Search NASA⌕ Search

SEARCH · Search NASA

Results for “X-ray mirror”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Management of optics

American Science and Engineering, Inc., designed the large X-ray optic for the HEAO-2 X-ray Telescope. The key element in this project was the High Resolution Mirror Assembly (HRMA), subcontracting the fabrication of the optical surfaces and their assembly and alignment. The roles and organization of the key participants in the creation of HRMA are defined, and the degree of interaction between the groups is described. Management of this effort was extremely complex because of the intricate weaving of responsibilities, and AS&E, as HEAO-2 Program managers, needed to be well versed in the scientific objectives, the technical requirements, the program requirements, and the subcontract management. Understanding these factors was essential for implementing both technical and management controls, such as schedule and budget constraints, in-process control, residence requirements, and scientist review and feedback. Despite unforeseen technical problems and interaction differences, the HEAO-2 was built on schedule and to specification.

Kirchner, T. E.↗

Properties of vacuum-evaporated boron films

The work on the properties of thin boron films made by vacuum evaporation of elemental boron using an electron beam as the energy source is reported. The program aimed at characterizing the properties of vacuum evaporated films. The work was directed toward those variables considered to be important in affecting the tensile strength of the boron films. In general, the thickness of the films was less than 0.002 in. The temperature of the substrate on which the boron was condensed was found to be most important. Three distinctly different forms of boron deposit were produced. Although the transition temperature was not sharply defined, at substrate temperatures of less than approximately 600 deg C the boron deposits were amorphous to X-ray. If the substrate were highly polished, the deposits were black and mirror-like. For substrates with coefficients of thermal expansion close to that of boron, the deposits were then continuous and uncracked. The studies suggest that the potential continues to exist for film-type composites to have both high strength and high modulus.

Feakes, F.↗

Image Properties of an X-Ray Telescope of the Wolter-1 Type with Emphasis on Contrast Reduction by Diffuse Reflection

Theoretical and experimental results are presented on the geometrical-optic imaging properties of a Wolter-1 type paraboloid-hyperboloid X-ray telescope. Particular consideration is given to the effect of microroughness of the mirror on the imaging properties. Experiments were conducted in which scattering properties were determined as a function of wavelength, incidence angle, and roughness of the plane mirrors. Results indicate the need for optimization of mirror material and polishing technology as well as the development of improved mirror manufacturing techniques. The use of transmission gratings along with the Wolter-1 type telescope in spectroscopy applications is discussed.

Lenzen, R.↗

Fabrication of X-ray telescopes for sounding rocket flights

Two X-ray telescopes and two detector systems were fabricated, and one of the telescopes (15 in. diameter, Wolter type I telescope) was flown on two sounding rocket flights. The telescopes were fabricated using the diamond point technique which provided the accurate figure of the mirrors to about a focal plane blur of 0.5 arc minutes. The 15 in. telescope mirrors were polished using standard polishing techniques to remove tooling marks from the diamond turning, then chemically polished to bring the X-ray reflectivity up to nearly the theoretical values. The optical image formed by the 15 in. telescope was found to produce a blur of about 40 arc seconds for a parallel beam of incoming laser light. The first flight of the telescope produced an X-ray image of Capella which indicated that the X-ray image was blurred to the extent of about 2 arc minutes. This additional image degradation was due to a slight error in focusing the X-ray image onto the detector.

Source record↗

Fabrication of a focusing soft X-ray collector payload

A large area X-ray focusing collector with arc minute resolution and a position sensitive detector capable of operating in the soft X-ray region was developed for use on sounding rockets in studying stellar X-ray sources. The focusing payload consists of the following components, which are described: (1) a crossed paraboloid mirror assembly; (2) an aspect camera and star tracker; (3) a focal plane assembly containing an imaging proportional counter and its preamplifiers, high voltage power supplies and gas system; (4) a fiducial system; and (5) housekeeping, data handling, instrumentation and telemetry electronics. The design, tests, and operation are described.

