Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator test facility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Low Energy Accelerator Facility Upgrade and test

The Low Energy Accelerator Facility (LEAF) contains a low-energy linac with high average beam power, which was designed and built in the late 1960’s primarily for radiation-chemistry experiments. The maximum beam energy in that configuration was 21 MeV. Although, the installation is old, it is still reliable. The accelerator was repurposed for development of accelerator-based technologies for the production of 99Mo with funding provided by the National Nuclear Security Administration’s Office of Material Management and Minimization (M3 ). An extensive scientific program on the production of radioactive isotopes demanded an upgrade of the accelerator to fit the experimental requirements. Several possible LEAF upgrades were proposed to increase the electron beam energy. The final design proposed the replacement of the old accelerating structures with new ones. In 2011-2012, the new structures were manufactured, installed, and tested with the beam energy up to 50 MeV and average beam power up to 20 kW. LEAF now is an attractive installation for performing research into medical isotope production.

Alford, K.↗

Implementation of a 1550-nm laser system for beam characterization at the Argonne Wakefield Accelerator

Accurately recording an electron bunch’s longitudinal profile is an important diagnostic for wakefield accelerators employing shaped bunches to increase transformer ratios. Electro-optic sampling of terahertz radiation from the bunch is an attractive approach due to its non-destructive nature. In preparation for future characterization experiments, the Argonne Wakefield Accelerator test facility has recently installed a 1550 nm laser system, including the necessary support systems to synchronize with the photoinjector laser system at 81.25 MHz. We report here on the initial installation and synchronization demonstrations.

Ody, Alexander [Argonne, PHY]↗

High Resolution BPM Upgrade for the ATF Damping Ring at KEK

A beam position monitor (BPM) upgrade at the KEK Accelerator Test Facility (ATF) damping ring has been accomplished, carried out by a KEK/FNAL/SLAC collaboration under the umbrella of the global ILC R&D effort. The upgrade consists of a high resolution, high reproducibility read-out system, based on analog and digital down-conversion techniques, digital signal processing, and also implements a new automatic gain error correction schema. The technical concept and realization as well as results of beam studies are presented. The next generation of linear colliders require ultra-low vertical emittance of <2 pm-rad. The damping ring at the KEK Accelerator Test Facility (ATF) is designed to demonstrate this mission critical goal. A high resolution beam position monitor (BPM) system for the damping ring is one of the key tools for realizing this goal. The BPM system needs to provide two distnict measurements. First, a very high resolution ({approx}100-200nm) closed-orbit measurement which is averaged over many turns and realized with narrowband filter techniques - 'narrowband mode'. This is needed to monitor and steer the beam along an optimum orbit and to facilitate beam-based alignment to minimize non-linear field effects. Second, is the ability to make turn by turn (TBT) measurements to support optics studies and corrections necessary to achieve the design performance. As the TBT measurement necessitates a wider bandwidth, it is often referred to as 'wideband mode'. The BPM upgrade was initiated as a KEK/SLAC/FNAL collaboration in the frame of the Global Design Initiative of the International Linear Collider. The project was realized and completed using Japan-US funds with Fermilab as the core partner.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantitative phase retrieval with picosecond X-ray pulses from the ATF Inverse Compton Scattering source

Quantitative phase retrieval is experimentally demonstrated using the Inverse Compton Scattering X-ray source available at the Accelerator Test Facility (ATF) in the Brookhaven National Laboratory. Phase-contrast images are collected using in-line geometry, with a single X-ray pulse of approximate duration of one picosecond. The projected thickness of homogeneous samples of various polymers is recovered quantitatively from the time-averaged intensity of transmitted X-rays. The data are in good agreement with the expectations showing that ATF Inverse Compton Scattering source is suitable for performing phase-sensitive quantitative X-ray imaging on the picosecond scale. The method shows promise for quantitative imaging of fast dynamic phenomena.

43 PARTICLE ACCELERATORS↗

Advanced accelerator test facility-Final report for the period 9/1/2010 - 8/31/2013

This final report summarizes results achieved in the Beam Physics Laboratory at Yale University during the period 9/1/2010 – 8/31//2013, under DoE grant DE-FG02-07 ER 41504. During the period covered by this report, notable progress in technical consolidation of facilities in the Yale Beam Physics Laboratory has occurred; and theory, design, and fabrication for future experiments have been carried out. In the period covered by this grant, 29 scientific publications based on this work and related topics have appeared in the archival literature. Titles, authors, and citations are listed in Section V of this report.

