Search NASA⌕ Search

SEARCH · Search NASA

Results for “X-ray total scattering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Limited proteolysis of pea protein to promote aggregation/gelation: role of enzyme concentration and molecular characteristics

Limited proteolysis promotes aggregation/gelation of plant proteins, but its relationship with the molecular characteristics of hydrolysates remains poorly understood. In here, response surface methodology was employed to evaluate the effects of protein concentration, Alcalase level, and hydrolysis time on the storage modulus (G′) of pea protein hydrolysates (PPH). 7.5% protein, 1.65% Alcalase, and a 6-min reaction time resulted in the highest relative increase in G′ upon heating PPH, whereas both higher (3.55%) and lower (0.3%) Alcalase levels led to less increment. Increasing the Alcalase level increased the degree of hydrolysis while decreasing the molecular weight, surface hydrophobicity, and total sulfhydryl and disulfide bond contents of PPH. Confocal laser scanning microscopy and X-ray scattering analyses found PPH produced with 1.65% Alcalase formed interconnected aggregates with dual structural domains, but not at other Alcalase conditions. These results demonstrate the role of controlled proteolysis in governing the aggregation/gelation behavior of PPH.

X-ray scattering↗

Probing the local structure of Bi 2 O 3 chemical derivatives: the neglected cation sublattice

High-resolution synchrotron X-ray diffraction data confirm the stabilization of the average structure at ambient temperatures as a defect fluorite structure in ternary and quaternary oxides of Bi 2 O 3 , where some Bi cations are replaced with Dy 3+ and/or Er 3+ , Nb 5+ and W 6+ . Rietveld refinement of the diffraction data indicates that when the larger cation Er 3+ (0.89 Å) is replaced with smaller cations W 6+ (0.42 Å) and/or Nb 5+ (0.48 Å), the unit-cell parameter a, based on the relative ionic radii of the substituents, counterintuitively increases. Total scattering data show that the identity of the cation substituent is important in determining the positions of some Bi cations in the defect fluorite structure. Er 3+ and Dy 3+ cations induce monoclinic-like distortions that extend only locally in the Bi 3+ sublattice. X-ray absorption spectroscopy provides evidence that some Dy cations, in the δ phases, prefer to keep a similar local environment to that in the parent Dy 2 O 3 . W cations are found to be predominantly tetrahedrally coordinated in the δ phases explored in this work.

36 MATERIALS SCIENCE↗

Neutron Total Scattering Analysis of Materials for the Nuclear Fuel Cycle

Here, this paper reviews recent experimental efforts at the University of Tennessee and Oak Ridge National Laboratory to comprehensively characterize the structural details of materials relevant for the nuclear fuel cycle by employing advanced neutron scattering techniques. For the study of nuclear ceramics, neutron scattering offers distinct advantages over traditional laboratory or synchrotron X-ray diffraction, including enhanced sensitivity to elements with a low atomic mass, such as oxygen, nitrogen, and carbon. The key to these efforts is the recent advancement in the neutron scattering infrastructure at the high-flux diffractometers at the Spallation Neutron Source. The high neutron flux at these instruments enables neutron total scattering, a nondestructive bulk technique that simultaneously captures both short-range structural effects through pair distribution function analysis and long-range order through diffraction pattern analysis. This approach is particularly important for a comprehensive description of defective, disordered, or amorphous nuclear materials. The case studies presented here include analyses of the local defect structure in hyperstoichiometric uranium oxides and short-range order of ion-irradiated ceramics. This advanced analytical methodology will improve our understanding of the behavior of materials in extreme environments and contribute to the development of more resilient nuclear materials.

