Search NASA⌕ Search

SEARCH · Search NASA

Results for “Weibull analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The effects of temperature gradient and growth rate on the morphology and fatigue properties of MAR-M246(Hf)

MAR-M246(Hf) is a nickel based superalloy used in the turbopump blades of the Space Shuttle main engines. The effects are considered of temperature gradient (G) and growth rate (R) on the microstructure and fatigue properties of this superalloy. The primary dendrite arm spacings were found to be inversely proportional to both temperature gradient and growth rate. Carbide and gamma - gamma prime morphology trends were related to G/R ratios. Weibull analysis of fatigue results shows the characteristic life to be larger by a factor of 10 for the low gradient/fast rate pairing of G and R, while the reliability (beta) was lower.

Schmidt, D. D.↗

The effects of multiple repairs on Inconel 718 weld mechanical properties

Inconel 718 weldments were repaired 3, 6, 9, and 13 times using the gas tungsten arc welding process. The welded panels were machined into mechanical test specimens, postweld heat treated, and nondestructively tested. Tensile properties and high cycle fatigue life were evaluated and the results compared to unrepaired weld properties. Mechanical property data were analyzed using the statistical methods of difference in means for tensile properties and difference in log means and Weibull analysis for high cycle fatigue properties. Statistical analysis performed on the data did not show a significant decrease in tensile or high cycle fatigue properties due to the repeated repairs. Some degradation was observed in all properties, however, it was minimal.

Russell, C. K.↗

A statistical comparison of two carbon fiber/epoxy fabrication techniques

A statistical comparison of the compression strengths of specimens that were fabricated by either a platen press or an autoclave were performed on IM6/3501-6 carbon/epoxy composites of 16-ply (0,+45,90,-45)(sub S2) lay-up configuration. The samples were cured with the same parameters and processing materials. It was found that the autoclaved panels were thicker than the platen press cured samples. Two hundred samples of each type of cure process were compression tested. The autoclaved samples had an average strength of 450 MPa (65.5 ksi), while the press cured samples had an average strength of 370 MPa (54.0 ksi). A Weibull analysis of the data showed that there is only a 30 pct. probability that the two types of cure systems yield specimens that can be considered from the same family.

Hodge, A. J.↗

NASA Tech Briefs, September 2005

Topivs include: Diamond-Coated Carbon Nanotubes for Efficient Field Emission; Improved Anode Coatings for Direct Methanol Fuel Cells; Advanced Ablative Insulators and Methods of Making Them; PETIs as High-Temperature Resin-Transfer-Molding Materials; Stable Polyimides for Terrestrial and Space Uses; Low-Density, Aerogel-Filled Thermal-Insulation Tiles; High-Performance Polymers Having Low Melt Viscosities; Nonflammable, Hydrophobic Aerogel Composites for Insulation; Front-Side Microstrip Line Feeding a Raised Antenna Patch; Medium-Frequency Pseudonoise Georadar; Facilitating Navigation Through Large Archives; Program for Weibull Analysis of Fatigue Data; Comprehensive Micromechanics-Analysis Code - Version 4.0; Component-Based Visualization System; Software for Engineering Simulations of a Spacecraft; LabVIEW Interface for PCI-SpaceWire Interface Card; Path Following with Slip Compensation for a Mars Rover; International Space Station Electric Power System Performance Code-SPACE; Software for Automation of Real-Time Agents, Version 2; Software for Optimizing Plans Involving Interdependent Goals; Computing Gravitational Fields of Finite-Sized Bodies; Custom Sky-Image Mosaics from NASA's Information Power Grid; ANTLR Tree Grammar Generator and Extensions; Generic Kalman Filter Software; Alignment Stage for a Cryogenic Dilatometer; Rugged Iris Mechanism; Treatments To Produce Stabilized Aluminum Mirrors for Cryogenic Uses; Making AlNx Tunnel Barriers Using a Low-Energy Nitrogen-Ion Beam; Making Wide-IF SIS Mixers with Suspended Metal-Beam Leads; Sol-Gel Glass Holographic Light-Shaping Diffusers; Automated Counting of Particles To Quantify Cleanliness; Phase Correction for GPS Antenna with Nonunique Phase Center; Compact Infrasonic Windscreen; Broadband External-Cavity Diode Laser; High-Efficiency Solar Cells Using Photonic-Bandgap Materials; Generating Solid Models from Topographical Data; Computationally Lightweight Air-Traffic-Control Simulation; Spool Valve for Switching Air Flows Between Two Beds; Partial Model of Insulator/ Insulator Contact Charging; Asymmetric Electrostatic Radiation Shielding for Spacecraft; and Reusable Hybrid Propellant Modules for Outer-Space Transport.

