Search NASA⌕ Search

SEARCH · Search NASA

Results for “Water Electrolysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Porous transport electrodes for oxygen evolution reaction in proton exchange membrane water electrolysis -cells: Materials, designs, and diagnoses

H 2 production using proton exchange membrane (PEM) water electrolysis (PEMWE) cells has received considerable attention because of the high efficiencies of these cells and no harmful emissions from the related process. In PEMWE cells, porous transport electrodes (PTEs) composed of a catalyst layer (CL) comprising O 2 evolution reaction (OER) catalysts, porous transport layer (PTL), and PEM play key roles in the stack performance and lifetime. Herein, Ir-based and non-precious-metal OER catalysts that are highly active and stable at low pH values and high anodic potentials are reviewed to understand their OER mechanisms. Various strategies are proposed for engineering CLs and PTLs to improve the interfacial properties and mass transfers of reactants and products to and from the active sites. Additionally, diagnoses of PTEs is significantly crucial for interpreting electrochemical processes and addressing their current challenges. Therefore, half-cell analyses, including diffusion electrode (DE), floating electrode (FE), and modified rotating disk electrode (MRDE) techniques, are explored, and membrane electrode assembly (MEA)-based analyses, such as the polarization technique, electrochemical impedance spectroscopy, and magnetic field analysis, are established. In conclusion, this study aims to provide an overview of recent technologies used for the engineering and diagnostic tools of PEMWE cells and insights into the advanced components and systems to be developed in this field.

Diagnosis of PEMWE Cells↗

Durable, Ultra-Thin Diaphragms for Liquid Alkaline Water Electrolysis

W. L. Gore & Associates assembled a world class team (De Nora Tech, LLC; New York University; and thyssenkrupp nucera) to develop durable, ultra-low resistance diaphragms that dramatically improve system efficiency, dynamic response, and operational flexibility. To enable the use of ultra-thin diaphragms, an optimized electrode package was chosen as part of an electrode down select study. Ultra-thin diaphragms based on microporous polymer scaffolds imbibed with zirconia nanoparticles were developed and tested. Performance and durability on par with incumbent materials was demonstrated. A transparent electrolyzer to directly observe in-situ diaphragm-bubble interactions was designed and built, and simultaneous optical and electrochemical performance tests were performed. A Pressurized Alkaline Water Electrolysis (PAWE) single cell test station was designed to support advanced R&D in high-pressure electrolysis, particularly for evaluating novel electrode and separator configurations under elevated temperature and pressure operating conditions. Due to early project termination, the original scope could not be fully achieved.

08 HYDROGEN↗

Ionomer-free and recyclable porous-transport electrode for high-performing proton-exchange-membrane water electrolysis

Abstract Clean hydrogen production requires large-scale deployment of water-electrolysis technologies, particularly proton-exchange-membrane water electrolyzers (PEMWEs). However, as iridium-based electrocatalysts remain the only practical option for PEMWEs, their low abundance will become a bottleneck for a sustainable hydrogen economy. Herein, we propose high-performing and durable ionomer-free porous transport electrodes (PTEs) with facile recycling features enabling Ir thrifting and reclamation. The ionomer-free porous transport electrodes offer a practical pathway to investigate the role of ionomer in the catalyst layer and, from microelectrode measurements, point to an ionomer poisoning effect for the oxygen evolution reaction. The ionomer-free porous transport electrodes demonstrate a voltage reduction of > 600 mV compared to conventional ionomer-coated porous transport electrodes at 1.8 A cm −2 and <0.1 mg Ir cm −2 , and a voltage degradation of 29 mV at average rate of 0.58 mV per 1000-cycles after 50k cycles of accelerated-stress tests at 4 A cm −2 . Moreover, the ionomer-free feature enables facile recycling of multiple components of PEMWEs, which is critical to a circular clean hydrogen economy.

