Search NASA⌕ Search

SEARCH · Search NASA

Results for “Wide dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Assessment of the Short-Term Radiometric Stability between Terra MODIS and Landsat 7 ETM+ Sensors

The Landsat 7 (L7) Enhanced Thematic Mapper (ETM+) sensor was launched on April 15th, 1999 and has been in operation for over nine years. It has six reflective solar spectral bands located in the visible and shortwave infrared part of the electromagnetic spectrum (0.5 - 2.5 micron) at a spatial resolution of 30 m. The on-board calibrators are used to monitor the on-orbit sensor system changes. The ETM+ performs solar calibrations using on-board Full Aperture Solar Calibrator (FASC) and the Partial Aperture Solar Calibrator (PASC). The Internal Calibrator Lamp (IC) lamps, a blackbody and shutter optics constitute the on-orbit calibration mechanism for ETM+. On 31 May 2003, a malfunction of the scan-line corrector (SLC) mirror assembly resulted in the loss of approximately 22% of the normal scene area. The missing data affects most of the image with scan gaps varying in width from one pixel or less near the centre of the image to 14 pixels along the east and west edges of the image, creating a wedge-shaped pattern. However, the SLC failure has no impacts on the radiometric performance of the valid pixels. On December 18, 1999, the Moderate Resolution Imaging Spectroradiometer (MODIS) Proto-Flight Model (PFM) was launched on-board the NASA's EOS Terra spacecraft. Terra MODIS has 36 spectral bands with wavelengths ranging from 0.41 to 14.5 micron and collects data over a wide field of view angle (+/-55 deg) at three nadir spatial resolutions of 250 m, 500 in 1 km for bands 1 to 2, 3 to 7, and 8 to 36, respectively. It has 20 reflective solar bands (RSB) with spectral wavelengths from 0.41 to 2.1 micron. The RSB radiometric calibration is performed by using on-board solar diffuser (SD), solar diffuser stability monitor (SDSM), space-view (SV), and spectro-radiometric calibration assembly (SRCA). Through the SV port, periodic lunar observations are used to track radiometric response changes at different angles of incidence (AOI) of the scan mirror. As a part of the AM Constellation satellites, Terra MODIS flies approximately 30 minutes behind L7 ETM+ in the same orbit. The orbit of L7 is repetitive, circular, sunsynchronous, and near polar at a nominal altitude of 705 km (438 miles) at the Equator. The spacecraft crosses the Equator from north to south on a descending node between 10:00 AM and 10:15 AM. Circling the Earth at 7.5 km/sec, each orbit takes nearly 99 minutes. The spacecraft completes just over 14 orbits per day, covering the entire Earth between 81 degrees north and south latitude every 16 days. The longest continuous imaging swath that L7 sensor can collect is for a 14-minute subinterval contact period which is equivalent to 35 full WRS-2 scenes. On the other hand, Terra can provide the entire corresponding orbit with wider swath at any given ETM+ collection without contact time limitation. There are six spectral matching band pairs between MODIS (bands 3, 4, 1, 2, 6, 7) and ETM+ (bands 1, 2, 3, 4, 5, 7) sensor. MODIS has narrower spectral responses than ETM+ in all the bands. A short-term radiometric stability was evaluated using continuous ETM+ scenes within the contact period and the corresponding half orbit MODIS scenes. The near simultaneous earth observations (SNO) were limited by the smaller swath size of ETM+ (187 km) as compared to MODIS (2330 km). Two sets of continuous granules for MODIS and ETM+ were selected and mosaiced based on pixel geolocation information for non cloudy pixels over the North American continent. The Top-of- Atmosphere (TOA) reflectances were computed for the spectrally matching bands between ETM+ and MODIS over the regions of interest (ROI). The matching pixel pairs were aggregated from a finer to a coarser pixel resolution and the TOA reflectance values covering a wide dynamic range of the sensors were compared and analyzed. Considering the uncertainties of the absolute calibration of the both sensors, radiometric stability was verified for the band pairs. The Railroad Valley Playa, Nada (RVPN) was included in the path of this continuous orbit, which served as a verification point between the shortterm and the long-term trending results from previous studies. This work focuses on monitoring the short-term on-orbit stability of MODIS and the ETM+ RSB. It also provides an assessment of the absolute calibration differences between the two sensors over their wide dynamic ranges.

