragg peaks input in our algorithm. A simple METLAB(R) Quad Program was introduced to optimize the cost function in our algorithm. Results: We found out that the existed analytical function of Bragg peak can't directly use as pristine Bragg peak dose-depth profile input file in optimization of the weight factors since this model didn't take into account of the scattering factors introducing from the range shifts in modifying the proton beam energies. We have done Geant4 simulations for proton energy of 63.4 MeV with a 1.08 cm SOBP for variation of pristine Bragg peaks which composed this SOBP and modified the existed analytical Bragg peak functions for their peak heights, ranges of R{sub 0}, and Gaussian energies {sigma}{sub E}. We found out that 19 pristine Bragg peaks are enough to achieve a flatness of 1.5% of SOBP which is the best flatness in the publications. Conclusion: This work develops a simple algorithm to generate the weight factors which is used to design a range modulation wheel to generate a smooth SOBP in protonradiation therapy. We have found out that a medium number of pristine Bragg peaks are enough to generate a SOBP with flatness less than 2%. It is potential to generate data base to store in the treatment plan to produce a clinic acceptable SOBP by using our simple algorithm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-204-01: A Methodology Based On Machine Learning and Quantum Clustering to Predict Lung SBRT Dosimetric Endpoints From Patient Specific Anatomic Features

Purpose: To develop a data-mining methodology based on quantum clustering and machine learning to predict expected dosimetric endpoints for lung SBRT applications based on patient-specific anatomic features. Methods: Ninety-three patients who received lung SBRT at our clinic from 2011–2013 were retrospectively identified. Planning information was acquired for each patient, from which various features were extracted using in-house semi-automatic software. Anatomic features included tumor-to-OAR distances, tumor location, total-lung-volume, GTV and ITV. Dosimetric endpoints were adopted from RTOG-0195 recommendations, and consisted of various OAR-specific partial-volume doses and maximum point-doses. First, PCA analysis and unsupervised quantum-clustering was used to explore the feature-space to identify potentially strong classifiers. Secondly, a multi-class logistic regression algorithm was developed and trained to predict dose-volume endpoints based on patient-specific anatomic features. Classes were defined by discretizing the dose-volume data, and the feature-space was zero-mean normalized. Fitting parameters were determined by minimizing a regularized cost function, and optimization was performed via gradient descent. As a pilot study, the model was tested on two esophageal dosimetric planning endpoints (maximum point-dose, dose-to-5cc), and its generalizability was evaluated with leave-one-out cross-validation. Results: Quantum-Clustering demonstrated a strong separation of feature-space at 15Gy across the first-and-second Principle Components of the data when the dosimetric endpoints were retrospectively identified. Maximum point dose prediction to the esophagus demonstrated a cross-validation accuracy of 87%, and the maximum dose to 5cc demonstrated a respective value of 79%. The largest optimized weighting factor was placed on GTV-to-esophagus distance (a factor of 10 greater than the second largest weighting factor), indicating an intuitively strong correlation between this feature and both endpoints. Conclusion: This pilot study shows that it is feasible to predict dose-volume endpoints based on patient-specific anatomic features. The developed methodology can potentially help to identify patients at risk for higher OAR doses, thus improving the efficiency of treatment planning. R01-184173.

60 APPLIED LIFE SCIENCES↗

Photon Organ and Effective Dose Coefficients for Cranial and Caudal Irradiation Geometries - Paper 148

