Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerated stress test (AST)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Evaluation of the Reliability of Passive Infrared (PIR) Occupancy Sensors for Residential Indoor Lighting

Solid-state lighting (SSL) technologies have penetrated the general illumination market in recent years, largely replacing conventional technologies such as incandescent and fluorescent lighting. Most of the initial excitement about light-emitting diode (LED) sources for SSL devices focused on their energy savings potential resulting from vast improvements in source efficiency and luminous efficacy compared with conventional illumination products. More recently, the focus has shifted toward other aspects of lighting application efficiency, namely intensity effectiveness and spectral efficiency, because of the ease of controlling both the light intensity of LEDs with drive voltage and the color properties of the LED-based illuminators. To capitalize on the energy savings of increased intensity effectiveness and spectral efficiency, a lighting control system (LCS) is often used. While the current penetration of LCSs is relatively modest, it is anticipated that lighting controls (i.e., connected lighting, controls and LED and conventional lighting) could have an installed penetration as higher as 46% by the year 2035, saving an additional 1.3 quads of energy. Despite the large energy savings that can be gained from using LCSs, standard test methods for evaluating sensors employed in LCSs and reliability data of the LCSs and their components are generally lacking. The National Electrical Manufacturers Association (NEMA) developed the only standard, NEMA WD 7-2011 (R2016), to test occupancy and motion sensor performance (herein referred to as “the NEMA protocol”). In a previous U.S. Department of Energy (DOE) effort, some concerns of the NEMA protocol were identified (e.g., strict height and weight limits on test subjects, large amounts of manual effort, sometimes inconsistent repeatability). During the current work, a consistent detection length test (DLT) and a Robotic Sensor Evaluation System (RoboSES) were developed to alleviate some of these concerns. RoboSES acts as a human surrogate by using thermal pads on a mannequin and a remote-controlled mobile base to test a sensor’s field of view (FOV). This report builds on the earlier DOE efforts to understand sensor technologies used in LCSs for general illumination. Specifically, this report describes the optimization of RoboSES, characterizes and establishes test methods to assess the reliability of multiple passive infrared (PIR) sensors, and reports the findings of robustness and reliability testing on two commercial PIR sensors intended for residential applications. The information presented in this report is gained from up to 4,000 hours (hrs) of accelerated stress tests (ASTs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Durable Fuel Cell MEA through Immobilization of Catalyst Particle and Membrane Chemical Stabilizer

For hydrogen-based fuel cell electric vehicle to be cost competitive with the incumbent diesel-powered internal combustion engine heavy-duty vehicle, the total cost of ownership of the truck must be decreased via both capital cost and the operating cost (H 2 fuel expense) reduction. This puts the emphasis on the decrease of fuel cell stack cost via use of low platinum catalyst material usage to decrease capital cost, high H 2 fuel efficiency and high stack durability to decrease the operating cost. US DOE has set a target of ≤ 0.25 mgPt/cm 2 total loading in the membrane electrode assembly, high fuel efficiency of > 68% and a HD-combined target of ≥ 2.5 kW/gPGM after running an accelerated stress test (AST) equivalent to 30,000 hours of heavy-duty fuel cell operation.

08 HYDROGEN↗

Validation of Advanced Photovoltaic Module Materials and Processes by Combined-Accelerated Stress Testing (C-AST)

Tessolar module technology was developed to allow the incorporation of 5 incremental module material innovations. Combined, these innovations may improve the efficiency and durability of the standard silicon cell module. The innovations evaluated are: electrically conductive adhesive (ECA) replacing soldering of tabbing ribbons, light-capturing ribbon (LCR), silicone encapsulant, 2 mm front glass with backsheet, and a polymer-composite module frame. Tessolar-constructed individually encapsulated cells incorporating the material innovations are used to assemble 60-cell modules. 2 x 2 cell mini-modules of the same materials were produced for combined-accelerated stress testing (C-AST). C-AST results demonstrate that the 2 x 2 cell mini-module of Tessolar construction out-performed mini-modules using both ECA with EVA and standard solder with EVA constructions in power production over 108 cycles of testing.