Choi, Taeyoung↗

Comparative analyses of plasma probe diagnostics techniques

The subject of this paper is a comparative analysis of the plasma parameters inferred from the classical Langmuir probe procedure, from different theories of the ion current to the probe, and from measured electron energy distribution function (EEDF) obtained by double differentiation of the probe characteristic. We concluded that the plasma parameters inferred from the classical Langmuir procedure can be subjected to significant inaccuracy due to the non-Maxwellian EEDF, uncertainty of locating the plasma potential, and the arbitrariness of the ion current approximation. The plasma densities derived from the ion part of the probe characteristics diverge by as much as an order of magnitude from the density calculated according to Langmuir procedure or calculated as corresponding integral of the measured EEDF. The electron temperature extracted from the ion part is always subjected to uncertainty. Such inaccuracy is attributed to modification of the EEDF for fast electrons due to inelastic electron collisions, and to deficiencies in the existing ion current theories; i.e., unrealistic assumptions about Maxwellian EEDFs, underestimation of the ion collisions and the ion ambipolar drift, and discounting deformation of the one-dimensional structure of the region perturbed by the probe. We concluded that EEDF measurement is the single reliable probe diagnostics for the basic research and industrial applications of highly non-equilibrium gas discharge plasmas. Examples of EEDF measurements point up importance of examining the probe current derivatives in real time and reiterate significance of the equipment technical characteristics, such as high energy resolution and wide dynamic range.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fourier Spectroscopy as a Method of Investigation of Photoelectric Properties of Organic Systems

A new method of investigation of photoelectric properties of layered thin-film structures based on broadband Fourier spectroscopy exhibiting a harmonically modulated optical delay is proposed. In contrast to traditional approaches to study photoelectric properties, which are based on application of dispersive spectral devices, the proposed method allows not only simultaneously covering the ultraviolet, visible, and infrared spectral ranges, while demonstrating a wide dynamic range and high spectral resolution, but also easily varying low-frequency modulation of the action of light. The capabilities of the method are demonstrated using a polycrystalline organic heterostructure as an example. Its spectral sensitivity, speed, and specific detectivity are measured. A model and an equivalent electric circuit are proposed for explanation of the results of the measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Oscillator with wide dynamic tuning range

Two or more tandem amplifier stages, one of which is tuned, added to a circuit permit tuning an oscillator over frequency range of six decades. Oscillator operates in distributed mode for increased frequency stability. Within practical limitations, stability increases by increasing number of tuned stages.

Rippy, R. R.↗

An 802pW 93% Peak Efficiency Buck Converter with 5.5×10 6 Dynamic Range Featuring Fast DVFS and Asynchronous Load-Transient Control

Here this paper presents a buck converter with sub-nW quiescent power, high efficiency, and a wide dynamic range for ultra-low-power (ULP) IoT SoCs. To optimize the SoC power consumption, the buck converter supports fast dynamic voltage and frequency scaling (DVFS) and enables fast load-transient response (FLTR) through asynchronous control. In addition, the buck converter is fully self-contained with all features integrated on chip including a proposed adaptive deadtime controller. Fabricated in 65nm CMOS, measurement results show the buck converter has an 802pW quiescent power at 1.5V input voltage and a 93% peak efficiency. The measured dynamic range is from 0.5nW to 2.75mW, which is over 6 orders of magnitude. The measured voltage droop is 54mV for a 45nA-to-1mA load current step thanks to the asynchronous load-transient detector. The buck converter achieves the highest efficiency and widest dynamic range among all the state-of-the-art sub-nW switching voltage regulators, which makes it well suited for power management in ULP SoCs.

42 ENGINEERING↗

Sub-microsecond-resolved multi-speckle X-ray photon correlation spectroscopy with a pixel array detector

Small-angle X-ray photon correlation spectroscopy (XPCS) measurements spanning delay times from 826 ns to 52.8 s were performed using a photon-counting pixel array detector with a dynamic range of 0–3 (2 bits). Fine resolution and a wide dynamic range of time scales was achieved by combining two modes of operation of the detector: (i) continuous mode, where data acquisition and data readout are performed in parallel with a frame acquisition time of 19.36 µs, and (ii) burst mode, where 12 frames are acquired with frame integration times of either 2.56 µs frame –1 or 826 ns frame –1 followed by 3.49 ms or 1.16 ms, respectively, for readout. The applicability of the detector for performing multi-speckle XPCS was demonstrated by measuring the Brownian dynamics of 10 nm-radius gold and 57 nm-radius silica colloids in water at room temperature. In addition, the capability of the detector to faithfully record one- and two-photon counts was examined by comparing the statistical distribution of photon counts with expected probabilities from the negative binomial distribution. In conclusion, it was found that in burst mode the ratio of 2s to 1s is markedly smaller than predicted and that this is attributable to pixel-response dead-time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Wide-Field Imaging Using Nitrogen Vacancies