With the introduction of new recommendations of the ICRP in Publication 103 the methodology for determining the protection quantity effective dose has been modified. The modifications include changes in organ/tissue weighting factors as well as some changes in radiation weighting factors. Computations of protection dose coefficients now require the use of reference male and female voxel phantoms, see ICRP Publication 110. Computations of equivalent doses in organs and tissues are now performed in each phantom and the average is used to compute the effective dose. The latest set of external dose coefficients using the new reference phantoms and the latest guidance from the ICRP were performed by the ICRP DOCAL task group and reported in ICRP Publication 116, the revision of ICRP Publication 74 and ICRU Report 57. The coefficients were determined for the following irradiation geometries: anterior-posterior (AP), posterior-anterior (PA), right and left lateral (RLAT and LLAT), rotational (ROT), and isotropic (ISO). For all geometries, except the ISO geometry, parallel beams are used to compute the dose coefficients. In this paper, the methodology of ICRP Publication 116 was used to compute dose coefficients for photons for irradiations of the body with parallel beams directed upward from below the feet (caudal) and directed downward from above the head (cranial). These geometries may be encountered in the workplace for personnel standing on contaminated surfaces or volumes and from overhead sources. In this work calculations of organ and tissue kerma and absorbed doses for caudal and cranial exposures to photons ranging in energy from 10 keV to 10 GeV have been performed using the MCNP6.1 radiation transport code and the adult reference phantoms of ICRP Publication 110. Dose coefficients for caudal and cranial irradiation geometries have been calculated in accordance with ICRP Publication 103. The coefficients differ significantly from AP values for both organ and tissues of ICRP Publication 116, as would be expected. For workers in these scenarios organ and effective doses can differ significantly from AP values. For common photon energies (i.e. 100 keV to a few MeV) the AP effective dose overestimates the caudal and cranial values by about a factor of ten. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Patient-specific radiation dose and cancer risk estimation in CT: Part II. Application to patients

Purpose: Current methods for estimating and reporting radiation dose from CT examinations are largely patient-generic; the body size and hence dose variation from patient to patient is not reflected. Furthermore, the current protocol designs rely on dose as a surrogate for the risk of cancer incidence, neglecting the strong dependence of risk on age and gender. The purpose of this study was to develop a method for estimating patient-specific radiation dose and cancer risk from CT examinations. Methods: The study included two patients (a 5-week-old female patient and a 12-year-old male patient), who underwent 64-slice CT examinations (LightSpeed VCT, GE Healthcare) of the chest, abdomen, and pelvis at our institution in 2006. For each patient, a nonuniform rational B-spine (NURBS) based full-body computer model was created based on the patient's clinical CT data. Large organs and structures inside the image volume were individually segmented and modeled. Other organs were created by transforming an existing adult male or female full-body computer model (developed from visible human data) to match the framework defined by the segmented organs, referencing the organ volume and anthropometry data in ICRP Publication 89. A Monte Carlo program previously developed and validated for dose simulation on the LightSpeed VCT scanner was used to estimate patient-specific organ dose, from which effective dose and risks of cancer incidence were derived. Patient-specific organ dose and effective dose were compared with patient-generic CT dose quantities in current clinical use: the volume-weighted CT dose index (CTDI{sub vol}) and the effective dose derived from the dose-length product (DLP). Results: The effective dose for the CT examination of the newborn patient (5.7 mSv) was higher but comparable to that for the CT examination of the teenager patient (4.9 mSv) due to the size-based clinical CT protocols at our institution, which employ lower scan techniques for smaller patients. However, the overall risk of cancer incidence attributable to the CT examination was much higher for the newborn (2.4 in 1000) than for the teenager (0.7 in 1000). For the two pediatric-aged patients in our study, CTDI{sub vol} underestimated dose to large organs in the scan coverage by 30%-48%. The effective dose derived from DLP using published conversion coefficients differed from that calculated using patient-specific organ dose values by -57% to 13%, when the tissue weighting factors of ICRP 60 were used, and by -63% to 28%, when the tissue weighting factors of ICRP 103 were used. Conclusions: It is possible to estimate patient-specific radiation dose and cancer risk from CT examinations by combining a validated Monte Carlo program with patient-specific anatomical models that are derived from the patients' clinical CT data and supplemented by transformed models of reference adults. With the construction of a large library of patient-specific computer models encompassing patients of all ages and weight percentiles, dose and risk can be estimated for any patient prior to or after a CT examination. Such information may aid in decisions for image utilization and can further guide the design and optimization of CT technologies and scan protocols.

