Search NASA⌕ Search

SEARCH · Search NASA

Results for “X-ray instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Early results in the search for extreme coronal line emitters with the Dark Energy Spectroscopic Instrument

Here, we present the results of our search through the early data release (EDR) of the Dark Energy Spectroscopic Instrument (DESI) for extreme coronal line emitters (ECLEs) – a rare classification of galaxies displaying strong, high-ionization iron coronal emission lines within their spectra. With the requirement of a strong X-ray continuum to generate the coronal emission, ECLEs have been linked to both active galactic nuclei (AGNs) and tidal disruption events (TDEs). We focus our search on identifying TDE-linked ECLEs. We identify three such objects within the EDR sample, highlighting DESI’s effectiveness for discovering new nuclear transients, and determine a galaxy-normalized TDE-linked ECLE rate of RG=5 −3+5×10−6 galaxy−1 yr−1 at a median redshift of z=0.2 – broadly consistent with previous work. Additionally, we identify more than 200 AGNs displaying coronal emission lines, which serve as the primary astrophysical contaminants in searches for TDE-related events. We also include an outline of the custom python code developed for this search.

Clark, Peter [Southampton U.; Portsmouth U., ICG] ↗

Hyperspectral radiance mapping and chromatic correction for temperature measurement in laser-heated diamond anvil cells

In laser-heated diamond anvil cell (DAC) experiments, the effective heated region typically decreases in size with increasing pressure, leading to steeper thermal gradients. Under these conditions, chromatic aberration in the optical path from sample to detector can significantly create bias in spectro-radiometric temperature measurement. We present a radiance-mapping approach using a hyperspectral camera that records 25 spectral channels spanning 605–875 nm at each pixel in a single exposure, providing spatially and spectrally resolved radiance in each frame. This enables chromatic effects to be recorded and corrected in data processing. We developed a procedure for hyperspectral mapping, involving per-camera calibration, crosstalk removal, measured spectral throughput functions, and optional sub-pixel co-registration to minimize chromatic distortion. The calibrated radiance maps are then used to derive temperature maps of the laser-heated hotspots. For smaller heating spots, the radiance mapping approach reveals chromatic shifts that conventional spectro-radiometric methods cannot quantify. Ambient-pressure heating experiments confirm accurate temperature retrieval. At high pressure, application of the hyperspectral system to a platinum-heating experiment at 12 GPa demonstrates stable temperature reconstruction under steep thermal gradients. Beyond mitigating chromatic aberrations, the ability to diagnose optical artifacts separately from emissivity variations during controlled test experiments or in situ suggests a path toward more rigorous spectral emissivity analysis and improved modeling of thermal transport in laser-heated DAC experiments.

47 OTHER INSTRUMENTATION↗

New developments in structure-property and amorphous materials research at the upgraded 16-BM-B Paris-Edinburgh press station at HPCAT

Beamline 16-BM-B of the High-Pressure Collaborative Access Team (HPCAT) at the Advanced Photon Source (APS) provides a Paris-Edinburgh press program to probe the structure and properties of crystalline and amorphous materials up to 12 GPa at room temperature or 7 GPa at 2000°C. During the recent APS upgrade, 16-BM-B undertook major improvements to its instrumentation and measurement techniques. The upgrade includes the addition of a 1.2 m horizontal “condenser” mirror and a new variable-sized collimation system, the combination of which decreases the acquisition time for energy dispersive X-ray diffraction measurements by a factor of 10 when compared to pre-upgrade measurements. The addition of a new Ge energy-sensitive detector and DANTE (XGLab) digital pulse processor allows for processing the increased diffraction counts with minimal deadtime. In addition to upgraded beamline components, new techniques are being developed for eventual release to the user community, including electrical resistivity and tomography measurements.

APS upgrade↗

Single-shot hard X-ray spectrometer with uniform spatial and spectral response

We demonstrate a single-shot hard X-ray spectrometer based on small-angle scattering from glassy carbon that is insensitive to XFEL beam-dependent spatial and spectral variations. Comparison with established X-ray Thomson scattering diagnostics using stochastic correlation X-ray spectroscopy demonstrates full-bandwidth coverage with meV-scale spectral resolution, enabling reliable single-shot spectroscopic measurements.

