Search NASA⌕ Search

SEARCH · Search NASA

Results for “XRF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Intelligent Integrated Machining: Handheld XRF for Mapping Zr Coating and Al-6061 Cladding Thickness in RERTR Fuel Elements

An inexpensive commercially available handheld energy dispersive x‐ray fluorescence spectrometer is used to provide a rapid non‐destructive estimate of coating and/or cladding thickness in situ . The portable XRF instrument contains a battery‐operated low‐power polychromatic source coupled with a Peltier‐cooled silicon drift detector; built‐in analysis software based upon the Method of Fundamental Parameters converts measured spectral intensities to elemental concentrations, reported as normalized weight percentages. Using detected signals from elements unique to the base material and coating or cladding materials, calibration curves and associated empirical algorithms for determining the thickness of the high‐purity zirconium coating on an RERTR fuel element prior to cladding with aluminum, and for determining the thickness of the Al‐6061 cladding after HIP for a known zirconium layer thickness, are constructed. For Zr over bare DU‐10Mo, agreement between the measured and the calculated thickness is ± 5% or better. For the multilayer system consisting of Al‐6061 over Zr over Du‐10Mo, agreement between calculated and measured thickness is ± 10‐15% over the thickness range of interest. Simultaneous estimates for the Al cladding and underlying Zr coating can be made using the elemental composition output only when the Mo signal is in the quasi‐static range (corresponding to Al thicknesses of ~15 mils (0.381 mm) and greater) and not so low that measurement error is greater than the signal itself; under these conditions, accuracy is on the order of ±15 – 20%. More accurate determination of both Zr and Al thickness simultaneously may be possible if the count‐rates associated with individual fluorescent lines in the multilayer sample are available rather than just the weight percent composition currently output by the XRF analyzer software.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Doubly Curved Crystal Monochromatic XRF Instrumentation for Materials Characterization

The advent of doubly curved crystals (DCC) in XRF instrumentation offers new capabilities for materials characterization. The DCCs are unique in that they provide both point-to-point focusing as well as monochromatic treatment of the x-ray passing through the crystal. The advantages of the focusing and monochromatic treatments include: small spot focusing on the sample when used with an appropriate source and monochromatic excitation and monochromatic collection of elemental emission. hiRX (monochromatic wavelength dispersive XRF) employs all of these features into one instrumental package. The small spot size of the source (around 200 micrometers) is focused on a sample with a DCC coupled to the source to provide monochromatic excitation. The monochromatic excitation offers increased x-ray flux at the characteristic line of the x-ray anode (in this case Rh Ka1). Another DCC which has been selected for a specific energy/element is used to collect the emitted x-rays for the target analyte. The combination of low background excitation and narrow band (100-200 eV) collection offers high sensitivity and elemental selectivity. The performance of hiRX compared to conventional MXRF and confocal MXRF offers insights into the advantages and disadvantages of each methodology for Pu detection and quantification. These features are highlighted in the analysis of a Pu contaminated soil particle.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In situ XRF and gamma ray spectrometer for Mars sample return mission

A combined in situ X-ray fluorescence (XRF) and passive gamma ray spectrometer instrument is proposed for the chemical elemental analysis of various Martian surfaces and samples. The combined instrument can be carried on board a rover. The passive gamma ray or the neutron excited gamma ray system would be used to determine the elemental composition of the Martian surface while the rover is in motion. The XRF system would be used to perform analysis either on the Martian surface or on collected samples when the rover is stationary. The latter function is important both in cataloging the collected samples and in the selection of samples to be returned to earth. For both systems, data accumulation time would be on the order of 30 minutes. No sample preparation would be necessary.

Lo, I. Yin↗

Temporal Profiles and Spectral Lags of XRF 060218

The spectral and temporal properties of the nonthermal emission of the nearby XRF 060218 in the 0.3-150 keV band are studied. We show that both the spectral energy distribution and the light-curve properties suggest the same origin of the nonthermal emission detected by Swift BAT and XRT. This event has the longest pulse duration and spectral lag observed to date among the known GRBs. The pulse structure and its energy dependence are analogous to typical GRBs,. By extrapolating the observed spectral lag to the Compton Gamma Ray Observatory (CGRO) BATSE bands we find that the hypothesis that this event complies with the same luminosity-lag relation with bright GRBs cannot be ruled out at 2 sigma significance level. These intriguing facts, along with its compliance with the Amati relation, indicate that XRF 060218 shares the similar radiation physics as typical GRBs.