Source record↗

Ball-on-ring test validation for equibiaxial flexural strength testing of engineered ceramics

The validation of a ball-on-ring, equibiaxial flexural strength method to obtain the transverse rupture strength (TRS) of right cylindrical ceramic specimens was performed in this study. Validation of the test method was achieved using commercially available engineered high purity alumina disks and finite element (FE) model analysis. The validated fixture was then used to obtain the TRS and Weibull statistical analysis of MgO-partially stabilized zirconia (MSZ) and Y 2 O 3 -partially stabilized zirconia (YSZ) ceramic disks. TRS data for alumina, MSZ, and YSZ agreed with the TRS values reported in the literature. A statistically relevant number of samples (N > 30) for each material were tested to allow for a Weibull statistical analysis. Weibull parameters for these materials were within the expected values for engineered ceramics. The characteristic strength for alumina, MSZ, and YSZ were determined to be 289, 786, and 814 MPa, respectively. The Weibull modulus was determined between 10 and 25 for each material, which is typical of engineered ceramics. In addition, FE model results were in close agreement with experimental fracture values for the three ceramic materials tested in this study.

36 MATERIALS SCIENCE↗

Fatigue and flexural response of advanced carbon-carbon composites at room and elevated temperatures

The flexural response of SiC-coated carbon-carbon composites (ACC-4) at room and elevated temperatures is presented. Three-point bending tests were performed on virgin and mission-cycled specimens, and the variation in flexural strength is examined. The load-deflection behavior of the material at various temperatures is investigated, and the Weibull (1939) analysis of the strength data is performed. Micrographs of various cross sections in the damaged zone were taken, and the failure mechanisms are discussed. Fatigue tests were conducted under flexural loads, and the S-N diagram with the corresponding Weibull analysis are presented. Untested as well as fractured specimens under static and dynamic loading were C-scanned to identify the damaged zone and visualize the extent of the damage. Failure analyses are presented for both static and cyclic loading on the basis of NDE, the micrographs, and the experimental data.

Mahfuz, Hassan↗

Size effects in 3D–printed polymer–derived, zirconium diboride–reinforced ceramic composites

Preceramic polymers are of interest for use in many manufacturing techniques such as injection molding, ceramic fiber infiltration, and additive manufacturing. However, off-gassing of low molecular weight oligomers occurs when these polymers cure, potentially leading to porosity in the cured part. Here to study how porosity and strength are affected by the size of the printed part, and the presence of a high surface area nano-scale filler, polycarbosilane (PCS) microrods of varying diameter were fabricated via direct ink writing (DIW), an additive manufacturing technique, with two ink formulations containing either zirconium diboride (ZrB 2 ) alone, or ZrB 2 and fumed alumina (FA). Sets of microrods were printed in a range of sizes by using print nozzles of 450, 634, 979, 1 346, or 1 702 μm in diameter, which were thermally cured, pyrolyzed to form ceramic composite microrods, and tested in 3-pt flexure. Porosity increased with increasing diameter, while failure strength decreased. For a given nozzle size, the microrods containing FA displayed lower porosity and higher strength (up to ~500 MPa) compared to the microrods containing only ZrB 2 . Weibull strength analysis was performed on each group of microrods and shows that the addition of FA increased Weibull modulus from 4.63 ± 1.56 to 9.35 ± 0.601. In conjunction with optical microscopy, this analysis indicates two distinct flaw populations in the printed materials, porosity which arises during the curing step and cracking which arises during pyrolysis of the larger specimens.

36 MATERIALS SCIENCE↗

Effect of production processes on the fracture strength of silicon solar cells

Fracture of Czochralski silicon wafers during processing is an important factor in solar cell yield and cost. A fracture-mechanics test and analysis program was developed to evaluate fracture strength changes in the in-process wafer-to-cell processing at different stages on a manufacturer's production line. The strength data were described by Weibull statistical analysis and can be interpreted with the surface-flaw distribution of each of the process steps.

