Search NASA⌕ Search

SEARCH · Search NASA

Results for “Wind turbine generator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Demonstration of a fault impact reduction control module for wind turbines

Abstract. Traditionally, wind turbines in distributed applications make control decisions as isolated systems. They generally provide maximum power output during operation and manage internal faults with little consideration of the rest of the power system. Although fault detection and tolerance schemes are widely researched and implemented, controls to ameliorate such faults are uncommon in research and industry. The rapid shutdown of a wind turbine in a large transmission-connected wind plant will have a minimal impact on a large power system, but in a microgrid or isolated grid context the abrupt loss of a single wind turbine may cause grid instability and high stress on the system. This paper demonstrates a fault impact reduction control (FIRC) module for a wind turbine, which implements wider warning thresholds around fault thresholds. When the turbine crosses a warning threshold, the controller sends its predicted action to the grid controller, which facilitates the grid operator’s response to a potential wind turbine fault and then takes appropriate action to ameliorate the fault. Various test cases demonstrate the controller action under a variety of faults, and various scenarios demonstrate the grid benefit of an FIRC in both microgrid- and grid-connected contexts. The FIRC maximizes wind turbine generation and eases generation transition under a variety of fault scenarios. The FIRC module is easy to integrate with most existing controllers, just requiring derate capability, and can be easily modified to include the various warnings and thresholds that the user desires. This analysis is mainly performed in a MATLAB-Simulink-based research wind turbine model and is also implemented in the existing LabVIEW-based controller of the same research turbine at NREL.

17 WIND ENERGY↗

2020 Component Innovation Awardee: Windurance LLC

Currently, there is no wind system power-conversion component available to wind turbine OEMs that is certified to applicable standards for use in the U.S. distributed wind energy market. Off-the-shelf industrial drives have features that are not needed by distributed wind OEMs and lack other features that would be valuable for the operation and control of wind turbine generating systems. In addition to adding costs for OEMs, these industrial drives increase uncertainty and risk for project developers and prospective owners. All of this presents barriers and increases costs for the development of distributed wind in the United States. With funding from CIP, Windurance plans to develop an industry-specific power-conversion component that will offer application-specific features at lower cost for distributed wind OEMs.

CIP↗

Modelling and control coordination scheme of a wind‐to‐hydrogen set for future renewable‐based power systems

New challenges regarding system stability and efficiency arise when power systems operate with a high penetration level of inverter‐based renewable sources (IBRSs) and few synchronous generators. Since IBRSs have been on the rise, to secure the stable operation of future power systems, IBRSs will be required to support systems without having to rely on remaining synchronous generators. Also, to efficiently manage the uncertainty of renewable production, power‐to‐gas technology can provide the required flexibility. This study proposes modelling and a control coordination scheme (CCS) of a wind‐to‐hydrogen (W2H) set to optimise electricity production from a variable‐speed wind turbine generator (WTG) while helping balance between supply and demand in a system. To achieve this, a grid‐forming (GFM) inverter‐based WTG is modelled and a set of electrolyser and fuel cell is integrated at the DC circuit of a GFM‐WTG to be coordinated. Furthermore, the CCS offers an opportunity to reduce the investment cost for deploying a W2H set by utilising the control capabilities of a WTG and reducing the need for an additional device. The performance of the proposed W2H set with the CCS was verified considering the variations in system load and wind speed by using Power System Computer Aided Design (PSCAD)/ElectroMagnetic Transients including Direct Current (EMTDC).

