Search NASA⌕ Search

SEARCH · Search NASA

Results for “WINDOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

PVwindow (Photovoltaic Window Simulator) [SWR-22-01]

PVwindow simulates photovoltaic window properties by allowing the user build stacks of thin film materials that compose the window layers. The only needed inputs are the complex refractive indices and thicknesses of the materials. The software will simulate the optical transmission, front reflection, and back reflection of the stack using the transfer matrix method. Properties specific to PV window optics such as visible transmittance and color are also calculated. The optics code extracts the number of absorbed photons in the PV absorber layer and solves the single diode equation to yield theoretical photovoltaic metrics such as power conversion efficiency, fill factor, open circuit voltage, and short circuit current of the PV window when illuminated at an arbitrary angle or from either side of the stack. The software tool ultimately allows researchers to design photovoltaic windows and simulate their properties. The software also exports files that can be read into LBL Window software or into the EnergyPlus and Open Studio building energy modeling software to determine larger scale energy impacts of PV window integration.

Wheeler, Lance↗

Transforming Windows from Energy Liabilities to Zero-Energy Assets: Next-Generation Solutions for Buildings

Windows have traditionally contributed to a building's HVAC load, but they can also become a source of net energy gain or even operate as zero-energy components. For heating applications, highly insulating windows can harness more solar heat than the energy lost through them, transforming windows from energy liabilities to assets. Dynamic glazings provide further benefits by regulating solar heat gain, reducing cooling loads in summer and heating demands in winter. This simulation study focuses on developing the next generation of zero-energy windows (ZEW) for residential new construction. Through annual energy simulations across climate zones 1-8, ZEW performance benchmarks were established based on current code-level buildings, and we've identified the regions where meeting ZEW standards are most achievable. This work evaluates both static and dynamic window technologies, assessing their effects on annual energy use and cost. Key findings demonstrate that ZEW performance is achievable across diverse climate zones, with specific regional requirements. Most climate zones from 3-8 can achieve ZEW with specific configurations, while some warm climates (1-2) appear challenging for ZEW implementation. Climate zones 4-6 consistently allow for zero energy window implementation, offering multiple pathways through either static or dynamic window technologies. Colder climate zones (7-8) ZEW products allow for higher SHGC values while requiring low U-values.

Yu, Lili↗

Development of window scheduler algorithm exploiting natural ventilation and thermal mass for building energy simulation and smart home controls

Building energy simulations often rely on abstract assumptions when it comes to natural ventilation, such as ‘windows always open [or closed]’ or ‘windows open when outdoor temperature is below a certain threshold.’ However, simulations based on these assumptions fail to fully exploit the cooling potential of natural ventilation, as its effectiveness can be enhanced or diminished by various factors, including the presence of thermal mass. This issue also extends to smart home controls, where determining the window schedule becomes challenging without information about the building's response to outdoor conditions. To address these issues, this study has developed an analytical model for window operation schedules that leverages the passive cooling from natural ventilation. The analytical model was validated against a Modelica simulation. A case study utilizing the BESTEST model of ANSI/ASHRAE Standard 140 underwent validation with EnergyPlus simulations, showing strong concordance. The algorithm provides window schedule recommendations adapted to various airflow rates, thermal masses, and climate variations. Notably, the case study demonstrated that proper window scheduling could reduce indoor temperature by up to 8 °C under the given simulation settings, thereby improving resilience and indicating potential energy savings. Furthermore, the paper explores the potential opportunities and challenges this approach presents, especially for building simulation and smart home applications.

42 ENGINEERING↗

Pathway to Zero Energy Windows: Advancing Technologies and Market Adoption

Improving the performance of windows has the potential to reduce U.S. annual energy use by 1.7% and CO2 emissions by 1.9% in 2050. Beyond static windows, dynamic technologies could reduce U.S. annual energy use by 1.6 quads and CO2 emissions by 68 million metric tons. In addition, the widespread adoption of static and dynamic technologies would substantially reduce peak electricity demand from buildings. Beyond energy use and CO2 emissions reductions, improving window performance will increase occupant comfort and well-being. In a new report, Pathway to Zero Energy Windows: Advancing Technologies and Market Adoption, the U.S. Department of Energy (DOE) outlines multiple avenues for technology development, deployment, and adoption to increase the impact that windows can have on decarbonizing America's buildings.

