Search NASA⌕ Search

SEARCH · Search NASA

Results for “acceptance angle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Design of a High Flux Vacuum-Ultraviolet Beamline for Circular Dichroism Experiments

A vacuum-ultraviolet bending-magnet beamline for circular dichroism (CD) experiments has been designed. To maximize the photon flux and minimize the focused beam size, a cylindrical mirror and a cylindrical grating with independent optical functions are utilized. The beamline can collect a 30 mrad horizontal by 7 mrad vertical solid angle of synchrotron radiation. By using a 600 grooves/mm grating, the calculated photon flux is greater than 1x10{sup 13} photons/sec and the focused beam size is 0.4 mmx0.65 mm for the spectral range from 130 nm to 330 nm with the energy resolving power set at 1000. The linear polarization degree is better than 75% and can be increased to 90% by reducing the vertical acceptance angle down to 2 mrad. In addition to the high flux mode described above, this beamline can also be operated in a high resolution mode. By using a 1200 grooves/mm grating, a resolving power greater than 10,000 can be achieved for the spectral range from 180 to 330 nm. This beamline can provide photon flux as high as the best synchrotron CD beamlines in the world while offers simultaneously a smaller focused beam size.

43 PARTICLE ACCELERATORS↗

A novel high resolution ion wide angle spectrometer

A novel ion wide angle spectrometer (iWASP) has been developed, which is capable of measuring angularly resolved energy distributions of protons and a second ion species, such as carbon C{sup 6+}, simultaneously. The energy resolution for protons and carbon ions is better than 10% at {approx}50 MeV/nucleon and thus suitable for the study of novel laser-ion acceleration schemes aiming for ultrahigh particle energies. A wedged magnet design enables an acceptance angle of 30 deg. ({approx}524 mrad) and high angular accuracy in the {mu}rad range. First, results obtained at the LANL Trident laser facility are presented demonstrating high energy and angular resolution of this novel iWASP.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SAMRAI: A novel variably polarized angle-resolved photoemission beamline in the VUV region at UVSOR-II

A novel variably polarized angle-resolved photoemission spectroscopy beamline in the vacuum-ultraviolet (VUV) region has been installed at the UVSOR-II 750 MeV synchrotron light source. The beamline is equipped with a 3 m long APPLE-II type undulator with horizontally/vertically linear and right/left circular polarizations, a 10 m Wadsworth type monochromator covering a photon energy range of 6-43 eV, and a 200 mm radius hemispherical photoelectron analyzer with an electron lens of a {+-}18 deg. acceptance angle. Due to the low emittance of the UVSOR-II storage ring, the light source is regarded as an entrance slit, and the undulator light is directly led to a grating by two plane mirrors in the monochromator while maintaining a balance between high-energy resolution and high photon flux. The energy resolving power (h{nu}/{Delta}h{nu}) and photon flux of the monochromator are typically 1x10{sup 4} and 10{sup 12} photons/s, respectively, with a 100 {mu}m exit slit. The beamline is used for angle-resolved photoemission spectroscopy with an energy resolution of a few meV covering the UV-to-VUV energy range.

43 PARTICLE ACCELERATORS↗

A rotatable electron spectrometer for multicoincidence experiments

We have developed a rotatable hemispherical spectrometer with good energy and angular resolution, which can be positioned with the lens axis arbitrarily within a solid angle of 1 {pi}. The collection angle of the emitted electrons with respect to the polarization axis of the light is set by means of a three-axes goniometer, operating under vacuum. An important requirement for this setup was the possibility to perform coincidences between the electron analyzed by the spectrometer and one or several other particles, such as ions, electrons, or photons. The lens system and the hemispheres have been designed to accommodate such experimental demands, regarding parameters such as the resolving power, the acceptance angle, or the width of the kinetic energy window which can be recorded for a given pass energy. We have chosen to detect the impact position of the electron at the focal plane of the hemispherical analyzer with a delay line detector and a time-to-digital converter as acquisition card rather than using a conventional charge-coupled device camera.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chapter 6: CPV Tracking and Trackers

This chapter explains the functional requirements of a concentrator photovoltaic (CPV) sun tracker. It derives the design specifications of a CPV tracker. The chapter presents taxonomy of trackers describing the most common tracking architectures, based on the number of axes, their relative position, and the foundation and placing of tracking drives. It deals with the structural issues related to tracker design, mainly related to structural flexure and its impact on the system's acceptance angle. The chapter analyzes the auto-calibrated sun tracking control, by describing the state of the art and its development background. It explores the sun tracking accuracy measurement with a practical example. The chapter discusses tracker manufacturing and tracker field works. It reviews survey of different types of tracker designs obtained from different manufacturers. Finally, the chapter deals with IEC62817, the technical standard developed for CPV sun trackers.

