Search NASA⌕ Search

SEARCH · Search NASA

Results for “X-ray Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Measurement of X-ray scattering by optical surfaces

Optical surfaces built for X-ray telescopes are made to reflect very short wavelengths that range in magnitude from 2 to 100 angstroms. Minor irregularities or contamination on sufrace of any telescope mirror can affect quality of optical image. Apparatus checks reflection of optical surfaces; scattering of X-rays is measured with angular accuracy of one arc-second.

Wriston, R. S.↗

Glancing incidence optics for X-ray and ultraviolet astronomy.

Glancing incidence telescopes of the kind first described by Wolter have now been physically realized, so that it is possible to obtain high-resolution images of celestial objects at all wavelengths greater than about 3 A. The GSFC-MSFC X-ray telescope for the Apollo telescope mount uses Wolter type 1 optics and is capable of forming images of the sun in the 8-70 A region with spatial resolution of the order of one arc second. The GSFC extreme ultraviolet spectroheliometer for OSO H uses type 2 optics and can obtain images of the sun in spectral lines in the 170-400 A region with a spatial resolution of about ten arc seconds. Theoretical (ray trace) and laboratory data on these systems are presented.

Underwood, J. H.↗

Computer enhancement of radiographs

Examination of three relevant noise processes and the image degradation associated with Marshall Space Flight Center's (MSFC) X-ray/scanning system was conducted for application to computer enhancement of radiographs using MSFC's digital filtering techniques. Graininess of type M, R single coat and R double coat X-ray films was quantified as a function of density level using root-mean-square (RMS) granularity. Quantum mottle (including film grain) was quantified as a function of the above film types, exposure level, specimen material and thickness, and film density using RMS granularity and power spectral density (PSD). For various neutral-density levels the scanning device used in digital conversion of radiographs was examined for noise characteristics which were quantified by RMS granularity and PSD. Image degradation of the entire pre-enhancement system (MG-150 X-ray device; film; and optronics scanner) was measured using edge targets to generate modulation transfer functions (MTF). The four parameters were examined as a function of scanning aperture sizes of approximately 12.5 25 and 50 microns.

Dekaney, A.↗

Design and mathematical analysis of a three-mirror X-ray telescope based on ATM S-056 X-ray telescope hardware

The mathematical design of the aspheric third mirror for the three-mirror X-ray telescope (TMXRT) is presented, along with the imaging characteristics of the telescope obtained by a ray trace analysis. The present design effort has been directed entirely toward obtaining an aspheric third mirror which will be compatible with existing S-056 paraboloidal-hyperboloidal mirrors. This compatability will facilitate the construction of a prototype model of the TMXRT, since it will only be necessary to fabricate one new mirror in order to obtain a working model.

Foreman, J. W., Jr.↗

Thermochemical Stability of Ca2Yb8(SiO4)6O2 Apatite in Presence of Molten Calcium-Magnesium-Aluminosilicate (CMAS)

Thermochemical stability of ytterbium silicon oxyapatite Ca 2 Yb 8 (SiO 4 ) 6 O 2 (CYbS) in the presence of molten calcium-magnesium aluminosilicate (CMAS) has been investigated at elevated temperatures for consideration as a thermal and environmental barrier coating (T/EBC) material. CYbS apatite powder was synthesized from the constituent oxides via a solid-state reaction method. Hot-pressed apatite substrates were exposed to molten CMAS at 1200, 1300, and 1400 °C for 1, 10, and 50 h. Development of phases in the interaction region of the heat-treated specimens was monitored using scanning electron microscopy, transmission electron microscopy, high-angle annular dark-field imaging, selected area electron diffraction, and energy dispersive x-ray spectroscopy. Monoclinic cyclosilicate Ca 3 Yb 2 (Si 3 O 9 ) 2 formed from interaction of CYbS apatite with CaO in the CMAS melt at the apatite-CMAS reaction front and continued to nucleate and grow within the residual CMAS in diffusion couples annealed for 1 to 50 h at 1200 °C as well as in those heat treated at 1300 °C for 1 h. Residual CMAS was depleted of Ca when cyclosilicate was present. Dendritic wollastonite (CaSiO3) was observed within the residual CMAS in couples annealed at 1200 and 1300 °C. Ingress of molten CMAS, because of its exponential decrease in viscosity, occurred through open pores and along the grain boundaries of the apatite substrates without any detectable chemical reaction at 1300 and 1400 °C. Results of this study indicate that Ca 2 Yb 8 (SiO 4 ) 6 O 2 apatite has the potential to mitigate the CMAS corrosion up to about 1200 °C but not at higher temperatures.

