Search NASA⌕ Search

SEARCH · Search NASA

Results for “Wastewater System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Emergence and disruption of cooperativity in a denitrifying microbial community

Anthropogenic perturbations to the nitrogen cycle, primarily through use of synthetic fertilizers, is driving an unprecedented increase in the emission of nitrous oxide (N 2 O), a potent greenhouse gas and an ozone depleting substance, causing urgency in identifying the sources and sinks of N 2 O. Microbial denitrification is a primary contributor to biotic production of N 2 O in anoxic regions of soil, marine systems, and wastewater treatment facilities. Here, through comprehensive genome analysis, we show that pathway partitioning is a ubiquitous mechanism of complete denitrification within microbial communities. We have investigated mechanisms and consequences of process partitioning of denitrification through detailed physiological characterization and kinetic modeling of a synthetic community of Rhodanobacter thiooxydans FW510-R12 and Acidovorax sp. GW101-3H11. We have discovered that these two bacterial isolates, from a heavily nitrate (NO 3 − ) contaminated superfund site, complete denitrification through the exchange of nitrite (NO 2 − ) and nitric oxide (NO). The process partitioning of denitrification and other processes, including amino acid metabolism, contribute to increased cooperativity within this denitrifying community. We demonstrate that certain contexts, such as high NO 3 − , cause unbalanced growth of community members, due to differences in their substrate utilization kinetics. The altered growth characteristics of community members drives accumulation of toxic NO 2 − , which disrupts denitrification causing N 2 O off gassing.

59 BASIC BIOLOGICAL SCIENCES↗

Valorizing Hydrothermal liquefaction aqueous phase via nanofiltration: Enhancing biocrude production from algal biomass

The hydrothermal liquefaction aqueous phase (HTL-AP), a nutrient- and carbon-rich waste byproduct of the HTL process, can be recirculated to enhance biocrude production efficiency. To avoid dilution of the HTL feedstock and reduced fuel quality associated with recirculating untreated HTL-AP, this study investigated nanofiltration to concentrate organic compounds and separate nutrients from HTL-AP of three algal biomass sources: an algal wastewater treatment system and two from harmful algal blooms in lakes. Up to 99% of the organics were recovered in the concentrated HTL-AP (retentate), and significant increases in both permeate flux and permeation of nitrogenous compounds were achieved by increasing HTL-AP temperature to 45 °C and pH to 11. Recirculating the concentrated HTL-AP increased biocrude yield by 70%-116% and reduced biocrude nitrogen content by up to 12%. The carbon and energy capture in the biocrude also increased by 66% and 68%, respectively.

09 BIOMASS FUELS↗

Structure–reactivity relationships in the removal efficiency of catechol and hydroquinone by structurally diverse Mn-oxides

Catechol and hydroquinone are widely present hydroxybenzene isomers in the natural environment that induce environmental toxicities. These hydroxybenzene compounds can be effectively removed by manganese (Mn)-oxides via sorption and oxidative degradation processes. In the present study, we investigated the structure–reactivity relationships in the sorption and oxidation of catechol and hydroquinone on Mn-oxide surfaces. Two widely present Mn-oxides, including hydrous Mn oxide (HMO) and cryptomelane, comprised of layer and tunnel structures, respectively, are specifically studied. Effects of Mn-oxide structures and environmental pH conditions on the removal efficiency of these hydroxybenzene compounds, via sorption and oxidative degradation, are investigated. Cryptomelane, which has a higher specific surface area than HMO, possesses a higher sorption and oxidation capacity. The complexation mechanisms of catechol and hydroquinone vary due to their structure-induced difference in reactivity. Catechol reduced and dissolved more Mn from Mn-oxides than hydroquinone, accompanied by a higher C loss of catechol-C, suggesting a higher reactivity of catechol. Structural changes occurred in the Mn-oxides resulting from reaction with catechol and hydroquinone: reduction of Mn(IV), corresponding formation of Mn(III) and Mn(II) in the mineral, and free Mn 2+ ions released into the suspension. Finally, these insights could help us better understand and predict the fate of hydroxybenzene compounds in Mn-oxide-rich soils and wastewater treatment systems that generate Mn-oxides via Mn removal and the associated environmental toxicity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A directional electrode separator improves anodic biofilm current density in a well-mixed single-chamber bioelectrochemical system