Neutron scattering↗

Optimizing microfluidic flow cell geometry for in situ resonant soft X-ray characterization of molecular nanostructures

Liquid-phase resonant soft X-ray scattering (LP-RSoXS) is an emerging label-free technique to probe chemically resolved nanostructures of molecular or hybrid materials in liquid environments. Still, quantitative analysis is hindered by the pressure-induced deformation of thin silicon nitride (SiN) membranes used as windows in microfluidic flow cells, which attenuates the signal in nonlinear ways, making experimental optimization difficult. Here, in this work, we directly characterize this deformation under experimental conditions for a variety of cell configurations. We use this to develop a predictive model that combines transmission effects of SiN bowing, incident X-ray beam profiles, and material-dependent resonant scattering cross sections to simulate the effective scattering intensity at the detector across the carbon K-edge. Maps of the total signal across the flow cell window reveal that increasing the window width and polymer concentration shifts the anisotropic intensity distributions from the center toward the edges of the window. It was determined that an optimal SiN thickness of 50 nm, with a window aperture of 104 μm, maximizes the total signal for typical solute concentrations and energies across the carbon K-edge. Our results overturn the assumption that corner regions dominate the scattering signal, offering explicit design guidelines for maximizing LP-RSoXS signals and significantly advancing the quantitative application of this technique to the characterization of molecular and hybrid nanostructured materials in liquids.

Grabner, Devin [Washington State Univ., Pullman, W↗

Quantum Interference in Two-Atom Resonant X-ray Scattering of an Intense Attosecond Pulse

We theoretically investigate resonant x-ray scattering from two noninteracting Ne+ ions driven by an intense attosecond pulse using a nonrelativistic, QED-based time-dependent framework. Our model includes Rabi oscillations, photoionization, Auger decay, and quantum interference among elastic scattering and resonance fluorescence pathways. We analyze how the total scattering signal depends on pulse intensity, atomic configuration, and initial electronic state. We find that the total resonant scattering yield exceeds its nonresonant counterpart; the angular dependence of the signal qualitatively resembles a two-atom structure factor; and the visibility of interference fringes is sensitive to pulse area and the initial electronic state. Only a subset of final states reached via resonance fluorescence exhibits interference, determined by the indistinguishability of photon emission pathways. Fringe visibility is maximized in the linear scattering regime, where ionization is minimal and resonance fluorescence pathways can be largely indistinguishable. These results highlight optimal conditions for applying ultrafast resonant x-ray scattering to single-particle imaging.

Venkatesh, Akilesh↗

Ion Clusters in Multicomponent Solutions Determined from X-ray PDF and SAXS Analysis: The NaNO 2 –NaOH–H 2 O System

Here, this study explores ion cluster formation in the NaNO 2 –NaOH–H 2 O system to understand how ion cluster formation is influenced by the composition in multicomponent mixtures. X-ray pair distribution function (PDF) and small-angle X-ray scattering (SAXS) identified complex ion clusters in concentrated NaNO 2 and NaOH solutions as well as their mixtures. PDF analysis showed that the Na–O distance depended primarily on total Na + concentrations rather than anion composition, whereas the nitrite-water oxygen distance stayed the same regardless of concentration or composition. This result indicates that the nitrite ion hydration was relatively independent of composition. SAXS confirms local fluctuations and coherent clusters with notable size differences between NaOH and NaNO 2 solutions. SAXS analysis of mixed solutions shows that their clusters are an average of the individual solutions, indicating mixed clusters.

Reynolds, Jacob G. [Central Plateau Cleanup Compan↗

Development of High Energy Resolution Fluorescence Detection Methods for Advanced Microscale X-ray Absorption Fine Structure Analysis of Critical Elements (Final Report)

This project is developing High-Energy Resolution Fluorescence Detection (HERFD) X-ray Absorption Fine-Structure Spectroscopy (XAFS) at the hard X-ray microprobe beamline at GSECARS beamline 13-ID-E, at the Advanced Photon Source at Argonne National Laboratory. This enhancement will improve sensitivity and spectral interpretation limitations of conventional XAFS which uses energy dispersive solid-state detectors (SSD) to measure the total fluorescence yield (TFY-XAFS). By using high-quality Si and Ge crystal analyzers to select X-ray fluorescence (XRF) from specific emission lines, background signals from other elements or X-ray scattering that can paralyze SSDs can be nearly eliminated, improving the sensitivity to the oxidation and chemical state of dilute species even though the solid angle of the analyzers is relatively small. Furthermore, by using analyzers of low-strain Si or Ge, the energy selection can be smaller than the natural widths of the core electron level. We are particularly interested in applying these enhanced sensitivities to Lanthanide series of rare-earth elements, which are typically at concentrations at or below 10 ppm, and where spectral overlaps with the 3rd row transition metals degrade sensitivity.