08 HYDROGEN↗

Characterization of Porous Transport Layers Towards the Development of Efficient Proton Exchange Membrane Water Electrolysis

The current goals for implementing the hydrogen economy have highlighted a need to further optimize water-splitting technologies for clean hydrogen production. Proton exchange membrane water electrolysis (PEMWE) is a leading technology, but further optimizations of anode materials including the porous transport layer (PTL) and the adjacent catalyst layer (CL) are required to increase overall cell performance and reduce cost. This literature review describes advances in PTL development and characterization, highlighting early PTL characterization work and most common methods including capillary flow porometry and mercury intrusion porometry, optical imaging, neutron and x-ray radiography, and x-ray computed tomography. The article also discusses PTL protective coatings and their characterizations, focusing on platinum group metal (PGM)-based coatings, alternative non-PGM-based coatings, post-treated PTLs, and investigations into thin PGM-based coatings. Furthermore, it highlights the integration of the PTL and the adjacent CL along with associated characterization challenges. Lastly, this review discusses future developments in the characterization needed to improve PEMWE's performance and long-term durability are discussed.

08 HYDROGEN↗

Quantifying Sources of Long-Term Voltage Decay for Rutile Iridium Oxide Anodes in Proton Exchange Membrane Water Electrolysis

To achieve aggressive hydrogen cost targets for proton exchange membrane water electrolysis (PEMWE), it is necessary to develop catalyst systems that reduce precious metal loadings while maintaining performance over extended operation. While amorphous iridium (Ir) -based catalysts exhibit high initial activity, their long-term stability remains a key limitation. In this study, the behavior of a rutile IrO2 catalyst is investigated over 4000 h of durability testing and compared to past efforts evaluating a more amorphous material. This study finds that rutile IrO2 results in a smaller decay rate (4.9 ..mu..V h-1) than an amorphous catalyst (28 ..mu..V h-1); additionally, the rutile IrO2 results in a smaller degree of Ir migration (20% to the membrane and cathode) than an amorphous catalyst (35%). This research emphasizes rutile IrO2 as a promising avenue for the development of durable, low-iridium anodes that can meet lifetime and cost targets for next-generation electrolyzer systems.

08 HYDROGEN↗

Optimizing Porous Transport Layer Porosity for Proton Exchange Membrane Water Electrolysis

An empirical model is presented that describes anode-side losses related to porous transport layer (PTL) morphology in proton exchange membrane water electrolysis (PEMWE). The model is based on an advanced voltage breakdown analysis that links various overpotentials to PTL morphology. Custom Ti PTLs, spanning uncommonly low porosities (22 - 31%), were fabricated and analyzed with X-ray CT to obtain pore and particle size distributions. Particle size distributions were consistent across samples with an average particle diameter of 12.0?..mu..m, whereas average pore diameters ranged from 6.0 to 7.0?..mu..m. The PTLs were tested in standard PEMWE cell assemblies with anode catalyst loadings of 0.1 mgIr cm-2 to obtain polarization curves, electrochemical impedance spectra, and augmented Tafel analysis. The PTL-dependent anode side losses were deconvoluted and assigned to excess utilization, concentration, ion transport resistance, and electrical contact resistance overpotentials. The data and model reveal an optimal 20 - 28% PTL porosity region where utilization and contact resistance overpotentials are minimized without triggering concentration and ion transport losses related to water deprivation. The optimal PTL porosity depends on the operating current density and is demonstrated at realistic PEMWE water flow rates to establish PTL design guidance for operation at scale.

08 HYDROGEN↗

Performance of Polymer Electrolyte Membrane Water Electrolysis Systems: Configuration, Stack Materials, Turndown and Efficiency

A cell model is developed and validated to analyze the performance of polymer electrolyte membrane water electrolysis (PEMWE) stacks and systems. It is used to characterize the oxygen evolution reaction (OER) activity on a TiO2-supported IrO2 catalyst and an unsupported IrO2 powder catalyst. Electrochemical, stack, and system thermoneutral potentials are defined and determined for isothermal and non-isothermal stack operation. Conditions are determined under which the system thermoneutral potential or flammability of H2 in the O2 anode stream limits the stack turndown and operating temperature. Performance is analyzed of a complete PEMWE system with an electrolyzer stack containing an IrO2/TiO2 anode catalyst (2 mg/cm2 Ir loading) and N117-like membrane mitigated for H2 crossover, anode balance-of-plant (BOP) components, cathode BOP system with temperature swing adsorption for H2 purification, and electrical BOP system with transformer and rectifier. At the rated power condition, defined as 2 A/cm2 at 1.9 V, 80 °C, and 30 bar H2 pressure, the stack/system efficiency is 65.3%/60.3% at beginning of life (BOL), decreasing to 59.3%/53.9% at end of life (EOL). The peak stack/system efficiency is 76.3%/70.2% at BOL, decreasing to 71.2%/65.6% at EOL. Improvements in catalyst activity and membrane are identified for a 50% increase in current to 3 A/cm2 at 1.8 V.