Davis, J. M.↗

High resolution studies of the solar X-ray corona from Aerobee rockets

The research in high resolution solar X-ray astronomy is reported. The payload for the Aerobee 150 launch vehicle, which included a 23 cm diameter mirror whose polished surface was a nickel-phosphorus alloy is discussed along with the high resolution measurements, by Flight 13.028 CS, of the temperature and density structure of the lower corona. Flight 13.029 CS is also discussed.

Davis, J. M.↗

Focal plane transport assembly for the HEAO-B X-ray telescope

The High Energy Astronomy Observatory - Mission B (HEAO-B), an earth orbiting X-ray telescope facility capable of locating and imaging celestial X-ray sources within one second of arc in the celestial sphere, is considered. The Focal Plane Transport Assembly (FPTA) is one of the basic structural elements of the three thousand pound HEAO-B experiment payload. The FPTA is a multifunctional assembly which supports seven imaging X-ray detectors circumferentially about a central shaft and accurately positions any particular one into the focus of a high resolution mirror assembly. A drive system, position sensor, rotary coupler, and detent alignment system, all an integral part of the rotatable portion which in turn is supported by main bearings to the stationary focal plane housing are described.

Brissette, R.↗

The application of soft X-ray imaging techniques to auroral research

The feasibility of building and operating a grazing incidence X-ray telescope for auroral zone studies from the Polar Plasma Laboratory (PPL) is discussed. A detailed structural analysis of the preferred design, an array of seven nested Wolter mirrors, is presented. An engineering evaluation of the requirements for the instrumental configuration, power, weight and telemetry is included. The problems of radiation hardening and thermal control are discussed. The resulting strawman instrument is presented.

Source record↗

Analytical study of the large orbital X-ray telescope imaging system

Results of an analytical study of the large orbital X-ray telescope (LOXT) are presented. The LOXT consists of a nested array of four conventional paraboloidal-hyperboloidal X-ray telescopes arranged with a common optical axis and a common focal plane. The composite nested array has a nominal effective focal length of 135.0 inches. The equations of the various mirror surfaces and the numerical values of the parameters in the defining equations are given in the technical specification sheets for the LOXT.

Foreman, J. W., Jr.↗

Optimum shape of a Kirkpatrick-Baez X-ray reflector supported at discrete points for on-axis performance

A method is proposed for optimizing the on-axis resolution of a Kirkpatrick-Baez reflecting element. The proposed procedure provides a way to determine the location of each of the 11,200 support points (175 different points plus repeats) by using a computer-assisted structural-optical software package. This automated procedure will make it possible to determine the optical characteristics of an entire telescope module consisting of seventy mirrors.

Cohen, L. M.↗

Particle energization in the inner, nonazimuthally symmetric magnetospheres of neutron stars

The energization process of magnetic pumping, a combination of time dependent magnetic mirror fields with pitch-angle scattering, is applied to trapped charged particles drifting in corotating, azimuthally nonsymmetric neutron star magnetospheres. When particle energization is balanced by synchrotron radiation loss, it is found that protons, rather than electrons, reach considerable kinetic energies and radiate, in the X-ray regime, at rates up to the 10 to the 6th power MeV/proton/sec.

Borovsky, J. E.↗

Determination of the structure and heating mechanisms of coronal loops from soft X-ray observations with the solar probe

High resolution soft X-ray imaging from the solar probe is justified in terms of the expected scientific returns which include the determination of the temperature and density structure of a coronal loop. The advantages of the grazing incidence telescope over the multiple pinhole camera are discussed. An instrument package is described which includes a grazing incidence mirror, a thermal prefilter, a three position filter wheel and a focal plane detector baselined as an 800 by 800 back-illuminated charge coupled device. The structural assembly together with the data processing equipment would draw heavily on the designs being developed for the Solar Polar Mission.