47 OTHER INSTRUMENTATION↗

Sulfate Promotes Compact CaCO 3 Formation and Protects Portland Cement from Supercritical CO 2 Attack

Supercritical (sc) CO 2 in geologic carbon sequestration (GCS) can chemically and mechanically deteriorate wellbore cement, raising concerns for long-term operations. In contrast to the conventional view of “sulfate attack” on cement, we found that adding 0.15 M sulfate to the acidic brine can significantly reduce the impact of scCO 2 attack on Portland cement, resulting in stronger cement than that found in a sulfate-free system. Scanning electron microscopy revealed a decreased total attack depth in reacted cement in the presence of sulfate. With a newly defined minimum porosity term in reactive transport modeling, our model suggests that sulfate caused CaCO 3 to fill more nanopore spaces in the cement. Small angle X-ray scattering experiments also showed that sulfate can decrease the pore sizes of the carbonate layer. The results suggest that the interactions between sulfate and cement can generate a less porous CaCO 3 layer, which better resists acidic brine. Using this mechanism as a proof-of-concept, we tested the incorporation of sodium sulfate into Portland cement and synthesized new cement composites that show stronger resistance against scCO 2 attacks. Finally, these newly discovered interfacial interactions between CaCO 3 and sulfate provide new insights into engineering mechanically strong and green materials for safer GCS.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of current density measurement methods for high-current, low-beta electron beams

Recent current density measurements with a low-beta electron beam (β=0.5-0.75) are strongly affected by electron scatter and Cherenkov limits. These invasive measurements are heavily influenced by the electron energy and the intercepting material properties: density, index of refraction, and atomic number. We evaluate various measurement methods, including x-ray scintillation and Cherenkov emission. To optimize the x-ray scintillation technique for this energy regime, metal foils of differing atomic number (Z) and thickness were placed upstream of a scintillation screen. We have selected Cherenkov emitters, based on a material refractive index, in order to differentiate the contributions from electron scatter and produced fluorescence, Cherenkov emission, and total internal reflection. The observed distributions for both approaches are verified through MCNP6®. Additionally, the simulations provide insight as to what physical processes dominate the measured distribution. We conclude by determining the limits and optimal measurement range for each measurement technique.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

FY26 Progress Report on the Operation of the Activated Materials Laboratory at the Advanced Photon Source as a Nuclear Science User Facilities Partner Facility

The Activated Materials Laboratory (AML), located in the Long Beamline Building of the Advanced Photon Source (APS) at Argonne National Laboratory (ANL), provides a centralized radiological capability for preparing, handling, and supporting synchrotron experiments on activated materials. As a Nuclear Science User Facilities (NSUF) partner facility, the AML enables the receipt of radioactive shipments, open-form sample handling, encapsulation, transport of specimens to and from APS beamlines, and experimentation with dedicated equipment. The partnership includes the APS 1-ID and 20-ID beamlines, which provide high-energy x-ray scattering, tomography, and diffraction microscopy techniques for ex-situ, in-situ, and grainresolved three-dimensional (3D) characterization. All samples supported through the AML and partner beamlines must meet radiological limits of less than 100 mrem/h at 30 cm. This FY26 progress report summarizes the first full year of AML operations as an NSUF partner facility and highlights progress in both user support and capability development. By the end of FY26, the AML had received a total of 10 NSUF-awarded projects, including 2 Consolidated Innovative Nuclear Research (CINR), 7 Rapid Turnaround Experiment (RTE), and 1 Super RTE projects. Beamtime was fully delivered for 3 RTE projects and partially delivered for 1 CINR project, demonstrating successful workflows for receipt, encapsulation, beamline transfer, and radiological experiment execution. These efforts demonstrated safe radiological experiments at APS beamlines for samples with dose rates above the historical 5 mrem/h threshold and now up to 100 mrem/h at 30 cm, marking an important milestone for neutron-irradiated materials research. During FY26, the AML also expanded its experimental capabilities. A Psylotech xTS load frame with in-grip rotation was deployed for room-temperature mechanical testing with threedimensional x-ray characterization during interrupted loading. A Linkam TS1500V vacuum heater was commissioned for thermally driven studies, and temperature calibration experiments were performed to establish specimen-relevant thermal profiles. In parallel, a customized split-tube furnace for high-temperature mechanical testing entered commissioning, and initial work began on robotic sample handling to reduce worker dose and improve operational efficiency. Data workflow and beamline operations continued to mature. Together, these developments demonstrate that the AML is becoming a unique national resource for safe, efficient, and scientifically advanced characterization of activated materials at the APS.