Nitrogen vacancies in bulk diamonds and nanodiamonds can be used to sense temperature, pressure, electromagnetic fields, and pH. Unfortunately, conventional sensing techniques use gated detection and confocal imaging, limiting the measurement sensitivity and precluding wide-field imaging. Conversely, the present sensing techniques do not require gated detection or confocal imaging and can therefore be used to image temperature, pressure, electromagnetic fields, and pH over wide fields of view. In some cases, wide-field imaging supports spatial localization of the NVs to precisions at or below the diffraction limit. Moreover, the measurement range can extend over extremely wide dynamic range at very high sensitivity.

Englund, Dirk Robert↗

Lidar System for Airborne Measurement of Clouds and Aerosols

A lidar system for measuring optical properties of clouds and aerosols at three wavelengths is depicted. The laser transmitter is based on a Nd:YVO4 laser crystal pumped by light coupled to the crystal via optical fibers from laser diodes that are located away from the crystal to aid in dissipating the heat generated in the diodes and their drive circuits. The output of the Nd:YVO4 crystal has a wavelength of 1064 nm, and is made to pass through frequency-doubling and frequency-tripling crystals. As a result, the net laser output is a collinear superposition of beams at wavelengths of 1064, 532, and 355 nm. The laser operates at a pulse-repetition rate of 5 kHz, emitting per-pulse energies of 50 microJ at 1064 nm, 25 microJ at 532 nm and 50 microJ at 355 nm. An important feature of this system is an integrating sphere located between the laser output and the laser beam expander lenses. The integrating sphere collects light scattered from the lenses. Three energy-monitor detectors are located at ports inside the integrating sphere. Each of these detectors is equipped with filters such that the laser output energy is measured independently for each wavelength. The laser output energy is measured on each pulse to enable the most accurate calibration possible. The 1064-nm and 532-nm photodetectors are, more specifically, single photon-counting modules (SPCMs). When used at 1064 nm, these detectors have approximately 3% quantum efficiency and low thermal noise (fewer than 200 counts per second). When used at 532 nm, the SPCMs have quantum efficiency of about 60%. The photodetector for the 355-nm channel is a photon-counting photomultiplier tube having a quantum efficiency of about 20%. The use of photon-counting detectors is made feasible by the low laser pulse energy. The main advantage of photon-counting is ease of inversion of data without need for complicated calibration schemes like those necessary for analog detectors. The disadvantage of photon-counting detectors is that they inherently have narrow dynamic ranges. However, by using photon-counting detectors along with a high-repetition rate laser, it is possible to obtain wide dynamic range through accumulation of counts over many pulses.

McGill, Matthew↗

The Design and Operation of TMI, a Mechanically-Scanning, Multi-Frequency Microwave Radiometer for the Tropical Rainfall Measurements Mission

The Tropical Rainfall Measurement Mission (TRMM), a joint mission between the U.S. NASA and the Japans NASDA (National Space Development Agency), was successfully launched in November of 1997. On board of the TRMM satellite are two major microwave sensors, a real-aperture radar operating at 13.8 GHz, called the Precipitation Radar (PR), and a microwave radiometer system called TRMM Microwave Imager (TMI). The TMI contains five frequencies, ranging from 10.7 to 85 GHz, is designed to cover a wide dynamic range of rain intensities. The TMI measures the rain from the emission properties while the PR's measurement is based on the scattering of the hydrometeor. The two instruments aboard the same platform provide a complementary and synergistic measurement of precipitation. This paper will focus primarily on the TMI. The advent of microwave sensor technology in recent years, the addition of a new frequency (at 10.7 GHz), as well as the mission design, have enabled the TMI to be a superior instrument for the precipitation measurement. We will provide a description of the instrument together with some of its the design rationales and practical hardware implementation. We will also show the performance of TMI aboard the TRMM and some examples of its data.