14 SOLAR ENERGY↗

Designer Metasurfaces for Antireflective Applications Enabled by Advanced Nanoparticle Technology

Optic processing advances have shifted system limitations, with current constraints consisting of antireflective (AR) coatings applied to optics and the inability to reduce size, weight, and price. Metasurfaces, and more broadly metaoptics, provide an avenue to overcome these limitations. The ability to generate substrate-engraved metasurfaces that can be tailored is demonstrated within a broad design space to satisfy large-area AR applications for bandpass or broadband needs, demonstrating an optically equivalent surface roughness standard deviation of only 5 Å. Using an advanced nanoparticle masking approach, two metasurfaces are fabricated: 1) vertical sidewall nanofeature metasurface (MS) for AR applications at 351 nm, and 2) sloped sidewall MS designed for broadband AR applications. For the 351 nm MS, the reflectance is measured to be 0.127%. In the case of the sloped sidewall MS, the reflectance is measured to be <0.25% over 400–700 nm and <1% over 400–1100 nm. To the best of the authors’ knowledge, this is the first demonstration of a broadband AR capable of this performance. The tunability of these structures, with a parameter space spanning even more remarkable designs such as broader bands and acceptance angles, coupled with high laser-induced damage durability and mechanical robustness, displays the strength of metasurfaces for AR applications.

36 MATERIALS SCIENCE↗

Porous Nanomaterials for Ultrabroadband Omnidirectional Anti‐Reflection Surfaces with Applications in High Concentration Photovoltaics

Materials for nanoporous coatings that exploit optimized chemistries and self‐assembly processes offer capabilities to reach ≈98% transmission efficiency and negligible scattering losses over the broad wavelength range of the solar spectrum from 350 nm to 1.5 µm, on both flat and curved glass substrates. These nanomaterial anti‐reflection coatings also offer wide acceptance angles, up to ±40°, for both s‐ and p‐polarization states of incident light. Carefully controlled bilayer films have allowed for the fabrication of dual‐sided, gradient index profiles on plano‐convex lens elements. In concentration photovoltaics platforms, the resultant enhancements in the photovoltaics efficiencies are ≈8%, as defined by experimental measurements on systems that use microscale triple‐junction solar cells. These materials and their applications in technologies that require control over interface reflections have the potential for broad utility in imaging systems, photolithography, light‐emitting diodes, and display technologies.

Yao, Yuan↗

Identifying the secondary electron cutoff in ultraviolet photoemission spectra for work function measurements of non-ideal surfaces

Abstract Absolute values of work functions can be determined in ultraviolet photoemission spectroscopy (UPS) by measuring the minimum kinetic energy of secondary electrons generated by a known photon energy. However, some samples can produce spectra that are difficult to interpret due to additional intensity below the true secondary electron cutoff. Disordered absorbates on elemental metals add small intensity below the onset for the transition metal surfaces studied, which can be attributed to energy losses after photoelectrons are generated. In contrast, spectra from WO 3−x films can produce multiple onsets with comparable intensity which do not fit this model. False onsets (in the context of work function measurements) can be minimized by optimizing experimental detection parameters including limiting analyzer acceptance angles and pass energy. True work functions can be identified by examining the onsets as the sample bias is varied.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Stimulated resonant inelastic X-ray scattering in a solid

Abstract When materials are exposed to X-ray pulses with sufficiently high intensity, various nonlinear effects can occur. The most fundamental one consists of stimulated electronic decays after resonant absorption of X-rays. Such stimulated decays enhance the number of emitted photons and the emission direction is confined to that of the stimulating incident photons which clone themselves in the process. Here we report the observation of stimulated resonant elastic (REXS) and inelastic (RIXS) X-ray scattering near the cobalt L 3 edge in solid Co/Pd multilayer samples. We observe an enhancement of order 10 6 of the stimulated over the conventional spontaneous RIXS signal into the small acceptance angle of the RIXS spectrometer. We also find that in solids both stimulated REXS and RIXS spectra contain contributions from inelastic electron scattering processes, even for ultrashort 5 fs pulses. Our results reveal the potential and caveats of the development of stimulated RIXS in condensed matter.