14 SOLAR ENERGY↗

Characterization of Interconnects

Combined-accelerated stress testing (C-AST) simultaneously combines stress factors of the natural environment (including UV radiation, temperature, humidity, electrical current, and external mechanical force) into a single test that requires fewer modules, fewer chambers, and makes it possible to discover weaknesses in new designs that are not known a-priori. C-AST reduces risk, accelerates time to market, and improves bankability by reducing costly overdesign using test levels not exceeding those seen in the natural environment. This project seeks to evaluate strengths and weaknesses of modern cell interconnect designs with combined-accelerated stress testing (C-AST) to screen multiple climates along with finite element and failure analysis to determine the potential for a 50-year life. Supporting this, we seek to develop methods of characterization to assess the degradation of interconnects, enable predictive rate models with material forensics and FEA and show C-AST's ability to find interconnect failures and benchmark it relative to other accelerated stress test methods like temperature cycling and cyclic dynamic mechanical loading. Examples of modern interconnect designs covered are Canadian Solar Hetero Technology ribbon enabling closer cell interconnections, SmartWire (eg. Meyer-Berger technology), and shingled cells with new interconnect materials.

C-AST↗

Acceleration Factors for Combined‐Accelerated Stress Testing of Photovoltaic Modules

Combined‐accelerated stress testing (C‐AST) is developed to establish the durability of photovoltaic (PV) products, including for degradation modes that are not a priori known or examined in standardized tests. C‐AST aims to comprehensively represent the sample, stress factors, and their combinations using levels at the statistical tails of the natural environment. Acceleration factors for relevant climate sequences within the C‐AST cycle with respect to the Florida USA climate are estimated for selected degradation mechanisms. It is found that for degradation of the outer backsheet polymer layer, the acceleration factor of the tropical climate sequence (the longest of the climate sequences) is f ( T , G ) = 17.3 with ultraviolet photodegradation; for polyethylene terephthalate hydrolysis (backsheets), f ( T , RH ) = 426; for electrochemical corrosion (PV cell), f ( I ) = 14.1; and for PbSn solder fatigue f (Δ T , r ( T )) = 17.3. Here, T is the module temperature, G is the broadband spectrum irradiance on the plane of array of the module, RH is the relative humidity on the module surface, I is the leakage current through the module packaging, and r ( T ), the number of temperature reversals. The methods discussed herein are generally applicable for evaluating acceleration factors in other accelerated test methods.

14 SOLAR ENERGY↗

Combined-Accelerated Stress Testing for Advanced Reliability Assessment of Photovoltaic Modules

New and previously undiscovered degradation mechanisms continue to be identified after field exposure in new photovoltaic module designs or materials oftentimes results in significant losses in investment. This is despite passing certification tests. Testing is insufficient largely due to their single-or double-stress nature. A Combined-Accelerated Stress Test (C-AST) has recently been developed. The test combines multiple stress factors of the natural environment to better replicate conditions experienced by modules in the field and detect mechanisms not a-priori known in new materials and designs.

accelerator factor modeling↗

Degradation behavior of CIGS solar Cells: A parametric analysis

A parametric study of the effect of bulk and interface properties on device characteristics as a function of heat and light stress under open-circuit and short-circuit conditions is developed for Cu(In,Ga)(S,Se) 2 solar cells using SCAPS-1D simulator. The variables and interdependencies modeled include: (1) conduction band offset (CBO) between buffer and absorber; (2) buffer ionized donor density; (3) CIGS shallow acceptor density; (4) CIGS deep acceptor density; (5) CIGS shallow donor density; (6) ionized acceptor concentration in the ordered vacancy compound (OVC) CIGS/buffer interface; and (7) back contact work-function. An increase in absorber shallow acceptor or a decrease in shallow donor density results in an increase in net carrier density and open-circuit voltage (V OC ). Further, a decrease in V OC is observed with an increase in the deep acceptors or neutral midgap defects in the CIGS due to higher charge carrier recombination. A change of CBO from spike to cliff condition is a dominant mechanism of decreasing VOC with an interface defect density of 10 12 cm -2 . The minimum depletion width is found to be specifically sensitive to CBO and interface defect density. An inflection in the capacitance–voltage curves (in reverse bias) is observed with simultaneous increase in bulk deep acceptor density and shallow donor density near the back contact.