Kim, Jinho↗

Modeling and Power-Hardware-in-the-Loop Validation of Synchronous Wind: An Inverterless Grid-Forming Wind Power Plant

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators (WTGs) has attracted substantial attention in power systems research; however, the limited overcurrent capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also known as a Type-5 WTG, offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high integration levels of renewable generation. A Type-5 WTG interfaces with the electric grid via a synchronous generator driven by a variable-speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation, and the generator shaft remains synchronous to the grid. This paper develops and tests a high-fidelity model of a Type-5 WTG in a power-hardware-in-the-loop (PHIL) testing environment. The PHIL demonstration shows that a Type-5 WTG inherently behaves as a GFM unit and can obtain similar performance in terms of power responses, wind rotor dynamics, and efficiency compared to a Type-3 WTG in high-wind conditions. The developed model provides further insight into how Type-5 WTGs can benefit the smooth transition to power systems with high integration levels of inverter-based resources.

grid strength↗

A Model-Free Frequency Control Approach for Diesel-Wind Powered Microgrids

Islanded microgrids usually consist of diesel generators and renewable energy sources (RES) to reduce the operating cost. Such microgrids have shown values for powering remote locations, but introduced unique challenges for frequency control of the grid due to the variability of renewable energy as well as the decoupled design of converter interface in RES. So, supportive control in RES becomes mandatory in such networks. This paper proposes a new dynamic control strategy, based on model-free control (MFC) approach, to support the primary frequency control of such islanded microgrids. The practical values of MFC have been discussed in various domains due to its control capability without modeling procedure and its efficient computation. In particular, we consider the diesel-wind system and the proposed MFC strategy is utilized as an online controller, which computes supplementary control signals for the rotor-side converter of the available wind turbine generators (WTGs). The calculated input signals allow WTGs to respond to frequency variations and improve the frequency response of the system. The controller is implemented and verified using the modified IEEE 33-bus full nonlinear model of the three-phase diesel-wind system in Simulink. Simulation results show the enhanced frequency response from the MFC strategy.

Park, Byungkwon↗

Impedance sources (Z sources) with inherent fault protection for resilient and fire-free electricity grids

Modern societies would not survive without electricity and at the same time electrical faults could cause and have caused many catastrophes—mainly deadly fires—to our societies. There are two types of electricity sources: the voltage source such as generators, charged batteries and capacitors, and the current source such as charged inductors, current-regulated rectifiers, and superconducting magnetic energy storage. An “ideal” voltage source—that is often-sought-or-intentionally engineered—generates a constant voltage irrespective of its load current, and an “ideal” current source injects a constant current irrespective of its load voltage. However, two problems exist: (1) voltage or current sources do not represent many emerging natural/renewable energy sources such as wind turbine generators, photovoltaic cells, and fuel cells, whose output voltage and current are strongly dependent on each other, and (2) a short-circuit fault to an artificially-made and controlled “ideal” voltage source or an open-circuit fault to an “ideal” current source can cause catastrophic failures of the source itself and its surrounding circuits due to large (theoretically infinite) short-circuit current or open-circuit voltage. Here we introduce an impedance source concept to represent, characterize, and model those electricity sources whose output voltage and current are strongly dependent on each other. First, we found that many electric sources with no feedback (or active) control of their output voltage and/or current are a natural impedance source with inherent fault protection at short-circuit or open-circuit faults. Second, any electrical source can be artificially controlled to mimic a natural impedance source. Finally, we show how to apply natural impedance sources and nature-mimicking artificially-controlled sources to the electricity grid—the most complex machine ever made by human beings—to realize electricity grids that are naturally stable, self-protected against electrical faults, and resilient to natural and human-made events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Boundary Topology Optimization Approach for Lightweighting Electric Machines Inspired by Additive Manufacturing

Minimizing the mass in electric machines while maintaining superior performance has become a new requirement for the advancement of drivetrains used in wind energy and electric mobility. Topology optimization for light-weighting electric machines using traditional approaches typically explore a restricted design space allowed by standard parametrizable geometry and manufacturing, while advanced methods like cell-based density approaches suffer from a lack of robust manufacturability constraints during the optimization process. To overcome these drawbacks, we explore a grid-independent, boundary TO where the outer shape of the magnet is parameterized using Bezier curves. We conduct a design of experiments (DOE) to study the effect of different magnet shapes on machine performance by varying the control points on the Bezier curves. A machine-learning based surrogate model is constructed using the data from the DOE to quantify the relationship between the control points, air-gap torque and mass. The control points are then optimized to maximize the torque density. The approach is used for minimizing electrical steel mass in the IEA-15MW radial flux direct-drive wind turbine generator. The free-from boundary TO resulted in smooth and concise shapes that can be easily additively manufactured with upto 20-ton reduction in electrical steel mass.