60 APPLIED LIFE SCIENCES↗

MIRD Commentary: Proposed Name for a Dosimetry Unit Applicable to Deterministic Biological Effects-The Barendsen (Bd)

The fundamental physical quantity for relating all biologic effects to radiation exposure is the absorbed dose, the energy imparted per unit mass of tissue. Absorbed dose is expressed in units of joules per kilogram (J/kg) and is given the special name gray (Gy). Exposure to ionizing radiation may cause both deterministic and stochastic biologic effects. To account for the relative effect per unit absorbed dose that has been observed for different types of radiation, the International Commission on Radiological Protection (ICRP) has established radiation weighting factors for stochastic effects. The product of absorbed dose in Gy and the radiation weighting factor is defined as the equivalent dose. Equivalent dose values are designated by a special named unit, the sievert (Sv). Unlike the situation for stochastic effects, no well-defined formalism and associated special named quantities have been widely adopted for deterministic effects. The therapeutic application of radionuclides and, specifically, -particle emitters in nuclear medicine has brought to the forefront the need for a well-defined dosimetry formalism applicable to deterministic effects that is accompanied by corresponding special named quantities. This commentary reviews recent proposals related to this issue and concludes with a recommendation to establish a new named quantity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-G-JeP4-02: An Investigation of Respiratory Surrogate Motion Data Requirements for Multiple-Step Ahead Prediction

Purpose: Respiratory-gated radiotherapy and dynamic tracking employ real-time imaging and surrogate motion-monitoring methods with tumor motion prediction in advance of real-time. This study investigated respiratory motion data length on prediction accuracy of tumor motion. Methods: Predictions generated from the algorithm are validated against a one-dimensional surrogate signal of amplitude versus time. Prediction consists of three major components: extracting top-ranked subcomponents from training data matching the last respiratory cycle; calculating weighting factors from best-matched subcomponents; fusing data proceeding best-matched subcomponents with respective weighting factors to form predictions. Predictions for one respiratory cycle (∼3-6seconds) were assessed using 351 patient data from the respiratory management device. Performance was evaluated for correlation coefficient and root mean square error (RMSE) between prediction and final respiratory cycle. Results: Respiratory prediction results fell into two classes, where best predictions for 70 cycles or less performed using relative prediction and greater than 70 cycles are predicted similarly using relative and derivative relative. For 70 respiratory cycles or less, the average correlation between prediction and final respiratory cycle was 0.9999±0.0001, 0.9999±0.0001, 0.9988±0.0003, 0.9985±0.0023, and 0.9981±0.0023 with RMSE values of 0.0091±0.0030, 0.0091±0.0030, 0.0305±0.0051, 0.0299±0.0259, and 0.0299±0.0259 for equal, relative, pattern, derivative equal and derivative relative weighting methods, respectively. Respectively, the total best prediction for each method was 37, 65, 20, 22, and 22. For data with greater than 70 cycles average correlation was 0.9999±0.0001, 0.9999±0.0001, 0.9988±0.0004, 0.9988±0.0020, and 0.9988±0.0020 with RMSE values of 0.0081±0.0031, 0.0082±0.0033, 0.0306±0.0056, 0.0218±0.0222, and 0.0218±0.0222 for equal, relative, pattern, derivative equal and derivative relative weighting methods, respectively. Respectively, the total best prediction for each method was 24, 44, 42, 30, and 45. Conclusion: The prediction algorithms are effective in estimating surrogate motion in advance. These results indicate an advantage in using relative prediction for shorter data and either relative or derivative relative prediction for longer data.