36 MATERIALS SCIENCE↗

Reversible Losses in Proton Exchange Membrane Water Electrolysis

Lower anode catalyst loadings and higher current densities are essential to lowering the levelized cost of H 2 production via proton exchange membrane water electrolysis (PEMWE). However, these approaches can induce significant durability challenges. Here, we show that cell degradation can include large reversible voltage losses across a variety of conditions, including low loadings and high currents. Although there is limited published discussion of reversible voltage losses in PEMWE, we demonstrate that they are an important consideration in cell efficiency and durability. Understanding the mechanisms of reversible losses and developing mitigation strategies is therefore a key priority for enabling low-cost PEMWE.

08 HYDROGEN↗

How Low Can You Go? Nanoscale Membranes for Efficient Water Electrolysis

Motivated by the need to lower the cost of hydrogen (H 2 ) production by water electrolysis, significant research efforts are focused on making proton (H + ) exchange membrane (PEM) water electrolyzers more efficient and capable of operating at higher current densities. These aims can be met by making H + -conducting membranes thinner, which has the effect of lowering ohmic drops across the membrane that represent the largest efficiency loss at high current densities (>2 A cm –2 ). However, decreasing membrane thickness below 50 μm is not trivial due to trade-offs between membrane resistance, H 2 crossover (safety), membrane degradation, and manufacturing throughput. Furthermore, descriptions of key processes, limitations, and trade-offs that arise in thin membranes are provided that can be used to guide the design of ultrathin (i.e., submicron thick), low-resistance membrane materials that have the potential to transform the field of clean H 2 production.

08 HYDROGEN↗

Quantifying Sources of Voltage Decay in Long-Term Durability Testing for PEM Water Electrolysis

Meeting a competitive 1$/kg hydrogen cost target for polymer electrolyte membrane water electrolysis (PEMWE) will require advances to significantly reduce capital costs and precious metal catalyst usage, while simultaneously enabling 40,000–80,000 h stack lifetimes under dynamic use conditions. Minimizing cell voltage decay rates is therefore a key goal for PEMWE, although the fundamental processes governing voltage decay are not yet well understood. Here we present a quantitative approach to analyze the contributions to voltage decay in long-term PEMWE testing using polarization curves, impedance spectroscopy, and post-mortem electron microscopy. We apply this approach to analyze a 28 μV h −1 decay rate observed in a 4000 h durability test of a cell using 0.5 mg cm −2 total PGM catalyst loading (0.4 mg Ir cm −2 anode, 0.1 mg Pt cm −2 cathode) and 3 A cm −2 current density. We also analyze a comparative series of 1000 h tests under different conditions. These results provide valuable insights into anode catalyst degradation processes, as well as transferrable methodology for PEMWE durability research.

08 HYDROGEN↗

Durable Thin‐Film Porous Transport Electrodes for High Current Density PEM Water Electrolysis

Proton exchange membrane water electrolyzers rely on relatively expensive Ir-based catalysts for efficient and durable hydrogen production. To reduce system costs, Ir loadings can be reduced if performance and durability are maintained. Sputter deposition is a readily scalable method to synthesize uniform, low-loading catalyst layers with controlled composition. A catalyst applied directly to the porous transport layer can have advantages for performance, manufacturing simplicity, and catalyst recovery. Suitable porous transport layer porosity can minimize activity losses when reducing loadings. Here, methods are presented to deposit metallic Ir as well as amorphous and rutile Ir oxides. The activity and durability of these materials in the porous transport electrode architecture is evaluated. The metallic and amorphous forms have better initial activity, however, operation at 3 A cm −2 with 0.1 mg Ir cm −2 shows that only rutile IrO 2 maintains performance beyond 100 h with a 50 mV improvement after 700 h. A >10x reduced dissolution rate is shown for rutile IrO 2 . With a low-porosity transport layer and 0.4 mg Ir cm −2 , a steady-state voltage decay rate of 6 µV h −1 is achieved. The results demonstrate that sputter-deposited rutile IrO 2 porous transport electrodes with low Ir loading can be operated at high current density to reduce hydrogen production costs.