additive manufacturing↗

A New Shape Optimization Approach for Lightweighting Electric Machines Inspired by Additive Manufacturing

Minimizing the mass in electric machines while maintaining superior performance is a new requirement for the advancement of drivetrains used in wind energy and electric mobility. Topology optimization (TO) for lightweighting electric machines using traditional approaches typically explores a restricted design space allowed by standard parametrizable geometry and manufacturing, while advanced methods, such as cell-based density approaches, suffer from a lack of robust manufacturability constraints during the optimization process. To overcome these drawbacks, we explore a grid-independent, boundary optimization where the outer shape of the magnet is parameterized using Bezier curves. We conduct a design of experiments (DOE) to study the effect of different magnet shapes on machine performance by varying the control points on the Bezier curves. A machine-learning-based surrogate model is constructed using the data from the DOE to quantify the relationship between the control points, air-gap torque, and mass. The control points are then optimized to maximize the torque density. The approach is used for minimizing electrical steel mass in the International Energy Agency (IEA) 15-MW radial flux direct-drive wind turbine generator. The new approach to shape optimization resulted in smooth and concise shapes that can be easily additively manufactured with up to a 20-ton reduction in electrical steel mass.

additive manufacturing↗

A New Shape Optimization Approach for Lightweighting Electric Machines Inspired by Additive Manufacturing: Preprint

Minimizing the mass in electric machines while maintaining superior performance is a new requirement for the advancement of drivetrains used in wind energy and electric mobility. Topology optimization (TO) for lightweighting electric machines using traditional approaches typically explores a restricted design space allowed by standard parametrizable geometry and manufacturing, while advanced methods, such as cell-based density approaches, suffer from a lack of robust manufacturability constraints during the optimization process. To overcome these drawbacks, we explore a grid-independent, boundary TO where the outer shape of the magnet is parameterized using Bezier curves. We conduct a design of experiments (DOE) to study the effect of different magnet shapes on machine performance by varying the control points on the Bezier curves. A machine-learning-based surrogate model is constructed using the data from the DOE to quantify the relationship between the control points, air-gap torque, and mass. The control points are then optimized to maximize the torque density. The approach is used for minimizing electrical steel mass in the International Energy Agency (IEA) 15-MW radial flux direct-drive wind turbine generator. The free-form boundary TO resulted in smooth and concise shapes that can be easily additively manufactured with up to a 20-ton reduction in electrical steel mass.

additive manufacturing↗

Environmental Effects Assessment for Proposed Offshore Wind Farm off the Coast of Grays Harbor, Washington

Grays Harbor Wind LLC (GHW) is proposing to develop a floating offshore wind farm offshore of west Grays Harbor County, Washington (Grays Harbor). The proposed GHW Offshore Wind Project (Project) would entail construction, installation and operation of a 1,000-megawatt (MW) offshore wind farm consisting of approximately 75 floating units, each containing a floating foundation and wind turbine generator (WTG). The Project location is approximately 25 miles (21.7 nautical miles [nmi]) offshore west of Grays Harbor, at waters depths of 360 to 700 feet. The Pacific Northwest National Laboratory (PNNL) was contracted by Herrera Environmental Consultants, Inc. on behalf of GHW to carry out this preliminary scoping study to evaluate baseline conditions and potential effects on fish and marine mammals from development and operation of a floating offshore wind farm installed within a designated area off the coast of Washington1. Floating offshore wind units installed in an ocean environment as part of the Project would interact with marine wildlife. This Study report provides an initial data aggregation and analysis, using publicly available data, of the Project effects, both negative and positive, on the marine environment. The scope of this assessment is limited by the fact that the Project development is presently at the conceptual level. Data on marine organisms were aggregated and evaluated; however seabirds were evaluated by Herrera Environmental Consulting and, along with bats, were not included in the scope of this study. Significant additional work is necessary to characterize ocean, seafloor, and environmental conditions; select appropriate floating offshore wind technologies; identify construction methods and locations; and assess facility locations, including electrical interconnection. Data aggregation and analysis of seabirds and bats is also needed. Evaluation of the full range of potential environmental effects would be conducted following an award of a lease from the Bureau of Ocean Energy Management (BOEM) as part of the leasing, National Environmental Policy Act (NEPA)/State Environmental Policy Act (SEPA) environmental review and permitting processes. While this initial data aggregation and analysis uses best available public scientific information and current assumptions about the Project configuration, the effects discussed herein are based on the status of review to-date and may change as Project-specific details are developed.