47 OTHER INSTRUMENTATION↗

Imaging from Macro to Nanoscale: Multimodal Advances in Chemical and Biomedical Imaging

Imaging increasingly serves as a multiscale framework for linking molecular mechanisms to cellular behavior, tissue architecture, and organ phenotypes in biology and unraveling fundamental processes in chemistry, physics and materials science. This Perspective highlights recent advances in chemical and biomedical imaging across macro-, micro-, and nanoscales, using representative examples published in Chemical and Biomedical Imaging (CBMI). At the macroscale, we discuss chemically selective MRI, including endogenous and exogenous CEST strategies, together with photoacoustic imaging as a hybrid modality with functional and chemical contrast. At the microscale, we consider fluorescence, label-free optical and vibrational imaging, and selected X-ray approaches that expand sensitivity, specificity, and temporal resolution in biological and materials systems. At the nanoscale, we highlight super-resolution fluorescence microscopy, single-molecule methods, tip-enhanced Raman spectroscopy, and correlative imaging strategies that resolve local heterogeneity and molecular organization. Across scales, a common theme emerges that advances in probes, contrast mechanisms, instrumentation, and sample handling are enabling chemically informed imaging that connects molecular specificity with biological context.

multiscale imaging↗

Federated learning for 2D synchrotron x-ray diffractometry: a cross-institutional approach for phase quantification of Ti–6Al–4V alloy

High-energy Two dimensional (2D) synchrotron x-ray diffractometry provides important insights into the atomistic structure and phase evolution of materials, yet traditional analysis methods remain complex, knowledge-intensive, and computationally demanding. Deep-learning models offer a powerful alternative for automating their analysis. Institutions that hold these datasets may be unwilling to share their data due to privacy and security policies, as well as the challenges associated with large-scale data transfer. As a result, models trained on local datasets often perform well only on their own data but exhibit bias and poor generalization across different instruments or facilities. To overcome these limitations, we explore federated learning (FL) for 2D synchrotron diffractograms, enabling collaborative model training without exchanging raw data. In this study, 2D synchrotron diffractograms of Ti–6Al–4V alloy collected from two independent facilities are used to train convolutional neural networks for predicting the β-phase volume fraction. Experimental results show that federated global models significantly outperform locally trained models in terms of generalization and achieve accuracy comparable to centralized trained models. These findings demonstrate the potential of FL to enable secure, cross-institutional collaboration and enhance the scalability of deep-learning-based materials characterization.

36 MATERIALS SCIENCE↗

EDXplorer: A Utility for APA Analysis

The automated particle analysis (APA) method of scanning electron microscopy (SEM) energy dispersive X-ray spectroscopy (EDS/EDX) is a useful tool for analyzing the elemental and morphological data of particulate samples. Often, such datasets have many thousands of particles, and it can be difficult to sift through the data to find meaningful trends. EDXplorer is a software utility for processing APA data. They enable the user to easily load data and determine the important components and aspects of the datasets using a powerful and versatile library of data plotting functions, mainly centered around scatter plots and histograms. These programs are intended to fill a void in the data processing of data from certain instruments, where often the user must rely on their own code or other software that is not user-friendly. EDXplorer is intended as a general plotting utility for browsing through data and discovering data trends.

Moseley, Duncan [ORNL] (ORCID:0000000343518347)↗

PIXE – State of the Art, Systems, Challenges

Particle-induced X-ray emission (PIXE) is an analytical technique for elemental analysis in which a charged-particle beam (most commonly protons, but also alpha particles or heavier ions) ionizes inner-shell electrons in target atoms. When these vacancies are filled by outer-shell electrons, the atom emits characteristic X-rays (e.g., Kα, Kβ, L-series) whose energies are unique to each element. Measuring the X-ray spectrum therefore enables identification of the elements present and, with appropriate calibration and modeling, their concentration. PIXE provides rapid, simultaneous, quantitative multi-element detection with trace-level sensitivity for many mid- to high-Z elements, often with minimal sample preparation. It is widely used across materials science (thin films, alloys, corrosion), geology (mineral chemistry, provenance) and environmental monitoring (aerosols, particulates, soils); semiconductor contamination analysis (wafer surface/trace metals), cultural heritage (pigments, inks, archaeological artifacts) and forensics (gunshot residue, glass/pain), and biological/medical studies (tissue/biomaterial trace-element mapping).