building energy efficiency↗

Si–Cl 2 –Ar + Atomic Layer Etching Window: A Fundamental Study Using Molecular Dynamics Simulations and a Reduced Order Model

Silicon (Si) atomic layer etching (ALE) by alternating exposure to chlorine gas (Cl 2 ) and argon ions (Ar + ) is studied by using molecular dynamics (MD) simulations and a reduced order model (ROM). Here, the purpose of this study is to elucidate the properties of the ALE window, a range of ion energies where the amount of Si etched over a series of cycles is nonzero and nearly independent of ion energy. Experimental studies of the Si–Cl 2 –Ar + ALE system report contradictory results related to the ALE window’s ion energy range. Both MD simulations and the ROM show that there is an ALE window present from approximately 15 to 20 eV for normal incidence argon ions. The Si–Cl 2 –Ar + system, therefore, exhibits a narrow ALE window. The amount of Si etched per cycle is less than one atomic layer because of the higher etch yield of Cl atoms relative to atomic Si and silicon chlorides. A modified version of the ROM with an artificially increased Si physical sputtering threshold energy expands the ALE window, illustrating the importance of the difference in chemical and physical sputtering threshold energies in the ALE window energy range. The ROM is also used to examine the dependence of the EPC on the Ar + ion fluence.

energy↗

Polymer Inhibitors Enable >900 cm2 Dynamic Windows Based on Reversible Metal Electrodeposition with High Solar Modulation

Dynamic windows with adjustable tint give users control over the flow of light and heat to decrease the carbon footprint of buildings and improve the occupants’ comfort. Despite the benefits of dynamic windows, they are rarely deployed in buildings because the existing technology cannot achieve fast and colour-neutral tinting at an agreeable cost. Reversible metal electrodeposition is a promising approach to solve these problems. Here, we demonstrate the use of polymer inhibitors to reversibly deposit metal films with controlled morphology in dynamic windows. The windows that employ the polymer inhibitor can readily tint to below 0.001% visible transmittance in less than 3 min and exhibit high infrared reflectance (>70%), colour-neutral transmittance (C*<5) and an ultrawide range of optical and solar modulation (..delta..Tvis=0.76 and ..delta..SHGC=0.56). The polymer inhibitors also increase the efficiency and improve the durability of the windows and enable construction of >900 cm2 dynamic windows with fast response and excellent uniformity.

36 MATERIALS SCIENCE↗

Identification of a window for quiescent H-mode operation in MHD stability diagram of DIII-D plasmas

A window for quiescent H-mode (QH-mode) operation in DIII-D plasmas in the diagram of pedestal magnetohydrodynamic (MHD) stability was identified through linear MHD stability analysis, accounting for the effects of plasma rotation and ion diamagnetic drift. The operation window lies between the stability boundaries of the kink/peeling mode (K/PM) identified with and without the inclusion of plasma rotation effects. In this region, the mode remains unstable unless rotation effects are considered alongside the ion diamagnetic drift, which is consistently included in the analysis. The stabilization of the MHD mode, facilitated by the coupled effects of plasma rotation and ion diamagnetic drift, plays a crucial role in widening the window, enabling the attainment of the QH-mode state. Furthermore, the suppression of edge localized modes (ELM) can be achieved by controlling the pedestal structure to ensure the plasma state remains within the operation window. The location of the operation window in the stability diagram depends on the K/PM stability properties. Therefore, optimizing conditions for QH-mode requires adjustments based on changes in stability characteristics. A pressure pedestal and its associated bootstrap current density near the last closed flux surface are advantageous for situating the plasma state within the window. However, excessive current density can trigger ELMs. This trend was confirmed through comparisons of MHD stability diagrams between QH-mode and ELMy H-mode plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the impact of the galaxy window function on cosmological parameter estimation