Liang, En-Wei↗

A Spectacular Radio Flare from XRF 050416a at 40 Days and Implications for the Nature of X-Ray Flashes

We present detailed optical, near-infrared, and radio observations of the X-ray flash 050416a obtained with Palomar and Siding Springs Observatories as well as HST and the VLA, placing this event among the best-studied X-ray flashes to date. In addition, we present an optical spectrum from Keck LRIS from which we measure the redshift of the burst, Z=0.6528. At this redshift the isotropic-equivalent prompt energy release was about 10(exp 51) erg, and using a standard afterglow synchrotron model we find that the blastwave kinetic energy is a factor of 10 larger, E-K,iso approximately equals 10 (exp 52) erg. The lack of an observed jet break to t - 20 days indicates that the opening angle is larger than 7 deg and the total beaming-corrected relativistic energy is larger than 10 exp (50) erg. We further show that the burst produced a strong radio flare at t is similar to 40 days accompanied by an observed flattening in the X-ray band which we attribute to an abrupt circumburst density jump or an episode of energy injection (either from a refreshed shock or off-axis ejecta). Late-time observations with HST show evidence for an associated supernova with peak optical luminosity roughly comparable to that of SN 1998bw. Next, we show that the host galaxy of XRF 050416a is actively forming stars at a rate of at least 2 M-solar per year with a luminosity of L-B is similar to 0.5L* and metallicity of Z is similar to 0.2-0.8 Z-solar. Finally, we discuss the nature of XRF 050416a in the context of short-hard gamma-ray bursts and under the framework of off-axis and dirty fireball models for X-ray flashes.

Soderberg, A. M.↗

The Fast Evolution of SN 2010bh Associated with XRF 100316D

The first observational evidence of a connection between supernovae (SNe) and gamma-ray bursts (GRBs) was found about a decade ago. Since then, only half a dozen spectroscopically confirmed associations have been discovered and XRF 1003160 associated with the type-Ic SN 20lObh is among the latest. Aims. We constrain the progenitor radius, the host-galaxy extinction, and the physical parameters of the explosion of XRF l00316D/SN 20lObh at z 0.059. We study the SN brightness and colours in the context of GRB-SNe. Methods. We began observations with the Gamma-Ray burst Optical and Near-infrared Detector (GROND) 12 hours after the GRB trigger and continued until 80 days after the burst. GROND provided excellent photometric data in six filter bands covering a wavelength range from approximately 350 to 1800 nm, significantly expanding the pre-existing data set for this event. Combining GROND and Swift data, the early broad-band spectral energy distribution (SED) is modelled with a blackbody and afterglow component attenuated by dust and gas absorption. The temperature and radius evolution of the thermal component are analysed and combined with earlier measurements available from the literature. Templates of SN 1998bw are fitted to the SN itself to directly compare the lightcurve properties. Finally, a two-component parametrized model is fitted to the quasi-bolometric light curve. which delivers physical parameters of the explosion. Results. The best-fit models to the broad-band SEDs imply moderate reddening along the line of sight through the host galaxy (A(sub v.host = 1.2 +/- 0.1 mag). Furthermore, the parameters of the blackbody component reveal a cooling envelope at an apparent initial radius of 7 x 10(exp 11) cm, which is compatible with a dense wind surrounding a Wolf-Rayet star. A multicolor comparison shows that SN 2010bh is 60 - 70% as bright as SN 1998bw. Reaching maximum brightness at 8 - 9 days after the burst in the blue bands, SN 20lObh proves to be the most rapidly evolving GRB-SNe to date. Modelling of the quasi-bolometric light curve yields M(sub Ni) = 0.21 +/- 0.03 solar M and M(sub ej) = 2.6 +/- 0.2 solar M, typical of values within the GRB-SN population. The kinetic energy is E(sub k) = (2.4 +/- 0.7) x 10(exp 52) erg, which is making this SN the second most energetic GRB-SN after SN 1998bw. Conclusions. This supernova has one of the earliest peaks ever recorded and thereafter fades more rapidly than other GRB-SNe, hypernovae, or typical type-Ic SNe. This could be explained by a thin envelope expanding at very high velocities, which is therefore unable to retain the gamma-rays that would prolong the duration of the SN event.