47 OTHER INSTRUMENTATION↗

Postirradiation Examination of WIRE-21 Experiment Irradiated in the High Flux Isotope Reactor

Westinghouse Electric Company is developing wireless sensors to monitor the centerline temperature and internal pressure of commercial light-water reactor fuel rods during irradiation. Oak Ridge National Laboratory and Westinghouse Electric Company developed the Wireless Instrumented RB Experiment 2021 (WIRE-21) to test wireless temperature and pressure sensor technologies in a removable beryllium position in the High Flux Isotope Reactor. The experiment was irradiated for a total of 75 days, at temperatures ranging from approximately 150°C to 400°C, resulting in a peak fast (energy > 0.1 MeV) neutron fluence of about 3 × 10 21 n/cm 2 . The temperature was intentionally cycled multiple times to compare the response of the wireless temperature sensor to collocated thermocouples. Similarly, the pressure sensor was actuated in multiple steps to compare the response of the wireless measurement to excore pressure transducers (Petrie et al., 2023). After irradiation, the experiment was disassembled in the Irradiated Fuels Examination Laboratory (IFEL) hot cell at Oak Ridge National Laboratory with the intent to recover sensor and dosimetry components, document the as-irradiated condition of the hardware, and investigate possible causes of the sensor behavior observed during irradiation. The postirradiation examination successfully recovered and preserved key WIRE-21 components. After the housing was removed using a milling machine, the internal experiment sections were examined. All eight fiber-optic sensors were recovered, cut, and stored. The silicon carbide thermometry, temperature sensor, pressure sensor, lower spacer, and selected pressure and temperature cable sections were also removed and stored. The metal bellows of the pressure sensor was found to be plastically deformed, indicating that it had been properly pressurized during irradiation and generally behaved as expected. X-ray diffraction analysis of a section of one of the irradiated inductor cores within the pressure sensor was performed and confirmed the presence of phase-pure alpha ferrite (i.e., no unexpected phase transformations). Inductance testing was performed on the irradiated pressure sensor cores using an unirradiated test coil, and DC resistance measurements of the transceiver coils were also performed. The measurements with irradiated inductor cores assembled inside unirradiated coils showed slightly reduced inductance compared to measurements made with unirradiated cores, but the difference was not sufficient to explain the more significant reductions in inductance that were observed in-pile. Therefore, it is suspected that degradation of the inductor coils (specifically the wire wrapping) is responsible for the reduced inductance observed in-pile.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Crystal Growth Scale-Up and Stability of RbSr 2 X 5 :Eu Scintillators

The discovery and development of new scintillation materials support national security needs. In these applications, large volumes of scintillator crystals are needed to achieve efficient screening for contraband. Therefore, one important step in the discovery of new scintillator compositions is testing their feasibility for scale-up and their stability. In this work, high-quality Ø22 mm crystals of two new scintillators RbSr 2 Br 5 :Eu and RbSr 2 I 5 :Eu were grown via the Vertical Bridgman method, and their scintillation properties were characterized. Here, the Ø22 mm RbSr 2 I 5 :Eu crystals could be grown with fast translation rates up to 3.5 mm/h. Both RbSr 2 Br 5 :Eu and RbSr 2 I 5 :Eu had high scintillation performance, including light yields of 46,000 and 61,000 ph/MeV, respectively, for Ø22 × 35 mm crystals. Additionally, properties related to physical stability were investigated, including the coefficients of thermal expansion via high-temperature X-ray diffraction (HTXRD) as well as moisture sensitivity. HTXRD confirmed the absence of solid–solid phase transitions and showed that RbSr 2 Br 5 had minimal thermal expansion anisotropy compared to RbSr 2 I 5 and some other inorganic metal halide scintillators, which favors the growth of large-sized crystals.