In this study, a directional electrode separator (DES) was designed and incorporated into a single-chamber bioelectrochemical system (BES) to reduce migration and reoxidation of hydrogen. This issue arises when H 2 , generated at the cathode, travels to the anode where anodic biofilms use H 2 . To test the feasibility of our design, a 3D-printed BES reactor equipped with a DES was inoculated with anaerobic digestor granules and operated under fed-batch conditions using fermented corn stover effluent. The DES equipped reactor achieved significantly higher current densities (~53 A/m²) compared to a conventional single-chamber BES without a separator (~16 A/m²), showing a 3.3 times improvement. Further, control abiotic electrochemical experiments revealed that the DES exhibited significantly higher proton conductivity (456±127 µS/mm) compared to a proton exchange membrane (67±21 µS/mm) with a statistical significance of P=0.03. The DES also effectively reduced H 2 migration to the anode by 21-fold relative to the control. Overall, incorporating a DES in a single-chamber BES enhanced anodic current density by reducing H 2 migration to the anode.

3D printed BES↗

Coupling extracellular glycan composition with metagenomic data in papermill and brewery anaerobic granular sludges

Glycans are crucial for the structure and function of anaerobic granular sludge in wastewater treatment. Yet, there is limited knowledge regarding the microorganisms and biosynthesis pathways responsible for glycan production. In this study, we analysed samples from anaerobic granular sludges treating papermill and brewery wastewater, examining glycans composition and using metagenome-assembled genomes (MAGs) to explore potential biochemical pathways associated with their production. Uronic acids were the predominant constituents of the glycans in extracellular polymeric substances (EPS) produced by the anaerobic granular sludges, comprising up to 60 % of the total polysaccharide content. MAGs affiliated with Anaerolineacae, Methanobacteriaceae and Methanosaetaceae represented the majority of the microbial community (30–50 % of total reads per MAG). Based on the analysis of MAGs, it appears that Anaerolinea sp. and members of the Methanobacteria class are involved in the production of exopolysaccharides within the analysed granular sludges. These findings shed light on the functional roles of microorganisms in glycan production in industrial anaerobic wastewater treatment systems.

59 BASIC BIOLOGICAL SCIENCES↗

A microbiological survey of handwashing sinks in the hospital built environment reveals differences in patient room and healthcare personnel sinks

Handwashing sinks and their associated premise plumbing are an ideal environment for pathogen-harboring biofilms to grow and spread throughout facilities due to the connected system of wastewater plumbing. This study was designed to understand the distribution of pathogens and antibiotic resistant organisms (ARO) within and among handwashing sinks in healthcare settings, using culture-dependent methods to quantify Pseudomonas aeruginosa, opportunistic pathogens capable of growth on a cefotaxime-containing medium (OPP-C), and carbapenem-resistant Enterobacteriaceae (CRE). Isolates from each medium identified as P. aeruginosa or Enterobacteriaceae were tested for susceptibility to aztreonam, ceftazidime, and meropenem; Enterobacteriaceae were also tested against ertapenem and cefotaxime. Isolates exhibiting resistance or intermediate resistance were designated ARO. Pathogens were quantified at different locations within handwashing sinks and compared in quantity and distribution between healthcare personnel (HCP) and patient room (PR) sinks. ARO were compared between samples within a sink (biofilm vs planktonic samples) and between sink types (HCP vs. PR). The drain cover was identified as a reservoir within multiple sinks that was often colonized by pathogens despite daily sink cleaning. P. aeruginosa and OPP-C mean log 10 CFU/cm 2 counts were higher in p-trap and tail pipe biofilm samples from HCP compared to PR sinks (2.77 ± 2.39 vs. 1.23 ± 1.62 and 5.27 ± 1.10 vs. 4.74 ± 1.06) for P. aeruginosa and OPP-C, respectively. P. aeruginosa and OPP-C mean log 10 CFU/ml counts were also higher (p < 0.05) in HCP compared to PR sinks p-trap water (2.21 ± 1.52 vs. 0.89 ± 1.44 and 3.87 ± 0.78 vs. 3.21 ± 1.11) for P. aeruginosa and OPP-C, respectively. However, a greater percentage of ARO were recovered from PR sinks compared to HCP sinks (p < 0.05) for Enterobacteriaceae (76.4 vs. 32.9%) and P. aeruginosa (25.6 vs. 0.3%). This study supports previous work citing that handwashing sinks are reservoirs for pathogens and ARO and identifies differences in pathogen and ARO quantities between HCP and PR sinks, despite the interconnected premise plumbing.