Olivares E., F.↗

Micro-XRF for In Situ Geological Exploration of Other Planets

In situ analysis of rock chemistry is a fundamental tool for exploration of planets. To meet this need, a high-spatial-resolution micro x-ray fluorescence (Micro-XRF) instrument was developed that is capable of determining the elemental composition of rocks (elements Na U) with 100 microns spatial resolution, thus providing insight to the composition of features as small as sand grains and individual laminae. The resulting excitation beam is of sufficient intensity that high signal-to-noise punctual spectra are acquired in seconds to a few minutes using an Amptek Silicon Drift Detector (SDD). The instrument features a tightly focused x-ray tube and HVPS developed by Moxtek that provides up to 200 micro-A at 10 to 50 keV, with a custom polycapillary optic developed by XOS Inc. and integrated into a breadboard Micro-XRF (see figure). The total mass of the complete breadboard instrument is 2.76 kg, including mounting hardware, mounting plate, camera, laser, etc. A flight version of this instrument would require less than 5W nominal power and 1.5 kg mass. The instrument includes an Amptek SDD that draws 2.5 W and has a resolution of 135 to 155 eV FWHM at 5.9 keV. It weighs 180 g, including the preamplifier, digital pulse processor, multichannel analyzer, detector and preamp power supplies, and packaging. Rock samples are positioned relative to the instrument by a three-axis arm whose position is controlled by closed-loop translators (mimicking the robotic arm of a rover). The distance from the source to the detector is calculated from the position of a focused laser beam on the sample as imaged by the camera. The instrument enables quick scans of major elements in only 1 second, and rapid acquisition (30 s) of data with excellent signal-to-noise and energy resolution for trace element analysis

Wade, Lawrence A.↗

Utah FORGE Well 56-32 Sludge XRF

This is an Excel spreadsheet containing the results of X-ray fluorescence from well 56-32 sludge samples. The instrumentation used was a Olympus Vanta M series handheld XRF analyzer. A glass (SiO2) "blank" was analyzed at the beginning and end of each sample batch to detect contamination within the instrument. The standard 2711A was analyzed at the beginning and end of each sample batch to detect drift in instrument precision over time. Material was analyzed in a plastic cup with a prolene thin film cover for minimal interference.

15 GEOTHERMAL ENERGY↗

100-OL-1 Operable Unit Field Portable X-Ray Fluorescence (XRF) Analyzer Pilot Study Plans

A pilot study is being conducted to support the approval of the Remedial Investigation/Feasibility Study (RI/FS) Work Plan to evaluate the 100-OL-1 Operable Unit (OU) pre-Hanford orchard lands. Based on comments received by the U.S. Environmental Protection Agency (EPA) and Washington State Department of Ecology, the pilot study will evaluate the use of field portable X-ray fluorescence (XRF) spectrometry measurements for evaluating lead and arsenic concentrations on the soil surface as an indicator of past use of lead arsenate pesticide residue in the OU. The work will be performed in the field during the summer of 2014, and assist in the planning for the characterization activities in the RI/FS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

INL CRMO XRF Report 2024-01: Provenance Determinations for 135 Haskett Projectile Points from Eastern Idaho

This report presents provenance determinations for 135 obsidian and fine-grained volcanic (FGV) Haskett projectile points from across eastern Idaho. These determinations were made using energy-dispersive X-ray fluorescence (ED-XRF) spectrometry at the Idaho National Laboratory (INL) Cultural Resource Management Office (CRMO) under the direction of Dr. Kyle Freund.

58 GEOSCIENCES↗

INL CRMO XRF Report 2025-03: Provenance Determinations for 854 Projectile Points from Idaho Falls District Bureau of Land Management Archaeological Collections

This report presents provenance determinations for 854 obsidian and fine-grained volcanic projectile points from Idaho Falls District Bureau of Land Management collections. Provenance determinations were made using energy dispersive X-ray fluorescence (ED-XRF) spectrometry at the Idaho National Laboratory (INL) Cultural Resource Management Office (CRMO) under the direction of Dr. Kyle Freund.