Narottam P Bansal↗

Radiation-induced nickel deposits

Low cost, photographic process uses surface coating of nickel hypophosphite sensitive to X-rays and electron radiation. Exposed coated surface can be amplified to produce permanent visible image of wide tonal gradation in grays. Coating may be sodium, ammonium, or lithium hypophosphite or sodium phosphite, with nickel supplied in developer.

Marsik, S. J.↗

X-ray and gamma-ray imaging with multiple-pinhole cameras using a posteriori image synthesis.

In 1968, Dicke had suggested that multiple-pinhole camera systems would have significant advantages concerning the SNR in X-ray and gamma-ray astronomy if the multiple images could be somehow synthesized into a single image. The practical development of an image-synthesis method based on these suggestions is discussed. A formulation of the SNR gain theory which is particularly suited for dealing with the proposal by Dicke is considered. It is found that the SNR gain is by no means uniform in all X-ray astronomy applications.

Groh, G.↗

Video enhancement of X-ray and neutron radiographs

System was devised for displaying radiographs on television screen and enhancing fine detail in picture. System uses analog-computer circuits to process television signal from low-noise television camera. Enhanced images are displayed in black and white and can be controlled to vary degree of enhancement and magnification of details in either radiographic transparencies or opaque photographs.

Vary, A.↗

Digital computer processing of X-ray photos

Digital computers correct various distortions in medical and biological photographs. One of the principal methods of computer enhancement involves the use of a two-dimensional digital filter to modify the frequency spectrum of the picture. Another computer processing method is image subtraction.

Nathan, R.↗

Glancing incidence telescope for far ultraviolet and soft X-rays

Glancing-incidence telescope makes observations of distant celestial radiant bodies at wavelengths in the spectral region between 3 and 500 angstroms. The device can be used as a fore-optics system for a laboratory extreme ultraviolet spectrometer, or for the collection or imaging of thermal neutrons.

Neupert, W. M.↗

Advances in solar and cosmic X-ray astronomy - A survey of experimental techniques and observational results.

The current status of X-ray astronomy is surveyed by reviewing observational results and theoretical conclusions gained within the past two years in areas dealing with the quiet-sun, slowly-varying, and burst components of solar X-radiation and with the features of cosmic X-ray sources. Thermal and nonthermal processes responsible for a wide variety of X-ray emission mechanisms in nature are explained, and characteristics of X radiation from specific solar structures are described. Attention is given to the effects of interstellar and intergalactic matter on cosmic X-rays; the properties of galactic and extragalactic X-ray sources; and the specifications of such instruments as gas-filled ionization detectors, proportional counters, Geiger counters, scintillation detectors, photoelectric detectors, polarimeters, collimators, spectrometers, and imaging systems.

Hoover, R. B.↗

Silica reinforcement and char reactions in the Apollo heat shield.

Reactions of the silica reinforcement fiber and ablation char of the Apollo heat shield have been investigated by laboratory tests in an arc image furnace (at temperature levels up to 5000 R, pressures up to 0.7 atm, and heat flux similar to reentry) and by an actual reentry test. Microchemical analyses and X-ray diffraction studies have been made to determine the presence of SiC formation in the char. Experimental data and analytical predictions of thermal and density profiles have been compared for the ablation of virgin heat shield and precharred materials to determine the effects of SiC formation on ablation performance. In all analyses, general agreement was found between chemical composition and the thermal predictions for laboratory tests and reentry materials. In all ablated materials, SiC was formed in the front surface of the char. The highest SiC content found was 58% by weight and found in a high-pressure environment. The SiC formed was found to act as a heat sink in the ablation process and can lower the front surface temperature by 300 R.

Cagliostro, D. E.↗

Fluoroscopic tomography

A fluoroscopic tomography system capable of synthesizing body sections at a number of levels within the body has been developed. The synthesized body sections may lie either in a range of planes parallel to, tilted with respect to, skewed with respect to, or both tilted and skewed with respect to the plane of motion of the X-ray tube target. In addition, body sections can be presented which are contoured to the patient's anatomy. That is to say, they may even encompass such complex surfaces as a quadratic hyperplane. In addition, tomograms of organs in motion can be imaged.