Zhang, Xuan↗

Actinide 5f Occupations: The Case of PuO 2

In actinide chemistry, the formal number of open-shell 5f electrons, n open , is a well-defined quantity with an integer value. The effective 5f occupation, n f , additionally takes donation and back-donation into account, generally has a non-integer value, and has varying numerical definitions. The present study explores the important distinction between n f and n open in actinide chemistry with the example of PuO2, by using electronic structure methods with a relativistic Hamiltonian in combination with experimental Pu M 5 -edge high-energy-resolution X-ray absorption and emission spectroscopic data. The total donation to the metal in PuO 2 is between 3.1 and 2.4 electrons, depending on the type of calculation, most of which is to the Pu 6d and 5f shells. The donation into 5f is sensitive to the approximations in the electronic structure model but likely amounts to 1.6/0.8 electrons when the diffuse regions of the 5f shell are included/excluded. Valence band resonant inelastic X-ray scattering experiments demonstrate that Pu 5f electron density is present in the valence band; thus, there is a clear experimental signature of covalent bonding in PuO 2 . Pu M 5 -edge and M 3 -edge high-energy-resolution X-ray absorption near-edge structures for Pu 3+ and Pu 4+ in an aqueous solution are compared to PuO 2 , showing that Pu in PuO 2 has an nf closer to Pu 4+ (aq).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Overview of oxygen opacity experiments at the National Ignition Facility and investigation of potential systematic errors

Experiments to measure oxygen opacity at stellar interior conditions have been performed at the National Ignition Facility in a Discovery Science campaign. These experiments utilize the Opacity-on-NIF platform with a sample comprised of O, Mg, and Si. The spectral data from the Opacity Spectrometer cover the 1000–2000 eV photon energy range showing bound-free continuum absorption from O and line absorption from Mg and Si. DANTE and the Gated X-ray Detector are employed to measure the sample plasma’s temperature and density, respectively. Initial data show lower transmission than expected by theoretical models, raising questions of whether potential background or data uniformity concerns could produce systematic errors in the inferred transmission. Here, we investigate three concerns thought to be important for the oxygen opacity data, including instrumental scattered background, sample self-emission non-uniformity, and backlight continuum non-uniformity. Additionally, we show the effect of a recently developed method to account for 2nd order crystal reflection. The total effect of these concerns on one experiment is found to be small compared to the observed difference between the inferred transmission and a model calculation at the inferred temperature and density. Thus, we conclude that these potential sources of systematic error cannot account for the observed difference, increasing the likelihood of a real effect due to the high temperature and density conditions. However, because this is only a single experiment, we cannot make a firm conclusion. More experiments measuring the opacity and necessary calibrations are needed to assess the reproducibility and uncertainty of this result.

79 ASTRONOMY AND ASTROPHYSICS↗

Intercalation-Induced Amorphization Boosts Aqueous Magnesium-Ion Storage

The design of aqueous battery cathode materials that can store divalent ions with high capacity and satisfactory reversibility is of great technical importance and challenge. Here, we report that divalent Mg 2+ storage is facilitated by an intercalation-induced amorphization of vanadate electrode materials. Electrokinetic analyses and in situ synchrotron X-ray diffraction and absorption spectroscopy collectively demonstrate that vanadate layered materials (Li–V 3 O 8 ) undergo a structural transformation to amorphization induced by Mg 2+ intercalation, and a reversible restoration of crystalline structure upon Mg 2+ deintercalation. Debye scattering simulations suggest that intercalation-induced turbostratic disorder, especially random rotations, translational shifts, oscillatory motions, or varied interlayer spacing of adjacent V–O molecular layers, could be responsible for the observed amorphization. The highly distorted local structure, in turn, facilitates Mg 2+ intercalation across the vanadate electrode materials, responsible for nearly 3/7 of the total Mg 2+ ions intercalated. The study presented reveals an intriguing relationship between ion transport and the reversible amorphization-to-crystallization dynamics it induces, opening a paradigm for designing advanced aqueous battery electrodes.