99 - GENERAL AND MISCELLANEOUS↗

INL CRMO XRF Report 2025-04: Provenance Determinations for 116 Obsidian Artifacts from Upper Snake U.S. Bureau of Reclamation Archaeological Collections

This report presents provenance determinations for 116 obsidian artifacts from Upper Snake U.S. Bureau of Reclamation collections. Provenance determinations were made using energy dispersive X-ray fluorescence (ED-XRF) spectrometry at the Idaho National Laboratory (INL) Cultural Resource Management Office (CRMO) under the direction of Dr. Kyle Freund.

99 - GENERAL AND MISCELLANEOUS↗

INL CRMO XRF Report 2025-02: Provenance Determinations for 1,124 Projectile Points from Lands and Collections Managed by the U.S. Department of Energy-Idaho Operations Office (DOE-ID)

This report presents provenance determinations for 1,124 obsidian and fine-grained volcanic (FGV) projectile points from lands and collections managed by the U.S. Department of Energy-Idaho Operations Office (DOE-ID). These determinations were made using energy-dispersive X-ray fluorescence (ED-XRF) spectrometry at the Idaho National Laboratory (INL) Cultural Resource Management Office (CRMO) under the direction of Dr. Kyle Freund.

58 GEOSCIENCES↗

INL CRMO XRF Report 2025-05: Provenance Determinations for 23 Folsom and Midland Projectile Points from Eastern Idaho

This report presents provenance determinations for 23 obsidian and fine-grained volcanic Folsom and Midland projectile points from eastern Idaho. Provenance determinations were made using energy dispersive X-ray fluorescence (ED-XRF) spectrometry at the Idaho National Laboratory (INL) Cultural Resource Management Office (CRMO) under the direction of Dr. Kyle Freund.

58 GEOSCIENCES↗

INL CRMO XRF Report 2025-06: Provenance Determinations for 246 Obsidian and Fine-grained Volcanic Artifacts from Folsom-era Sites in Eastern Idaho

This report presents provenance determinations for 246 obsidian and fine-grained volcanic artifacts from Folsom-era sites in eastern Idaho. Provenance determinations were made using energy dispersive X-ray fluorescence (ED-XRF) spectrometry at the Idaho National Laboratory (INL) Cultural Resource Management Office (CRMO) under the direction of Dr. Kyle Freund.

58 GEOSCIENCES↗

Gold Provenance Studies for Romanian Archaeological Objects Using Micro-SR-XRF

Studies by Synchrotron Radiation--X-Ray Fluorescence (SR-XRF) for the search of the presence of trace elements like Sb, Sn, Te and Pb in archaeological metallic objects found on the territory of Romania--old coins and Bronze Age jewelry, aimed to determine the provenance of the gold used in their manufacture. The results are compared with the detailed elemental composition of alluvial or primary gold samples, obtained by the same technique. This work attempted to establish the origin of the gold used for the mint of two different types of koson coins. We found that the kosons with monogram are made of refined gold, while the one used for the kosons without monogram is mainly alluvial. The gold used in the manufacture of the Calarasi Vulchitrun-type disk and the Tauteu hair ring is also of alluvial origin.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Correlations of trace elements in breast human tissues: Evaluation of spatial distribution using {mu}-XRF

The aim of this work is to investigate microscopic correlations between trace elements in breast human tissues. A synchrotron X-ray fluorescence microprobe system ({mu}-XRF) was used to obtain two-dimensional distribution of trace element Ca, Fe, Cu and Zn in normal (6 samples) and malignant (14 samples) breast tissues. The experiment was performed in X-ray Fluorescence beam line at Laboratorio Nacional de Luz Sincrotron (LNLS), Campinas, Brazil. The white microbeam was generated with a fine conical capillary with a 20 {mu}m output diameter. The samples were supported on a XYZ table. An optical microscope with motorized zoom was used for sample positioning and choice the area to be scanned. Automatic two-dimensional scans were programmed and performed with steps of 30 {mu}m in each direction (x, y) on the selected area. The fluorescence signals were recorded using a Si(Li) detector, positioned at 90 degrees with respect to the incident beam, with a collection time of 10 s per point. The elemental maps obtained from each sample were overlap to observe correlation between trace elements. Qualitative results showed that the pairs of elements Ca-Zn and Fe-Cu could to be correlated in malignant breast tissues. Quantitative results, achieved by Spearman correlation tests, indicate that there is a spatial correlation between these pairs of elements (p < 0.001) suggesting the importance of these elements in metabolic processes associated with the development of the tumor.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