08 HYDROGEN↗

Modeling the Effect of Material Properties on Liquid-Alkaline Water Electrolysis

Liquid-alkaline water electrolyzers (LAWEs) use electricity to drive the conversion of water to H 2 and O 2 gas. These devices benefit from the use of low-cost nickel electrodes and metal-oxide separators, but suffer from lower current densities and higher cell voltages than proton-exchange-membrane water electrolyzers. Identifying the inefficiencies that result in this poor performance is key to mitigating losses and optimizing LAWEs. Here, we report an experimentally-validated 1-D continuum model of a LAWE that elucidates the gradients within the cell, simulates H 2 crossover, and projects the energy improvements made possible by modulating the properties of the electrodes and separator. The model captures the Nernstian polarization losses and the distribution of gas- and liquid-phases within the electrodes, enabling quantification of energy losses associated with kinetic, ohmic, and bubble-induced (mass-transport) resistances. Simulations demonstrate that LAWE can achieve energy intensities of 50 kWh kg −1 of H 2 at 1 A cm −2 using improved electrode and separator properties.

08 HYDROGEN↗

Proton Conducting Silicon Oxide Membranes as a Fluorine Free Alternative to Nafion for Low Temperature Water Electrolysis

Driven by environmental and health concerns related to per- and polyfluoroalkyl substances (PFAS), there has been growing interest in developing fluorine-free proton (H + ) exchange membrane (PEM) materials for fuel cells and water electrolyzers. In this study, we present a side-by-side comparison of the key transport properties of submicron thick, PFAS-free amorphous silicon dioxide (SiO 2 ) membranes to Nafion, a fluorinated polymer electrolyte membrane that represents the industry standard for PEM fuel cells and electrolyzers. Here, measurements of proton (H + ) conductivity (σ H + ), hydrogen (H 2 ) permeability (P H 2 ), and electrical resistivity (ρ e – ) were conducted using model thin films comprised of SiO 2 membranes deposited by atomic layer deposition (ALD). Although the H + conductivity of the SiO 2 membranes is 2–3 orders of magnitude lower than Nafion, the addition of phosphorus dopants (PO x ) improves H + conductivity such that the area specific membrane resistance of thin (<50 nm) PO x -doped SiO 2 membranes is more than an order of magnitude lower than Nafion-117. Importantly, the safe operation of such nanoscale membranes within a PEM electrolyzer is feasible thanks to the low H 2 permeability of dense SiO 2 -based membranes, which are predicted to limit H 2 crossover rates to acceptable levels for pressures up to ≈ 100 bar. As a proof-of-principle demonstration, a chip-scale water electrolyzer based on 100 nm thick PO x -SiO 2 membrane is shown to achieve a current density of 2 A cm –2 at a potential of 2.5 V. If this technology can be successfully scaled up, H + conducting oxide membranes offer an attractive PFAS-free alternative to Nafion for efficient and durable water electrolysis and fuel cell technologies.

Nafion↗

High-performance multiblock PEMs containing a highly acidic fluorinated-hydrophilic domain for water electrolysis