43 PARTICLE ACCELERATORS↗

Research, design and development activities on high power pulsed rf/microwave systems and test facilities for particle accelerators

Several high power S Band microwave systems in the peak power range from 2 MW to 6.5 MW and mean power upto 25 kW along with associated waveguide components, pulse power technology were developed in house at RRCAT. These systems have been used extensively in the development of particle accelerators in the country. Several test facilities were developed in house and supplied to tube R and D labs for development, conditioning and evaluation of microwave tubes indigenously under collaborative efforts. RRCAT has also taken up establishing high power test facilities for advanced accelerators. For such used design and development of 45 MW peak power S Band test facility as well as energy doubler scheme is underway. A 1.3 MW pulsed test stand at 352.2 MHz was also successfully designed and developed to qualify devices, subsystems and components developed in-house. The present paper will describe the research, design and development efforts towards the high power pulsed RF/Microwave systems, test facilities and components. The results and performance of these developments are reported. (author)

43 PARTICLE ACCELERATORS↗

SNS shielding analyses overview

This paper gives an overview on on-going shielding analyses for Spallation Neutron Source. Presently, the most of the shielding work is concentrated on the beam lines and instrument enclosures to prepare for commissioning, save operation and adequate radiation background in the future. There is on-going work for the accelerator facility. This includes radiation-protection analyses for radiation monitors placement, designing shielding for additional facilities to test accelerator structures, redesigning some parts of the facility, and designing test facilities to the main accelerator structure for component testing. Neutronics analyses are required as well to support spent structure management, including waste characterisation analyses, choice of proper transport/storage package and shielding enhancement for the package if required.

Popova, Irina↗

Status and Plans for a SRF Accelerator Test Faciliy at Fermilab

A superconducting RF accelerator test facility is being constructed at Fermilab. The existing New Muon Lab (NML) building is being converted for this facility. The accelerator will consist of an electron gun, injector, beam acceleration secti on consisting of 3 TTF-type or ILC-type cryomodules, multiple downstream beamlines for testing diagnostics and conducting various beam tests, and a high power beam dump. When completed, it is envisioned that this facility will initially be capable of gene rating a 810 MeV electron beam with ILC beam intensity. Expansion plans of the facility are underway that will provide the capability to upgrade the accelerator to a total beam energy of 1.5 GeV. In addition to testing accelerator components, this facilit y will be used to test RF power equipment, instrumentation, LLRF and controls systems for future SRF accelerators such as the ILC and Project-X. This paper describes the current status and overall plans for this facility.

43 PARTICLE ACCELERATORS↗

Experiment and simulations of sub-ps electron bunch train generation at Fermilab photoinjectors

Recently the generation of electron bunch trains with sub-picosecond time structure has been experimentally demonstrated at the A0 photoinjector of Fermilab using a transverse-longitudinal phase-space exchange beamline. The temporal profile of the bunch train can be easily tuned to meet the requirements of the applications of modern accelerator beams. In this paper we report the A0 bunch-train experiment and explore numerically the possible extension of this technique to shorter time scales at the Fermilab SRF Accelerator Test Facility, a superconducting linear electron accelerator currently under construction in the NML building.

43 PARTICLE ACCELERATORS↗

Demonstration of the stabilization technique for nonplanar optical resonant cavities utilizing polarization

Based on our previously developed scheme to stabilize nonplanar optical resonant cavities utilizing polarization caused by a geometric phase in electromagnetic waves traveling along a twisted path, we report an application of the technique for a cavity installed in the Accelerator Test Facility, a 1.3-GeV electron beam accelerator at KEK, in which photons are generated by laser-Compton scattering. We successfully achieved a power enhancement of 1200 with 1.4% fluctuation, which means that the optical path length of the cavity has been controlled with a precision of 14 pm under an accelerator environment. In addition, polarization switching utilizing a geometric phase of the nonplanar cavity was demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a horizontal test cryostat for superconducting RF cavities for the FREIA facility at Uppsala University

Uppsala University is constructing a large scale facility, called FREIA (Facility for Research Instrumentation and Accelerator Development). FREIA includes a helium liquefier and an accelerator test facility and has the capacity to test superconducting radio-frequency (RF) cavities with the same RF system and RF power level as in an accelerator. A central element of FREIA is a horizontal test cryostat connected in closed loop to a helium liquefier. This cryostat can house two fully equipped (tuners, piezo, power coupler, helium tank) superconducting cavities to perform full RF high power tests and operate at temperatures between 1.8 K and 4.2 K. The cryostat is designed to accommodate a large array of superconducting cavities and magnets, among which the European Spallation Source (ESS) type spoke and high-β elliptical cavities as well as TESLA/ILC type elliptical cavities. The present status of the project and the design of the cryostat are reported.

43 PARTICLE ACCELERATORS↗

Beam Optics Measurements in Medium Energy Beam Transport at PIP-II Injector Test Facility

The Proton Improvement Plan-II Injector Test (PIP2IT) is an accelerator test facility under construction at Fermilab that will provide a platform to demonstrate critical technologies and concept of the front-end of the PIP-II linear accelerator (linac). The PIP2IT warm front-end comprises a H⁻ ion source capable of delivering 15 mA, 30 keV DC or pulsed beam, a Low Energy Beam Transport (LEBT), a 162.5 MHz, CW Radio Frequency Quadrupole (RFQ) that accelerates the beam to 2.1 MeV and, a 14 m medium energy beam transport (MEBT). Presently, beamline up to the MEBT has been commissioned and operates routinely at the PIP2IT facility. In this paper, we discuss beam measurements performed at the MEBT to analyze beam emittance and its RMS sizes along the MEBT. In addition, beam based calibration of the beamline elements using differential trajectory measurement is also presented.