60 APPLIED LIFE SCIENCES↗

Organic wastewater treatment by a single-atom catalyst and electrolytically produced H2O2

The presence of organic contaminants in wastewater poses considerable risks to the health of both humans and ecosystems. Although advanced oxidation processes that rely on highly reactive radicals to destroy organic contaminants are appealing treatment options, substantial energy and chemical inputs limit their practical applications. Here we demonstrate that Cu single atoms incorporated in graphitic carbon nitride can catalytically activate H 2 O 2 to generate hydroxyl radicals at pH 7.0 without energy input, and show robust stability within a filtration device. We further design an electrolysis reactor for the on-site generation of H 2 O 2 from air, water and renewable energy. Coupling the single-atom catalytic filter and the H 2 O 2 electrolytic generator in tandem delivers a wastewater treatment system. These findings provide a promising path toward reducing the energy and chemical demands of advanced oxidation processes, as well as enabling their implementation in remote areas and isolated communities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancement of microbiome management by machine learning for biological wastewater treatment

Here we propose to develop microbiome-based machine learning models to predict the response of biological wastewater treatment systems to environmental or operational disturbances or to design specific microbiomes to achieve a desired system function. These machine learning models can be used to enhance the stability of microbiome-based biological systems and warn against the failure of these systems.

59 BASIC BIOLOGICAL SCIENCES↗

NEWTS Coal Mine Drainage Dataset from Cravotta Brady (2015)

Data from Cravotta, Brady, "Priority pollutants and associated constituents in untreated and treated discharges from coal mining or processing facilities in Pennsylvania, USA". Applied Geochemistry, 2015. https://doi.org/10.1016/j.apgeochem.2015.03.001 Dataset includes information on water quality composition including inorganic compounds from untreated and treated streams of coal-mine discharge from coal mining and coal processing locations. Data is provided in the original version as well as in a summarized version for easy input into aqueous chemistry modeling software.

Aqueous Chemistry↗

E-Tunnel wastewater discharge permit quarterly monitoring report. Water pollution control permit Nev 96021, third quarter 2020

Monitoring and sampling activities are performed at the E-Tunnel Wastewater Disposal System (ETDS ) in accordance with the requirements of Water Pollution Control (WPC) Permit NEV 96021, Revision 1, which is effective October 1, 2013. Although the end date of the WPC permit is September 30, 2018, the Nevada Division of Environmental Protection (NDEP), in a letter dated September 21, 2018, provided guidance that indicated the WPC Permit NEV 96021, Revision 1, is in effect until NDEP notifies the U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office otherwise. This QMR includes the results of monthly inspections and monitoring for July, August, and September 2020. Monthly inspections and monitoring were conducted on July 21, August 19, and September 16, 2020. Inspections include a visual assessment of the berms, ponding, water levels relative to the overflow pipes, tunneling or burrowing into the berms, soil conditions on and around the berms, erosion or sloughing of the slopes of the berms, seeps at the toe of the berms, deep-rooting botanicals on the berms, and fencing. Monthly monitoring includes measurement s of the instantaneous flow rate, hydrogen ion activity (pH), and specific conductance of the ETDS discharge. The report will be submitted to the State of Nevada.

54 ENVIRONMENTAL SCIENCES↗

E-Tunnel Wastewater Discharge Permit Quarterly Monitoring Report

Monitoring and sampling activities are performed at the E-Tunnel Wastewater Disposal System (ETDS) in accordance with the requirements of Water Pollution Control (WPC) Permit NEV 96021, Revision 1, which is effective October 1, 2013. Although the end date of the WPC permit is September 21, 2018, provided Nevada Division of Environmental Protection (NDEP), in a letter date September 21, 2018, provided guidance that indicated the WPC Permit NEV 96021, Revision 1, is in effect until NDEP notifies the U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office otherwise. This QMR includes the results of monthly inspections and monitoring for April, May, and June 2020. Monthly inspections and monitoring were conducted on April 21, May 28, and June 24 2020. Inspections include a visual assessment of the berms, ponding, water levels relative to the overflow pipes, tunneling or burrowing into the berms, seeps at the toe of the berms, deep-rooting botanicals on the berms, and fencing. Monthly monitoring includes measurements of the instantaneous flow rate, hydrogen ion activity (pH), and specific conductance of the ETDS discharge.