36 MATERIALS SCIENCE↗

Compact cosmic ray detector for unattended atmospheric ionization monitoring

Two vertical cosmic ray telescopes for atmospheric cosmic ray ionization event detection are compared. Counter A, designed for low power remote use, was deployed in the Welsh mountains; its event rate increased with altitude as expected from atmospheric cosmic ray absorption. Independently, Counter B's event rate was found to vary with incoming particle acceptance angle. Simultaneous co-located comparison of both telescopes exposed to atmospheric ionization showed a linear relationship between their event rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Status of the Superomega Muon Beamline

The Superomega muon beamline is currently under construction at Experimental hall No. 2 of the Materials and Life Science Facility at J-PARC in Tokai, Japan. The beamline has a large solid angle acceptance, and will produce the highest intensity pulsed muon beam in the world. The beamline is designed to capture both surface positive and cloud negative muons for simultaneous use in a variety of experiments. The expected rate of surface muons for this beamline is 4x10{sup 8}{mu}{sup +}/s, and that for cloud muons is 10{sup 7}{mu}{sup -}/s. The beamline consists of the normal-conducting capture solenoid, the superconducting curved transport solenoid and axial focusing solenoid. The construction of the capture solenoid has been completed and installed in March 2009, and the transport solenoid is now fabricated, and will be installed in the summer of 2011. The calculation of the beamline optics of the axial focusing solenoid is underway.

43 PARTICLE ACCELERATORS↗

Scanning photoelectron microscope for nanoscale three-dimensional spatial-resolved electron spectroscopy for chemical analysis

In order to achieve nondestructive observation of the three-dimensional spatially resolved electronic structure of solids, we have developed a scanning photoelectron microscope system with the capability of depth profiling in electron spectroscopy for chemical analysis (ESCA). We call this system 3D nano-ESCA. For focusing the x-ray, a Fresnel zone plate with a diameter of 200 {mu}m and an outermost zone width of 35 nm is used. In order to obtain the angular dependence of the photoelectron spectra for the depth-profile analysis without rotating the sample, we adopted a modified VG Scienta R3000 analyzer with an acceptance angle of 60 deg. as a high-resolution angle-resolved electron spectrometer. The system has been installed at the University-of-Tokyo Materials Science Outstation beamline, BL07LSU, at SPring-8. From the results of the line-scan profiles of the poly-Si/high-k gate patterns, we achieved a total spatial resolution better than 70 nm. The capability of our system for pinpoint depth-profile analysis and high-resolution chemical state analysis is demonstrated.

36 MATERIALS SCIENCE↗

Hard x-ray tomographic studies of the destruction of an energetic electron ring

A tomography system was designed and built at the Large Plasma Device to measure the spatial distribution of hard x-ray (100 KeV-3 MeV) emissivity. The x-rays were generated when a hot electron ring was significantly disrupted by a shear Alfven wave. The plasma is pulsed at 1 Hz (1 shot/s). A lead shielded scintillator detector with an acceptance angle defined by a lead pinhole is mounted on a rotary gimbal and used to detect the x-rays. The system measures one chord per plasma shot using only one detector. A data plane usually consists of several hundred chords. A novel Dot by Dot Reconstruction (DDR) method is introduced to calculate the emissivity profile from the line integrated data. In the experiments, there are often physical obstructions, which make measurements at certain angles impossible. The DDR method works well even in this situation. The method was tested with simulated data, and was found to be more effective than previously published methods for the specific geometry of this experiment. The reconstructed x-ray emissivity from experimental data by this method is shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The correlation between the radial distribution of high-energetic ions and the structural as well as electrical properties of magnetron sputtered ZnO:Al films