14 SOLAR ENERGY↗

Evaluation of bifacial module technologies with combined–accelerated stress testing

In view of the increasing interest and market share of bifacial cells and modules, suitable substrates such as glass and transparent backsheets along with ethylene vinyl acetate (EVA) and polyolefin elastomer (POE) encapsulants were examined in combined-accelerated stress testing (C-AST) to evaluate and compare degradation modes. Testing with both monofacial and bifacial cells, we found glass-glass modules with monofacial cells led to greater grid finger breakage than those with polymeric backsheets. Furthermore, this is attributed to previous X-ray topography and modeling work showing higher stress in cells and interconnections in glass-glass modules than glass-backsheet modules. Consistent with the objectives of C-AST, which stresses modules at levels corresponding to the limits seen in the natural environment, we observed the UV-fluorescence signatures of modules tested in C-AST (considering the degradation associated with developing chromophores, moisture penetration and photobleaching effects) to be like those in fielded modules, more so than other chamber stress testing implemented for comparison. We found light-induced degradation (LID) in module types with regenerated (inactive) cells with C-AST, suggesting the possibility of LID destabilization in some field conditions. We could also distinguish potential-induced degradation (PID) on the back of the bifacial passivated emitter and rear cells (PERC) in C-AST. Confirming with ex-situ tests, we found polarization-type PID most prevalent in glass-glass modules with EVA as would be anticipated considering the greater leakage current through such module encapsulation. Unlike PID tests performed in the dark, which can lead to false positive PID test results, field-representative illumination is experienced by the modules on the front and back side while –1200 V system voltage is applied in C-AST, supporting the conclusion that this module type with glass-glass construction would be susceptible to PID in the field.

14 SOLAR ENERGY↗

Towards validation of combined-accelerated stress testing through failure analysis of polyamide-based photovoltaic backsheets

Abstract Novel methods for advancing reliability testing of photovoltaic (PV) modules and materials have recently been developed. Combined-accelerated stress testing (C-AST) is one such method which has demonstrated reliable reproduction of some field-failures which were not reproducible by standard certification tests. To increase confidence and assist in the development of C-AST, and other new testing protocols, it is important to validate that the failure modes observed and mechanisms induced are representative of those observed in the field, and not the product of unrealistic stress conditions. Here we outline a method using appropriate materials characterization and modelling to validate the failure mechanisms induced in C-AST such that we can increase confidence in the test protocol. The method is demonstrated by applying it to a known cracking failure of a specific polyamide (PA)-based backsheet material. We found that the failure of the PA-based backsheet was a result of a combination of stress factors. Photo-oxidation from ultra-violet (UV) radiation exposure caused a reduction in fracture toughness, which ultimately lead to the cracking failure. We show that the chemical and structural changes observed in the backsheet following C-AST aging were also observed in field-aged samples. These results increase confidence that the conditions applied in C-AST are representative of the field and demonstrates our approach to validating the failure mechanisms induced.

14 SOLAR ENERGY↗

Accelerated Aging of PV Cables - The Development of Methods Towards Combined-Accelerated Stress Testing

PV cables allow the collection and distribution of electricity from modules to the energy grid. Durable cabling allows continuous operation of PV installations. Cables with a life less than that of the modules must be replaced - reducing electricity generation and adding to the system operating expense. We have examined the durability of a variety of representative cable samples using artificial UV weathering (IEC TS 62788-7-2) and combined accelerated stress testing (C-AST). Jackets in this study include PV-rated (polyolefin), building wire (PVC/PA), and multi-conductor (rubber, as in PV trackers), with some examples of black and red cables. Characterizations at read points include appearance (camera and optical microscope), surface roughness (linear profilometry), instrumented indentation, surface morphology (SEM), chemical composition (EDS), thermal decomposition (TGA), phase transition (DSC), crystalline structure (WAXS), and polymer chemical structure (FTIR). Complimentary examinations confirm damage to the external and interior layer(s) of less durable samples, including changes in morphology (e.g., cracking), chemistry (e.g., oxidation), structure, and mechanical performance (e.g., through-thickness modulus and hardness). The results may be generally compared to other examples from the field (PV installations) or after accelerated testing (IEC 61215). The methods in this study are presently being applied in a follow-on C-AST study, incorporating both dynamic and kinematic fixtures.

balance of systems↗

Failure Analysis of a New Polyamide-Based Fluoropolymer-Free Backsheet After Combined-Accelerated Stress Testing