Baily, N. A.↗

Solid state radiographic image amplifiers, part C

The contrast sensitivity of the radiographic amplifiers, both the storage type and nonstorage type, their absolute sensitivity, and the reproducibility of fabrication were investigated. The required 2-2T quality level was reached with the radiographic storage screen. The sensitivity threshold was 100 to 200 mR with 45 to 100 kV filtered X-rays. The quality level of the radiographic amplifier screen (without storage) was 4-4T; for a 6 mm (0.25 in.) thick aluminum specimen, a 1 mm (0.040 in.) diameter hole in a 0.25 mm (0.010 in.) thick penetrameter was detected. Its sensitivity threshold was 2 to 6 mR/min. The developed radiographic screens are applicable for uses in nondestructive testing.

Szepesi, Z.↗

Study of X-ray optics

The testing is reported of a polished Kanigen coated beryllium mirror in a soft X-ray telescope to be flown on a Skylark sounding rocket. This test involved inserting the telescope in a 220 foot long vacuum line and taking photographs of an X-ray resolution source. These photographs were then used to evaluate the performance of the telescope mirror as a function of distance from the focal plane and the angular distance off the telescope axis. A second test was made in which a point source was used to study the imaging characteristics by means of a pinhole and proportional counter placed in the telescope focal plane. A third test was conducted using a position sensitive detector. The efficiency and resolution was increased by polishing.

Froechtenigt, J. F.↗

Atmospheric, Non-Combusting Droplet Sizing and Spray Imaging Results From a Non-Proprietary Aero Gas Turbine Engine Pressure Swirl Atomizer using Shadowgraphy and Planar Laser Scatter

Members from industry and federal agencies of the United States have developed a collaborating group focused on improving the understanding of the atomization processes common to gas turbine engines. The group is aimed on providing high quality data using x-ray diagnostics in the internal geometry and the near-field dense spray as well as optical diagnostics in the visible spectrum, downstream of the nozzle. This paper reports results from one of the two non-proprietary injectors designs from the group: the primary-secondary injector. In particular, we characterize the spray from only the primary, pressure-swirl atomizing circuit using water through the nozzle. We observed Sauter mean diameter decreased with increased water pressure drop across the nozzle. SMD was also collected at three axial distances and showed decreased size with distance from the nozzle. Planar laser sheet droplet scattering provided qualitative assessment of the spray. Higher water pressure drops provided better atomization than lower pressure drops. The addition of swirling air flow through the injector alleviates and improves the atomization quality, particularly at the lower water pressure drops.

optical diagnostics↗

A computer program to evaluate optical systems

A computer program is used to evaluate a 25.4 cm X-ray telescope at a field angle of 20 minutes of arc by geometrical analysis. The object is regarded as a point source of electromagnetic radiation, and the optical surfaces are treated as boundary conditions in the solution of the electromagnetic wave propagation equation. The electric field distribution is then determined in the region of the image and the intensity distribution inferred. A comparison of wave analysis results and photographs taken through the telescope shows excellent agreement.

Innes, D.↗

Quantitative micro-luminescence and related studies of fine and/or glassy lunar surface materials

Papers on Raman and soft X-ray spectroscopy of lunar glasses and electron microscopy of lunar fines are presented. Individual particles of glasses from Apollo 11, 12, 14, and 15 samples were analyzed separately. Silicon emission shifts vary between parent rock types and can be interpreted as a range of Si-O distances from 1.612 to 1.637 A. Aluminum emission shifts relate to the amount of 4- and 6-coordinated Al in the glass. Raman spectra show broadened bands. Certain bands recur in many specimens and relate to the main normative minerals for the glass bulk composition, olivine, pyroxene, and anorthite. Quantitative size and shape analyses were carried out on six Apollo 14 and 15 samples of fines by computer evaluation of scanning electron microspace images. For the size range of 0.50 to 30 micron diameter, the distributions are log-normal on a number count basis. Aspect ratios range from 0.1 to 1.0 with an average value of about 0.6. The aspect ratios and a shape complexity factor vary only slightly among the samples.

Roy, R.↗