Shiue, James C.↗

A new high-speed solar radio spectrograph for meter and decameter wavelengths

The design and characteristics of a high resolution, digital solar spectrograph are discussed. The spectrometer operates in the 10 to 80 MHz range. The primary considerations in the design of the spectrograph were: (1) optimun sensitivity, (2) wide dynamic range, (3) flexibility in time and frequency resolution, and (4) modern data handling techniques with a simple computer interface.

Mosier, S. R.↗

Measurement report: The Fifth International Workshop on Ice Nucleation phase 1 (FIN-01): intercomparison of single-particle mass spectrometers

Knowledge of the chemical composition and mixing state of aerosols at a single-particle level is critical for gaining insights into atmospheric processes. One common tool to make these measurements is single-particle mass spectrometry. There remains a need to compare the performance of different single-particle mass spectrometers (SPMSs). An intercomparison of SPMSs was conducted at the Aerosol Interaction and Dynamics in the Atmosphere (AIDA) chamber at the Karlsruhe Institute of Technology (KIT) in November 2014, as part of the first phase of the Fifth International Workshop on Ice Nucleation (FIN-01). In this paper we compare size distributions and mass spectra of atmospherically relevant particle types measured by five SPMSs. These include different minerals, desert and soil dusts, soot, bioaerosol (Snomax; protein granule), secondary organic aerosol (SOA), and SOA-coated mineral particles. Most SPMSs reported similar vacuum aerodynamic diameter (d va ) within typical instrumental ranges from ~100–200 nm (lower limit) to ~2–3 µm (upper limit). In general, all SPMSs exhibited a wide dynamic range (up to ~10 3 ) and high signal-to-noise ratio (up to ~10 4 ) in mass spectra. Common spectral features with small diversities in mass spectra were found with high average Pearson's correlation coefficients, i.e., for average positive spectra r avg-pos =0.74 ± 0.12 and average negative spectra r avg-neg =0.67 ± 0.22. We found that instrument-specific detection efficiency (DE) was more dependent on particle size than particle type, and particle identification favored the use of bipolar, rather than monopolar, instruments. Particle classification from “blind experiments” showed that all instruments differentiated SOA, soot, and soil dust and detected subtle changes in the particle internal mixing but had difficulties differentiating among specific mineral types and dusts. This study helps to further understand the capabilities and limitations of the single-particle mass spectrometry technique in general and the specific performance of the instrument in characterizing atmospheric aerosol particles.

54 ENVIRONMENTAL SCIENCES↗

High-dynamic-range coherent diffractive imaging: ptychography using the mixed-mode pixel array detector

Coherent (X-ray) diffractive imaging (CDI) is an increasingly popular form of X-ray microscopy, mainly due to its potential to produce high-resolution images and the lack of an objective lens between the sample and its corresponding imaging detector. One challenge, however, is that very high dynamic range diffraction data must be collected to produce both quantitative and high-resolution images. In this work, hard X-ray ptychographic coherent diffractive imaging has been performed at the P10 beamline of the PETRA III synchrotron to demonstrate the potential of a very wide dynamic range imaging X-ray detector (the Mixed-Mode Pixel Array Detector, or MM-PAD). The detector is capable of single photon detection, detecting fluxes exceeding 1 × 10 8 8-keV photons pixel -1 s -1 , and framing at 1 kHz. A ptychographic reconstruction was performed using a peak focal intensity on the order of 1 × 10 10 photons µm -2 s -1 within an area of approximately 325 nm × 603 nm. This was done without need of a beam stop and with a very modest attenuation, while `still' images of the empty beam far-field intensity were recorded without any attenuation. The treatment of the detector frames and CDI methodology for reconstruction of non-sensitive detector regions, partially also extending the active detector area, are described.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

All-digital phase-lock loops for noise-free signals

Bit-synchronizers utilize all-digital phase-lock loops that are referenced to a high frequency digital clock. Phase-lock loop of first design acquires frequency within nominal range and tracks phase; second design is modified for random binary data by addition of simple transition detector; and third design acquires frequency over wide dynamic range.

Anderson, T. O.↗

Distribution of dark and luminous mass in galaxies

A uniform scale relation between dark and baryonic matter is observed in galaxies over a broad range of physical parameter space. The ratio of dark to baryonic mass is found to increase proportionately with radial distance in observational data spanning a wide dynamic range of morphological type, rotation velocity, radius, surface density, and mass. This close relation between dark and baryonic mass poses a fine-tuning problem for galaxy formation models. Such a uniform scale relation, extending from the inner galactic region to the outermost kinematic data point, may play a role in clarifying the dark matter phenomenon.