Chen, C. P.↗

Equibiaxial flexural strength determination of UO 2 using a ball-on-ring test

To increase nuclear fuel performance and reliability, their mechanical properties require an accurate and statistically relevant assessment. Biaxial flexural strength tests provide an alternative to bend bar techniques for assessing mechanical behavior; namely, the transverse rupture strength (TRS) of ceramic samples. Biaxial test samples require simple geometries and minimal surface preparation, reducing fabrication costs and handling hazards. This study investigated the TRS of polycrystalline UO 2 fuel forms at room temperature using a ball-on-ring test fixture. Here, pellets were fabricated from UO 2 powder using conventional powder processing and sintering techniques. The TRS and Weibull parameters were obtained through Weibull statistics on over 60 UO 2 samples tested under equibiaxial flexure. The larger sample size in this study enabled a more robust Weibull statistical analysis than alternative test methods, which may not capture the stochastic failure of typical ceramics. Furthermore, two different loading ball diameters were employed to assess the impact of contact damage on fracture strength. While Hertzian contact damage was observed with the smaller loading ball, the fracture strength remained unaffected. A fracture analysis of the tested UO 2 samples indicated a mixture of intergranular and transgranular fracture that transitions to transgranular fracture with increasing distance from the fracture origin. The characteristic strength of the combined data sets was determined to be 148 MPa, and the Weibull modulus was determined to be 9.1. The TRS values and Weibull parameters were close to values found in the literature for alternative testing techniques using samples with similar microstructure and density. The findings in this study validate the ball-on-ring method used to obtain the TRS of UO 2 with a sample geometry more representative of nuclear fuels. Additionally, experimental TRS results from this study can be implemented in modeling codes to predict fuel performance, which is critical to fuel burnup extension and advanced nuclear fuel technologies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparison of Weibull strength parameters from flexure and spin tests of brittle materials

Fracture data from five series of four point bend tests of beam and spin tests of flat annular disks were reanalyzed. Silicon nitride and graphite were the test materials. The experimental fracture strengths of the disks were compared with the predicted strengths based on both volume flaw and surface flaw analyses of four point bend data. Volume flaw analysis resulted in a better correlation between disks and beams in three of the five test series than did surface flaw analysis. The Weibull (moduli) and characteristic gage strengths for the disks and beams were also compared. Differences in the experimental Weibull slopes were not statistically significant. It was shown that results from the beam tests can predict the fracture strength of rotating disks.

Holland, Frederic A., Jr.↗

High-Throughput Statistical Interrogation of Mechanical Properties with Build Plate Location and Powder Reuse in AlSi10Mg

Abstract Additive manufacturing (AM) allows agile, rapid manufacturing of geometrically complex components that would otherwise be impossible through traditional manufacturing methods. With this maturing manufacturing technology comes the need to adopt testing methods that are commensurate with the speed of additive manufacturing and take advantage of its geometric flexibility. High-throughput tensile testing (HTT) is a technique that allows a large number of tensile bars to be tested in a short amount of time. In the present study, HTT is used to evaluate AM AlSi10Mg produced using powder bed fusion with a Renishaw AM250 machine. Three parameters were varied in this study: (1) powder reuse history, (2) location on the build plate, and (3) size of the tensile specimen. For all parameter combinations, at least 22 specimens were tested; in several cases, over 40 were tested. This large dataset, consisting of over 500 tensile tests, permits Weibull statistical analysis and provides sufficient fidelity to isolate subtle trends that would have likely been missed in smaller, traditional datasets. The observed trends are rationalized in terms of the role of porosity and surface crust on mechanical response.

Carroll, Jay D. (ORCID:0000000258184709)↗

Fracture strength of GaAs solar cells as a function of manufacturing process steps

Fracture of single crystal GaAs substrate during the solar cell processing is an important factor in solar cell yield and cost. Fracture mechanics technique was utilized to evaluate cell cracking characteristics and changes in fracture strength of GaAs solar cells in a present state-of-the-art of manufacturing process for GaAs solar cells from wafer to complete cell of a typical production line. Considerable change in the fracture strength of GaAs solar cells as a function of cell processing was found. The strength data were described by Weibull statistical analysis and can be interpreted with the change of flaw distribution of each of the manufacturing process steps.