36 MATERIALS SCIENCE↗

High-resolution in-beam video rate imaging with the ClearXCam for synchrotron beamlines

The ClearXCam detector is a new video rate imaging in-beam monitor based on a diamond sensor. Imaging with 2304 effective pixels is achieved by sequentially biasing one of 48 metal stripes on one side of a diamond sensor, while reading out the current from 48 stripes on the other side of the sensor. This system was characterized for real-time X-ray beam diagnostics at synchrotron beam­line 17-BM at the National Synchrotron Light Source II. Significant results include: detection of in-beam structure via the imaging mode, beam focusing in one minute with real-time imaging feedback during a focusing event, linearity over five orders of magnitude, validation of a fast mode operating at 100 Hz, and sub-micron beam-positioning resolution. The system is now available commercially.

36 MATERIALS SCIENCE↗

Mass dependence of halo baryon fractions from the kinetic Sunyaev–Zeldovich effect

ABSTRACT We detect the kinetic Sunyaev–Zeldovich imprint of peculiar motions of galaxy groups and clusters, using the photometric Dark Energy Spectroscopic Instrument Legacy Surveys together with cosmic microwave background (CMB) maps from the Atacama Cosmology Telescope (ACT). We develop a comprehensive forward model based on the AbacusSummit cosmological simulations: Mock galaxy group catalogues and synthetic kinetic Sunyaev–Zeldovich (kSZ) maps are generated, together with a reconstructed peculiar velocity field that allows for photo-z errors, redshift-space distortions, and survey masks. We investigate possible contamination from the cosmic infrared background (CIB), finding that CIB effects are subdominant to the kSZ signal in the relevant ACT frequency channel. We then predict the kSZ signal expected when stacking CMB temperature maps around groups, taking account of their estimated radial velocities. Comparing the model with observations, we are able to constrain the total baryon fraction within haloes, as well as their internal gas profiles. We find evidence for mass dependence of the halo baryon fraction within the virial radius. The gas fraction in massive groups is consistent with the universal baryon fraction, but low-mass groups ($10^{12.5} \lesssim M\, /\, h^{-1}\, \mathrm{M}_\odot \lesssim 10^{14}$) are depleted to $0.38 \pm 0.11$ times the universal baryon fraction. We find this low virial baryon fraction to be consistent with an extended gas profile, for which the total baryon content reaches the universal value well beyond the virial radius. This conclusion is consistent with previous analyses using X-ray, kSZ, and weak lensing, and plausibly reflects energetic feedback processes from the galaxies in these haloes.

Roper, Finn A [Institute for Astronomy, University↗

Single-shot imaging with randomized structured illumination at a free electron laser

Stroboscopic nanoscale imaging with free electron laser light is revolutionizing our understanding of fast dynamics in heterogeneous systems. The short wavelength of X-ray and extreme ultraviolet radiation makes it possible to achieve nanoscale resolution, while resonance with atomic transitions gives access to electronic and magnetic degrees of freedom. Here, we report on our implementation of a recently developed imaging method, randomized probe imaging, at a free electron laser. The advantage of randomized probe imaging over existing methods is its compatibility with extended and strongly scattering samples. Our implementation delivers robust single-shot reconstructions at up to a full-pitch resolution of 400 nm over a field of view with a 40 µm diameter. We also demonstrate single-shot imaging of magnetic domain structures using circular dichroism at resonance, paving the way to future time-resolved studies of magnetic dynamics, shock physics, and the dynamics of collective electronic phases.

47 OTHER INSTRUMENTATION↗

Characterization of high-flux cadmium zinc telluride detectors coupled to MM-PAD readout ASICs for high-flux X-ray applications

High-flux cadmium zinc telluride (HF-CZT) is a promising material for next-generation X-ray imaging due to its high stopping power, wide bandgap, and improved resistance to radiation-induced polarization [1]. We bonded 2 mm thick HF-CZT sensors with Cornell's Mixed-Mode Pixel Array ASICs, which combine analog charge integration and in-pixel digital counting to achieve single X-ray sensitivity, large full well capacity, and frame rates up to 10 kHz [2,3]. Detector characterization showed stable electron collection above 150 V bias, while hole collection remained limited by trapping even at 700 V. Temporal studies revealed non-negligible afterglow, with an unexpected increase in afterglow at higher biases, which was reduced by infrared illumination, suggesting that injected carriers reduce trapping near contact interfaces. Polarization measurements confirmed improved stability compared to conventional CZT, though polarization effects persisted, particularly with hole collection, with up to 5% signal loss and spatial distortion at high doses.