One important source of systematics in galaxy redshift surveys comes from the estimation of the galaxy window function. Up until now, the impact of the uncertainty in estimating the galaxy window function on parameter inference has not been properly studied. In this paper, we show that the uncertainty and the bias in estimating the galaxy window function will be salient for ongoing and next-generation galaxy surveys using a simulation-based approach. With a specific case study of cross-correlating emission-line galaxies from the DESI Legacy Imaging Surveys and the Planck cosmic microwave background lensing map, we show that neural network-based regression approaches to modelling the window function are superior in comparison to linear regression-based models. Here, we additionally show that the definition of the galaxy overdensity estimator can impact the overall signal-to-noise of observed power spectra. Finally, we show that the additive biases coming from the window functions can significantly bias the modes of the inferred parameters and also degrade their precision. Thus, a careful understanding of the window functions will be essential to conduct cosmological experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

First Soft X-ray Quantum Efficiency Measurements on Microwave Annealed Thin-Entrance Window Sensors

Free electron lasers, such as SLAC’s LCLS-II, will provide unique scientific imaging opportunities. In order to fully utilize these facilities, we need to develop detectors with shallow entrance windows that will enable detection of soft x-rays from 250eV-1.5KeV. In addition, there are other light sources such as the FERMI, EuXFEL, and FLASH XFELs, as well as numerous synchrotrons such as the ALS, where soft x-ray science would benefit from detectors with higher quantum efficiency in the 20 eV to 1.5KeV range.A new microwave annealing technology provides an efficient way to achieve shallow entrance windows in fully depleted high-resistivity silicon sensors. Previously, SRP and SIMS measurements were used to characterize the shallow dopant profile, and sensors with the new entrance window process were deployed successfully to measure an Fe-55 x-ray spectrum. For the first time, we present quantum efficiency measurement for soft x-rays. Furthermore, the resulting estimate of the entrance window is 20nm for an arsenic implanted entrance window and 55nm for a boron implanted entrance window.

47 OTHER INSTRUMENTATION↗

Thin-Entrance Window Process for Soft X-Ray Sensors

New free electron lasers, such as SLAC’s LCLS-II, will provide unique scientific imaging opportunities. In order to fully utilize these facilities, we need to develop detectors with shallow entrance windows that will enable detection of soft x-rays from 250 eV to 1.5 KeV. Achieving adequately shallow entrance windows is challenging because the high temperature anneal needed to activate the dopant also drives the dopant profile deeper, growing the region that is insensitive to soft x-rays. A new microwave annealing technology provides an efficient way to achieve shallow entrance windows in fully depleted high-resistivity silicon sensors. The microwave anneal technique can activate dopants at low substrate temperature, with minimal dopant diffusion, and can be used to fabricate both n-type and p-type entrance windows. SRP and SIMS measurements were used to verify dopant activation with negligible dopant diffusion. We then applied the microwave anneal process to a planar sensor wafer, using the new process to create the backside diode contact. Electrical test of the resulting sensors shows good reverse bias characteristics. The sensors have been bump-bonded to a read-out ASIC and used successfully to measure an Fe-55 x-ray spectrum. Process and device simulations were performed to characterize the quantum efficiency of the entrance window for soft x-rays. This technique is useful for other sensor applications requiring a shallow entrance window, including detectors for UV photons, low energy ions and low energy electrons.

47 OTHER INSTRUMENTATION↗

Enhancing the dark-state bistability and thermal stability of zinc dynamic windows with nitrile electrolytes

Reversible metal electrodeposition (RME) for dynamic windows is a promising alternative to traditional electrochromics. We explore the reasons behind the bistability of practical RME dynamic windows under a wide temperature range, i.e., how well they maintain their dark state without external power. While Zn dynamic windows with dimethyl sulfoxide electrolytes exhibit adequate bistability at room temperature, their performance degrades at elevated temperatures due to the presence of small amounts of water. Here, to overcome this problem, we developed a set of Zn nitrile electrolytes. The integrated devices can maintain dark-state bistability over at least 1 month at 85°C with 0.1% transmission using a propionitrile (PrCN) electrolyte. Additionally, the PrCN-based Zn dynamic windows possess high optical contrast, color-neutral switching, and promising cyclability, making Zn RME in nitrile electrolytes a promising solution for achieving robust dynamic windows.