99 GENERAL AND MISCELLANEOUS↗

Potential Advantages to Employing an Onsite Laboratory at FUSRAP Sites Contaminated with Radionuclides and Metals - 20353

Various factors that support an evaluation of the relative costs, advantages and disadvantages of utilizing an onsite laboratory or an offsite laboratory for remediation of Formerly Utilized Sites Remedial Action Program (FUSRAP) sites contaminated with radionuclides and metals are presented. In terms of how much more quickly an onsite laboratory provides results versus an offsite laboratory, the results of this study provide tools for calculating the amount of cost savings per day for excavation of contaminated soils for various scenarios including: - State, municipal or local property remediation where the remediation schedule becomes time-critical due to the extra cost and inconvenience to the town or municipality caused by the need for increased security and safety personnel, possible road closures and detours, and the inconvenience to the public due to modified or decreased services of State or municipal facilities; - Residential property where the remediation schedule becomes time-critical due to the inconvenience to the homeowner as well as the importance of maintaining good community relations; - Commercial property where the remediation schedule becomes time-critical due to the hardship and potential loss of revenue endured by the property owner; - Open area where treatment of excavation water is required, and - Open area where treatment of excavation water is not required. For every scenario, the number of matrices, radionuclide and metal contaminants of concern and the project duration are important factors. The costs for the onsite laboratory included the capital costs associated with setting up the lab such as trailer(s) or building(s), power and water hookup, analytical testing equipment, balances, computers, desks and bookcases; support equipment such as hot plates, filtration assemblies, safety equipment, ovens, etc.; and supplies such as glassware, pipettes, filters, etc. and ongoing costs such as labor, chemicals and reagents, standards, cost of the laboratory obtaining certification and maintenance. Offsite laboratory sample testing costs are generally very competitive and typically substantially lower than onsite laboratory costs if only the sample testing costs are considered. The great disadvantage of using an offsite laboratory is that they often cannot guarantee rapid turnaround times for results which creates project delays associated with the remediation process including delays determining the completeness of the characterization and remediation processes, delays in backfilling a property and additional costs for treating wastewater (excavation water, stormwater or both). These costs will vary greatly depending upon the area of the country in which the project is located due to the wide range of labor costs for the onsite laboratory and field workers, as well as the contaminants of interest, matrices and most importantly the size of the impacted area and the number of properties located in that area. This paper provides guidelines for calculating the cost savings that may be realized if an onsite laboratory can generate results more quickly than an offsite laboratory by estimating the costs associated with the remediation process for the various scenarios noted above such as work crew labor costs, excavator and dump truck equipment rentals, wastewater treatment costs (if applicable) and the additional costs incurred by homeowners, commercial property owners and towns/municipalities that are reimbursed by the potentially responsible parties. Key assumptions involve the typical quickest turnaround time provided by the onsite and offsite laboratories. Costs for the operation of a wastewater treatment system and the remediation of a site area or property were provided by personnel who have been involved in the operation of a large FUSRAP site in New Jersey for many years. This study provides valuable information for determining the most cost-effective approach for analysis of project samples and therefore may be used on upcoming FUSRAP projects. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ammonia capture and recovery system and method for removing ammonia from a wastewater stream

A wastewater stream including ammonia and water is fed to at least one packed column including packing material having a surface of solid magnesium phosphate or solid magnesium ammonium phosphate or both. Each of the packed columns is capable of cycling between an ammonia absorption operation and an ammonia regeneration operation. The magnesium phosphate compound reacts with the water and ammonia to form a magnesium ammonium phosphate compound. In one embodiment, this system provides for the regeneration of the magnesium ammonium phosphate compound for further use as an ammonia sorber. In another embodiment, the magnesium ammonium phosphate compound is used as fertilizer. Additionally, the ammonia capture and recovery system may be used in conjunction with other unit operations in an overall wastewater treatment system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microbiome response in an urban river system is dominated by seasonality over wastewater treatment upgrades