79 ASTRONOMY AND ASTROPHYSICS↗

Electron calibration of instrumentation for low energy, high intensity particle measurements at Mercury

Unique identification of the high intensity, impulsively accelerated charged particle fluxes discovered during Mariner 10's first encounter with Mercury (March 1974) requires a detailed knowledge of the responses of the two University of Chicago charged particle telescopes to low energy fluxes over a wide dynamic range of flux levels. The results of detailed analyses show that these telescopes can separate and identify unambiguously the presence of electron and proton fluxes for a wide range of electron spectra and intensities in the relevant overall range of about 30 keV to 2 MeV.

Christon, S. P.↗

Three-Dimensional Venturi Sensor for Measuring Extreme Winds

A three-dimensional (3D) Venturi sensor is being developed as a compact, rugged means of measuring wind vectors having magnitudes of as much as 300 mph (134 m/s). This sensor also incorporates auxiliary sensors for measuring temperature from -40 to +120 F (-40 to +49 C), relative humidity from 0 to 100 percent, and atmospheric pressure from 846 to 1,084 millibar (85 to 108 kPa). Conventional cup-and-vane anemometers are highly susceptible to damage by both high wind forces and debris, due to their moving parts and large profiles. In addition, they exhibit slow recovery times contributing to an inaccurately high average-speed reading. Ultrasonic and hot-wire anemometers overcome some of the disadvantages of the cup and-vane anemometers, but they have other disadvantageous features, including limited dynamic range and susceptibility to errors caused by external acoustic noise and rain. In contrast, the novel 3D Venturi sensor is less vulnerable to wind damage because of its smaller profile and ruggedness. Since the sensor has no moving parts, it provides increased reliability and lower maintenance costs. It has faster response and recovery times to changing wind conditions than traditional systems. In addition, it offers wide dynamic range and is expected to be relatively insensitive to rain and acoustic energy. The Venturi effect in this sensor is achieved by the mirrored double-inflection curve, which is then rotated 360 to create the desired detection surfaces. The curve is optimized to provide a good balance of pressure difference between sensor ports and overall maximum fluid velocity while in the shape. Four posts are used to separate the two shapes, and their size and location were chosen to minimize effects on the pressure measurements. The 3D Venturi sensor has smart software algorithms to map the wind pressure exerted on the surfaces of the design. Using Bernoulli's equation, the speed of the wind is calculated from the differences among the pressure readings at the various ports. The direction of the wind is calculated from the spatial distribution and magnitude of the pressure readings. All of the pressure port sizes and locations have been optimized to minimize measurement errors and to reside in areas demonstrating a stable pressure reading proportional to the velocity range.

Zysko, Jan A.↗

Infrared photon-number-resolving imager using a Skipper-CCD

Imaging in a broad light-intensity regime with a high signal-to-noise ratio is a key capability in fields as diverse as Quantum Metrology and Astronomy. Achieving high signal-to-noise ratios in quantum imaging leads to surpassing the classical limit in parameter estimation. In astronomical detection, the search for habitable exoplanets demands imaging in the infrared its atmospheres looking for biosignatures. These optical applications are hampered by detection noise, which critically limits their potential, and thus demands photon-number and spatial resolution detectors. Here we report an imaging device in the infrared wavelength range able to arbitrarily reduce the readout noise. We built a Measured Exposure Skipper-CCD Sensor Instrument equipped with a thick back-illuminated sensor, with photon-number-resolving capability in a wide dynamic range, spatial resolution, high quantum efficiency in the near-infrared and ultra-low dark counts. This device allows us to image objects in a broad range of intensities within the same frame and, by reducing the readout noise to less than 0.2e$^-$, to distinguish even those shapes with less than two photons per pixel, unveiling what was previously hidden in the noise. These results pave the way for building high-standard infrared imagers based on Skipper-CCDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Programmable random interval generator

Random pulse generator can supply constant-amplitude randomly distributed pulses with average rate ranging from a few counts per second to more than one million counts per second. Generator requires no high-voltage power supply or any special thermal cooling apparatus. Device is uniquely versatile and provides wide dynamic range of operation.

Lindsey, R. S., Jr.↗