The present paper describes the design and evaluation of novel hydrophilic–hydrophobic poly(arylene ether sulfone) (PAES) multiblock copolymers for their synergistic effects upon transport properties and their potential use in proton exchange membrane water electrolysis. The multiblock copolymers are prepared via a coupling reaction between (i) a hydrophilic segment consisting of a disulfonated quinone fluorinated biphenyl group that contains fluorine moieties next to the sulfonated groups to increase the acidity, and (ii) hydrophobic segments composed of non-sulfonated biphenyl sulfone to provide dimensional stability. Two different lengths (molecular weights; 5k and 10k, where k represents 10 3 g mol -1 ) of hydrophobic segments are used to investigate the effects of the membrane properties compared with those of Nafion® and PAES random copolymer (i.e., BPSH40). Atomic force microscopy images of the BPSH40 and multiblock membranes are shown to agree closely with a mesoscale simulation, thus confirming the importance of the morphological effect upon the transport properties. Furthermore, the multiblock copolymer with a higher proportion of hydrophilic segments (10 k–5k) was shown to provide enhanced performance (3.41 A cm -2 at 1.9 V) compared to the multiblock copolymer with equal proportions of hydrophilic and hydrophobic segments (10 k–10 k) due to the greater continuity of nano-sized ionic channels.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The dual role of iron in alkaline water electrolysis: A friend or a foe?

Trace iron (Fe) impurities pose a challenge in alkaline water electrolysis (AWE) and can significantly impact long-term performance, yet their comprehensive system-level effects remain poorly understood. Here, we present the mechanistic roles of Fe in AWE, using combined rotation disk electrode studies, zero-gap cell measurements, and durability tests up to 1,000 h. Fundamental electrochemistry shows that Fe deposition proceeds through a solution-mediated pathway, with dendritic growth triggered under specific mass-transport and potential conditions. In single-cell operation, Fe incorporation substantially enhances nickel (Ni)-based anode activity by forming highly active Ni-Fe oxyhydroxides, while cathodic Fe forms either thin films or dendrites, depending on potential, surface morphology, and electrolyte distribution. Although dendrites do not degrade hydrogen evolution performance up to 1,000 h, they reveal partial intrusion into the separator, indicating a potential durability risk. We identify five governing factors controlling Fe dendrite formation and provide design principles for impurity-resilient AWE systems.

Lyu, Xiang [ORNL] (ORCID:0000000208673248)↗

An Acid-Free, Temperature-Based Cation Contamination Removal Strategy for PEM Water Electrolysis

It is widely understood that the durability and reliability of polymer electrolyte membrane (PEM) water electrolyzers are heavily dependent on feedwater purity, with cation contaminants that originate from incomplete water purification and balance of plant materials significantly harming electrolyzer performance. However, contamination remains a challenge and a common cause of failure at the stack level, indicating the need for strategies to recover the performance of contaminated cells. In this study, we investigate the effects of temperature on the uptake, electrochemical impacts, and removal of contaminant calcium and iron cations. Lower operating temperatures increase the sensitivity of the cell performance to contaminant cations, while also decreasing cation uptake and promoting contaminant removal. Computational charge transfer modelling shows that lower temperature increases the concentration of contaminant at the cathode and facilitates their removal from the cell. By testing single cells under scenarios designed to mimic stack temperature dynamics, we investigate low-temperature operation as an approach to stack-relevant contaminant recovery. Together, these results demonstrate that the low-temperature recovery approach is a promising approach for acid-free contamination recovery for PEM water electrolysis to promote stack reliability and durability.

08 HYDROGEN↗

Voltage breakdown analyses in anion exchange membrane water electrolysis – the contributions of catalyst layer resistance on overall overpotentials

Despite many recent advances, overpotentials remain high for anion exchange membrane water electrolyzers (AEMWEs). Voltage breakdown analyses (VBA) can help decouple the origins of overpotentials and facilitate design decisions to improve cell performance, but studies investigating how to adapt and apply VBA to AEMWEs are lacking. Specifically, catalyst layer resistances and their contributions to overpotentials are not consistently quantified in water electrolysis and are rarely quantified for AEMWEs. This work presents a systematic methodology for VBA tailored to AEMWEs, including an approach to Tafel analysis in the absence of a reference electrode and under conditions where both the oxygen evolution reaction and hydrogen evolution reaction exhibit significant overpotentials. Catalyst layer resistance contributions are diagnosed via changes in the catalyst layer thickness, transport layer porosity, ionomer content, and electrolyte concentration. In this study, we explain discrepancies between inherent catalytic kinetics and device level performance and identify catalyst layer design strategies to reduce catalyst layer resistances.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