Background: Microorganisms such as coliform-forming bacteria are commonly used to assess freshwater quality for drinking and recreational use. However, such organisms do not exist in isolation; they exist within the context of dynamic, interactive microbial communities which vary through space and time. Elucidating spatiotemporal microbial dynamics is imperative for discriminating robust community changes from ephemeral ecological trends, and for improving our overall understanding of the relationship between microbial communities and ecosystem health. We conducted a seven-year (2013–2019) microbial time-series investigation in the Chicago Area Waterways (CAWS): an urban river system which, in 2016, experienced substantial upgrades to disinfection processes at two wastewater reclamation plants (WRPs) that discharge into the CAWS and improved stormwater capture, to improve river water quality and reduce flooding. Using culture-independent and culture-dependent approaches, we compared CAWS microbial ecology before and after the intervention. Results: Examinations of time-resolved beta distances between WRP-adjacent sites showed that community similarity measures were often consistent with the spatial orientation of site locations to one another and to the WRP outfalls. Fecal coliform results suggested that upgrades reduced coliform-associated bacteria in the effluent and the downstream river community. However, examinations of whole community changes through time suggest that the upgrades did little to affect overall riverine community dynamics, which instead were overwhelmingly driven by yearly patterns consistent with seasonality. Conclusions: This study presents a systematic effort to combine 16S rRNA gene amplicon sequencing with traditional culture-based methods to evaluate the influence of treatment innovations and systems upgrades on the microbiome of the Chicago Area Waterway System, representing the longest and most comprehensive characterization of the microbiome of an urban waterway yet attempted. We found that the systems upgrades were successful in improving specific water quality measures immediately downstream of wastewater outflows. Additionally, we found that the implementation of the water quality improvement measures to the river system did not disrupt the overall dynamics of the downstream microbial community, which remained heavily influenced by seasonal trends. Such results emphasize the dynamic nature of microbiomes in open environmental systems such as the CAWS, but also suggest that the seasonal oscillations remain consistent even when perturbed.

16S rRNA gene sequencing↗

Integrated protonic ceramic electrochemical cell for sustainable energy economy using water-energy nexus framework

Reliance on fossil fuels will continue for the next decades even though there are global pushes away from it to mitigate the overarching climate challenge, most especially by its highest consumers and availability. While there is a hastening global shift away from fossil fuel, integrating its assets into this technology helps limit the risk and future losses of stranded assets and reduce the cost of investment in the new technologies. Moreover, the generation of electricity from intermittent renewable sources like solar and wind has witnessed a significant surge in recent years, leading to a pressing demand for practical energy storage systems. Electrical energy storage is anticipated to play a pivotal role in the future global energy system, facilitating load-leveling operations to support the greater integration of renewable and distributed generation. Reversible electrochemical cells (RECs) offer a promising option for addressing the fossil fuel assets integration and energy storage challenges through the interconversion between electrical and chemical energy and concurrent utilizing carbon emission. In their electrolysis mode, the RECs convert electricity into durable, storable, and portable valuable chemical fuels such as syngas and methane. Conversely, the produced chemical fuels can be used as reactants in the fuel cell mode to generate electricity on demand with minimal (hydrocarbons) or zero when H2 or NH3 is used emissions. However, a challenging goal for this type of technology remains to achieve optimal operation and high roundtrip efficiencies, which has hindered the deployment of previous electrochemical cells. This dissertation demonstrates how reversible protonic ceramic electrochemical cells (RePCECs) can be integrated with fossil fuel power plants and renewable energy sources as a potential energy storage system. In this work, integrated RePCEC systems are designed and examined using computational modeling at scales to determine appropriate system configurations and operating conditions that achieve high roundtrip efficiencies. Cell level design of the PCEC is the first approach, several cells are assembled for the stack level model that is integrated into combined cycle powerplant and solar photovoltaic for the system level model. After critical literature review, this answered the operational and integration research questions proposed to address these challenges. The designed systems perform two functions, utilizing captured CO2 and storing renewable energy through co-electrolysis of steam and CO2. The co-electrolysis reaction involves endothermic water electrolysis and exothermic methanation reaction. To enhance high roundtrip efficiency, there is a need for thermal balance and management in the electrolysis mode. This involves operating the RePCEC stack under conditions that favor methane production to balance out heat needed by water electrolysis, it crucial for the RePCEC system operation. Methanation is enhanced by low temperatures. Leveraging on fabricated BCZYYb-electrolyte RePCEC, the cell model designed revealed that the optimum temperature for methane production is 450℃ at atmospheric pressure. Thus, to achieve optimum system performance, operating in the temperature range 450-525℃ is recommended at the given configuration, combining between the optimum temperature for methane production and temperature for the optimum stack roundtrip efficiency. Configuration with carbon capture system and purge stream is the optimum configuration from the seven conceptualized and evaluated. The modeling outcomes include a thermodynamic examination of integrated RePCEC systems, calibration of cell and stack level models, and steady-state simulation and integration into a 600MW combined cycle power plant retrofitted with two two-stage membrane-based carbon capture system and a wastewater treatment and recovery unit. At 100% powerplant loading, the stack and system roundtrip efficiencies are 72% and 51.37% respectively. Adding a purge stream for produced hydrogen at the system downstream improves the efficiencies to 74 and 55.48% respectively. At atmospheric pressure and 525℃, the system model suggests that a stack roundtrip of 82% is achievable, and overall system efficiency increases by reducing the energy consumption by the balance of plant components for steam generation and storage. Economic analysis of the process gives levelized cost of methane as $2.24/MMBtu lower than the conventional production route that range between $3.46/MMBtu and $9.85/MMBtu. The lifecycle analysis shows that the global warming potential for the production of methane and hydrogen from the RePCEC system is 3.83 kg CO2 eq which is lower than 9.35 kg CO2 eq emission during steam methane reforming for hydrogen production. This answered both the environmental and economic concerns in the raised research question. The proposed RePCEC configuration and analysis carried out in this dissertation to address the surge in renewable energy and challenges with PCEC technology hold significant potential in achieving large-scale energy storage while simultaneously reducing carbon emissions. These advancements, coupled with suitable governmental policies and incentive programs, have the potential to economically disrupt the natural gas industries by using RePCEC systems for methane production, thereby making them more favorable for eventual implementation and commercialization.