43 PARTICLE ACCELERATORS↗

Recent Studies in ATF Damping Ring

The damping ring of the Accelerator Test Facility (ATF) at KEK is designed to produce an extremely small vertical emittance beam as a test accelerator for future linear colliders. Development of various system and components for ILC (International Linear Collider) is also an important purpose of this facility. Though most of the beam time of ATF is dedicated to the final focus test project (ATF2), some studies have been performed in the damping ring. Here we report recent effort of low emittance tuning and multi-bunch extraction test of the fast kicker.

43 PARTICLE ACCELERATORS↗

A compact tunable quadrupole lens for brighter and sharper ultra-fast electron diffraction imaging

In this article, we report our proof-of-principle design and experimental commissioning of a broadly tunable and low-cost transverse focusing lens system for MeV-energy electron beams. The lens system based on electromagnetic (EM) quadrupoles has been built as a part of the existing instrument for ultra-fast electron diffraction (UED) experiments at the Accelerator Test Facility II (ATF-II) at Brookhaven National Laboratory (BNL). We experimentally demonstrated the independent control of the size and divergence of the beam with the charge ranging from 1 to 13 pC. The charge density and divergence of the beam at the sample are the most important factors determining the quality of the Bragg-diffraction image (BDI). By applying the Robust Conjugate Directional Search (RCDS) algorithm for online optimization of the quadrupoles, the transverse beam size can be kept constant down to 75 µm from 1 to 13 pC. The charge density is nearly two orders of magnitude higher than the previously achieved value using a conventional solenoid. Using the BDI method we were able to extract the divergence of the beam in real-time and apply it to the emittance measurement for the first time. Our results agree well with simulations and with the traditional quadrupole scan method. The real-time divergence measurement opens the possibility of online optimization of the beam divergence (< 0.2 mrad) at the sample with the increased beam charge. This optimization is crucial for the future development of single-shot ultra-fast electron microscope (UEM). Finally, we demonstrated BDI with significant improvement, up to 3 times higher peak intensity and 2 times sharper Bragg-diffraction peaks at 13 pC. The charge is now limited by the laser power and increasing charge may improve the quality of BDI further. The capability we demonstrated here provides us with opportunities for new sciences using near-parallel, bright and ultrafast electron beams for single-shot imaging, to directly visualize the dynamics of defects and nanostructured materials, or even record molecular movie, which are impossible using present electron-beam technologies.

43 PARTICLE ACCELERATORS↗

Numerical study of self modulation instability of 1 nC electron bunch at ATF

The development of self-modulation instability (SMI) is investigated numerically for the 1 nC electron bunch available at Accelerator Test Facility (ATF) of Brookhaven National Laboratory (BNL). Possible experiment based on the simulation results is proposed. All the simulations are performed with the 2D-cylindrically symmetric particle-in-cell code.

43 PARTICLE ACCELERATORS↗

Designing a Magnetic Measurement Data Acquisition and Control System With Reuse in Mind: A Rotating Coil System Example

Accelerator magnet test facilities frequently need to measure different magnets on differently equipped test stands and with different instrumentation. Designing a modular and highly reusable system that combines flexibility built-in at the architectural level as well as on the component level addresses this need. Specification of the backbone of the system, with the interfaces and dataflow for software components and core hardware modules, serves as a basis for building such a system. The design process and implementation of an extensible magnetic measurement data acquisition and control system are described, including techniques for maximizing the reuse of software. The discussion is supported by showing the application of this methodology to constructing two dissimilar systems for rotating coil measurements, both based on the same architecture and sharing core hardware modules and many software components. The first system is for production testing 10 m long cryo-assemblies containing two MQXFA quadrupole magnets for the high-luminosity upgrade of the Large Hadron Collider and the second for testing IQC conventional quadrupole magnets in support of the accelerator system at Fermilab.

43 PARTICLE ACCELERATORS↗

Plasma wakefields in the quasi-nonlinear regime: Experiments at ATF

In this work we present details of planned experiments to investigate certain aspects of the quasi non linear regime (QNL) of plasma wakefield acceleration (PWFA). In the QNL regime it is, in principal, possible to combine the benefits of both nonlinear and linear PWFA. That is, beams of high quality can be maintained through acceleration due to the complete ejection of plasma electrons from beam occupied region, while large energy gains can be achieved through use of transformer ratio increasing schemes, such as ramped bunch trains. With the addition of an short focal length PMQ triplet capable of focusing beams to the few micron scale and the ability to generate tunable bunch trains, the Accelerator Test Facility (ATF) at Brookhaven National Lab offers the unique capabilities to probe these characteristics of the QNL regime.

43 PARTICLE ACCELERATORS↗