36 MATERIALS SCIENCE↗

Multiplexing and Demultiplexing Signals for Radiography Application Using the Discrete Fourier Transform

Our goal is to develop an X-ray phase-contrast imaging system that can provide excellent soft tissue contrast of phase, attenuation, and small-angle scatter. We propose to replace the common system of G0, G1, and G2 gradings with a biprism array to replace the G1 grading and introduce a novel X-ray tube designed to replace the motion of the phase stepping grading G2. The proposed X-ray tube uses temporal multiplexing to provide simultaneous virtual “electronic phase stepping.” In this work the discrete Fourier transform is used to separate from the composite measurement individual X-ray phase contrast measurements sampled at different frequencies. The method performs a discrete Fourier transform of a composite refence sequence to obtain using the frequency amplitudes calibration factors needed to extract the X-ray phase contrast measurement amplitudes from the composite image. The composite reference sequence is the sum of the individual sequences, at different frequencies, with amplitudes of one. The method takes the discrete Fourier transform of this composite reference sequence; whereby, the amplitude of each frequency component is compared with the total sum of its stand-alone sequence amplitude. A calibration factor is determined so that the amplitude of this composite reference frequency times the calibration factor must equal the total sum of the sequence amplitude—the zero-frequency amplitude of the discrete Fourier transform of its stand-alone sequence. To demultiplex the composite measured signal these calibration factors are multiplied by the amplitudes of the frequency components of the discrete Fourier transform of the composite X-phase-contrast measurement to obtain the amplitude of each frequency encoded measurement. Using these calibration factors, we demonstrate with the discrete Fourier transform in Mathematica the extraction of individual images from a composite image that one would expect obtaining from our proposed new X-ray phase contrast imaging system. We then demonstrate as an example how using images from X-ray phase contrast data one can calculate phase, attenuation and the dark field images using grading phase step data supplied to use from Microworks, GmbH in Karlsruhe, Germany.

42 ENGINEERING↗

Quantum Molecular Charge-Transfer Model for Multistep Auger–Meitner Decay Cascade Dynamics

The fragmentation of molecular cations following inner-shell decay processes in molecules containing heavy elements underpins the X-ray damage effects observed in X-ray scattering measurements of biological and chemical materials, as well as in medical applications involving Auger electron-emitting radionuclides. Traditionally, these processes are modeled using simulations that describe the electronic structure at an atomic level, thereby omitting molecular bonding effects. This work addresses the gap by introducing a novel approach that couples Auger–Meitner decay to nuclear dynamics across multiple decay steps, by developing a decay spawning dynamics algorithm and applying it to potential energy surfaces characterized with ab initio molecular dynamics simulations. We showcase the approach on a model decay cascade following K-shell ionization of IBr and subsequent Kβ fluorescence decay. We examine two competing channels that undergo two decay steps, resulting in ion pairs with a total 3+ charge state. This approach provides a continuous description of the electron transfer dynamics occurring during the multistep decay cascade and molecular fragmentation, revealing the combined inner-shell decay and charge transfer time scale to be approximately 75 fs. In conclusion, our computed kinetic energies of ion fragments show good agreement with experimental data.