25 ENERGY STORAGE↗

In anaerobic reactors the microbial community structure depends on feed type, with no “keystone” species tied to COD removal

Two-stage anaerobic digestion (AD) systems provide treatment for high strength wastewater with high stability and performance. Encapsulation technology can intensify AD to facilitate the separation of the solids retention time from the hydraulic retention time (HRT), offering lower HRTs, smaller reactors, and high effluent quality. To support successful deployment, however, the encapsulated community must contain all the needed microorganisms for successful treatment and be flexible enough to treat a variety of wastewaters. Here, a two-stage system was investigated in which microbial cultures were enriched on various high-strength wastewaters in suspended flow-through systems to determine how feed type influenced performance and microbial community structure. The hypothesis was that specific genera, or so-called “keystone species” would positively correlate to organic carbon degradation for a given feed, enabling construction of a well-functioning community for encapsulation. Results showed that the number of total bacteria (as 16S rRNA gene copies) did not correlate to soluble chemical oxygen demand (sCOD) removal, indicating that the community structure and/or members were important for good performance. Results also showed that feed type strongly influenced carbon removal and microbial community structure for 1st-stage fermenting communities, but not 2nd-stage methanogenic communities. In this study, the “core” community members were defined as organisms common to all of either the 1st- or 2nd-stage reactors irrespective of the feed they received and were present in at least 50% of the samples throughout the entire experiment. “Unique” community members were specific to a single feed, and hence, only present in either the 1st- or 2nd-stage reactors receiving that feed. In both 1st- and 2nd-stage communities, only one core genera and no unique genera were positively and significantly correlated to sCOD removal. Verification experiments performed with encapsulated communities showed that organisms identified in flow-through system and correlated with carbon degradation, though not significantly, seemed to be important for performance. Our results suggest that one cannot construct a community containing specific populations in lieu of enrichment. Nevertheless, a single diverse encapsulated anaerobic community should provide good (>80%) carbon removal when fed a variety of influents, if time is provided for enrichment after deployment.

54 ENVIRONMENTAL SCIENCES↗

Hybrid Cooling and Water Treatment for Resilient, Water-Self-Sufficient Data Centers

The continued growth of data center infrastructure is intensifying demand for freshwater resources, particularly in water-stressed regions, and is increasingly limiting sustainable capacity expansion. This work investigates a conceptual hybrid system that integrates freeze desalination with ultrasonic-assisted ice separation to enable on-site production of pure water from diverse sources, including seawater, brackish groundwater, and reclaimed industrial or agricultural wastewater. Simultaneously, the system produces low-temperature cooling streams that enhance heat removal in high power density computing environments. A process-level thermodynamic analysis is performed across a range of boundary and operating conditions, including variations in feed concentration, freezing temperature, and mass flow rate. The results are presented as performance curves relating feedwater concentration and target purified water output to the corresponding intake flow requirements, enabling estimation of source water demand per unit of Information Technology Equipment (ITE) energy consumption (kWh) across varying data center scales and operational scenarios. The corresponding electrical energy consumption for integrated cooling and water treatment is also evaluated as a function of system operating parameters and target water production levels. These results provide a basis for evaluating system feasibility across different conditions and for identifying parameter ranges in which integrated water treatment and cooling improve resource efficiency, thermal performance, and operational flexibility in data centers.

Elhefny, Aly [ORNL] (ORCID:0000000284907923)↗