17 WIND ENERGY↗

BIL GRID-READY WIND: Reliable and Economical Grid Services Design, Implementation, and Demonstration at the Great Pathfinder Wind Power Plant

The GRID-READY WIND project aimed to demonstrate the ability of utility-scale wind power plants (WPPs) to deliver traditional and emerging grid services (GSs) in both grid-following (GFL) and grid-forming (GFM) modes through a centralized control framework, supplemented by local control adjustments at the wind turbine generator as needed. Throughout the project, the team offered recommendations on how the grid services demonstrated with WPPs could be applied to other inverter-based resources (IBRs), such as photovoltaic (PV) systems and battery energy storage systems (BESS), while considering the unique dynamics of these resources arising from their energy generation characteristics. The project sought to enhance the confidence of system operators (SOs) and planners in utilizing WPPs, alongside other IBRs such as PV plants and BESS, to provide essential grid services over extended periods under diverse operating conditions, thereby supporting their integration into the bulk power system.

17 WIND ENERGY↗

Nonlinear Virtual Inertia Control of WTGs for Enhancing Primary Frequency Response and Suppressing Drivetrain Torsional Oscillations

Virtual inertia controllers (VICs) for wind turbine generators (WTGs) have been recently developed to compensate the reduction of inertia in power systems. However, VICs can induce drivetrain torsional oscillations of WTGs. This paper addresses this issue and develops a novel nonlinear VIC based on objective holographic feedback theory and the definition of a completely controllable system of Brunovsky type. Simulation results under various scenarios demonstrate that the proposed technique outperforms existing VICs in terms of enhancement of system frequency nadir, suppression of WTG drivetrain torsional oscillations, fast and smooth recovery of WTG rotor speed to the original maximum power point (MPP) before the disturbance as well as preventing secondary frequency dip caused by traditional VIC. The proposed technique is also able to adaptively coordinate multiple WTGs to enhance the frequency support and the dynamic performance of each WTG.