60 APPLIED LIFE SCIENCES↗

Reweighting towards the chiral limit

We propose to perform fully dynamical simulations at small quark masses by reweighting in the quark mass. This approach avoids some of the technical difficulties associated with direct simulations at very small quark masses. We calculate the weight factors stochastically, using determinant breakup and low mode projection to reduce the statistical fluctuations. We find that the weight factors fluctuate only moderately on nHYP smeared dynamical Wilson-clover ensembles, and we could successfully reweight 16{sup 4}, (1.85 fm){sup 4} volume configurations from m{sub q}{approx_equal}20 MeV to m{sub q}{approx_equal}5 MeV quark masses, reaching the {epsilon}-regime. We illustrate the strength of the method by calculating the low energy constant F from the {epsilon}-regime pseudoscalar correlator.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-C-BRF-07: A Pattern Fusion Algorithm for Multi-Step Ahead Prediction of Surrogate Motion

Purpose: To assure that tumor motion is within the radiation field during high-dose and high-precision radiosurgery, real-time imaging and surrogate monitoring are employed. These methods are useful in providing real-time tumor/surrogate motion but no future information is available. In order to anticipate future tumor/surrogate motion and track target location precisely, an algorithm is developed and investigated for estimating surrogate motion multiple-steps ahead. Methods: The study utilized a one-dimensional surrogate motion signal divided into three components: (a) training component containing the primary data including the first frame to the beginning of the input subsequence; (b) input subsequence component of the surrogate signal used as input to the prediction algorithm: (c) output subsequence component is the remaining signal used as the known output of the prediction algorithm for validation. The prediction algorithm consists of three major steps: (1) extracting subsequences from training component which best-match the input subsequence according to given criterion; (2) calculating weighting factors from these best-matched subsequence; (3) collecting the proceeding parts of the subsequences and combining them together with assigned weighting factors to form output. The prediction algorithm was examined for several patients, and its performance is assessed based on the correlation between prediction and known output. Results: Respiratory motion data was collected for 20 patients using the RPM system. The output subsequence is the last 50 samples (∼2 seconds) of a surrogate signal, and the input subsequence was 100 (∼3 seconds) frames prior to the output subsequence. Based on the analysis of correlation coefficient between predicted and known output subsequence, the average correlation is 0.9644±0.0394 and 0.9789±0.0239 for equal-weighting and relative-weighting strategies, respectively. Conclusion: Preliminary results indicate that the prediction algorithm is effective in estimating surrogate motion multiple-steps in advance. Relative-weighting method shows better prediction accuracy than equal-weighting method. More parameters of this algorithm are under investigation.

60 APPLIED LIFE SCIENCES↗

Radiation Doses to Members of the U.S. Population from Ubiquitous Radionuclides in the Body: Part 2, Methods and Dose Calculations

This paper is part two of a three-part series investigating annual effective doses to residents of the United States from intakes of ubiquitous radionuclides, including radionuclides occurring naturally, radionuclides whose concentrations are technologically enhanced, and anthropogenic radionuclides. This series of papers explicitly excludes intakes from inhaling 222Rn, 220Rn, and their short-lived decay products; it also excludes intakes of radionuclides in occupational and medical settings. Part one reviewed, summarized, characterized, and grouped all published and some unpublished data for U.S. residents on ubiquitous radionuclide concentrations in tissues and organs. Assumptions about equilibrium with long-lived parents are made for the 28 other radionuclides in these series lacking data. This paper describes the methods developed to group the collected data into source regions described in the Radiation Dose Assessment Resource (RADAR) dosimetric methodology. Methods for converting the various units of data published over 50 years into a standard form are developed and described. Often, meaningful values of uncertainty of measurements were not published so that variability in data sets is confounded with measurement uncertainty. A description of the methods developed to estimate variability is included in this paper. The data described in part one are grouped by gender and age to match the RADAR dosimetric phantoms. Within these phantoms, concentration values are grouped into source tissue regions by radionuclide, and they are imputed for source regions lacking tissue data. Radionuclide concentrations are then imputed for other phantoms’ source regions with missing concentration values, and the uncertainties of the imputed values are increased. The content concentrations of hollow organs are calculated, and activities are apportioned to the bone source regions using assumptions about each radionuclide’s bone-seeking behavior. The data sets are then ready to be used to estimate equivalent doses to target tissues from these source regions. The target tissues are then mapped to lists of tissues with International Commission on Radiation Protection (ICRP) tissue weighting factors, or they are mapped to surrogate tissue regions when there is no direct match. Effective doses, using ICRP tissue weighting factors recommended in 1977, 1990, and 2007, are calculated from tissue and organ equivalent doses.