Ab initio molecular dynamics↗

XRISM Spectroscopy of the Fe Kα Emission Line in the Seyfert Active Galactic Nucleus NGC 4151 Reveals the Disk, Broad-line Region, and Torus

Abstract We present an analysis of the first two XRISM/Resolve spectra of the well-known Seyfert-1.5 active galactic nucleus (AGN) in NGC 4151, obtained in 2023 December. Our work focuses on the nature of the narrow Fe K α emission line at 6.4 keV, the strongest and most common X-ray line observed in AGN. The total line is found to consist of three components. Even the narrowest component of the line is resolved with evident Fe K α ,1 (6.404 keV) and K α ,2 (6.391 keV) contributions in a 2:1 flux ratio, fully consistent with neutral gas with negligible bulk velocity. Subject to the limitations of our models, the narrowest and intermediate-width components are consistent with emission from optically thin gas, suggesting that they arise in a disk atmosphere and/or wind. Modeling the three line components in terms of Keplerian broadening, they are readily associated with (1) the inner wall of the “torus,” (2) the innermost optical “broad-line region” (or “X-ray BLR”), and (3) a region with a radius of r ≃ 100 GM / c 2 that may signal a warp in the accretion disk. Viable alternative explanations of the broadest component include a fast-wind component and/or scattering; however, we find evidence of variability in the narrow Fe K α line complex on timescales consistent with small radii. The best-fit models are statistically superior to simple Voigt functions, but when fit with Voigt profiles the time-averaged lines are consistent with a projected velocity broadening of FWHM = 1600 − 200 + 400 km s − 1 . Overall, the resolution and sensitivity of XRISM show that the narrow Fe K line in AGN is an effective probe of all key parts of the accretion flow, as it is currently understood. We discuss the implications of these findings for our understanding of AGN accretion, future studies with XRISM, and X-ray-based black hole mass measurements.

Audard, Marc (ORCID:000000034721034X)↗

Structure of Complex Liquid–Liquid Extraction Organic Phases for Rare Earth Separations

Complex, multicomponent liquids with hierarchical structure and phase transitions are encountered in many natural and industrial processes, including in chemical separations. One notable example is aggregation and organic phase splitting in liquid–liquid extraction (LLE) of metal ions. While these two phenomena that have long been closely associated, a mechanistic link between mesoscale structure and the capacity-limiting organic phase splitting remains elusive due to complexity of these systems. Here, in this study, we combine small-angle X-ray scattering (SAXS), X-ray photon correlation spectroscopy (XPCS), and molecular dynamics simulation to reveal a comprehensive picture of structure at the nano- and mesoscale in these complex solutions. For the representative case of rare earth extraction from an acidic aqueous phase by a malonamide extractant in dodecane, we investigate a wide range of process-relevant extractant and acid concentrations to provide a complete picture of how aggregation depends on composition. We decompose organic phase structure from SAXS into two contributions, which together can capture the scattering at all compositions: composition fluctuations described by the Ornstein–Zernike equation at low wavenumber Q, and nanostructure modeled by a “pre-peak” at intermediate Q. The former contains information about the thermodynamics of demixing, while the latter reflects nanoscopic self-assembly of the extractant and extracted solutes. While fluctuations have typically not been considered in the literature, we find they in fact dominate the total structure for nearly all practical conditions. As only the fluctuations have a strong temperature response, we confirm this attribution with temperature-dependent SAXS measurements, including for extracted europium nitrate complexes. SAXS and XPCS measurements near the critical point find static and dynamic scaling consistent with theory. Overall, this new paradigm for understanding LLE organic phases connects composition, nanoscale, and mesoscale structuring to phase behavior, providing both a comprehensive picture of solution structure and a quantitative link between aggregation and third phase formation.

Peroutka, Allison A. [Argonne National Laboratory ↗

Influence of helium bubbles on the bulk equation of state of gold under static compression

Nuclear materials often evolve into two-phase systems comprising a bulk matrix with dispersed inert-gas bubbles. The presence of these bubbles can have consequences to the thermomechanical response of materials and is a key life-limiting factor in some nuclear fuel forms. Understanding the behavior of these two-phase, bubble-matrix systems is, thus, important to improved predictive models and frameworks for many nuclear materials applications. While temperature excursions of these two-phase systems have been characterized, fewer studies have focused on the evolution of inert-gas bubbles under pressure. Here, in this paper, we use x-ray tools to interrogate a He-implanted gold foil to determine the pressure-dependent evolution of the individual components (Au matrix + bubbles), and we compare that total pressure dependence to theoretical equation-of-state descriptions based on mixing rules.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