24 POWER TRANSMISSION AND DISTRIBUTION↗

2023 Critical Materials Strategy

The global effort to curb carbon emissions is accelerating demand for clean energy technologies and the materials they rely on. Demand for these materials will only continue to grow, especially as some nations aim to achieve net zero emissions by 2050. While some major materials like steel, copper, and aluminum are already powering the fossil fuel economy, others are more minor materials with potential supply risks. These risks could jeopardize the ability to reduce greenhouse gas emissions within the desirable timeframe to avoid significant climate change. In some cases, it may be necessary to take action to improve the resilience of material supply chains and mitigate supply risks. Understanding the importance of individual materials to clean energy and the supply risks associated with them is necessary to identify which materials may serve as potential roadblocks to a clean energy future. The U.S. Department of Energy (DOE) issued a series of 13 supply chain deep dive assessment reports on various energy technologies in 2022 in response to President Biden’s Executive Order on America’s Supply Chains (E.O. 14017). These reports emphasized that supply chain bottlenecks can occur at any stage of the value chain from mining and refining to component and even sub-system manufacturing. The bottlenecks are a combination of factors such as material availability, equipment availability, work force availability and quality, logistics, regulatory framework, and market conditions. These bottlenecks were worsened during the global Covid-19 pandemic. Its lingering impacts have hindered capacity expansion for material supply chains and prevented product lead-time recovery. One approach to reduce supply chain risks for the United States is to have a strong domestic manufacturing sector with a diverse set of producers. Boosting responsible domestic production would require leveraging the latest science not only in material extraction but also in developing substitutes, recycling, reuse, and remanufacturing. This report is an updated analysis of previous Critical Materials Strategy (CMS) reports published by the DOE in 2010, 2011, and 2019 based on national and global priorities, technology advancement, and technology adoption trends. Like the CMS reports, this analysis presents the results of a formal material criticality assessment to identify which materials are critical to the continued deployment of clean energy technologies globally. The analysis in this report leveraged the DOE supply chain deep dive assessments to develop the initial list of materials to evaluate. This DOE Critical Materials Assessment (CMA) is conducted independently of criticality assessments performed by other U.S. government agencies, such as that conducted by the U.S. Geological Survey (USGS). This analysis complements the USGS critical minerals determination in three aspects. First, the DOE assessment is performed from a global perspective, while the USGS analysis focusses on the importance of minerals to the U.S. economy. Second, this report focuses on the importance of materials to clean energy technologies, rather than to the economy in general. Lastly, this study is forward looking to 2035 based on clean energy deployment scenarios, whereas the USGS assessment is retrospective. Materials evaluated in this report that do not appear in the USGS Critical Minerals List include copper, uranium, electrical steel, and SiC. A draft version of this report received ~80 public comments related to supporting data and methodological improvement. Those comments have been incorporated as much as possible where appropriate. Highlights of findings from this 2023 CMA include: Rare earth materials (neodymium, praseodymium, dysprosium, and terbium) used in magnets in electric vehicle (EV) motors and wind turbine generators continue to be critical. While dysprosium (Dy) and terbium (Tb) are both heavy rare earth elements that serve the same function in magnets, the criticality of Tb is slightly lower than that for Dy in the short term due to the widespread use of Dy in high-grade magnets and Tb’s present role as a substitute. Similarly, praseodymium (Pr) is critical in the medium term but only near critical in the short term because it is more substitutable in magnets than neodymium (Nd); Materials used in batteries for EVs and stationary storage are now considered to be critical. While cobalt (Co) was found to be critical in this and previous reports, lithium (Li) becomes critical in the medium term due to its broader use in various battery chemistries and the rampant growth of the EV industry. Natural graphite is a new addition in this assessment and is also found to be critical; Platinum group metals used in hydrogen electrolyzers, such as platinum (Pr) and iridium (Ir), are critical due to an increased focus on hydrogen technologies to achieve net zero carbon emissions, while those used in catalytic converters, such as rhodium (Rh) and palladium (Pd), were screened out due to the decreased importance of catalytic converters in the medium term; Gallium (Ga) continues to be critical due to its use in light-emitting diodes (LEDs). In addition, the use of Ga has increased in magnet manufacturing and in semiconductor in forms such as gallium arsenide (GaAs) or gallium nitride (GaN); Major materials like Aluminum (Al), copper (Cu), nickel (Ni), and silicon (Si) move from noncritical in the short term to near critical in the medium term due to their importance in electrification; Electrical steel is near critical due to its use in transformers for the grid and electric motors in EVs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Design and Evaluation of a Model-Free Frequency Control Strategy in Islanded Microgrids with Power-Hardware-in-the-Loop Testing

The deterioration of inertial and primary frequency response of islanded microgrids has been a crucial issue for the proper operation of such microgrids. Several approaches, including inertia emulation strategies, have been proposed to improve the primary frequency response. However, the demonstrations of most inertia emulation research works are based on simulation-only testing which hinder their applicability in the field. In this paper, a novel model-free control (MFC) strategy for frequency response support in a diesel-wind microgrid system is presented, and it is tested for evaluation using a power-hardware-in-the-Ioop (PHIL) platform. The PHIL testing is one step closer to field testing since it allows real-time verification and accounts for the nonlinear grid dynamics, noise, and time delays that are usually ignored in simulation-only environments. The proposed MFC strategy is fully distributed, has low computational requirements, and can be easily implemented in resource constrained devices such as smart inverters. A PHIL microgrid platform consisting of two type-3 wind turbine generators and one diesel generator is used to test the proposed MFC strategy.