RME↗

An evaluation of the demand response potential of integrated dynamic window and HVAC systems

Demand response (DR) increases the flexibility and reliability of the electricity grid as use of intermittent renewable energy sources increases. HVAC and envelope DR measures present the largest aggregate energy and peak demand savings potential of all commercial building end uses because their net demand savings occur during critical peak demand periods. Controllable envelope measures include switchable electrochromic windows, operable window attachments such as outdoor louvers, roller shades, and awnings, as well as other innovative facade technologies that can modulate both solar heat gain and daylight admission over a broad solar-optical range. This study evaluated the technical potential of DR-enabled dynamic windows to reduce critical peak demand for a prototypical medium office building situated in all 16 U.S. climates. Model predictive control (MPC) algorithms were designed to minimize electricity cost in daylit perimeter office zones through control of an electrochromic window with and without HVAC thermostat setpoint control. Conventional and time-of-use rates were used to shape the degree of DR. Median annual peak demand savings with window and thermostat control across all climate zones were 24.3 kW (4.4 W/m 2 ) per building or 15.9 W/m 2 for non-north perimeter zones. Resource adequacy at the whole building level was estimated to be 13.1 to 43.4 $/kW per year over the 30-year life of the installation. Co-benefits were increased energy efficiency, and reduced electricity cost and emissions. Visual and thermal comfort requirements were met at all times. Dynamic facades controlled by MPC have substantial technical potential for DR across all U.S. climates and warrant serious consideration for inclusion in DR portfolios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Futures for electrochromic windows on high performance houses in arid, cold climates

This study investigates high performance electrochromic windows used on a passive house and residential dwelling to IECC 2021 (i.e., IECC dwelling). In the lab, the electrochromic film switches transmitted solar heat gain coefficient (SHGC) from 0.09 to 0.7 and visible transmittance from 0.15 to 0.82 with power consumption of 1.23 W/m 2 during switching times less than 3 minutes. We extrapolate these results to a window assembly. Building energy models of the houses were evaluated in Santa Fe, New Mexico. A Monte Carlo analysis for 2020, 2040, 2060, and 2080 was conducted for Shared Socioeconomic Pathways 2-4.5, 3-7.0, and 5-8.5. Cases with and without the electrochromic windows and with and without electricity were used to determine energy use intensity and hours beyond thermal safety thresholds. The passive house showed 1.3-3.1% mean energy savings and the IECC dwelling 4.4-5.1% with electrochromic efficiency benefits growing into the future for both cases. Even so, overall savings decrease into the future for the passive house, due to growth in cooling load being dominant, conversely overall energy savings increase into the future for the IECC dwelling due to heating loads being dominant. For thermal resilience, the passive house exhibited a mean percent decrease of 0.02-0.31% hours in the extreme caution (i.e., > 32.2 °C, ≤ 39.4 °C) range while the IECC dwelling exhibited 0.38-4.38%. The study therefore shows that electrochromic windows will have smaller benefits for the passive house in comparison to the IECC dwelling. The relationship between electrochromic windows is shown to have a complex relationship between house efficiency and climate change by these results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Oxygen K -edge X-ray absorption spectra of liquids with minimization of window contamination

We report oxygen K-edge X-ray absorption spectroscopy is used routinely to study a range of solid materials. However, liquid samples are studied less frequently at the oxygen K-edge due to the combined challenges of high-vacuum conditions and oxygen contamination of window materials. A modular sample holder design with a twist-seal sample containment system that provides a simple method to encapsulate liquid samples under high-vacuum conditions is presented. This work shows that pure silicon nitride windows have lower oxygen contamination than both diamond- and silicon-rich nitride windows, that the levels of oxygen contamination are related to the age of the windows, and provides a protocol for minimizing the background oxygen contamination. Acid-washed 100 nm-thick silicon nitride windows were found to give good quality oxygen K-edge data on dilute liquid samples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance of Windows in Walls With Continuous Insulation

Window openings in walls are a significant contributor to poor thermal performance because of thermal bridging through the framing members (e.g., studs, joists, plates, bracing) and because windows lack the thermal properties of insulation. This report, Performance of Windows in Walls with Continuous Insulation , explores the common method for installing windows in walls with continuous insulation and presents acceptance criteria for evaluating the performance of windows installed in walls with and without continuous insulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Comprehensive Analysis of Energy and Daylighting Impact of Window Shading Systems and Control Strategies on Commercial Buildings in the United States