59 BASIC BIOLOGICAL SCIENCES↗

Task-based weights for photon counting spectral x-ray imaging

Purpose: To develop a framework for taking the spatial frequency composition of an imaging task into account when determining optimal bin weight factors for photon counting energy sensitive x-ray systems. A second purpose of the investigation is to evaluate the possible improvement compared to using pixel based weights. Methods: The Fourier based approach of imaging performance and detectability index d' is applied to pulse height discriminating photon counting systems. The dependency of d' on the bin weight factors is made explicit, taking into account both differences in signal and noise transfer characteristics across bins and the spatial frequency dependency of interbin correlations from reabsorbed scatter. Using a simplified model of a specific silicon detector, d' values for a high and a low frequency imaging task are determined for optimal weights and compared to pixel based weights. Results: The method successfully identifies bins where a large point spread function degrades detection of high spatial frequency targets. The method is also successful in determining how to downweigh highly correlated bins. Quantitative predictions for the simplified silicon detector model indicate that improvements in the detectability index when applying task-based weights instead of pixel based weights are small for high frequency targets, but could be in excess of 10% for low frequency tasks where scatter-induced correlation otherwise degrade detectability. Conclusions: The proposed method makes the spatial frequency dependency of complex correlation structures between bins and their effect on the system detective quantum efficiency easier to analyze and allows optimizing bin weights for given imaging tasks. A potential increase in detectability of double digit percents in silicon detector systems operated at typical CT energies (100 kVp) merits further evaluation on a real system. The method is noted to be of higher relevance for silicon detectors than for cadmium (zink) telluride detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vibrational nonequilibrium effects on diatomic dissociation rates

The collision-induced dissociation rate of diatomic molecules from a ladder of rotational and anharmonic vibrational states is developed, and the correction for vibrational nonequilibrium is considered. The result is similar to an analytic correction derived by Hammerling et al. (1959) for harmonic oscillators. An empirical correction algorithm suggested by Park (1987, 1990) gives similar results when vibrational temperature is comparable to kinetic temperature but underestimates the dissociation rate when vibrational temperature is small compared with the kinetic temperature. This algorithm uses an effective temperature in the experimentally determined Arrhenius expression for the rate coefficient, which is a weighted average of the vibrational and kinetic temperature, whereas theory indicates that kinetic temperature should appear only in the exponential term of the Arrhenius expression. Nevertheless, an effective temperature can always be found that will numerically duplicate the proper rate coefficient at any given condition, but a constant weighting factor cannot be expected to provide this. However, the algorithm can he adjusted to give reasonable results over a range of conditions if the geometric weighting factor is taken to be a simple linear function of the ratio of vibrational to kinetic temperature in the gas.