Ferrari Maglia, Max↗

GeneratorSE.jl

SAND2026-22941O GeneratorSE.jl is a Julia software package for analytical sizing of variable-speed wind turbine generators. It translates and maintains generator sizing methods from the NREL WISDEM GeneratorSE framework in a Julia package form. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Michelen Strofer, Carlos [Sandia National Lab. (SN↗

Fragility Functions Resource Report: Documented Sources for Electricity and Water Resilience Valuation

Fragility curves provide the vulnerability between hazard intensity and an asset. Federal installations may include many different electricity and water infrastructure types (or assets) such as generators, wind turbines, solar PV, switch yards, substations and power lines as well as water distribution systems that could be affected by different hazards. The vulnerability of each asset is a function of its age, type of materials and maintenance. In addition, the vulnerability changes with the hazards intensity and has a probability distribution function associated with it. The fragility functions are used in conjunction with hazard probability and consequence valuations to determine the values at risk for examination of investment grade analyses of alternative mitigation strategies. This document provides examples of fragility functions and links to their sources for different electricity and water infrastructure assets by hazard type.

24 POWER TRANSMISSION AND DISTRIBUTION↗

AL-CRADA-2025-01 Final Report: American-Made Wind Turbine Materials Recycling Prize Accelerate! Phase 2

This report summarizes the Phase 2 achievements of the Wind Turbine Materials Recycling Prize project led by Critical Materials Recycling (CMR) in partnership with Ames National Laboratory. The team demonstrated the technical feasibility and economic viability of recovering and reusing rare-earth Nd-Fe-B magnets from end-of-life (EOL) wind turbine generators. Through mechanical disassembly, demagnetization, and precision processing, magnets were harvested and characterized to assess structural, compositional, and magnetic properties. Results showed that recovered magnets performed on par with commercial-grade counterparts, enabling their integration into actuator and motor prototypes without redesign. System-level modeling and finite-element simulations validated operational performance, while Life Cycle Cost (LCC) analysis revealed up to 20% material cost savings and 2–3% reductions in overall motor system costs. Life Cycle Assessment (LCA) further confirmed substantial environmental benefits, including a ~94% reduction in global warming potential relative to virgin magnet production. The project’s success was enabled by a tightly integrated partnership between industry and national lab experts, illustrating a viable path for domestic magnet-to-magnet recycling. These findings support a scalable, circular solution for rare-earth material recovery, reducing dependence on imported critical minerals and advancing sustainable clean energy technologies.

Lograsso, Thomas [Ames Laboratory (AMES), Ames, IA↗

Hardware-in-the-loop Testing of Signal Temporal Logic Frequency Control in a Microgrid

This paper presents a hardware-in-the-loop (HITL) testing and lessons learned for a signal temporal logic (STL) frequency control in a microgrid setting. In contrast to most, if not all, traditional control mechanisms, the STL control allows for including temporal constraints in the control formulation to handle sophisticated specifications from grid codes and protection relays. This feature provides richer descriptions of control specifications to address both magnitude and time simultaneously, hence a valuable tool for power system operation and control. An ultra-low voltage (24V) HITL microgrid platform consisting of two type-3 wind turbine generators and one diesel generator is used to test the proposed STL frequency control. In experimental case studies, we demonstrate that the HITL frequency responses closely match the simulated ones and strictly satisfy the designed STL control specifications.

Ferrari Maglia, Max↗