The viability of novel coextruded, fluoropolymer-free backsheets for photovoltaic (PV) modules has been questioned as a result of a large number of early-life backsheet failures in PV installations containing one of the earliest co-extruded polyamide (PA)-based backsheet to reach the market, “AAA.” New PV reliability testing protocols have been recently developed and applied to backsheets to reproduce failures observed in the field and evaluate the durability of novel backsheet materials and designs prior to commercialization. A new co-extruded PA-based backsheet was tested using combined-accelerated stress testing (C-AST) and demonstrated a greater lifetime than AAA, and some other fluoropolymer-based backsheets such as polyvinylidene fluoride. The improved PA-based backsheet also eventually failed by through-thickness cracking. Using surface and bulk material characterization techniques, we performed a comprehensive study of material properties before and after the stress testing. Aging of the backsheet resulted in an increase of surface roughness by erosion of the outer PA layer. However the failure is more likely related to an increase in crystallinity of the polyolefin core layer reducing the backsheet tearing energy. The analysis can ultimately inform on the specific weaknesses of the materials so that the manufacturer can improve the backsheet design to extend its lifetime.

14 SOLAR ENERGY↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 degrees C from ~40 degrees C) and a different failure mode were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy).

balance of systems↗

Photovoltaic Cable Jackets: A Comparison of Representative Products Using Combined-Accelerated Stress Testing [Slides]

Photovoltaic (PV) cables facilitate the distribution of electricity collected from modules to the energy grid. Durable cabling enables continuous operation of PV installations, whereas cables with a lifetime less than the modules must be replaced - reducing electricity generation and adding to the operating expense. This study primarily focusses on the aging of the key cable types using the combined-accelerated stress testing (C-AST) protocol. Representative cables for utility, building, and control/auxiliary applications were examined. Cable jacket materials examined include: polyolefin, polyethylene, polyamide, poly(vinyl chloride), chlorinated polyethylene, thermoplastic elastomer, and ethylene propylene diene monomer rubber. Specimen characterizations applied include: optical microscopy, mechanical profilometry, instrumented indentation, scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), Fourier-transform infrared spectroscopy (FTIR), thermogravimetric analysis (TGA), and differential scanning calorimetry (DSC). A variety of performance and durability characteristics were observed, depending on the base material, polymer formulation, and jacket color. The results from C-AST are analyzed and discussed relative to a recent industry survey on electronic balance of system components in addition to a recent study where similar cables were aged using steady state ultraviolet weathering (International Electrotechnical Commission Technical Specification 62788-7-2). Recommendations are made for the screening, industry qualification, and service life prediction of PV cable jackets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for C-AST. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed immediately once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure occurring in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy). Chemical composition analysis included: energy-dispersive X-ray spectroscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy.

balance of systems↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing: Preprint

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy).

balance of systems↗

Evaluation of Bifacial Modules and PV Technologies with Combined-Accelerated Stress Testing

In view of the increasing interest and market share of bifacial cells and modules, suitable substrates such as glass and transparent backsheets along with ethylene vinyl acetate (EVA) and polyolefin elastomer (POE) encapsulants were examined in combined-accelerated stress testing (C-AST) to evaluate and compare degradation modes. Testing with both monofacial and bifacial cells, we found glass-glass modules with monofacial cells led to greater grid finger breakage than those with polymeric backsheets. This is attributed to previous x-ray topography work showing higher stress in cells in glass-glass modules than glass backsheet modules. Consistent with the objectives of C-AST, which stresses modules at levels corresponding to the limits seen in the natural environment, we observed the UV-fluorescence signatures of modules tested in C-AST (considering the degradation associated with developing chromophores, moisture penetration and photobleaching effects) to be like those in fielded modules, more so than other chamber stress testing implemented for comparison. Finally, among multiple cell degradation modes that we observed such as light-induced degradation (LID), we differentiated susceptibility to potential-induced degradation (PID) on the back of the bifacial Passivated Emitter Back Cells (PERC) in C-AST. Confirming with ex-situ tests, we found polarization-type PID most prevalent in glass/glass modules with EVA as would be anticipated considering the greater leakage current through such module encapsulation. Unlike PID tests performed in the dark, which can lead to false positive PID test results, field-representative illumination is experienced by the modules on the front and back side while -1200 V system voltage is applied in C-AST, supporting the conclusion that this module type would be susceptible to PID in the field.

bifacial modules↗