Davis, J. M.↗

A moderate-resolution, wide-band, astronomical echelle spectrograph

An echelle spectrograph is described which is specifically designed for use on a 52-in. f/7.6 telescope as an instrument optimally suited for studying spectra of the faint optical counterparts to X-ray stars at moderate spectral resolution. The spectrograph is also able to accomodate a two-dimensional photon-tagging panoramic image detector so that high-time-resolution studies of the spectra of variable stars can be carried out. The equations for echelle spectrographs are summarized, and some features of the present instrument are discussed. These include its prism cross-disperser, small elliptical flat mirror, and unusually high efficiency. An iron-argon calibration spectrum obtained by pressing the film against the output fiber optics of a three-stage electrostatically focused image intensifier, a spectrum of P Cygni taken by placing the film directly in the image plane of the spectrograph, and a photon-counted image of a small section of an echellogram produced during an observation of the Ring nebula in Lyra are provided to illustrate the performance of the instrument.

Bardas, D.↗

A focusing collector for long wavelength X-ray astronomy.

Rocket studies of the low-energy X-ray sky conducted so far suffer from serious experimental problems. Therefore, an apparatus was design ed to overcome the outstanding experimental problems. The instrument developed was successfully flown in an Aerobee-170 rocket. The new device utilizes a grazing incidence paraboloid as an energy concentrator and low-pass filter. The effective bandpass of the instrument from 100 to 280 eV is determined by the combination of the counter window transmission and the mirror reflectivity.

Yentis, D. J.↗

Constance mirror program: Progress and plans

The current state of the mechanics of the Constance II experiment, the physics results gathered, the motivation background, and future plans for the Constance II experiment are reviewed. Several improvements have been made and several experimental investigations have been completed. These include the construction/installation/testing of: (1) liquid-nitrogen cooled, Ioffe bars installed, (2) a diverter coil (3) the 100 kW ICRF generator, (4) the data acquisition system, and (5) the optimum hot-iron operation of the machine with Titanium and pulsed-gas plasma guns. Measurements were made of the density, temperature, and radius of the plasma. Ion-cyclotron fluctuations were observed, their bandwidth measured, and data collected demonstrating resonance heating. New X-ray diagnostics were designed and purchased, and progress on the Thomson scattering was made. Finally, a new hot cathode gun was designed and constructed.

Klinkowstein, R. E.↗

The Einstein Observatory and future X-ray telescopes

A history of the events leading to the development and flight of the Einstein Observatory is given. The advantages of using grazing-incidence telescopes for solar and extrasolar X-ray astronomy is first discussed and followed by a description of the HEAO program. The Einstein Observatory marks a departure from the manner in which X-ray investigations are carried out, from individual experiments to the shared use of large facilities. The Observatory has achieved a sensitivity to point sources of 10 to the -14th erg/sq cm-sec in the 1-3 keV band, a flux 500 times smaller than previously detected and about 10 million times smaller than that of the first extrasolar source detected in 1962. The design philosophy of the Observatory entails three principles: (1) the unified scientific approach, (2) the establishment of spacecraft requirements at lowest acceptable levels that still allow operating flexibility, and (3) the idea of 'soft' rather than 'hard' failure. The mirror design, including the high resolution imager, the imaging proportional counter, and the solid-state and focal plane crystal spectrometers, is also given. An account of the struggle to gain acceptance by the scientific community and the funding agencies of the need for the Einstein Observatory mission is discussed. Finally, results of observations made by the Observatory are presented in detail, along with plans for future observation experiments.

Giacconi, R.↗

Vignetting characteristics of the S-056 X-ray telescope

A ray trace analysis of the vignetting characteristics of the S-056 X ray telescope is presented. The relative energy is calculated in the spot formed in the focal plane of the S-056 X ray telescope by an off axis point source at infinity for off axis angles of 0, 1, 2, ..., 35 arc minutes. At each off axis angle, the relative energies are evaluated using theoretical X ray reflectivity curves for wavelengths of 8.34 A, 17.57 A, and 27.39 A, and also using an experimental X ray reflectivity curve for 8.34 A. The effects of vignetting due purely to the geometry of the S-056 optical system are evaluated separately, as well as jointly with the effects of mirror reflectivity.

Foreman, J. W., Jr.↗