Chen, C. P.↗

Long-life assessment of graphite epoxy materials for Space Station Freedom pressure vessels

Graphite/epoxy composite overwrapped pressure vessels are being considered for use on Space Station Freedom because of their light weight and high efficiency. These composite pressure vessels weigh roughly one-third of comparable all-metal aluminum pressure vessels, and could result in a 15,000-lb weight saving for the propulsion and fluid management and distribution systems. These vessels must resist failures under sustained pressure loads for crew safety considerations and adequate protection of the space structure during their 30-yr life. Weibull statistical analysis techniques have been applied, and a model developed, for predicting long-term stress-rupture behavior based on published short-term test data on composite strands and pressure vessels. Graphite/epoxy materials are calculated to have a 99.99-percent probability of surviving stress rupture for 30 yr under a sustained load of 50 percent ultimate failure strength. Stress-rupture lifetimes are predicted to increase as the size of the pressure vessels increases in support of the viscoelastic load-transfer mechanism proposed for stress rupture of fiber/epoxy composite materials.

Thomas, Donald A.↗

Basis for the thermal-vacuum hot dwell test duration

This work suggests that the hot dwell duration for each test should be determined in two steps: a minimum hot duration of 80 hours be required and then followed by specific tailoring be conducted to arrive at the proper test duration.

early test failure distribution Weibull analysis r↗

Pharmaceuticals Exposed to the Space Environment: Problems and Prospects

The NASA Human Research Program (HRP) Health Countermeasures Element maintains ongoing efforts to inform detailed risks, gaps, and further questions associated with the use of pharmaceuticals in space. Most recently, the Pharmacology Risk Report, released in 2010, illustrates the problems associated with maintaining pharmaceutical efficacy. Since the report, one key publication includes evaluation of pharmaceutical products stored on the International Space Station (ISS). This study shows that selected pharmaceuticals on ISS have a shorter shelf-life in space than corresponding terrestrial controls. The HRP Human Research Roadmap for planetary exploration identifies the risk of ineffective or toxic medications due to long-term storage during missions to Mars. The roadmap also identifies the need to understand and predict how pharmaceuticals will behave when exposed to radiation for long durations. Terrestrial studies of returned samples offer a start for predictive modeling. This paper shows that pharmaceuticals returned to Earth for post-flight analyses are amenable to a Weibull distribution analysis in order to support probabilistic risk assessment modeling. The paper also considers the prospect of passive payloads of key pharmaceuticals on sample return missions outside of Earth's magnetic field to gather additional statistics. Ongoing work in radiation chemistry suggests possible mitigation strategies where future work could be done at cryogenic temperatures to explore methods for preserving the strength of pharmaceuticals in the space radiation environment, perhaps one day leading to an architecture where pharmaceuticals are cached on the Martian surface and preserved cryogenically.

pharmacology↗

Rolling-Bearing Service Life Based on Probable Cause for Removal: A Tutorial

In 1947 and 1952, Gustaf Lundberg and Arvid Palmgren developed what is now referred to as the Lundberg-Palmgren Model for Rolling Bearing Life Prediction based on classical rolling-element fatigue. Today, bearing fatigue probably accounts for less than 5 percent of bearings removed from service for cause. A bearing service life prediction methodology and tutorial indexed to eight probable causes for bearing removal, including fatigue, are presented, which incorporate strict series reliability; Weibull statistical analysis; available published field data from the Naval Air Rework Facility; and 224,000 rolling-element bearings removed for rework from commercial aircraft engines.

Life prediction↗

Effect of Roller Profile on Cylindrical Roller Bearing Life Prediction: Comparison of Bearing Life Theories - Part 1

Four rolling-element bearing life theories were chosen for analysis and compared for a simple roller-race geometry model. The life theories were those of Weibull; Lundberg and Palmgren; Ioannides and Harris; and Zaretsky. The analysis without a fatigue limit of Ioannides and Harris is identical to the Lundberg and Palmgren analysis, and the Weibull analysis is similar to that of Zaretsky if the exponents are chosen to be identical. The resultant predicted life a each stress condition not only depends on the life equation used but also on the Weibull slope assumed. The least variation in predicted life with Weibull slope comes with the Zaretsky equation. Except for a Weibull slope of 1.11, at which the Weibull equation predicts the highest lives, the highest lives are predicted for the Zaretsky equation. For Weibull slopes of 1.5 and 2, both the Lundherg-Palmgren and Ioannides-Harris (where tau(sub u) = 0) equations predict lower lives than the ANSI/ABMA/ISO standard. Based upon the Hertz stresses for line contact, the accepted load-life exponent of 10/3 results in a maximum Hertz stress-life exponent equal to 6.6. This value is inconsistent with that experienced in the field. The assumption of as shear stress fatigue limit tau(sub u) results in Hertz stress-life exponents greater than are experimentally verifiable.

Poplawski, Joseph V.↗