Commercial buildings consume approximately 1.9 EJ of energy in the United States, 50% of which is for heating, cooling, and lighting applications. It is estimated that windows contribute up to 34% of the energy used for heating and cooling. However, window retrofits are not often undertaken to increase energy efficiency because of the high cost and disruptive nature of window installation. Highly efficient window technologies would also need shading devices for glare prevention and visual comfort. An automated window shading system with an appropriate control strategy is a technology that can reduce energy demand, maintain occupant comfort, and enhance the aesthetics and privacy of the built environment. However, the benefits of the automated shades currently used by the shading industry are not well studied. The topic merits an analysis that will help building owners, designers and engineers, and utilities make informed decisions using knowledge of the impact of this technology on energy consumption, peak demand, daylighting, and occupant comfort. This study uses integrated daylight and whole-building energy simulation to evaluate the performance of various control strategies that the shading industry uses in commercial office buildings. The analysis was performed for three different vintages of medium office buildings at six different locations in United States. The results obtained show the control strategies enabled cooling energy savings of up to 40% using exterior shading, and lighting energy savings of up to 25%. The control strategies described can help building engineers and researchers explore different control methods used to control shading in actual buildings but rarely discussed in the literature. This information will give researchers the opportunity to investigate potential improvements in current technologies and their performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Operating Hardware Impact on the Heat Transfer Properties of Windows

Despite significant advancements in fenestration technology in the last two decades, the thermal transmittance of fenestration products is still significantly higher than that of walls. This corresponds to 60% of the total energy loss of a modern building envelope through the windows. Hence, further development and improvements of fenestration products are necessary. Increasingly stringent codes and standards for fenestration stimulate industry to work on improved solutions. Thus, it is crucial that assessment techniques are able to account for innovations accurately. The thermal effects of non-continuous hardware in window frames are currently ignored by international rating procedures. A preliminary investigation conducted by our team showed significant performance degradation in two of the three out-opening casement profiles caused by the presence of operating hardware. Frames with the structure made of vinyl and fiberglass consist of many air cavities that are penetrated by operating hardware made of highly conductive materials. In these frames, in order to have an accurate assessment, it may be required to employ three-dimensional modeling due to the convective nature of heat transfer within the cavities. However, in this study, we demonstrate that the three-dimensional (3D) effects of non-continuous hardware can be approximated accurately with simpler two-dimensional (2D) simulations. We then develop a simplified model based on weighted average capable of replacing the time- and computation-intensive 3D simulations with 2D simulations and validate it against market available frames and their corresponding hardware. Validation results show that our approximation technique results in discrepancies lower than 0.05 W/(m2K), or 3% of the total thermal transmittance. Thus, we conclude that simplified 2D simulation models may be used for predicting hardware impact in window frames with reasonable accuracy. As windows and glazing structures are becoming ever better thermally insulated, it is becoming even more important to be able to model the impact of the operating hardware on the total thermal performance in order to design the best windows possible and not let the operating hardware ruin an otherwise well-proven design, which is hence addressed in this study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Timing Calibration and Windowing Technique Comparison for Lightning Mapping Arrays

Abstract Since their introduction 22 years ago, lightning mapping arrays (LMA) have played a central role in the investigation of lightning physics. Even in recent years with the proliferation of digital interferometers and the introduction of the LOw Frequency ARray (LOFAR) radio telescope, LMAs still play an important role in lightning science. LMA networks use a simple windowing technique that records the highest pulse in either 80 μs or 10 μs fixed windows in order to apply a time‐of‐arrival location technique. In this work, we develop an LMA‐emulator that uses lightning data recorded by LOFAR to simulate an LMA, and we use it to test three new styles of pulse windowing. We show that they produce very similar results as the more traditional LMA windowing, implying that LMA lightning mapping results are relatively independent of windowing technique. In addition, each LMA station has its GPS‐conditioned clock. While the timing accuracy of GPS receivers has improved significantly over the years, they still significantly limit the timing measurements of the LMA. Recently, new time‐of‐arrival techniques have been introduced that can be used to self‐calibrate systematic offsets between different receiving stations. Applying this calibration technique to a set of data with 32 ns uncertainty, observed by the Colorado LMA, improves the timing uncertainty to 19 ns. This technique is not limited to LMAs and could be used to help calibrate future multi‐station lightning interferometers.

Hare, Brian M.↗