Hansen, C. F.↗

TURBULENCE-INDUCED RELATIVE VELOCITY OF DUST PARTICLES. IV. THE COLLISION KERNEL

Motivated by its importance for modeling dust particle growth in protoplanetary disks, we study turbulence-induced collision statistics of inertial particles as a function of the particle friction time, τ{sub p}. We show that turbulent clustering significantly enhances the collision rate for particles of similar sizes with τ{sub p} corresponding to the inertial range of the flow. If the friction time, τ{sub p,} {sub h}, of the larger particle is in the inertial range, the collision kernel per unit cross section increases with increasing friction time, τ{sub p,} {sub l}, of the smaller particle and reaches the maximum at τ{sub p,} {sub l} = τ{sub p,} {sub h}, where the clustering effect peaks. This feature is not captured by the commonly used kernel formula, which neglects the effect of clustering. We argue that turbulent clustering helps alleviate the bouncing barrier problem for planetesimal formation. We also investigate the collision velocity statistics using a collision-rate weighting factor to account for higher collision frequency for particle pairs with larger relative velocity. For τ{sub p,} {sub h} in the inertial range, the rms relative velocity with collision-rate weighting is found to be invariant with τ{sub p,} {sub l} and scales with τ{sub p,} {sub h} roughly as ∝ τ{sub p,h}{sup 1/2}. The weighting factor favors collisions with larger relative velocity, and including it leads to more destructive and less sticking collisions. We compare two collision kernel formulations based on spherical and cylindrical geometries. The two formulations give consistent results for the collision rate and the collision-rate weighted statistics, except that the spherical formulation predicts more head-on collisions than the cylindrical formulation.

79 ASTRONOMY AND ASTROPHYSICS↗

An adaptive grid/Navier-Stokes methodology for the calculation of nozzle afterbody base flows with a supersonic freestream

This paper describes an adaptive grid method for base flows in a supersonic freestream. The method is based on the direct finite-difference statement of the equidistribution principle. The weighting factor is a combination of the Mach number, density, and velocity first-derivative gradients in the radial direction. Two key ideas of the method are to smooth the weighting factor by using a type of implicit smoothing and to allow boundary points to move in the grid adaptation process. An AGARD nozzle afterbody base flow configuration is used to demonstrate the performance of the adaptive grid methodology. Computed base pressures are compared to experimental data. The adapted grid solutions offer a dramatic improvement in base pressure prediction compared to solutions computed on a nonadapted grid. A total-variation-diminishing (TVD) Navier-Stokes scheme is used to solve the governing flow equations.

Williams, Morgan↗

FGR 13 Dose Conversion Factor Files

The purpose of this document is to discuss the construction of two MACCS dose conversion factor (DCF) files in some detail, an older file created in 2007 named FGR13DCF.inp and a newer file created in 2018 called FGR13GyEquiv_RevA.inp. Very briefly, the difference between the two files is that the older file follows the standard conventions of assigning a radiation weighting factor of 20 for alpha radiation for all tissues and organs; whereas, the newer file complies with the FGR 13 health effects modeling and uses modified radiation weighting factors (referred to as relative biological effectiveness (RBE) factors) for alpha radiation of 10 for breast and of 1 for red bone marrow. During an intermediate period the creation of these two DCF files, a file called FGR13GyEquiv was created and used for the SOARCA calculations. This file was not released to the MACCS user community, but it is also discussed briefly in this document. DCF files are used by MACCS to convert air and ground radionuclide concentrations to doses to an organ or to the whole body. The MACCS calculation considers duration and shielding factor for each exposure pathway including cloudshine, groundshine, inhalation, and ingestion. Dose coefficients for cloudshine and groundshine are expressed as dose rates; dose coefficients for inhalation and ingestion are expressed as committed doses. In this document, dose coefficients (newer ICRP terminology) is used to describe the values contained in dose conversion factor (older ICRP terminology) files.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

FGR 13 Dose Conversion Factor Files

The purpose of this document is to discuss the construction of two MELCOR Accident Consequence Code System (MACCS) dose conversion factor (DCF) files in some detail, an older file created in 2007 named FGR13DCF.inp and a newer file created in 2018 called FGR13GyEquiv_RevAinp. Very briefly, the difference between the two files is that the older file follows the standard conventions of assigning a radiation weighting factor of 20 for alpha radiation for all tissues and organs; whereas, the newer file complies with the Federal Guidance Report (FGR) 13 health effects modeling and uses modified radiation weighting factors (referred to as relative biological effectiveness (RBE) factors) for alpha radiation of 10 for breast and of 1 for red bone marrow. During an intermediate period, a file called FGR13GyEquiv.inp was created and used for the State-of-the-Art Reactor Consequence Analysis (SOARCA) calculations. This file was not released to the MACCS user community, but it is also discussed briefly in this document.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Optimal inputs for system identification