The origin of the pronounced radial distributions of structural and electrical properties of magnetron sputtered ZnO:Al films has been investigated. The film properties were correlated with the radially resolved ion-distribution functions. While the positive ions exhibit low energies and a radial distribution with a maximum intensity opposite the center of the target, the negative ions can have energies up to several hundred eV, depending on the target potential, with a radial distribution with two maxima opposite the erosion tracks. The most prominent positive ion is that of the working gas (Ar{sup +}), while the highest flux of the negative ions is measured for negative oxygen O{sup −}. The radial distribution of the flux of the high-energetic negative ions can clearly be related to the radial variations of the structural (c-axis lattice parameter, crystallite size) and electronic (resistivity) properties for sputtering from the planar target, which points to the decisive role of the high-energetic negative oxygen ions for the film quality. The relation between the negative ion bombardment and the structural as well as electronic properties can be explained by a qualitative model recently developed by us. The same target has also been investigated in the eroded state. In this case, the limited acceptance angle of the mass spectrometer leads to a misinterpretation of the radial distribution of the flux of the high-energetic negative ions. This effect can be explained by a simulation, based on the assumption that the high-energetic negative ions are mainly accelerated in the cathode (target) sheath perpendicular to the uneven substrate surface.

36 MATERIALS SCIENCE↗

Off-resonance photoemission dynamics studied by recoil frame F1s and C1s photoelectron angular distributions of CH{sub 3}F

F1s and C1s photoelectron angular distributions are considered for CH{sub 3}F, a molecule which does not support any shape resonance. In spite of the absence of features in the photoionization cross section profile, the recoil frame photoelectron angular distributions (RFPADs) exhibits dramatic changes depending on both the photoelectron energy and polarization geometry. Time-dependent density functional theory calculations are also given to rationalize the photoionization dynamics. The RFPADs have been compared with the theoretical calculations, in order to assess the accuracy of the theoretical method and rationalize the experimental findings. The effect of finite acceptance angles for both ionic fragments and photoelectrons has been included in the calculations, as well as the effect of rotational averaging around the fragmentation axis. Excellent agreement between theory and experiment is obtained, confirming the good quality of the calculated dynamical quantities (dipole moments and phase shifts)

74 ATOMIC AND MOLECULAR PHYSICS↗

Measuring coalignment of retroreflectors with large lateral incoming-outgoing beam offset

A method based on phase-shifting Fizeau interferometry is presented with which retroreflectors with large incoming-outgoing beam separations can be tested. The method relies on a flat Reference Bar that is used to align two auxiliary mirrors parallel to each other to extend the aperture of the interferometer. The method is applied to measure the beam coalignment of a prototype Triple Mirror Assembly of the GRACE Follow-On Laser Ranging Interferometer, a future satellite-to-satellite tracking device for Earth gravimetry. The Triple Mirror Assembly features a lateral beam offset of incoming and outgoing beam of 600 mm, whereas the acceptance angle for the incoming beam is only about ±2 mrad. With the developed method, the beam coalignment of the prototype Triple Mirror Assembly was measured to be 9 μrad with a repeatability of below 1 μrad.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Invited Review Article: Development of crystal lenses for energetic photons

This paper follows the development of crystal diffraction lenses designed to focus energetic photons. It begins with the search for a solution to the astrophysics problem of how to detect weak astrophysics sources of gamma rays and x-rays. This led to the basic designs for a lens and to the understanding of basic limitations of lens design. The discussion of the development of crystal diffraction lenses is divided into two parts: lenses using crystals with mosaic structure, and lenses that use crystals with curved crystal planes. This second group divides into two sub-groups: (1) Curved crystals that are used to increase the acceptance angle of the diffraction of a monochromatic beam and to increase the energy bandwidth of the diffraction. (2) Curved crystals used to focus gamma ray beams. The paper describes how these two types of crystals affect the design of the corresponding crystal lenses in different fields: astrophysics, medical imaging, detection of weak, distant, gamma-ray sources, etc. The designs of crystal lenses for these applications are given in enough detail to allow the reader to design a lens for his own application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact broadband ion beam focusing device based on laser-driven megagauss thermoelectric magnetic fields

Ultra-intense lasers can nowadays routinely accelerate kiloampere ion beams. These unique sources of particle beams could impact many societal (e.g., proton-therapy or fuel recycling) and fundamental (e.g., neutron probing) domains. However, this requires overcoming the beam angular divergence at the source. This has been attempted, either with large-scale conventional setups or with compact plasma techniques that however have the restriction of short (<1 mm) focusing distances or a chromatic behavior. Here, we show that exploiting laser-triggered, long-lasting (>50 ps), thermoelectric multi-megagauss surface magnetic (B)-fields, compact capturing, and focusing of a diverging laser-driven multi-MeV ion beam can be achieved over a wide range of ion energies in the limit of a 5° acceptance angle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