36 MATERIALS SCIENCE↗

Energy response characterization of current-mode MeV Cherenkov aerogel detectors

Current-mode Cherenkov aerogel detectors have been used to measure time resolved spectra of MeV radiographic x-ray sources and have been considered to replace gas Cherenkov systems. The simulations of the Cherenkov response of aerogel detectors have uncertainties in how to model the complex structure of aerogels. Data from three sites—the Idaho electron beam, the Los Alamos Site electron beam and microtron sources at Los Alamos—have been used to calibrate the relative energy response of 15 aerogels, varying in density from 10 to 430 mg/cm 3 , from incident electrons with energies from 1 to 12 MeV. Detector simulations need to introduce density variation in the aerogels to match the collected data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Full-polarization millimeter wavelength variability of Sagittarius A * during the 2018 EHT campaign

Context. Sagittarius A* (Sgr A*), the supermassive black hole at the center of the Milky Way, provides a unique laboratory to study accretion dynamics and plasma processes near the event horizon. Aims. We investigated the variability and polarization properties of Sgr A* using ALMA observations during the 2018 Event Horizon Telescope campaign. Methods. We analyzed high-cadence full-polarization light curves from ALMA at millimeter wavelengths, performed time-series analysis, and investigated the temporal behavior during an X-ray flare observed by Chandra on 2018 April 24. The variability characteristics are compared with expectations from standard accretion flow models. Results. We find low variability in total intensity (σ/μ < 10%), but significantly higher variability in linear and circular polarization (∼30% and ∼50%, respectively). A time-series analysis reveals red-noise variability, with power spectral densities between −2 and −3 across all Stokes parameters. Polarized intensity shows stable intra-day timescales, while total intensity exhibits more variable timescales, suggesting distinct emission regions, with polarization likely arising from a coherent structure. On April 24, a statistically significant inter-band delay in polarized intensity coincides with a near-simultaneous X-ray and millimeter peak that deviates from the typical delayed flare scenario. This event also features enhanced millimeter variability and coherent polarization loop evolution. The observed simultaneity challenges standard models of transient synchrotron emission with cooling delays, favoring instead a scenario of continuous energy injection in an optically thin region. Conclusions. Our results offer new constraints on the physical mechanisms driving variability in Sgr A*, and provide key observational input for refining theoretical models of accretion and plasma behavior in the vicinity of supermassive black holes.

Galaxy: center↗

The pathfinder X-Ray axion telescope for the International Axion Observatory (IAXO) and axion searches at the CERN Axion Solar Telescope (CAST)

The axion, a hypothetical pseudo-scalar particle proposed by Peccei and Quinn to resolve the strong CP problem in quantum chromodynamics, remains one of the most compelling dark matter candidates. Axions and Axion-Like Particles (ALPs) are characterized by a broad and largely unconstrained parameter space in mass and coupling strength, motivating extensive experimental searches. The International Axion Observatory (IAXO) is a next-generation axion helioscope designed to achieve over an order of magnitude improvement in sensitivity to the axion-photon coupling constant gaγ relative to previous experiments such as the CERN Axion Solar Telescope (CAST). IAXO will employ large-scale superconducting magnets, precision x-ray optics, and ultra-low-background detectors to search for solar axions produced primarily via the Primakoff effect. This work presents the design and performance of the IAXO pathfinder x-ray optic, a technological demonstrator that validated the optical concepts for IAXO through axion searches at CAST. Comprehensive ray-tracing simulations and experimental measurements were conducted to assess the optic's effective area, detection efficiency, and background suppression capabilities. Deployed at CAST in conjunction with Micromegas and GridPix detectors, the Pathfinder demonstrated record-setting sensitivity to both gaγ and the axion-electron coupling gae, establishing the most stringent laboratory constraints on solar axions to date. These results confirm the viability of the IAXO optical design and detector concept, providing a critical technological benchmark that informs the ongoing development of the BabyIAXO and full-scale IAXO telescopes.

47 OTHER INSTRUMENTATION↗