Identification criteria are presented for linear dynamic systems with and without process noise. With process noise, the state equations are replaced by the Kalman filter equations. If the identification performance index is expanded in a Taylor's series with respect to the parameters to be identified, then maximizing the weighting factor of the quadratic term with respect to the inputs will insure that an identification algorithm will converge more rapidly and to a more accurate result than with nonoptimal inputs. The expectation of this weighting factor is the Fisher information matrix, and its inverse is a lower bound for the covariance of the parameters. Direct and indirect methods of calculating the information matrix are presented for systems with and without process noise.

Reid, D. B.↗

An Improved Weighted Least Squares Algorithm for the Analysis of Strain-Gage Balance Calibration Data

An improved version of an algorithm is presented that uses a weighted least squares fit of balance calibration data for the generation of the balance load prediction equations. The weighted least squares fit assigns a weighting factor between zero and one to each calibration data point that depends on a simple count of the number of intentionally loaded balance gages. The greater the number of the loaded gages is, the smaller a data point's weighting factor becomes. This strategy has two advantages. First, single-component loads become more influential during the regression analysis of the calibration data. In addition, the negative influence of load schedule asymmetries on the regression analysis results can more effectively be controlled. The original algorithm of 2017 was improved in 2020. Now, gage output differences relative to the natural zeros are exclusively used as input for the determination of the number of intentionally loaded gages. The improved weighted least squares fit can be applied with both the Non-Iterative Method and the Iterative Method that are used for the balance load prediction in the aerospace testing community. Machine calibration data of a force balance is used to illustrate benefits of the application of the improved weighted least squares fit of balance calibration data.

strain-gage balance↗

Technical Note: Relation between dual-energy subtraction of CT images for electron density calibration and virtual monochromatic imaging

Purpose: For accurate tissue inhomogeneity correction in radiotherapy treatment planning, the author previously proposed a simple conversion of the energy-subtracted computed tomography (CT) number to an electron density (ΔHU–ρ{sub e} conversion), which provides a single linear relationship between ΔHU and ρ{sub e} over a wide ρ{sub e} range. The purpose of the present study was to reveal the relation between the ΔHU image for ρ{sub e} calibration and a virtually monochromatic CT image by performing numerical analyses based on the basis material decomposition in dual-energy CT. Methods: The author determined the weighting factor, α{sub 0}, of the ΔHU–ρ{sub e} conversion through numerical analyses of the International Commission on Radiation Units and Measurements Report-46 human body tissues using their attenuation coefficients and given ρ{sub e} values. Another weighting factor, α(E), for synthesizing a virtual monochromatic CT image from high- and low-kV CT images, was also calculated in the energy range of 0.03 < E < 5 MeV, assuming that cortical bone and water were the basis materials. The mass attenuation coefficients for these materials were obtained using the XCOM photon cross sections database. The effective x-ray energies used to calculate the attenuation were chosen to imitate a dual-source CT scanner operated at 80–140 and 100–140 kV/Sn. Results: The determined α{sub 0} values were 0.455 for 80–140 kV/Sn and 0.743 for 100–140 kV/Sn. These values coincided almost perfectly with the respective maximal points of the calculated α(E) curves located at approximately 1 MeV, in which the photon-matter interaction in human body tissues is exclusively the incoherent (Compton) scattering. Conclusions: The ΔHU image could be regarded substantially as a CT image acquired with monoenergetic 1-MeV photons, which provides a linear relationship between CT numbers and electron densities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